Investigating On-Orbit Attitude Determination Anomalies for the Solar Dynamics Observatory Mission

The Solar Dynamics Observatory (SDO) was launched on February 11, 2010 from Kennedy Space Center on an Atlas V launch vehicle into a geosynchronous transfer orbit. SDO carries a suite of three scientific instruments, whose observations are intended to promote a more complete understanding of the Sun and its effects on the Earth's environment. After a successful launch, separation, and initial Sun acquisition, the launch and flight operations teams dove into a commissioning campaign that included, among other things, checkout and calibration of the fine attitude sensors and checkout of the Kalman filter (KF) and the spacecraft s inertial pointing and science control modes. In addition, initial calibration of the science instruments was also accomplished. During that process of KF and controller checkout, several interesting observations were noticed and investigated. The SDO fine attitude sensors consist of one Adcole Digital Sun Sensor (DSS), two Galileo Avionica (GA) quaternion-output Star Trackers (STs), and three Kearfott Two-Axis Rate Assemblies (hereafter called inertial reference units, or IRUs). Initial checkout of the fine attitude sensors indicated that all sensors appeared to be functioning properly. Initial calibration maneuvers were planned and executed to update scale factors, drift rate biases, and alignments of the IRUs. After updating the IRU parameters, the KF was initialized and quickly reached convergence. Over the next few hours, it became apparent that there was an oscillation in the sensor residuals and the KF estimation of the IRU bias. A concentrated investigation ensued to determine the cause of the oscillations, their effect on mission requirements, and how to mitigate them. The ensuing analysis determined that the oscillations seen were, in fact, due to an oscillation in the IRU biases. The low frequencies of the oscillations passed through the KF, were well within the controller bandwidth, and therefore the spacecraft was actually following the oscillating biases, resulting in movement of the spacecraft on the order of plus or minus 20 arcsec. Though this level of error met the ACS attitude knowledge requirement of [35, 70, 70] arcsec, 3 sigma, the desire of the ACS and instrument teams was to remove as much of the oscillation as possible. The Kearfott IRUs have an internal temperature controller, designed to maintain the IRU temperature at a constant temperature of approximately 70 C, thus minimizing the change in the bias drift and scale factors of the mechanical gyros. During ground testing of the observatory, it was discovered that the 83-Hz control cycle of the IRU heaters put a tremendous amount of stress on the spacecraft battery. Analysis by the power systems team indicated that the constant charge/discharge on the battery due to the IRU thermal control cycle could potentially limit the life of the battery. After much analysis, the decision was made not to run the internal IRU heaters. Analysis of on orbit data revealed that the oscillations in the IRU bias had a connection to the temperature of the IRU; changes in IRU temperature resulted in changes in the amplitude and period of the IRU biases. Several mitigating solutions were investigated, the result of which was to tune the KF with larger IRU noise assumptions which allows the KF to follow and correct for the time-varying IRU biases.

Vess, Melissa F.↗

A Preliminary Benefit-Cost Study of a Sandia Wind Farm

In response to federal mandates and incentives for renewable energy, Sandia National Laboratories conducted a feasibility study of installing an on-site wind farm on Sandia National Laboratories and Kirtland Air Force Base property. This report describes this preliminary analysis of the costs and benefits of installing and operating a 15-turbine, 30-MW-capacity wind farm that delivers an estimated 16 percent of 2010 onsite demand. The report first describes market and non-market economic costs and benefits associated with operating a wind farm, and then uses a standard life-cycle costing and benefit-cost framework to estimate the costs and benefits of a wind farm. Based on these 'best-estimates' of costs and benefits and on factor, uncertainty and sensitivity analysis, the analysis results suggest that the benefits of a Sandia wind farm are greater than its costs. The analysis techniques used herein are applicable to the economic assessment of most if not all forms of renewable energy.

17 WIND ENERGY↗

Oklahoma Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the 2009 IRC

The 2012 International Energy Conservation Code (IECC) yields positive benefits for Oklahoma homeowners. Moving to the 2012 IECC from Chapter 11 of the 2009 International Residential Code (IRC) is cost effective over a 30-year life cycle. On average, Oklahoma homeowners will save $\$$5,786 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2012 IECC. Average annual energy savings are $\$$408 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Texas Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the 2009 IECC

The 2012 International Energy Conservation Code (IECC) yields positive benefits for Texas homeowners. Moving to the 2012 IECC from the 2009 IECC is cost effective over a 30-year life cycle. On average, Texas homeowners will save $\$$3,456 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for the 2012 IECC. Average annual energy savings are $\$$259 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Virginia Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the 2009 Virginia Construction Code

