Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Radiation Field of Packages Carrying Spent Co-60 Radioactive Sources - 12437

Among the diverse radioactive sources commonly exploited in medical and industrial applications, Co- 60 is increasingly used as strong gamma emitter. Over time, source manufacturers favored Co-60 as opposed to other gamma emitters because its relatively short half-life (5.27 year) that minimizes issues related to the management of disused sources. Disused Co-60 sources can retain a significant amount of radioactivity (from hundreds of MBq to several GBq) that still poses safety concerns on their handling and transportation. In this context a detailed knowledge of their radiation field would provide the necessary information for taking actions in preventing unnecessary doses to the workers and the population by optimizing transportation procedures and handling operations. We modeled the geometry and the materials constituting a transportation packaging of a spent Co-60 source which had an original maximum activity of a few GBq and was enclosed in a small lead irradiator. Then we applied a Monte Carlo transport code (MCNP5) for tracking down the gamma photons emitted by the source, including the secondary photons resulting by the interaction of the source photons with the surrounding materials. This allowed for the evaluation of the radiation field inside and outside the packaging, and the corresponding equivalent dose useful for checking the compliance with the regulations and the health risk of possible radiation exposure. We found that a typical 60-liters drum carrying a spent Co-60 source, enclosed in its original irradiator, with a residual activity of 300 MBq could already overcome an equivalent dose of 0.2 mSv/h on the drum external surface, which is the maximum equivalent dose at any point of the surface for this packaging as prescribed by local regulations. This condition is even more apparent when the source is slightly displaced with respect to the rotation axis of the drum, an easily occurring condition for sources not properly packaged, generating non-compliant hot-spots on the drum surface. As an example, a displacement of 5 cm translates in an increase of 80% in the dose level on the nearest side of the drum. We also found that the equivalent dose is significantly influenced by the scattered source photons and the secondary photons, whose contribution to the radiation field is mainly determined by the package geometry. The developed model resulted in an important tool for exploring the detail of the radiation field of a spent Co-60 source packaged for transportation allowing to check for compliance with the regulations and to evaluate risks to the workers and the population. It is worth to point out that this modeling approach is completely general and can be applied to a variety of different problems not limited to the transportation of radioactive material. In the example illustrated in this work, a small Co-60 source inside its irradiator and properly packaged in a drum for transport, presents a hot-spot on the drum surface if the irradiator is displaced of just few centimeters with respect to the rotation axis of the drum. A Monte Carlo simulation provided a complete description of the radiation field in the volume surrounding the packaging as a function of photon energy showing that a significant contribution comes from source photons scattered by the package itself. As an example, the Transport Index (TI) of this packaging was calculated, resulting in a value of 0.5. This value is low when compared to the regulations, however suggests that an individual just 1 meter afar from the packaging receives, in a few hours, a dose comparable to that received with a radiograph. This might be the case of the driver of a truck transporting the packaging, in particular when a number of packages are transported at the same time. It is important to notice that the results presented in this work are general, and can be appropriately scaled to represent the radiation field of similar geometries with gamma sources of different activity. However, this quick application of a Monte Carlo simulation provides useful insights in the process of preparing a packaging for transport. This simple model suggests that this approach can be efficient for screening a number of packaging configurations and flagging those potentially not compliant with regulations, that will require a more thorough care in the packaging process. Furthermore the knowledge of the details of the radiation field can be useful for optimizing the geometry of the transport cargo, and becomes essential when a variety of packaging are transported or stored, in order to prevent hazardous situations during their handling, and hence preventing unnecessary doses to the workers and the populations. It is worth to point out that this modeling approach is completely general and can be applied to a variety of different problems not limited to the transportation of radioactive material. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical study of atomic production rate in hydrogen negative ion sources with the effect of non-equilibrium electron energy distribution function

