Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Distribution Grid Impacts of Community Solar [Slides]

Community solar (CS) projects often face uncertain interconnection costs and fees associated with distribution grid infrastructure upgrades required to connect the project. These costs can determine the economic viability of a CS project, but they are difficult to assess. Cost uncertainty can discourage new projects and prevent communities from accessing the benefits of community solar projects. At the same time, CS deployment strategies hold potential to defer or avoid some distribution costs due to new loads. To mitigate CS interconnection costs, it is important to find least-cost combinations of distribution system infrastructure solutions (transformer upgrades, reconductoring, voltage regulators, storage), and to understand how location of CS projects within a feeder impact distribution grid upgrade costs. This study aims to quantify CS impacts on the distribution grid and provide policy and regulatory insights and CS deployment strategies to address them. It is the first analysis that has systematically studied the technical impacts of community solar projects on a wide range of distribution feeders using state-of-the-art optimization and power flow tools. The analysis employs Berkeley Lab’s novel Least-cost Optimal Distribution Grid Expansion (LODGE) model, a deterministic version of the REPAIR model, that optimally upgrades hundreds or even thousands of distribution circuits or feeders. This is the first application of the LODGE model. LODGE finds the least-cost portfolio of traditional distribution system upgrades to integrate CS in combination with alternative solutions, such as utility-owned storage and downsizing CS capacity. Working with a set of least-cost solutions per feeder allows us to benchmark, compare and find techno-economic trends in CS interconnection.

14 SOLAR ENERGY↗

The effect of load sequence on the statistical fatigue of composites

A theoretical model to predict the effect of loading sequence on the statistical distributions of the fatigue life and the residual strength under n-stress levels of cyclic loading is derived on the basis of a three-parameter model. In particular, the dual stress fatigue cumulative damage is studied, showing that the Miner's sum (the cumulative damage sum at fatigue failure) is a statistical variable. It is proved theoretically that the Miner's sum is always greater than or equal to unity for the high-low load sequence, while it is always smaller than or equal to unity for the low-high load sequence, with the deviation from unity increasing as the difference between the high and the low stress levels increases. An experimental test program using graphite/epoxy angle-ply laminates, carried out to generate statistically meaningful data for verifying the proposed model, is discussed.

Yang, J. N.↗

Harmonic cancellation within AC low voltage distribution for a realistic office environment

An increase of non-linear loads, primarily from power electronics, has substantially increased current harmonics in commercial buildings, which contributes to decreased transformer efficiency / lifespan and poor power quality. This study uses recorded power consumption data from common miscellaneous electric loads (MELs) seen in offices, combined with detailed characterizations of example MELs, to simulate harmonic cancellation within building circuits. Typically, harmonic cancellation studies assume that AC converters operate across their rated power range. However, this study finds that common MELs operate below 40% of rated power the majority of the time when not quiescent; 89% of sampled devices never operated above 60% of rated power. Simulations using these more realistic power levels indicate current-harmonic cancellation (3rd to 13th harmonic) is significantly lower than that predicted when using full-range power assumptions, resulting in minor errors for low-order harmonics and larger errors for higher order harmonics. Furthermore, increased MELs load diversity increases harmonic cancellation, but insufficiently to eliminate errors. In contrast, blending lighting loads with MELs on the secondaries of distribution transformers improves harmonic cancellation to near those predicted by traditional methods. These results indicate that realistic power levels, as well as better characterization of harmonics from typical MELs, should be used to estimate harmonic cancellation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Longitudinally Jointed Edge-Wise Compression HoneyComb Composite Sandwich Coupon Testing And Fe Analysis: Three Methods of Strain Measurement, And Comparison

