Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

ToF-SIMS spectral analysis of Shewanella oneidensis MR-1 biofilms

Analysis of bacterial biofilms is particularly challenging and important with diverse applications from systems biology to biotechnology. Among the variety of techniques that have been applied, time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many powerful features in studying the surface characteristics of biofilms. ToF-SIMS offers high spatial resolution, mass resolution, and mass accuracy, which permit surface sensitive analysis of biofilm components. Thus, ToF-SIMS provides a powerful solution to addressing the challenge of bacterial biofilm analysis. This dataset covers ToF-SIMS analysis of Shewanella oneidensis MR-1 isolated from freshwater lake sediment in New York state. The MR-1 strain is known to have metal and sulfur reducing properties and it can be used for bioremediation and wastewater treatment. There is a current need to identify small molecules and fragments produced from bacterial biofilms, especially those from extracellular polymeric substance (EPS). Static ToF-SIMS spectra of MR-1 were obtained using an IONTOF TOF.SIMS V instrument equipped with a 25 keV Bi$^+_3$ metal ion gun. Identified molecules and molecular fragments are compared against known biological databases and the reported peaks have at least 65 ppm mass accuracy. These molecules range from lipids, fatty acids, flavonoids, and quinolones to other naturally occurring organic compounds. It is anticipated that the mass spectral identification of key peaks will assist detection of metabolites, EPS molecules like polysaccharides, and biologically relevant small organic molecules using ToF-SIMS in future surface and interface research.

59 BASIC BIOLOGICAL SCIENCES↗

Rigor and Reproducibility in Electrocatalysis: Best Practices for Operando Studies

Operando measurements have rapidly expanded the scope of electrocatalysis by enabling direct observation of catalytic interfaces under working conditions and by linking structural, compositional, and spectroscopic observables to activity and selectivity. However, the growth of operando methods has outpaced the adoption of broadly shared experimental standards, creating persistent challenges in reproducibility, interpretation, and comparison across laboratories and platforms. This perspective synthesizes discussions from the 2025 National Science Foundation Workshop on Rigor and Reproducibility in Electrocatalysis and outlines a practical framework for the rigorous use of operando measurements in electrocatalysis. We highlight three recurring needs: careful implementation of complex methods to avoid overinterpretation; recognition that (subtle) differences in reactor architecture, hydrodynamics, and electrical boundary conditions can alter apparent kinetics and selectivity; and transparent reporting standards that enable meaningful cross-comparison without constraining measurement-specific cell innovation. Focusing on widely used techniques (including X-ray and vibrational spectroscopies, mass spectrometry, and electron microscopy), we discuss technique-specific pitfalls, cross-validation strategies, and recurring platform-agnostic considerations such as mass transport, current distribution, temporal-resolution mismatches, and catalyst evolution. This Perspective aims to strengthen the mechanistic inference and improve the reproducibility, comparability, and predictive value of operando electrocatalysis research.

X-ray absorption spectroscopy↗

SPRUCE FT-ICR MS, Bulk Chemistry, and Mass Loss from Litter Decomposition Study in Experimental Plots, Marcell Experimental Forest, Minnesota, 2015-2017

This dataset contains molecular, bulk chemical, and mass loss measurements from a litter decomposition study at the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site within the Marcell Experimental Forest in northern Minnesota, USA. This site is in a Sphagnum spp. ombrotrophic bog forest. Litterbags were deployed into the peat in September 2015 across three warming levels (+0, +4.5, and +9°C) under ambient and elevated carbon dioxide (CO₂ - +500 ppm) and retrieved after roughly 0.5, 1, and 2 years of field incubation (2015-09-23 to 2017-08-02). Litterbags containing six peatland litter types: black spruce needles (Picea mariana - SPL), spruce fine roots (SPR), Sphagnum angustifolium (ANG), Sphagnum magellanicum (MAG), Labrador tea leaves (Rhododendron groenlandicum - LTL), and Labrador tea roots (LTR). Molecular composition of water-soluble organic matter extracts was characterized using Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS) at 9.4 Tesla, operated in negative ion mode with electrospray ionization, providing molecular formula assignments and compound-class distributions across the decomposition time series. Bulk chemical characterization included elemental analysis (percent carbon, nitrogen, and phosphorus) and Fourier Transform Infrared Spectroscopy (FTIR) to quantify functional group composition. Litter mass loss was tracked gravimetrically at each retrieval interval, expressed as percent mass remaining relative to initial dry mass for each litter type and treatment combination. These data are valuable for understanding how vegetation shifts driven by increased atmospheric CO2 and temperature in peatlands alter litter inputs and organic matter stabilization trajectories, with implications for projecting and modeling peatland carbon cycling. This dataset contains two data files in comma-separated value (.csv) format. Additional metadata are provided: two data dictionaries and a file-level metadata file in comma separate (.csv) format and a user guide in PDF (*.pdf) format.