Spatial non-uniformity of the dissociative hydrogen atom (H{sup 0}) production has been investigated in a large negative ion source (JAEA 10 A source) with the electron energy distribution function (EEDF) obtained by a Monte-Carlo simulation code for electron transport in 3D3V (three dimensional real and velocity) space. It has been shown that the H{sup 0} production rate becomes larger in the upper region (one side in the longitudinal direction) of the source chamber. This spatial non-uniformity of the H{sup 0} production profile is mainly explained by the non-equilibrium features of the EEDF in the upper region, i.e., the EEDF consists of thermal electron component with kinetic energy ε < 25 eV and fast electron component with energy ε > 25 eV in the upper region, while the EEDF mainly consists of only thermal electrons in the bottom region. These characteristics for the EEDF and the energy dependence of cross-sections for dissociation and dissociative ionization processes lead to the non-uniform profile of the H{sup 0} production. The above numerical results of the spatial H{sup 0} non-uniformity are validated and confirmed by comparisons with those by spectroscopic measurement. It has been clarified that the non-equilibrium (fast electron) component of the EEDF has a large contribution to the non-uniformity of the H{sup 0} production rate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-117: Dose to Organs Outside of CT Scan Range- Monte Carlo and Hybrid Phantom Approach

Purpose: Epidemiological study of second cancer risk for cancer survivors often requires the dose to normal tissues located outside the anatomy covered by radiological imaging, which is usually limited to tumor and organs at risk. We have investigated the feasibility of using whole body computational human phantoms for estimating out-of-field organ doses for patients treated by Intensity Modulated Radiation Therapy (IMRT). Methods: Identical 7-field IMRT prostate plans were performed using X-ray Voxel Monte Carlo (XVMC), a radiotherapy-specific Monte Carlo transport code, on the computed tomography (CT) images of the torso of an adult male patient (175 cm height, 66 kg weight) and an adult male hybrid computational phantom with the equivalent body size. Dose to the liver, right lung, and left lung were calculated and compared. Results: Considerable differences are seen between the doses calculated by XVMC for the patient CT and the hybrid phantom. One major contributing factor is the treatment method, deep inspiration breath hold (DIBH), used for this patient. This leads to significant differences in the organ position relative to the treatment isocenter. The transverse distances from the treatment isocenter to the inferior border of the liver, left lung, and right lung are 19.5cm, 29.5cm, and 30.0cm, respectively for the patient CT, compared with 24.3cm, 36.6cm, and 39.1cm, respectively, for the hybrid phantom. When corrected for the distance, the mean doses calculated using the hybrid phantom are within 28% of those calculated using the patient CT. Conclusion: This study showed that mean dose to the organs located in the missing CT coverage can be reconstructed by using whole body computational human phantoms within reasonable dosimetric uncertainty, however appropriate corrections may be necessary if the patient is treated with a technique that will significantly deform the size or location of the organs relative to the hybrid phantom.

60 APPLIED LIFE SCIENCES↗

X-Ray Spectra from General Relativistic Radiation Magnetohydrodynamic Simulations of Thin Disks

We compare X-ray emission from several general relativistic, multifrequency, radiation magnetohydrodynamic simulations of thin black hole accretion disks with different accretion rates and spins. The simulations were performed using the M1 closure scheme, resolved with 12 frequency (energy) bins logarithmically spaced from 5 × 10 −3 to 5 × 10 3 ​​​ keV. We apply a general relativistic Monte Carlo transport code to postprocess the simulation data with greater fidelity in frequency resolution and Compton scattering treatment. Despite the relatively few energy bins and Kompaneets approximation to Compton scattering utilized in the M1 method, we find generally good agreement between the methods. Both produce prominent thermal profiles with peaks around 2–2.5 keV, where agreement is particularly strong and representative of the soft state. Both also find weaker (lower-luminosity) thermally sourced emission extending out to 100 keV due to the hotter innermost regions of the disks. Inverse Compton scattering becomes increasingly effective at hardening spectral outputs with increasing black hole spin, and becomes the dominant mechanism for photons that escape with energies between 10 to several hundred keV. At very high rates of spin, the radiation flux in this upscattered component becomes comparable to the thermal flux, a phenomenon typically associated with intermediate states. Beyond 10 4 keV, we observe faint, free–free emission from hot, optically thin coronal regions developing near the horizon, common to both spinning and nonspinning black holes.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-H-BRC-05: Stereotactic Radiosurgery Optimized with Orthovoltage Beams

