Rotation of images by scan mirrors

An analysis is presented of the effects of scan mirrors on scene orientation or rotation for image forming systems. Some simple vector relationships are presented, which when combined with the anticipated application conditions, make it possible to easily assess image orientation effects resulting from scan mirrors. Examples are cited to demonstrate the application of the analysis.

Katzberg, Stephen J.↗

Design of a grating spectrometer from a 1:1 Offner mirror system

A 1:1 Offner mirror system is modified to work as a grating spectrometer for the infrared by placing a grating on the secondary convex mirror of the system. Slight adjustment of the configuration combined with tilt of the secondary provide the necessary degrees of freedom to correct for astigmatism of the system. Additional control may be obtained by using a holographic optical element (HOE), constructed to add necessary compensating aberrations. Details of the best configuration and the limitations of performance are presented.

Kwo, Deborah↗

Operation of a deformable mirror device as a Fourier plane phase modulating filter

The operation of a deformable mirror device (DMD) as a Fourier plane phase modulating filter is described. An analysis of the optical characteristics of the DMD elements as phase modulators is summarized. Analytical and experimental results indicating the existence of a quasi-phase-only operational mode are presented. These results are used to specify the mirror deflection required to implement a binary phase-only image correlation operation. An optical correlator system is implemented using the DMD Fourier plane filter and experimental results from this system are compared with computer simulations of the correlator operation.

Florence, James M.↗

A multilayer X-ray mirror for solar photometric imaging flown on a sounding rocket

The flight of a multilayer-coated mirror on a sounding rocket experiment on March 17, 1988 which was used to obtain photometric images of the sun just prior to solar eclipse is discussed. The rocket payload and the choice of passband are described. The design of the multilayer, the fabrication of the mirror, and the reflectance measurements are addressed.

Haisch, B. M.↗

Measurement of total hemispherical emissivity of contaminated mirror surfaces

The effects of dust contamination on the total hemispherical emissivity (THE) of a 1.5-inch-diameter Al/MgF2-coated telescope mirror are investigated experimentally. The THE is determined by means of cooling-rate measurements in the temperature range 10-14.5 C in a vacuum of 100 ntorr or better. Photographs and drawings of the experimental setup are provided, and results for 11 dust levels are presented in tables and graphs. It is shown that dust has a significant effect on THE, but the experimental losses are only about half those predicted for perfectly black dust in perfect thermal contact with the mirror surface.

Facey, T. A.↗

Aspheric doublets and precision adjustable fold mirrors for 20 K operation in CLAES

A cooled, infrared spectrometer is required to operate in earth orbit. The spectrometer performance requirements are discussed to show how package volume constraints and the stressing environment of cryogenic operation affect the detailed design of spectrometer components such as relay imaging optics and fold mirrors. Design steps are described that were taken to insure that the spectrometer would perform well in orbit, with components that are easily manufactured, readily aligned and stable in operation. This design procedure has produced two components of special interest, fast doublets suitable for use at 20 K over the wavelength band from 3.5 to 12 microns, and fold mirrors that can be adjusted to arc second tolerances.

Zinky, William R.↗

Measurement of the point spread function and effective area of the Solar-A Soft X-ray Telescope mirror

A grazing incidence solar X-ray telescope, Soft X-ray Telescope (SXT), will be flown on the Solar-A satellite in 1991. Measurements have been conducted to determine the focal length, Point Spread Function (PSF), and effective area of the SXT mirror. The measurements were made with pinholes, knife edges, a CCD, and a proportional counter. The results show the 1/r character of the PSF, and indicate a half power diameter of 4.9 arcsec and an effective area of 1.33 sq cm at 13.3 A (0.93 keV). The mirror was found to provide a high contrast image with very little X-ray scattering.

Lemen, J. R.↗

Development Of Composite Panels For Telescope Mirrors

Report describes continuing program for development of lightweight hexagonal graphite/epoxy composite panels intended to support precisely curved mirror surfaces assembled into large telescope mirror. Discusses development requirements, technical decisions, fabrication methods, measurements of properties of materials, analytical simulation, and thermal vacuum testing. Telescope flown in orbit around Earth to observe at wavelengths down to 30 micrometers.

Freeland, Robert E.↗

Conical Mirrors For Quasi-Retroreflection

Single and multiple-nested conical mirrors assembled and positioned to provide several distinct orders of retroreflection. Design and orientation of "cones" determines positions of, and solid angles subtended by discrete orders of retroreflection. Accommodates larger range of incident angles than corner-cube reflectors. Also provides greater spectral coverage than conventional lens-and mirror retroreflectors. Potential applications include interferometry, metrology, lasers, position and motion sensors, instrument test and calibration, and expanded capability of highway markers and signs.

Dekany, Richard G.↗

Hubble Space Telescope secondary mirror vertex radius/conic constant test

The Hubble Space Telescope backup secondary mirror was tested to determine the vertex radius and conic constant. Three completely independent tests (to the same procedure) were performed. Similar measurements in the three tests were highly consistent. The values obtained for the vertex radius and conic constant were the nominal design values within the error bars associated with the tests. Visual examination of the interferometric data did not show any measurable zonal figure error in the secondary mirror.

Parks, Robert↗

Procedure for computer-controlled milling of accurate surfaces of revolution for millimeter and far-infrared mirrors

A simple method for milling accurate off-axis parabolic mirrors with a computer-controlled milling machine is discussed. For machines with a built-in circle-cutting routine, an exact paraboloid can be milled with few computer commands and without the use of the spherical or linear approximations. The proposed method can be adapted easily to cut off-axis sections of elliptical or spherical mirrors.