Three distinct strain measurement methods (i.e., foil resistance strain gages, fiber optic strain sensors, and a three-dimensional digital image photogrammetry that gives full field strain and displacement measurements) were implemented to measure strains on the back and front surfaces of a longitudinally jointed curved test article subjected to edge-wise compression testing, at NASA Goddard Space Flight Center, according to ASTM C364. The pre-test finite element analysis (FEA) was conducted to assess ultimate failure load and predict strain distribution pattern throughout the test coupon. The predicted strain pattern contours were then utilized as guidelines for installing the strain measurement instrumentations. The foil resistance strain gages and fiber optic strain sensors were bonded on the specimen at locations with nearly the same analytically predicted strain values, and as close as possible to each other, so that, comparisons between the measured strains by strain gages and fiber optic sensors, as well as the three-dimensional digital image photogrammetric system are relevant. The test article was loaded to failure (at ~167 kN), at the compressive strain value of ~10,000 micro epsilon. As a part of this study, the validity of the measured strains by fiber optic sensors is examined against the foil resistance strain gages and the three-dimensional digital image photogrammetric data, and comprehensive comparisons are made with FEA predictions.

Farrokh, Babak↗

Adaptive domain decomposition for Monte Carlo simulations on parallel processors

A method is described for performing direct simulation Monte Carlo (DSMC) calculations on parallel processors using adaptive domain decomposition to distribute the computational work load. The method has been implemented on a commercially available hypercube and benchmark results are presented which show the performance of the method relative to current supercomputers. The problems studied were simulations of equilibrium conditions in a closed, stationary box, a two-dimensional vortex flow, and the hypersonic, rarefield flow in a two-dimensional channel. For these problems, the parallel DSMC method ran 5 to 13 times faster than on a single processor of a Cray-2. The adaptive decomposition method worked well in uniformly distributing the computational work over an arbitrary number of processors and reduced the average computational time by over a factor of two in certain cases.

Wilmoth, Richard G.↗

Adaptive domain decomposition for Monte Carlo simulations on parallel processors

A method is described for performing direct simulation Monte Carlo (DSMC) calculations on parallel processors using adaptive domain decomposition to distribute the computational work load. The method has been implemented on a commercially available hypercube and benchmark results are presented which show the performance of the method relative to current supercomputers. The problems studied were simulations of equilibrium conditions in a closed, stationary box, a two-dimensional vortex flow, and the hypersonic, rarefied flow in a two-dimensional channel. For these problems, the parallel DSMC method ran 5 to 13 times faster than on a single processor of a Cray-2. The adaptive decomposition method worked well in uniformly distributing the computational work over an arbitrary number of processors and reduced the average computational time by over a factor of two in certain cases.

Wilmoth, Richard G.↗

FLEXSTAB: A computer program for the prediction of loads and stability and control of flexible aircraft

Capabilities of the FLEXSTAB Computer Program System are described and illustrated. Aeroelastic analysis of a wide variety of aircraft configurations is performed. The aerodynamic theory used in FLEXSTAB is applicable to both steady and unsteady, subsonic and supersonic flow for multiple wing-body tail nacelle configurations with a plane of symmetry. For unsteady flow calculations, an unsteady aerodynamic theory is used which is appropriate for the low reduced frequencies associated with aircraft flight dynamics. The aircraft is modeled as either a rigid or flexible structure. The computer trims the aircraft in steady reference flight and computes both static and dynamic stability and control derivatives and the stability behavior about the trim condition. The airplane lifting pressure distribution, aerodynamic and inertia loads and deflected shape are also computed.

Perkin, B. R.↗

A novel large-scale EV charging scheduling algorithm considering V2G and reactive power management based on ADMM

Electric vehicle aggregators (EVAs) that utilize vehicle-to-grid (V2G) technologies can function as both controllable loads and virtual power plants, providing key energy management services to the distribution system operator (DSO). EVAs can also balance the grid’s reactive power as a virtual static VAR compensator (SVC) and provide voltage stability by utilizing advanced electric vehicle (EV) chargers that are capable of four-quadrant operations to provide reactive power management. Finally, managed charging can benefit EVAs themselves by minimizing power factor penalties in their electricity bills. In this paper, we propose a novel EV charging scheduling algorithm based on a hierarchical distributed optimization framework that minimizes peak load and provides reactive power compensation for the DSO by collaboration with EVAs that manage both the active and the reactive charging and discharging power of participating EVs. Utilizing the alternative direction method of multipliers (ADMM), the proposed distributed optimization approach scales well with increased EV charging infrastructure by balancing active and reactive power while decreasing computational burden. In our proposed hierarchical approach, each EVA schedules the active and reactive EV charging and discharging power for 1) reactive power compensation in order to minimize power factor penalty and electricity cost accrued by the EVA, 2) satisfaction of each EV’s energy demand at minimal charging cost, and 3) peak shaving and load management for the DSO. When compared with an uncoordinated charging model, the efficacy of this proposed model is successfully demonstrated through a 300% decreased peak EV load for the DSO, 28% lower electricity costs for EV users, and 98.55% smaller power factor penalty, along with 17.58% lower overall electricity costs, for EVAs. The performance of our approach is validated in a case study with 50 EVs at multiple EVAs in an IEEE 13-bus test case and compared the results with uncoordinated EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensing Service Transformer Secondary Currents using Planar Magnetic Pick-up Coils