Purpose: To achieve improved stereotactic radiosurgery (SRS) dose distributions using orthovoltage energy fluence modulation with inverse planning optimization techniques. Methods: A pencil beam model was used to calculate dose distributions from the institution’s orthovoltage unit at 250 kVp. Kernels for the model were derived using Monte Carlo methods as well as measurements with radiochromic film. The orthovoltage photon spectra, modulated by varying thicknesses of attenuating material, were approximated using open-source software. A genetic algorithm search heuristic routine was used to optimize added tungsten filtration thicknesses to approach rectangular function dose distributions at depth. Optimizations were performed for depths of 2.5, 5.0, and 7.5 cm, with cone sizes of 8, 10, and 12 mm. Results: Circularly-symmetric tungsten filters were designed based on the results of the optimization, to modulate the orthovoltage beam across the aperture of an SRS cone collimator. For each depth and cone size combination examined, the beam flatness and 80–20% and 90–10% penumbrae were calculated for both standard, open cone-collimated beams as well as for the optimized, filtered beams. For all configurations tested, the modulated beams were able to achieve improved penumbra widths and flatness statistics at depth, with flatness improving between 33 and 52%, and penumbrae improving between 18 and 25% for the modulated beams compared to the unmodulated beams. Conclusion: A methodology has been described that may be used to optimize the spatial distribution of added filtration material in an orthovoltage SRS beam to result in dose distributions at depth with improved flatness and penumbrae compared to standard open cones. This work provides the mathematical foundation for a novel, orthovoltage energy fluence-modulated SRS system.

60 APPLIED LIFE SCIENCES↗

TH-AB-209-11: Breast Microcalcification Classification Using Spectral X-Ray Coherent Scatter Computed Tomography

Purpose: To investigate the ability of Coherent Scatter Computed Tomography (CSCT) to distinguish non-invasively between type I calcifications, consisting of calcium oxalate dihydrate (CO) compounds which are more often associated with benign lesions, and type II calcifications containing hydroxyapatite (HA) which are predominantly associated with malignant tumors. Methods: The coherent scatter cross sections of HA and CO were measured using an energy dispersive x-ray diffractometer. The measured cross sections were introduced into MC-GPU Monte Carlo simulation code for studying the applicability of CSCT to discriminate between the two types of microcalcifications within the whole breast. Simulations were performed on a virtual phantom with inserted HA and CO spots of different sizes and placed in regions of interest having different background compositions. We considered a polychromatic x-ray source and an energy resolving photon counting detector. We applied an algorithm that estimates scatter components in projection space in order to obtain material-specific images of the breast. As material components adipose, glandular, HA and CO were used. The relative contrast of HA and CO components were used for type I and type II microcalcification discrimination. Results: The reconstructed CSCT images showed material-specific component-contrast values, with the highest CO or HA component contrast corresponding generally to the actual CO or HA feature, respectively. The discrimination performance varies with the x-ray intensity, calcification size, and background composition. The results were summarized using receiver operating characteristic (ROC) analysis with the area under the curve (AUC) taken as an overall indicator of discrimination performance and showing high AUC values up to unity. Conclusion: The simulation results obtained for a uniform breast imaging phantom indicate that CSCT has potential to be used as a non-invasive method for discrimination between type I and type II microcalcifications.

60 APPLIED LIFE SCIENCES↗

Improvements in Electron-Photon-Relaxation Data for MCNP6

The Los Alamos Monte Carlo transport code MCNP6 has recently benefitted from significant work to improve the photon-electron transport and atomic-relaxation capabilities of the code. The improvements include extension of existing photon data to lower energies than previously supported; addition of new data such as subshell-specific photoelectric cross sections; completion of the incoherent and coherent form factor data to cover all scattering angles at all supported energies; new data for electron interactions including Bremsstrahlung, elastic scattering, subshell-specific electroionization, and atomic excitation; a much more detailed representation for atomic relaxation; and an entirely new (to MCNP) approach to electron transport: the single-event method. These improvements were made available with the initial production release of MCNP6 along with an extended electron, photon, and relaxation data file eprdata12 to support the new capabilities. More recently new data have become available and have now been incorporated into MCNP6, correcting a few issues with the previous work, and adding new sets of cross sections that were not included in eprdata12. The purpose of this paper is to introduce these newer changes and enhancements, which will be included with the next public release of the MCNP6 code system. The database that supports these developments relies on an evolving set of libraries originally released by D. E. Cullen and collaborators as separate data for photo-atomic interactions (EPDL), atomic relaxation (EADL), and electro-atomic interactions (EEDL). An updated version of this release was officially adopted in the ENDF/B VI.8 release of the Evaluated Nuclear Data File and it was this source that was used to produce the ACE (A Compact ENDF) format library eprdata12 for use in the initial production release of MCNP6.1 (and the subsequent interim release MCNP6.1.1). The latest improved version of this database was released by Cullen in 2014. This is the EPICS2014 collection, which includes both an ENDF-formatted file and separate EPDL, EADL, and EEDL files. In the area of photon-electron transport and atomic-relaxation, the newest enhancements to the current version of MCNP6 (scheduled for release as MCNP6.2) are primarily based on improvements and additions drawn from the EPICS2014 data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-CAMPUS-I-02: Estimation of the Dosimetric Error Caused by the Voxelization of Hybrid Computational Phantoms Using Triangle Mesh-Based Monte Carlo Transport

