Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Measuring Large Amplitude Surface Figure Error using Coordinate Metrology

Advances in optical testing are as important as advances in optical fabrication, because one can make only what one can measure, particularly for unconventional prescriptions, like aspheric and freeform optics. A new, high-precision metrology capability is utilized to close the gap between interferometric testing and lower precision, contact-probe-based coordinate measuring machines or laser tracker/radar metrology to accurately measure surfaces with large figure error. This nearly universal optical testing method employs an ultra-precision coordinate measuring machine equipped with a non-contact probe. It was developed to characterize a broad spectrum of optical surfaces including ones with high slopes, impossible to measure using traditional interferometric testing. Optical components, covering a wide range of prescriptions, such as large convex conics, high-sloped aspherics, grazing-incidence x-ray optics, and highly deformed flats, were successfully measured. The resulting data were reduced using custom-developed routines to determine the optic’s alignment, surface departure from design, and the as-built optical prescription. This information guided the fabrication and modeling of these optical components

Manal Khreishi↗

Quantification of beam complexity in intensity-modulated radiation therapy treatment plans

Purpose: Excessive complexity in intensity-modulated radiation therapy (IMRT) plans increases the dose uncertainty, prolongs the treatment time, and increases the susceptibility to changes in patient or target geometry. To date, the tools for quantitative assessment of IMRT beam complexity are still lacking. In this study, The authors have sought to develop metrics to characterize different aspects of beam complexity and investigate the beam complexity for IMRT plans of different disease sites. Methods: The authors evaluated the beam complexity scores for 65 step-and-shoot IMRT plans from three sites (prostate, head and neck, and spine) and 26 volumetric-modulated arc therapy (VMAT) plans for the prostate. On the basis of the beam apertures and monitor unit weights of all segments, the authors calculated the mean aperture area, extent of aperture shape irregularity, and degree of beam modulation for each beam. Then the beam complexity values were averaged to obtain the complexity metrics of the IMRT plans. The authors studied the correlation between the beam complexity metrics and the quality assurance (QA) results. Finally, the effects of treatment planning parameters on beam complexity were studied. Results: The beam complexity scores were not uniform among the prostate IMRT beams from different gantry angles. The lateral beams had larger monitor units and smaller shape irregularity, while the anterior-posterior beams had larger modulation values. On average, the prostate IMRT plans had the smallest aperture irregularity, beam modulation, and normalized monitor units; the head and neck IMRT plans had large beam irregularity and beam modulation; and the spine stereotactic radiation therapy plans often had small beam apertures, which may have been associated with the relatively large discrepancies between planned and QA measured doses. There were weak correlations between the beam complexity scores and the measured dose errors. The prostate VMAT beams showed greater complexity than the prostate step-and-shoot IMRT beams. In the treatment planning process, the beam complexity increased as the minimum segment area decreased and as the number of optimization iterations and the maximum number of segments increased. Conclusions: The proposed metrics were effective in characterizing the beam complexity of different disease sites and for different treatment modalities. Efforts should be made to reduce the unnecessary complexity of IMRT beams to minimize the radiation dose uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sideslip-induced static pressure errors in flight-test measurements

During lateral flight-test maneuvers of a V/STOL research aircraft, large errors in static pressure were observed. An investigation of the data showed a strong correlation of the pressure record with variations in sideslip angle. The sensors for both measurements were located on a standard air-data nose boom. An algorithm based on potential flow over a cylinder that was developed to correct the pressure record for sideslip-induced errors is described. In order to properly apply the correction algorithm, it was necessary to estimate and correct the lag error in the pressure system. The method developed for estimating pressure lag is based on the coupling of sideslip activity into the static ports and can be used as a standard flight-test procedure. The estimation procedure is discussed and the corrected static-pressure record for a typical lateral maneuver is presented. It is shown that application of the correction algorithm effectively attenuates sideslip-induced errors.

Parks, Edwin K.↗

Global and Local Distortion Inference During Embedded Zerotree Wavelet Decompression

This paper presents algorithms for inferring global and spatially local estimates of the squared-error distortion measures for the Embedded Zerotree Wavelet (EZW) image compression algorithm. All distortion estimates are obtained at the decoder without significantly compromising EZW's rate-distortion performance. Two methods are given for propagating distortion estimates from the wavelet domain to the spatial domain, thus giving individual estimates of distortion for each pixel of the decompressed image. These local distortion estimates seem to provide only slight improvement in the statistical characterization of EZW compression error relative to the global measure, unless actual squared errors are propagated. However, they provide qualitative information about the asymptotic nature of the error that may be helpful in wavelet filter selection for low bit rate applications.

Huber, A. Kris↗

Sideslip-induced static pressure errors in flight-test measurements

During lateral flight-test maneuvers of a V/STOL research aircraft, large errors in static pressure were observed. An investigation of the data showed a strong correlation of the pressure record with variations in sideslip angle. The sensors for both measurements were located on a standard air-data nose boom. This paper descries an algorithm based on potential flow over a cylinder that was developed to correct the pressure record for sideslip-induced errors. In order to properly apply the correction algorithm, it was necessary to estimate and correct the lag error in the pressure system. The method developed for estimating pressure lag is based on the coupling of sideslip activity into the static ports and can be used as a standard flight-test procedure. The paper discusses the estimation procedure and presents the corrected static-pressure record for a typical lateral maneuver. It is shown that application of the correction algorithm effectifvely attenuates sideslip-induced errors.