decomposition↗

Ion soft landing: A unique tool for understanding electrochemical processes

Ion soft landing (SL) is a preparative mass spectrometry approach that enables deposition of mass- and charge-selected gaseous ions onto surfaces with controlled kinetic energy. The unique capabilities of SL provide an opportunity to populate electrode–electrolyte interfaces (EEIs) with well-defined intact electroactive ions of known composition, thereby facilitating the characterization of their intrinsic electrochemical properties. Here, in this perspective, we describe the SL technique and discuss how it may be used to study the effect of the charge state, stoichiometry, and composition of large redox active molecules and clusters on their electron transfer kinetics. SL has enabled the characterization of redox-active species that cannot be purified and examined using conventional bulk-phase separation and deposition approaches. Furthermore, precise control over the deposition process provides an opportunity to prepare and characterize well-defined EEIs relevant to energy storage and conversion, catalysis, and sensing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ToF-SIMS spectral data analysis of Paenibacillus sp. 300A biofilms and planktonic cells

Analysis of bacterial biofilms is particularly challenging and important with diverse applications from systems biology to biotechnology. Among the variety of techniques that have been applied, time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying the surface characteristics of biofilms. ToF-SIMS offers high spatial resolution and high mass accuracy, which permit surface sensitive analysis of biofilm components. Thus, ToF-SIMS provides a powerful solution to addressing the challenge of bacterial biofilm analysis. This dataset covers ToF-SIMS analysis of Paenibacillus sp. 300A (300A) isolated from the Hanford site in Richland, WA. The strain is known to have metal and sulfur reducing properties and can be used for bioremediation, wastewater treatment, bioengineering and technology development. There is a current need to identify small molecules and fragments produced from bacterial biofilms. Static ToF-SIMS spectra of 300A were obtained using an IONTOF TOF-SIMS V instrument equipped with a 25 keV Bi 3 + metal ion gun. Identified molecules and molecular fragments are compared against known biological databases and the reported peaks have at least 65 ppm mass accuracy. These molecules range from lipids and fatty acids to flavonoids, quinolones, and other naturally occurring organic compounds. It is anticipated that the spectral identification of key peaks will assist detection of metabolites, extracellular polymeric substance molecules like polysaccharides, and biologically relevant small molecules using ToF-SIMS in future surface and interface research of bacterial biofilms.

Biofilms↗

Quantum Chemistry Calculations for Metabolomics

A primary goal of metabolomics and exposomics studies is to fully characterize the small molecule composition of complex biological and environmental samples. However, despite advances in analytical technologies over the past two decades, the majority of small molecules in complex samples are not readily identifiable due to the immense structural and chemical diversi-ty present within the metabolome and exposome. Current gold-standard identification methods rely on reference libraries built using authentic chemical materials (“standards”), which are not available for most molecules. Computational quantum chemis-try methods, which can be used to calculate chemical properties that are then measured by analytical platforms, offer an alter-native route for building reference libraries, i.e., in silico libraries for “standards-free” identification. In this review, we cover the major roadblocks currently facing metabolomics and discuss applications where quantum chemistry calculations offer a solu-tion. Several successful examples for nuclear magnetic resonance spectroscopy, ion mobility spectrometry, infrared spectros-copy, and mass spectrometry methods are reviewed. Finally, we consider current best practices, sources of error, and provide an outlook for quantum chemistry calculations in metabolomics and exposomics studies. We expect this review will inspire researchers in the field of small molecule identification to accelerate adoption of in silico methods for generation of reference libraries and to add quantum chemistry calculations as another tool at their disposal to characterize complex samples.