Purpose: Computational voxel phantom provides realistic anatomy but the voxel structure may result in dosimetric error compared to real anatomy composed of perfect surface. We analyzed the dosimetric error caused from the voxel structure in hybrid computational phantoms by comparing the voxel-based doses at different resolutions with triangle mesh-based doses. Methods: We incorporated the existing adult male UF/NCI hybrid phantom in mesh format into a Monte Carlo transport code, penMesh that supports triangle meshes. We calculated energy deposition to selected organs of interest for parallel photon beams with three mono energies (0.1, 1, and 10 MeV) in antero-posterior geometry. We also calculated organ energy deposition using three voxel phantoms with different voxel resolutions (1, 5, and 10 mm) using MCNPX2.7. Results: Comparison of organ energy deposition between the two methods showed that agreement overall improved for higher voxel resolution, but for many organs the differences were small. Difference in the energy deposition for 1 MeV, for example, decreased from 11.5% to 1.7% in muscle but only from 0.6% to 0.3% in liver as voxel resolution increased from 10 mm to 1 mm. The differences were smaller at higher energies. The number of photon histories processed per second in voxels were 6.4×10{sup 4}, 3.3×10{sup 4}, and 1.3×10{sup 4}, for 10, 5, and 1 mm resolutions at 10 MeV, respectively, while meshes ran at 4.0×10{sup 4} histories/sec. Conclusion: The combination of hybrid mesh phantom and penMesh was proved to be accurate and of similar speed compared to the voxel phantom and MCNPX. The lowest voxel resolution caused a maximum dosimetric error of 12.6% at 0.1 MeV and 6.8% at 10 MeV but the error was insignificant in some organs. We will apply the tool to calculate dose to very thin layer tissues (e.g., radiosensitive layer in gastro intestines) which cannot be modeled by voxel phantoms.

60 APPLIED LIFE SCIENCES↗

SU-E-T-238: Deriving Electron Contamination Spectra From Pure and Clinical Photon Beams

Purpose: To extract the electron contamination energy spectra for an Elekta Precise Linac, based on pure photon and measured clinical beam percentage depth dose data. And to include this as an additional source in isource 4 in DOSXYZnrc. Methods: A pure photon beam was simulated for the Linac using isource 4 in the DOSXYZnrc Monte Carlo (MC) code. Percentage depth dose (PDD) data were extracted afterwards for a range of field sizes (FS). These simulated dose data were compared to actual measured dose PDD data, with the data normalized at 10 cm depth. The resulting PDD data resembled the electron contamination depth dose. Since the dose fall-off is a strictly decreasing function, a method was adopted to derive the contamination electron spectrum. Afterwards this spectrum was used in a DOSXYZnrc MC simulation run to verify that the original electron depth dose could be replicated. Results: Various square aperture FS’s for 6, 8 and 15 megavolt (MV) photon beams were modeled, simulated and compared to their respective actual measured PDD data. As FS increased, simulated pure photon depth-dose profiles shifted deeper, thus requiring electron contamination to increase the surface dose. The percentage of electron weight increased with increase in FS. For a FS of 15×15 cm{sup 2}, the percentage electron weight is 0.1%, 0.2% and 0.4% for 6, 8 and 15 MV beams respectively. Conclusion: From the PDD results obtained, an additional electron contamination source was added to the photon source model so that simulation and measured PDD data could match within 2 % / 2 mm gamma-index criteria. The improved source model could assure more accurate simulations of surface doses. This research project was funded by the South African Medical Research Council (MRC) with funds from National Treasury under its Economic Competitiveness and Support package.