The rapid deployment of distributed energy resources (DERs) is creating stresses on utility assets in the distribution networks. The service transformer, which is the most commonly used utility asset is often not monitored, since the cost of available sensing solutions is as high as the transformer itself. This paper presents a method to use an array of printed circuit board coils to intelligently monitor North American pole top service transformers. The approach, uses a novel, self-calibrating algorithm to infer the fixed geometry of the installation, by recording data over an extended period of time. The proposed method can enable rapid installation of a non-intrusive sensor that can be used to monitor loading levels of the distribution transformer. Furthermore, these sensors can help in planning, prognostics and advanced situational awareness for utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear structural dynamics analysis using a modified modal method

The procedure for predicting the nonlinear dynamic response of structural components subjected to a step loading is presented. The procedure is a modified modal method that involves a change of dependent variables from the unknown nodal degrees of freedom of the finite element model of the structure to a smaller set of generalized coordinates. This change of dependent variables uses a combination of the nonlinear static solution and some selected vibration mode shapes. The vibration mode shapes correspond to the eigenvectors obtained by solving a standard free vibration eigenvalue problem wherein the stiffness matrix is expanded about the nonlinear static solution. A strategy is also presented for determining which and how many vibration mode shapes to include in the transformation. The effect of inaccurate representation of the spatial distribution of the applied load on the nonlinear dynamic response is discussed for two classes of structural behavior. Application of the procedure to structures which exhibit a stiffening behavior and to those with a softening behavior is presented.

Knight, N. F., Jr.↗

Coordination of two redundant robots

A solution is presented for the optimal force distributions of two redundant coordinating robots. Two robots whose end-effectors firmly grasp a common inertial load form a closed-chain structure, and thus the robots must observe a set of constraint conditions on (1) the end-effector positions, orientations, linear and angular velocities and (2) the forces and torques inserted onto the end-effectors by the load. To achieve the maximum load capability, the optimal force distribution under the known posture is developed. If the robots are redundant, joint solutions may be obtained if some optimization criterion such as manipulability is imposed. The singularity, manipulability, and force ellipsoids are investigated in terms of the two manipulator Jacobian matrices. The manipulability is shown to correspond to the cascade structure, while the force ellipsoid corresponds to the parallel structure in terms of the manipulator Jacobian matrices.

Tao, Jian M.↗

Current Practices in Distribution Utility Resilience Planning for Winter Storms

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using Institute of Electrical and Electronics Engineers (IEEE) 1366-2022, which defines major events as an event that exceeds reasonable design and/or operational limits of the electric power system. Resilience planning is focused on major event days and reliability planning is focused on nonmajor event days. Utility resilience plans are assessed according to common resilience components identified in existing resilience frameworks. The focus of this report is on winter storms in which the primary hazards are heavy snowfall, freezing rain, ice, extreme cold, severe wind, and flooding. These hazards can also contribute to generation shortages, resulting in bulk power system impacts that have consequences for the distribution system, such as load shedding. Stand-alone reports focusing on wildfires and nonwinter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hypersonic panel flutter in a rarefied atmosphere