The 2012 International Energy Conservation Code (IECC) yields positive benefits for Virginia homeowners. Moving to the 2012 IECC from the current Virginia Construction Code is cost effective over a 30-year life cycle. On average, Virginia homeowners will save $\$$5,836 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2012 IECC. Average annual energy savings are $\$$388 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Life Cycle Costing in Radioactive Waste Packaging: Reducing Costs Whilst Accelerating Clean-Up - 16131

In recognition of the high up-front costs and potentially long timescales to implement the more traditional methods of encapsulating wastes, in the UK alternative approaches to help accelerate hazard reduction and reduce such costs are being deployed. When considering such the cost of alternative approaches to waste packaging strategies, it is important that the complete waste life cycle is taken into account. This paper will demonstrate that when evaluating waste packaging options, whilst individual elements (e.g. container costs) within an overall waste management programme may appear to offer a cost benefit by comparison with alternatives, the programme as a whole may not necessarily be the most cost effective solution when life cycle costs are taken into account, or when other technical issues are considered. To illustrate this point this paper will present a view of the application of LCC, utilising a number of waste packaging scenarios, to promote discussion and consideration of the benefits of undertaking a holistic assessment of the investment decision as part of an overall waste management strategy. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building a Prospective LCA Framework to Analyze Emerging Technologies in a Dynamic System Context

NREL's Lifecycle Analysis Integration into Opensource Numerical models (LiAISON) framework computes temporally explicit life cycle impacts and resource uses for specific technologies (foreground) in a dynamic system context (background). LiAISON computes results for a series of environmental mid-points enabling an analysis of prospective tradeoffs of emerging technologies toward 2100. This prospective feature is of critical importance when analyzing present-day emerging technologies whose large-scale impacts during deployment phases will occur in different, future system contexts. LiAISON systematically accounts for dynamic system changes by applying an integrated background of the future energy-economy-land-climate system, generated by exogenous integrated assessment models (IAMs). Using IAM scenarios, LiAISON generates a time-series of life cycle inventory (LCI) databases, which are then used to calculate the impacts per functional unit per time step. This expands current practice of using static, future system assumptions, e.g., a specific grid-mix each year. Further, IAM scenarios are provided in a standardized format of shared-socioeconomic pathways (SSP) and representative concentration pathways (RCP) combinations. These are coherent, regularly, published, and peer-reviewed scenario combinations that establish a reproducible and standardized societal and climate mitigation futures context. They are comparable across IAMs and expand the system boundary of the traditional LCA by including dimensions such as societal and behavioral changes. We apply the framework to assess two emerging Power-to-Hydrogen processes, high temperature electrolysis using solid oxide fuel cell (HT-SOE) and polymer electrolyte membrane electrolysis (PEME). We compare the technologies to a baseline Hydrogen production process via steam methane reforming. Despite the decarbonized electricity systems' beneficial effects on the PtH2 processes' carbon intensities, we find environmental tradeoffs, which require technology improvements via learning-by-doing to be alleviated. Future work via ongoing collaborations will focus on linking the framework to other energy-economy-land-climate models and open-source life cycle inventory databases.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Probabilistic Analysis of Aircraft Gas Turbine Disk Life and Reliability

Two series of low cycle fatigue (LCF) test data for two groups of different aircraft gas turbine engine compressor disk geometries were reanalyzed and compared using Weibull statistics. Both groups of disks were manufactured from titanium (Ti-6Al-4V) alloy. A NASA Glenn Research Center developed probabilistic computer code Probable Cause was used to predict disk life and reliability. A material-life factor A was determined for titanium (Ti-6Al-4V) alloy based upon fatigue disk data and successfully applied to predict the life of the disks as a function of speed. A comparison was made with the currently used life prediction method based upon crack growth rate. Applying an endurance limit to the computer code did not significantly affect the predicted lives under engine operating conditions. Failure location prediction correlates with those experimentally observed in the LCF tests. A reasonable correlation was obtained between the predicted disk lives using the Probable Cause code and a modified crack growth method for life prediction. Both methods slightly overpredict life for one disk group and significantly under predict it for the other.

Melis, Matthew E.↗

Louisiana Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Louisiana homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Louisiana homeowners will save $\$$1,663 over 30 years under the 2009 IECC, with savings still higher at $\$$4,107 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for both the 2009 and 2012 IECC. Average annual energy savings are $\$$149 for the 2009 IECC and $\$$358 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mississippi Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Mississippi homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Mississippi homeowners will save $\$$2,022 over 30 years under the 2009 IECC, with savings still higher at $\$$5,400 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for both the 2009 and 2012 IECC. Average annual energy savings are $\$$164 for the 2009 IECC and $\$$422 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Missouri Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Missouri homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Missouri homeowners will save $\$$2,229 over 30 years under the 2009 IECC, with savings still higher at $\$$7,826 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for both the 2009 and 2012 IECC. Average annual energy savings are $\$$143 for the 2009 IECC and $\$$507 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tennessee Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Tennessee homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Tennessee homeowners will save $\$$1,809 over 30 years under the 2009 IECC, with savings still higher at $\$$6,102 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for both the 2009 and 2012 IECC. Average annual energy savings are $\$$123 for the 2009 IECC and $\$$415 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Wisconsin Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the Wisconsin Uniform Dwelling Code