60 APPLIED LIFE SCIENCES↗

Precise Dynamical Masses and Orbital Fits for β Pic b and β Pic c

We present a comprehensive orbital analysis to the exoplanets β Pictoris b and c that resolves previously reported tensions between the dynamical and evolutionary mass constraints on β Pic b. We use the Markov Chain Monte Carlo orbit code orvara to fit 15 years of radial velocities and relative astrometry (including recent GRAVITY measurements), absolute astrometry from Hipparcos and Gaia, and a single relative radial velocity measurement between β Pic A and b. We measure model-independent masses of 9.3{sub −2.5}{sup +2.6} M {sub Jup} for β Pic b and 8.3 ± 1.0 M {sub Jup} for β Pic c. These masses are robust to modest changes to the input data selection. We find a well-constrained eccentricity of 0.119 ± 0.008 for β Pic b, and an eccentricity of 0.21{sub −0.09}{sup +0.16} for β Pic c, with the two orbital planes aligned to within ∼05. Both planets’ masses are within ∼1σ of the predictions of hot-start evolutionary models and exclude cold starts. We validate our approach on N-body synthetic data integrated using REBOUND. We show that orvara can account for three-body effects in the β Pic system down to a level ∼5 times smaller than the GRAVITY uncertainties. Systematics in the masses and orbital parameters from orvara’s approximate treatment of multiplanet orbits are a factor of ∼5 smaller than the uncertainties we derive here. Future GRAVITY observations will improve the constraints on β Pic c’s mass and (especially) eccentricity, but improved constraints on the mass of β Pic b will likely require years of additional radial velocity monitoring and improved precision from future Gaia data releases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Model-Based Radiation Dose Correction for Yttrium-90 Microsphere Treatment of Liver Tumors With Central Necrosis

Purpose: The objectives of this study were to model and calculate the absorbed fraction {phi} of energy emitted from yttrium-90 ({sup 90}Y) microsphere treatment of necrotic liver tumors. Methods and Materials: The tumor necrosis model was proposed for the calculation of {phi} over the spherical shell region. Two approaches, the semianalytic method and the probabilistic method, were adopted. In the former method, the range--energy relationship and the sampling of electron paths were applied to calculate the energy deposition within the target region, using the straight-ahead and continuous-slowing-down approximation (CSDA) method. In the latter method, the Monte Carlo PENELOPE code was used to verify results from the first method. Results: The fraction of energy, {phi}, absorbed from {sup 90}Y by 1-cm thickness of tumor shell from microsphere distribution by CSDA with complete beta spectrum was 0.832 {+-} 0.001 and 0.833 {+-} 0.001 for smaller (r{sub T} = 5 cm) and larger (r{sub T} = 10 cm) tumors (where r is the radii of the tumor [T] and necrosis [N]). The fraction absorbed depended mainly on the thickness of the tumor necrosis configuration, rather than on tumor necrosis size. The maximal absorbed fraction {phi} that occurred in tumors without central necrosis for each size of tumor was different: 0.950 {+-} 0.000, and 0.975 {+-} 0.000 for smaller (r{sub T} = 5 cm) and larger (r{sub T} = 10 cm) tumors, respectively (p < 0.0001). Conclusions: The tumor necrosis model was developed for dose calculation of {sup 90}Y microsphere treatment of hepatic tumors with central necrosis. With this model, important information is provided regarding the absorbed fraction applicable to clinical {sup 90}Y microsphere treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-H-BRC-03: Evaluation of Very High-Energy Electron (VHEE) Beams in Comparison to VMAT and PBS Treatment Plans

Purpose: The aim of this study was to evaluate the performance of very high-energy electron (VHEE) beams in comparison to clinically delivered treatment plans generated with volumetric modulated arc therapy (VMAT) and proton pencil beam scanning (PBS) technology. Methods: Three clinical cases were selected (prostate, lung, and pediatric CNS). The VHEE plans were calculated in the Monte Carlo EGSnrc code and pencil beam doses were calculated using the DOSxyznrc MC code for 100 and 200 MeV beams. Treatment plans with VHEE, VMAT, and PBS were optimized in a research version of RayStation using an in house build script in order to minimize operator bias between the different techniques. Results: For the prostate cancer case, the PBS plan showed lower mean organ at risk (OAR) doses compared to the other modalities. An exception was the femoral heads, due to the lateral beam arrangements. The VMAT plan showed lower mean doses to the rectum and the bladder compared to the 100 MeV VHEE plan. The lung cancer case showed minor differences between the three modalities. However, the PBS plan showed a lower contralateral lung dose. The pediatric CNS case showed a better conformity and lower spinal cord dose for the 100 MeV VHEE plan. For all cases, the 200 MeV VHEE plans were found to be similar to or better than the 100 MeV VHEE plans. Conclusion: The present study showed that VHEE plans are similar or superior to VMAT plans with reduced mean OAR dose and increased target conformity for a variety of clinical cases. With increased VHEE energy, better conformity and even higher reductions in mean OAR doses can be achieved. Funding: DoD, Award#:W81XWH-13-1-0165, Weston Havens Foundation, Bio-X (Stanford University), the Office of the Dean of the Medical School, the Office of the Provost (Stanford University), and the Swedish Childhood Cancer Foundation. BL and PM are founders of TibaRay,Inc. BL and PM have received research grants from Varian and RaySearch Laboratory.

