Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Interns”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

International code of nomenclature of prokaryotes

Here, this volume contains the edition of the International Code of Nomenclature of Prokaryotes that was presented in draft form and available for comment at the Plenary Session of the Fourteenth International Congress of Bacteriology and Applied Microbiology (BAM), Montréal, 2014, together with updated lists of conserved and rejected bacterial names and of Opinions issued by the Judicial Commission. As in the past it brings together those changes accepted, published and documented by the ICSP and the Judicial Commission since the last revision was published. Several new appendices have been added to this edition. Appendix 11 addresses the appropriate application of the Candidatus concept, Appendix 12 contains the history of the van Niel Prize, and Appendix 13 contains the summaries of Congresses.

59 BASIC BIOLOGICAL SCIENCES↗

CMB internal delensing with general optimal estimator for higher-order correlations

We present here a new method for delensing B modes of the cosmic microwave background (CMB) using a lensing potential reconstructed from the same realization of the CMB polarization (CMB internal delensing). The B -mode delensing is required to improve sensitivity to primary B modes generated by, e.g., the inflationary gravitational waves, axionlike particles, modified gravity, primordial magnetic fields, and topological defects such as cosmic strings. However, the CMB internal delensing suffers from substantial biases due to correlations between observed CMB maps to be delensed and that used for reconstructing a lensing potential. Since the bias depends on realizations, we construct a realization-dependent (RD) estimator for correcting these biases by deriving a general optimal estimator for higher-order correlations. The RD method is less sensitive to simulation uncertainties. Compared to the previous ℓ -splitting method, we find that the RD method corrects the biases without substantial degradation of the delensing efficiency.

79 ASTRONOMY AND ASTROPHYSICS↗

Internal energy balance and aerodynamic heating predictions for hypersonic turbulent boundary layers

The elemental equation governing heat transfer in aerodynamic flows is the internal energy equation. For a boundary layer flow, a double integration of the Reynolds-averaged form of this equation provides an expression of the wall heat flux in terms of the integrated effects, over the boundary layer, of various physical processes: turbulent dissipation, mean dissipation, turbulent heat flux, etc. Recently available direct numerical simulation data for a Mach 11 cold-wall turbulent boundary layer allows a comparison of the exact contributions of these terms in the energy equation to the wall heat flux with their counterparts modeled in the Reynolds-averaged Navier-Stokes (RANS) framework. Various approximations involved in RANS, both closure models as well as approximations involved in adapting incompressible RANS models to a compressible form, are assessed through examination of the internal energy balance. There are a number of potentially problematic assumptions and terms identified through this analysis. Here, the effect of compressibility corrections of the dilatational dissipation type is explored, as is the role of the modeled turbulent dissipation, in the context of wall heat flux predictions. The results indicate several potential avenues for RANS model improvement for hypersonic cold-wall boundary-layer flows.

42 ENGINEERING↗

Internal Delensing of Cosmic Microwave Background Polarization B -Modes with the POLARBEAR Experiment

Using only cosmic microwave background polarization data from the polarbear experiment, we measure B-mode polarization delensing on subdegree scales at more than 5σ significance. We achieve a 14% B-mode power variance reduction, the highest to date for internal delensing, and improve this result to 22% by applying for the first time an iterative maximum a posteriori delensing method. Our analysis demonstrates the capability of internal delensing as a means of improving constraints on inflationary models, paving the way for the optimal analysis of next-generation primordial B-mode experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Evolution of texture and internal stresses within polycrystalline rock salt using in situ 3D synchrotron computed tomography and 3D X-ray diffraction