Metabolism↗

Plasma proteomic biomarkers of physical frailty in heart failure: a propensity score matched discovery-based pilot study

Background: Physical frailty is highly prevalent in heart failure (HF), but we lack an understanding of the underlying pathophysiology. Proteomics evaluation of plasma samples may elucidate potential mechanisms and biomarkers of physical frailty in HF. We aimed to identify plasma proteomic biomarkers that are differentially expressed between physically frail and non physically frail adults with HF. Methods: This was a secondary analysis of a subset of data and plasma samples from a study of frailty among patients with New York Heart Association (NYHA) Functional Classification I-IV HF. Physical frailty was measured using the Frailty Phenotype Criteria. Propensity score matching was used to match pairs of physically frail (n = 20) vs. non-physically frail (n = 20) patients on clinical characteristics. Plasma samples were processed using a sensitive liquid chromatography mass spectrometry platform, utilizing a multiplexed tandem mass tag-labeled quantitative proteomics approach. Differentially expressed proteins were quantified individually using paired t tests with associated log fold change of 0.3 and Fisher’s combined p values. Results: The sample (n = 40) was 62.8±16.9 years old, 58% female, and 55% NYHA Class III/IV. Proteomics analysis revealed 7 proteins differentially expressed using full differential criteria: matrix metalloproteinase-14 was downregulated in frailty, and copine-1, low affinity immunoglobulin gamma Fc region receptor III-A and III-B, probable non-functional immunoglobulin kappa variable 2D-24, glutathione S-transferase Mu 1, and argininosuccinate lyase were upregulated in frailty. Conclusions: Proteomic biomarkers related to the immune system, stress response, and detoxification were differentially expressed between physically frail and non-physically frail adults with HF.

Biomarkers↗

Investigation of U content in J-swipe/PIC samples

This final report documents the results of an evaluation of the U content in J-swipes for the International Atomic Energy Agency (IAEA). J-swipes are manufactured with inked numbers (1–30) and U backgrounds that are considered consistent across different lots and manufacturing times. These characteristics make them ideal for use by IAEA inspectors for pre-inspection check samples to ensure inspectors are not cross-contaminating sites. However, recent work has found elevated U concentrations in the inked numbers compared with the J-swipe material. To determine whether the inked numbers correlate with the U backgrounds, triplicate U content measurements were made on Swipes 1, 2, 11, 22, and 28. Triplicates of each swipe were processed through the standard chemistry used by the Oak Ridge National Laboratory Network of Analytical Laboratories team and analyzed for U content by isotope dilution via multicollector inductively coupled plasma mass spectrometry. Finally, samples were made by mass consisting of only ink areas and only cotton swipe material to determine the trace element differences between the cotton and the ink.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Results from a multi-laboratory ocean metaproteomic intercomparison: effects of LC-MS acquisition and data analysis procedures

Metaproteomics is an increasingly popular methodology that provides information regarding the metabolic functions of specific microbial taxa and has potential for contributing to ocean ecology and biogeochemical studies. A blinded multi-laboratory intercomparison was conducted to assess comparability and reproducibility of taxonomic and functional results and their sensitivity to methodological variables. Euphotic zone samples from the Bermuda Atlantic Time-series Study (BATS) in the North Atlantic Ocean collected by in situ pumps and the autonomous underwater vehicle (AUV) Clio were distributed with a paired metagenome, and one-dimensional (1D) liquid chromatographic data-dependent acquisition mass spectrometry analysis was stipulated. Analysis of mass spectra from seven laboratories through a common bioinformatic pipeline identified a shared set of 1056 proteins from 1395 shared peptide constituents. Quantitative analyses showed good reproducibility: pairwise regressions of spectral counts between laboratories yielded R 2 values averaged 0.62±0.11, and a Sørensen similarity analysis of the top 1000 proteins revealed 70 %–80 % similarity between laboratory groups. Taxonomic and functional assignments showed good coherence between technical replicates and different laboratories. A bioinformatic intercomparison study, involving 10 laboratories using eight software packages, successfully identified thousands of peptides within the complex metaproteomic datasets, demonstrating the utility of these software tools for ocean metaproteomic research. Lessons learned and potential improvements in methods were described. Future efforts could examine reproducibility in deeper metaproteomes, examine accuracy in targeted absolute quantitation analyses, and develop standards for data output formats to improve data interoperability. Together, these results demonstrate the reproducibility of metaproteomic analyses and their suitability for microbial oceanography research, including integration into global-scale ocean surveys and ocean biogeochemical models.