60 APPLIED LIFE SCIENCES↗

SU-E-T-278: Realization of Dose Verification Tool for IMRT Plan Based On DPM

Purpose: To build a Monte Carlo dose verification tool for IMRT Plan by implementing a irradiation source model into DPM code. Extend the ability of DPM to calculate any incident angles and irregular-inhomogeneous fields. Methods: With the virtual source and the energy spectrum which unfolded from the accelerator measurement data,combined with optimized intensity maps to calculate the dose distribution of the irradiation irregular-inhomogeneous field. The irradiation source model of accelerator was substituted by a grid-based surface source. The contour and the intensity distribution of the surface source were optimized by ARTS (Accurate/Advanced Radiotherapy System) optimization module based on the tumor configuration. The weight of the emitter was decided by the grid intensity. The direction of the emitter was decided by the combination of the virtual source and the emitter emitting position. The photon energy spectrum unfolded from the accelerator measurement data was adjusted by compensating the contaminated electron source. For verification, measured data and realistic clinical IMRT plan were compared with DPM dose calculation. Results: The regular field was verified by comparing with the measured data. It was illustrated that the differences were acceptable (<2% inside the field, 2–3mm in the penumbra). The dose calculation of irregular field by DPM simulation was also compared with that of FSPB (Finite Size Pencil Beam) and the passing rate of gamma analysis was 95.1% for peripheral lung cancer. The regular field and the irregular rotational field were all within the range of permitting error. The computing time of regular fields were less than 2h, and the test of peripheral lung cancer was 160min. Through parallel processing, the adapted DPM could complete the calculation of IMRT plan within half an hour. Conclusion: The adapted parallelized DPM code with irradiation source model is faster than classic Monte Carlo codes. Its computational accuracy and speed satisfy the clinical requirement, and it is expectable to be a Monte Carlo dose verification tool for IMRT Plan. Strategic Priority Research Program of the China Academy of Science(XDA03040000); National Natural Science Foundation of China (81101132)

60 APPLIED LIFE SCIENCES↗

Neutronics Analysis Supporting Baseline Fuel-Rodlet Irradiation Design in TREAT Multi-SERTTA Vehicle

The Transient Reactor Test (TREAT) Facility is a thermal-spectrum test reactor designed to evaluate reactor fuels and structural material under simulated nuclear excursion and transient power/cooling mismatch situations in nuclear reactors. TREAT was historically operated from 1959 through 1994. There are ongoing activities to resume its transient testing capabilities to support advanced reactor designs and validate computational predictions of fuel and core behavior. Such validation will be an important factor for review and approval of next generation power reactor design and safety evaluations. Historic methods used in TREAT were very approximate and served to estimate a predicted transient power shape. A number of calibration test experiments were then required prior to the actual transient test to better estimate the power that would have been deposited in the experiment during a transient pulse. Much of the experience in the use of these legacy methods has also been lost over the past two decades. Monte Carlo criticality codes are being utilized for calculation of the initial critical state, control rod reactivity worth, and power coupling between core and experiments. Current efforts primarily support neutronics characterization with safety and design analyses for the Multi-SERTTA (Static Environment Rodlet Transient Test Apparatuses) experiment test vehicle, which can accommodate up to four concurrent rodlets under separate environmental conditions. Ongoing efforts are necessary in preparation of transient testing support for Accident Tolerant Fuel (ATF) characterization and other future fuels testing requirements. The power coupling factor (PCF) is one of two key parameters utilized in designing and characterizing the performance of a TREAT fuel irradiation experiment. The second key parameter is the Transient Correction Factor (TCF) which accounts for time-dependent effects. The PCF is the effective quantity of fission-generated energy per mass of fuel specimen per total core energy. The quantity of energy deposited into a fuel rodlet under various test environments can be used to evaluate overall fuel performance, including failure mechanisms and thresholds. Baseline fuel rodlet calculations have been performed to estimate the effectiveness of the Multi-SERTTA test vehicle and optimization of PCF for various test conditions. The baseline serves as reference fuel pin conditions against which calibration and baseline experiments can be performed prior to actual ATF transient testing. Baseline experiments further serve to validate computational analyses and experimental test methods prior to design planning, experimentation, and evaluation of the ATF candidates. This paper serves to document activities performed to evaluate a reference Pressurized Water Reactor (PWR) rodlet design in the TREAT Multi-SERTTA test vehicle. (authors)