Emmons, Louisa↗

Design of a prototype secondary mirror assembly for the Space Infrared Telescope Facility

The design of a liquid helium temperature prototype secondary mirror assembly (PSMA) under development for the NASA Space Infrared Telescope Facility (SIRTF) program is described. The SIRTF assembly must operate below 4 K and provide the functions of highly precise two-axis periodic tilting ('chopping') in addition to the conventional functions of focus and collimation adjustment. The PSMA design employs a fused quartz mirror kinematically attached at its center to an aluminum cruciform. The mirror/cruciform assembly is driven in tilt about its combined center of mass using an aluminum flexure pivot of unique design and a four-actuator control system with feedback provided by pairs of differential position sensors. The voice coil actuators are mounted on a second flexure-pivoted mass to enhance servosystem stability and isolate the telescope from vibration-induced disturbances. The mirror/cruciform and reaction mass are attached to opposite sides of an aluminum mounting plate whose position relative to the outer housing is controlled by a six-degree-of-freedom focus and centering mechanism using pivoted actuation levers driven by lead screw/harmonic drive/stepper motor assemblies.

Stier, Mark T.↗

Development of structural composite mirror technology for submillimeter space telescopes

The technical approach to the design, manufacturing, testing, and analytical simulation of lightweight graphite/epoxy mirrors is described. The precision segmented reflector (PSR) program has produced (1) 1.0-m graphite/epoxy panels with areal densities of 7 kg/sq m as-manufactured surface precision near 1 micron rms, (2) 0.5-m panels with figure changes less than 1 micron rms for temperature reductions of 100 K, (3) analytical performance-prediction capability with submicron accuracy relative to panel thermal distortion, and (4) a unique thermal vacuum test facility for structural composite mirrors.

Freeland, R. E.↗

Design of a compliant passive magnetic bearing for use in SIRTF's Tertiary Mirror Assembly

A proposed baseline design for the Space Infrared Telescope Facility includes a Tertiary Mirror Assembly (TMA) which selectively redirects the telescope's converging science beam to each of several instruments. The TMA's mirror rotates on an axis coincident with the beam's axis, and is held steady during observation by a kinematic mount. A bearing has been designed whose compliance causes minimal interference with the precision of the kinematic mount, and which is well suited to the particular requirements of a cryogenic satellite such as SIRTF. The bearing suspends its rotor by taking advantage of the repulsion between a superconductor and a magnet. It potentially eliminates problems associated with mechanical bearings that arise in similar applications, such as lubricant loss or failure, bearing wear, and sensitivity to particulates, and does so without imposing the thermal load of a bearing heater or active magnetic bearing. The bearing shows promise of offering an alternative to ball bearings in cryogenic applications where some compliance is acceptable or advantageous.

Cannon, David M.↗

Piezoelectrically Bendable Mirrors For Spatial Modulation Of Light

Flexible mirrors including multiple small piezoelectric actuators (bimorphs) attached to back surfaces developed. Weigh less, respond faster, actuated by lower voltages, and include larger numbers of bending actuators for finer control of surface contours. Mirrors used as spatial light modulators in optical computers, to compensate for atmospheric distortions in astronomical telescopes, and in other applications in which wave fronts altered controllably.

Ribak, Erez N.↗

Design and analysis of a fast, two-mirror soft-x-ray microscope

During the past several years, a number of investigators have addressed the design, analysis, fabrication, and testing of spherical Schwarzschild microscopes for soft-x-ray applications using multilayer coatings. Some of these systems have demonstrated diffraction limited resolution for small numerical apertures. Rigorously aplanatic, two-aspherical mirror Head microscopes can provide near diffraction limited resolution for very large numerical apertures. The relationships between the numerical aperture, mirror radii and diameters, magnifications, and total system length for Schwarzschild microscope configurations are summarized. Also, an analysis of the characteristics of the Head-Schwarzschild surfaces will be reported. The numerical surface data predicted by the Head equations were fit by a variety of functions and analyzed by conventional optical design codes. Efforts have been made to determine whether current optical substrate and multilayer coating technologies will permit construction of a very fast Head microscope which can provide resolution approaching that of the wavelength of the incident radiation.

Shealy, D. L.↗

Image analysis of the AXAF VETA-I x ray mirror

Initial core scan data of the VETA-I x-ray mirror proved disappointing, showing considerable unpredicted image structure and poor measured FWHM. 2-D core scans were performed, providing important insight into the nature of the distortion. Image deconvolutions using a ray traced model PSF was performed successfully to reinforce our conclusion regarding the origin of the astigmatism. A mechanical correction was made to the optical structure, and the mirror was tested successfully (FWHM 0.22 arcsec) as a result.

Freeman, Mark D.↗

Surface finish quality of the outer AXAF mirror pair based on x ray measurements of the VETA-I

We employ the X-ray measurements of the VETA-I taken at the X-Ray Calibration Facility (XRCF) of the Marshall Space Flight Center (MSFC) to extract information about the surface finish quality of the outermost pair of AXAF mirrors. The particular measurements we consider are one dimensional scans of the core of the point response function (PRF) (full width half maximum (FWHM) scans), the encircled energy as a function of radius, and one dimensional scans of the wings of the PRF. We discuss briefly our ray trace model which incorporates the numerous effects present in the VETA-I test, such as the finite source distance, the size and shape of the X-ray source, the residual gravitational distortions of the optic, the despace of the VETA-I, and particulate contamination. We show how the data constrain the amplitude of mirror surface deviations for spatial frequencies greater than about 0.1 mm(exp -1). Constraints on the average amplitude of circumferential slope errors are derived as well.