Parks, Edwin K.↗

Bias and spread in extreme value theory measurements of probability of error

Extreme value theory is examined to explain the cause of the bias and spread in performance of communications systems characterized by low bit rates and high data reliability requirements, for cases in which underlying noise is Gaussian or perturbed Gaussian. Experimental verification is presented and procedures that minimize these effects are suggested. Even under these conditions, however, extreme value theory test results are not particularly more significant than bit error rate tests.

Smith, J. G.↗

Single arc tracking errors associated with altimeter measurements

This study investigated the accuracies of orbit determinations in the radial coordinate utilizing currently available tracking systems. The results pinpoint certain areas which are critical for the efficient utilization of altimeter measurements.

Mcgoogan, J. T.↗

An evaluation of errors observed in the measurement of low wind velocities

Measurements of low wind velocities (the absolute value of V sub H is approx. equal to 6 m/s) with a VHF wind profiler can be difficult if ground clutter or other biases in the system dominate in altering the position of the perceived peak in the calculated power spectrum. A variety of methods for ground clutter suppression are used in profiler systems today (Cornish, 1983). An editing method called zero suppression takes the spectral value of selectable number of points (N) on each side of 0 velocity (one point on either side, in this study) and sets them equal to the mean value of the points exterior to the specified N points on either side of 0. Analysis done with the PSU VHF(1) radar, shows that this zero-suppression method can systematically bias horizontal wings V sub H below 6 m/s. With the zero suppression, an artificial increase in absolute wind velocities occurs when the spectral peaks fall within the plus or minus N points of the FFT (personal communication, Strauch, 1985). It was also established that the method artificially decreases the absolute wind velocities inferred from spectral peaks that are outside but near the suppressed region. Comparisons of wind profiles observed with and without zero suppression are given. The range of the biased velocities extends to about plus or minus 6 m/s. Biases have been deduced to be as much as 2 m/s, but more commonly they are on the order of 1.0 m/s.

Williams, S. R.↗

Measurement-based analysis of error latency

This paper demonstrates a practical methodology for the study of error latency under a real workload. The method is illustrated with sampled data on the physical memory activity, gathered by hardware instrumentation on a VAX 11/780 during the normal workload cycle of the installation. These data are used to simulate fault occurrence and to reconstruct the error discovery process in the system. The technique provides a means to study the system under different workloads and for multiple days. An approach to determine the percentage of undiscovered errors is also developed and a verification of the entire methodology is performed. This study finds that the mean error latency, in the memory containing the operating system, varies by a factor of 10 to 1 (in hours) between the low and high workloads. It is found that of all errors occurring within a day, 70 percent are detected in the same day, 82 percent within the following day, and 91 percent within the third day. The increase in failure rate due to latency is not so much a function of remaining errors but is dependent on whether or not there is a latent error.

Chillarege, Ram↗

Determination of the Hubble Space Telescope effective conic-constant error from direct image measurements

Direct measurement of discernible features in the Hubble Space Telescope (HST) imagery has enabled a self-consistent determination to be made of the effective conic constant of HST images taken with planetary camera 6 (PC-6) of the wide field and planetary camera. Before being corrected for the contribution from PC-6, the conic constant is -1.01429 +/- 0.0002. The correction for PC-6 is less accurately determined but probably lies between -0.0002 and 0.0004. As a result the HST optics are characterized best by a conic constant of -1.0140 +/-0.0003 as obtained from direct image measurements.

Meinel, Aden B.↗

Quantifying Spatial Separation Error in Tropospheric Wind Measurements

Wind measurements from the surface through the troposphere are an important asset for both range and Day of Launch (DOL) operations. Weather balloons have long been used to fulfill this operational need. Decker (2017) found balloons at Kennedy Space Center (KSC) can drift as far as 200 km from the launch site. Curtis et al. (2019) found Root Mean Square (RMS) wind deltas between 0.5 m/s and 6.3 m/s for separations between 30 km and 200 km from KSC using the North American Regional Reanalysis (NARR) model. The purpose of this study is to validate the model-based results found in Curtis et al. (2019) with observed wind and separation deltas calculated between the NASA Tropospheric Doppler Radar Wind Profiler (TDRWP) and weather balloons.

Curtis, Nathan↗

High Impedance Fault Detection Through Quasi-Static State Estimation: A Parameter Error Modeling Approach

This paper presents a model for detecting high impedance faults using parameter error modeling and a two step per-phase weighted-least squares state estimation process. The proposed scheme leverages the use of Phasor Measurement Units and synthetic measurements to identify per-phase power flow and injection measurements which indicate a parameter error through ?2 Hypothesis Testing applied to the composed measurement error. Although current and voltage waveforms are commonly analyzed for high-impedance fault detection, wide area power flow and injection measurements, which are already inherent to the state estimation process, also show promise for real-world high-impedance fault detection applications. The error distributions after detection share the measurement function error spread observed in proven parameter error diagnostics and can be applied to high-impedance fault identification. Further, this error spread across measurement functions related to the fault will be clearly discerned from measurement error. Case studies are performed on the IEEE 33-Bus Distribution System along with the proposed model in Simulink.

Cooper, Austin↗

Automated measurement of the bit-error rate as a function of signal-to-noise ratio for microwave communications systems

The performance of microwave systems and components for digital data transmission can be characterized by a plot of the bit-error rate as a function of the signal to noise ratio (or E sub b/E sub o). Methods for the efficient automated measurement of bit-error rates and signal-to-noise ratios, developed at NASA Lewis Research Center, are described. Noise measurement considerations and time requirements for measurement accuracy, as well as computer control and data processing methods, are discussed.

Kerczewski, Robert J.↗

Commissioning of SRF Cavity Analyzer System

Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.

Netepenko, A.↗