42 ENGINEERING↗

SU-E-T-381: Evaluation of Calculated Dose Accuracy for Organs-At-Risk Located at Out-Of-Field in a Commercial Treatment Planning System for High Energy Photon Beams Produced From TrueBeam Accelerators

Purpose: Dose calculation accuracy for the out-of-field dose is important for predicting the dose to the organs-at-risk when they are located outside primary beams. The investigations on evaluating the calculation accuracy of treatment planning systems (TPS) on out-of-field dose in existing publications have focused on low energy (6MV) photon. This study evaluates out-of-field dose calculation accuracy of AAA algorithm for 15MV high energy photon beams. Methods: We used the EGSnrc Monte Carlo (MC) codes to evaluate the AAA algorithm in Varian Eclipse TPS (v.11). The incident beams start with validated Varian phase-space sources for a TrueBeam linac equipped with Millennium 120 MLC. Dose comparisons between using AAA and MC for CT based realistic patient treatment plans using VMAT techniques for prostate and lung were performed and uncertainties of organ dose predicted by AAA at out-of-field location were evaluated. Results: The results show that AAA calculations under-estimate doses at the dose level of 1% (or less) of prescribed dose for CT based patient treatment plans using VMAT techniques. In regions where dose is only 1% of prescribed dose, although AAA under-estimates the out-of-field dose by 30% relative to the local dose, it is only about 0.3% of prescribed dose. For example, the uncertainties of calculated organ dose to liver or kidney that is located out-of-field is <0.3% of prescribed dose. Conclusion: For 15MV high energy photon beams, very good agreements (<1%) in calculating dose distributions were obtained between AAA and MC. The uncertainty of out-of-field dose calculations predicted by the AAA algorithm for realistic patient VMAT plans is <0.3% of prescribed dose in regions where the dose relative to the prescribed dose is <1%, although the uncertainties can be much larger relative to local doses. For organs-at-risk located at out-of-field, the error of dose predicted by Eclipse using AAA is negligible. This work was conducted in part using the resources of Varian research grant VUMC40590-R.

60 APPLIED LIFE SCIENCES↗

ARCHER{sub RT} – A GPU-based and photon-electron coupled Monte Carlo dose computing engine for radiation therapy: Software development and application to helical tomotherapy

Purpose: Using the graphical processing units (GPU) hardware technology, an extremely fast Monte Carlo (MC) code ARCHER{sub RT} is developed for radiation dose calculations in radiation therapy. This paper describes the detailed software development and testing for three clinical TomoTherapy® cases: the prostate, lung, and head and neck. Methods: To obtain clinically relevant dose distributions, phase space files (PSFs) created from optimized radiation therapy treatment plan fluence maps were used as the input to ARCHER{sub RT}. Patient-specific phantoms were constructed from patient CT images. Batch simulations were employed to facilitate the time-consuming task of loading large PSFs, and to improve the estimation of statistical uncertainty. Furthermore, two different Woodcock tracking algorithms were implemented and their relative performance was compared. The dose curves of an Elekta accelerator PSF incident on a homogeneous water phantom were benchmarked against DOSXYZnrc. For each of the treatment cases, dose volume histograms and isodose maps were produced from ARCHER{sub RT} and the general-purpose code, GEANT4. The gamma index analysis was performed to evaluate the similarity of voxel doses obtained from these two codes. The hardware accelerators used in this study are one NVIDIA K20 GPU, one NVIDIA K40 GPU, and six NVIDIA M2090 GPUs. In addition, to make a fairer comparison of the CPU and GPU performance, a multithreaded CPU code was developed using OpenMP and tested on an Intel E5-2620 CPU. Results: For the water phantom, the depth dose curve and dose profiles from ARCHER{sub RT} agree well with DOSXYZnrc. For clinical cases, results from ARCHER{sub RT} are compared with those from GEANT4 and good agreement is observed. Gamma index test is performed for voxels whose dose is greater than 10% of maximum dose. For 2%/2mm criteria, the passing rates for the prostate, lung case, and head and neck cases are 99.7%, 98.5%, and 97.2%, respectively. Due to specific architecture of GPU, modified Woodcock tracking algorithm performed inferior to the original one. ARCHER{sub RT} achieves a fast speed for PSF-based dose calculations. With a single M2090 card, the simulations cost about 60, 50, 80 s for three cases, respectively, with the 1% statistical error in the PTV. Using the latest K40 card, the simulations are 1.7–1.8 times faster. More impressively, six M2090 cards could finish the simulations in 8.9–13.4 s. For comparison, the same simulations on Intel E5-2620 (12 hyperthreading) cost about 500–800 s. Conclusions: ARCHER{sub RT} was developed successfully to perform fast and accurate MC dose calculation for radiotherapy using PSFs and patient CT phantoms.