Panel flutter is a form of dynamic aeroelastic instability resulting from the interaction between motion of an aircraft structural panel and the aerodynamic loads exerted on that panel by air flowing past one of the faces. It differs from lifting surface flutter in the sense that it is not usually catastrophic, the panel's motion being limited by nonlinear membrane stresses produced by the transverse displacement. Above some critical airflow condition, the linear instability grows to a limit cycle . The present investigation studies panel flutter in an aerodynamic regime known as 'free molecule flow', wherein intermolecular collisions can be neglected and loads are caused by interactions between individual molecules and the bounding surface. After collision with the panel, molecules may be reflected specularly or reemitted in diffuse fashion. Two parameters characterize this process: the 'momentum accommodation coefficient', which is the fraction of the specularly reflected molecules; and the ratio between the panel temperature and that of the free airstream. This model is relevant to the case of hypersonic flight vehicles traveling at very high altitudes and especially for panels oriented parallel to the airstream or in the vehicle's lee. Under these conditions the aerodynamic shear stress turns out to be considerably larger than the surface pressures, and shear effects must be included in the model. This is accomplished by means of distributed longitudinal and bending loads. The former can cause the panel to buckle. In the example of a simply-supported panel, it turns out that the second mode of free vibration tends to dominate the flutter solution, which is carried out by a Galerkin analysis. Several parametric studies are presented. They include the effects of (1) temperature ratio; (2) momentum accommodation coefficient; (3) spring parameters, which are associated with how the panel is connected to adjacent structures; (4) a parameter which relates compressive end load to its value which would cause classical column buckling; (5) a parameter proportional to the pressure differential between the front and back faces; and (6) initial curvature. The research is completed by an investigation into the possibility of accounting for molecular collisions, which proves to be infeasible given the speeds of current mainframe supercomputers.

Resende, Hugo B.↗

Test and evaluation of load converter topologies used in the Space Station Freedom Power Management and distribution DC test bed

Power components hardware in support of the Space Station Freedom dc Electrical Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switchmode converter, and a switching full-bridge forward converter. The topology, operation principles, and tests results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.

Lebron, Ramon C.↗

Test and evaluation of load converter topologies used in the Space Station Freedom power management and distribution dc test bed

Power components hardware in support of the Space Station freedom dc Electric Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switch-mode converter, and a switching full-bridge forward converter. The topology, operation principles, and test results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.

Lebron, Ramon C.↗

Effect of air path heat losses at different locations in vapor compression-based clothes dryer: Quasi-steady modeling and design implications

Clothes drying is among the most power-intensive household end uses, and vapor compression-based clothes dryers offer substantial energy cost savings compared with conventional electric heater dryers. However, parasitic heat losses along the air path, that is, heat loss at the upstream of the drum, inside the drum, and at downstream of the drum, remain rarely quantified, but can strongly affect overall performance according to experiments. Here, this study enhances a vapor compression simulation model by integrating a validated drum model using a dimensionless heat-and-mass-transfer effectiveness correlation derived from 63 drying tests in the literature to form a quasi-steady dryer simulation model. The model is validated against laboratory measurements of a baseline dryer. The impact of heat losses is simulated at three locations and explored through 16 heat loss cases spanning two loads (2 and 5 kg), two airflow rates, and multiple loss distributions. For a 5 kg wet load, eliminating pre-drum and in-drum losses reduces total energy use by up to 34–35% and shortens drying time by 27–38% compared with the baseline. At a 2 kg wet load, introducing post-drum heat loss lowers energy costs by up to 23% and reduces operation time by up to 57% compared with the baseline. The results demonstrate that the impact of heat loss is location dependent. Vapor compression dryers should minimize pre-drum and in-drum losses while potentially exploiting post-drum heat dissipation to enhance the drying rate and energy cost savings.

Dryer↗

Hierarchical Control of Distributed Battery Energy Storage Systems in a DC Microgrid

Contents - NASA Future Power Systems - DC Microgrid with Distributed Battery Energy Storage - A simplified gateway power system - Droop Control (Primary Control) - Distributed battery units, droop control, and load sharing characteristics - Simulation results - Three-Level Hierarchical Control of Distributed Battery Units During Eclipse - Secondary Control - Objective and definition of unit control error - Implementation of secondary control - Simulation results - Tertiary Control - Schedule BU current sharing with the objective of equal SoC - Simulation results•Conclusions

Jing Zhang↗