59 BASIC BIOLOGICAL SCIENCES↗

Hydrogen and helium ions

Hydrogen and helium ions - Theoretical considerations and observations obtained by ion mass spectrometry on spacecraft, ground-based backscatter, and VLF observations on satellites

BACKSCATTER↗

Analysis of chemical components from plant tissue samples

Information is given on the type and concentration of sterols, free fatty acids, and total fatty acids in plant tissue samples. All samples were analyzed by gas chromatography and then by gas chromatography-mass spectrometry combination. In each case the mass spectral data was accumulated as a computer printout and plot. Typical gas chromatograms are included as well as tables describing test results.

Laseter, J. L.↗

The in situ exobiological investigation of the Martian surface mineralogy during unmanned missions

An important goal of exobiological research is to determine if life arose on planets other than Earth. The only other planet known, to date, on which life may have arisen is Mars. The data suggest that the physical environment of early Mars (i.e., temperature, pressure, and radiation regimes) was suitable for life to arise. Thus far, the data also suggest that early Mars possessed sufficient quantities of the required building blocks and a number of the chemical compounds necessary for life to arise. It is not known, however, if water existed in the appropriate state (i.e., liquid) in sufficient quantities long enough for life to arise. Determining the mineralogy and components of the Martian soil through in situ analyses during missions to Mars will provide information from which an assessment can be made for the probability of the origin of life on Mars. Missions to Mars in the near future will be unmanned and capable of in situ analyses. Our studies have shown that differential thermal analysis coupled with gas chromatography (DTA/GC) is a more appropriate analytical technique than, x-ray fluorescence, x-ray diffraction, alpha-proton backscatter, gamma-ray spectrometry, differential scanning calorimetry coupled with mass spectrometry (DSC/MS), or DSC/GC to identify the mineralogy of the Martian surface material in situ. DTA/GC is an advancement over the pyrolytic techniques flown on previous missions that have supplied only limited mineralogical information (Biemann et al. 1977).

Mancinelli, Rocco L.↗

Angular scattering of protons through ultrathin graphene foils: Application for time-of-flight instrumentation

Space plasma instruments often rely on ultrathin carbon foils for incident ion detection, time-of-flight (TOF) mass spectrometry, and ionization of energetic neutral atoms. Angular scattering and energy loss of ions or neutral atoms in the foil can degrade instrument performance, including sensitivity and mass resolution; thus, there is an ongoing effort to manufacture thinner foils. Using new 3-layer graphene foils manufactured at the Los Alamos National Laboratory, we demonstrate that these are the thinnest foils reported to date and discuss future testing required for application in space instrumentation. We characterize the angular scattering distribution for 3–30 keV protons through the foils, which is used as a proxy for the foil thickness. We show that these foils are ~2.5–4.5 times thinner than the state-of-the-art carbon foils and ~1.6 times thinner than other graphene foils described in the literature. We find that the inverse relationship between angular scattering and energy no longer holds, reaffirming that this may indicate a new domain of beam–foil interactions for ultrathin (few-layer) graphene foils.

47 OTHER INSTRUMENTATION↗

Lunar atmospheric measurements

Maximum densities and gaseous contents of lunar atmosphere - use of optical or mass spectrometry for translunar, lunar orbit, transearth, and lunar surface phases of Apollo mission

GAS COMPOSITION↗