60 APPLIED LIFE SCIENCES↗

Performance study of atomic tally methods for GPU-accelerated Monte Carlo dose calculation - 25352

Over the past several years, the graphics processing unit (GPU) technology has rapidly gained ground in scientific computing due to its outstanding performance and programmability. GPU implementation of Monte Carlo radiation transport for dose calculations has been reported by many investigators. The majority of these studies adopted single-precision floating point format because of the higher peak floating point operations per second (FLOPS) the GPUs can deliver than double-precision. It has been known that calculation using single-precision is more prone to numerical round-off errors, especially when a single tally data is accumulated 'atomically' and repeatedly by thousands of GPU threads. To mitigate this problem, the least intrusive solution in theory is to replace the single-precision atomic-add tally function with a double-precision version. However, the complexity lies in the fact that some GPUs (Nvidia GPUs prior to the Pascal generation; all current AMD GPUs) do not readily offer such double-precision function at hardware level, and that software emulation is too slow to use if not optimized properly. This paper discusses several atomic-add tally methods with reduced numerical errors used throughout ARCHER development. The original software-based compare-and-swap method (CAS) was shown to be inefficient due to high intra-warp thread contention, whereas the improved software-based warp-aggregated method (WAG) and Kahan summation method (KAS) eliminated the thread contention and performed very well on Kepler and Maxwell GPUs, being more than 13 times faster than CAS in our tests. The hardware-based (HB) double-precision atomic-add feature available on Pascal and Volta GPUs exceeded software emulation and offered the best performance universally, so did WIB, a combination of WAG and HB methods. It was also shown that in a single-precision dose engine, KAS managed to maintain high reliability when the single-precision atomic-add tally underestimated the dose by 25%. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A multiphysics model of the versatile test reactor based on the MOOSE framework

The traditional modeling approach for sodium fast reactor cores relies on separate physics models, where the fuel performance, thermal–hydraulics, and neutronics calculations required to predict the core physics characteristics for nominal conditions are decoupled by relying on user-imposed boundary conditions. Here, this paper aims at evaluating the impact of multiphysics simulations for predicting the core characteristics of the Versatile Test Reactor, which is being designed as a 300-MWt sodium-cooled fast reactor. The purpose of the Versatile Test Reactor is to accelerate the testing of advanced nuclear materials in the United States. The proposed multiphysics model relies on the Griffin reactor physics code, the SAM thermal–hydraulic system code, the BISON fuel performance code, as well as generic Multiphysics Object-Oriented Simulation Environment capabilities implemented in the open-source tensor mechanics module. For k eff calculations, the introduction of a tight coupling between the neutronics, thermo-mechanical and thermal–hydraulics models induces a change of around 543 pcm in the eigenvalue, compared to the traditional standalone neutronics calculation where approximate temperature profiles are used. The multiphysics model is then employed for quantifying the impact of the thermal conductivity uncertainties on some of the key figures of merit, such as the fuel centerline temperature, assembly powers, and keff for nominal core conditions. As anticipated, uncertainties on fuel thermal conductivity mostly impact the fuel centerline temperature, and to a lesser extend the k eff .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