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Wisconsin homeowners. Moving to either the 2009 or 2012 IECC from the current Wisconsin state code is cost effective over a 30-year life cycle. On average, Wisconsin homeowners will save $\$$2,484 over 30 years under the 2009 IECC, with savings still higher at $\$$10,733 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for both the 2009 and 2012 IECC. Average annual energy savings are $\$$149 for the 2009 IECC and $\$$672 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

West Virginia Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for West Virginia homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, West Virginia homeowners will save $\$$1,996 over 30 years under the 2009 IECC, with savings still higher at $\$$7,301 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for both the 2009 and 2012 IECC. Average annual energy savings are $\$$135 for the 2009 IECC and $\$$480 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Arkansas Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Arkansas homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Arkansas homeowners will save $\$$1,948 over 30 years under the 2009 IECC, with savings still higher at $\$$6,679 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for the 2009 and 1 year for the 2012 IECC. Average annual energy savings are $\$$147 for the 2009 IECC and $\$466 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy valuation methods for biofuels in South Florida: Introduction to life cycle assessment and emergy approaches

Here, recent changes in the United States requiring the use of ethanol in gasoline for most vehicular transportation have created discussion about important issues, such as shifting the use of certain plants from food production to energy supply, related federal subsidies, effects on soil, water and atmosphere resources, tradeoffs between food production and energy production, speculation about biofuels as a possible means for energy security, potential reduction of greenhouse gas (GHG) emissions or development and expansion of biofuels industry. A sustainable approach to biofuel production requires understanding inputs (i.e., energy required to carry out a process, both natural and anthropogenic) and outputs (i.e., energy produced by that process) and cover the entire process, as well as environmental considerations that can be overlooked in a more traditional approach. This publication gives an overview of two methods for evaluating energy transformations in biofuels production: (1) Life Cycle Assessment (LCA) and (2) Emergy Assessment (EA). The LCA approach involves measurements affecting greenhouse gases (GHG), which can be linked to the energy considerations used in the EA. Although these two methods have their basis in energy or GHG evaluations, their approaches can lead to a reliable judgment regarding a biofuel process. Using these two methods can ensure that the energy components are well understood and can help to evaluate the economic environmental component of a biofuel process. In turn, using these two evaluative tools will allow for decisions about biofuel processes that favor sustainability

09 BIOMASS FUELS↗

Development of the Well-to-Wake Life Cycle Assessment Model for Marine Fuels in R&D GREET 2025

The Marine analysis capabilities in the 2025 Research and Development Greenhouse gases, Regulated Emissions, and Energy use in Technologies (R&D GREET) have been updated to incorporate the latest findings from the Fourth International Maritime Organization (IMO) GHG Study.1 To support these updates and enhance user flexibility, the former single marine module used in previous R&D GREET versions has been split into two workbook tabs: The Marine_Fuel tab, which covers the fuel-cycle, and the Marine_Trip tab, which covers the trip-cycle. In the Marine_Fuel tab, fuel cycle results for 39 marine fuels are available—assuming a slow speed diesel engine—and can be seen in Appendix A. However, there are options for changing feedstocks for multiple fuels, ability to view results with or without pilot fuels for fuels such as methanol and ammonia, and carbon capture options. All these combinations make the number of total possible pathways over one hundred. For each pathway, life cycle emission results are divided into feedstock, conversion, and combustion categories, along with pilot fuel supply chain emissions for fuels used in dual fuel engines. In the newly created Marine_Trip tab, users can view the life cycle emissions of using these fuels from a trip perspective. Compared to R&D GREET 2024, 16 new types of vessels are added in R&D GREET 2025. Examples of results assuming the default size for each vessel type are available in Appendix A. Additional information categories on vessels are included such as vessel size, main propulsion type, engine power rating, combustion cycle, etc. based on the Fourth IMO GHG Study. Operational mode of the trip, fuel consumption, and load calculation were updated based on the report. The fuel consumption calculation also incorporates low-load adjustment, speed–power correction, weather correction, and fouling correction factors. Furthermore, fuel consumption in boilers or steam turbines is also added for the first time, besides fuel use in main propulsion engines and auxiliary engines. This effort makes the R&D GREET Marine capabilities more robust than before. Users will be able to estimate fuel consumption more accurately for more diverse choices of vessel categories, vessel sizes, and energy converters.

09 BIOMASS FUELS↗