Over time rock salt caverns have been extensively used as reliable repositories for hazardous waste such as nuclear waste, oil or compressed gases. Undisturbed rock salt deposits in nature are usually impermeable and have very low porosity. However, rock salt formations under excavation stresses can develop crack networks, which increase their porosities; and in the case of a connected crack network within the media, rock salt may become permeable. Although the relationship between the permeability of rock salt and the applied stresses has been reported in the literature, a microscopic study that investigates the properties influencing this relationship, such as the evolution of texture and internal stresses, has yet to be conducted. This study employs in situ 3D synchrotron micro-computed tomography and 3D X-ray diffraction (3DXRD) on two small-scale polycrystalline rock salt specimens to investigate the evolution of the texture and internal stresses within the specimens. The 3DXRD technique measures the 3D crystal structure and lattice strains within rock salt grains. The specimens were prepared under 1D compression conditions and have shown an initial {111} preferred texture, a dominant {110}$\langle1\bar{1}0\rangle$ slip system and no fully connected crack network. The {111} preferred texture under the unconfined compression experiment became stronger, while the {111}$\langle1\bar{1}0\rangle$ slip system became more prominent. The specimens did not have a fully connected crack network until applied axial stresses reached about 30 MPa, at a point where the impermeability of the material becomes compromised due to the development of multiple major cracks.

36 MATERIALS SCIENCE↗

Coordination of International Standards with Implementation of the IECRE Conformity Assessment System to Provide Multiple Certification Offerings for PV Power Plants

To help address the industry's needs for assuring the value and reducing the risk of investments in PV power plants; the International Electrotechnical Commission (IEC) has established a new conformity assessment system for renewable energy (IECRE). There are presently important efforts underway to define the requirements for various types of PV system certificates, and publication of the international standards upon which these certifications will be based. This paper presents a detailed analysis of the interrelationship of these activities and the timing for initiation of IECRE PV system certifications.

14 SOLAR ENERGY↗

Computational Study of Additively Manufactured Internally Cooled Airfoils for Industrial Gas Turbine Applications

Internal cooling features such as pin-fins, impingement jets, and rib-turbulators are necessary to keep turbine components cool, but if sufficiently advanced can potentially also eliminate the need for film cooling on turbine blades particularly in industrial gas turbines where temperatures are not extreme. Furthermore, by leveraging additive manufacturing, other advanced designs such as lattice and incremental impingement configurations are possible and have recently been experimentally tested. While the performance of such configurations has been quantified through means of overall cooling effectiveness, it is not as clear why certain designs were better than others, or what the mechanisms were behind the observed external cooling patterns. The purpose of this study was to computationally analyze different advanced turbine blade internal cooling designs previously tested by the National Energy Technology Laboratory.

CFD↗

Effect of Internal Pressurization on the Creep-Fatigue Performance of Alloy 617 Based on Simplified Model Test Method

The Simplified Model Test (SMT) is an alternative approach to determine cyclic life at elevated temperature and avoids parsing the damage into creep and fatigue components. The original SMT concept [1] considered that the effects of sustained primary stress loading could be safely neglected because the allowable local stress and strain levels were much higher than the allowable sustained primary stress levels. This key assumption is critically evaluated on Alloy 617 using internal pressurized cylindrical SMT specimens at 950 °C. The impact of combined internal pressurization and displacement-controlled creep-fatigue loading on the SMT cycle life is demonstrated at different strain ranges. The effect of primary load on the SMT design method is discussed.

Wang, Yanli↗

Post Irradiation Examination of Pressurized Water Reactor Stainless Steel Internal Components

Internal structural components of pressurized water reactors (PWR), such as baffle former bolts, are subjected to significant neutron irradiation and mechanical stresses at elevated temperatures during plant operation. Over the long operation of the power plant, these conditions lead to potential degradation and reduced load-carrying capacity of these bolts. To understand property degradation more fully, to confirm the results of experimental irradiation programs, and to predict operational lifetime performance of structural materials in internal components, post irradiation examination of harvested materials from operating nuclear reactors is required. In this work, two high fluence 316 stainless steel baffle former bolts were retrieved from a commercial Westinghouse two-loop downflow type PWR and then sectioned for analysis via mechanical testing and microstructural characterization. The irradiation damage fluctuated along the bolt length with damage levels from 15 to 41 displacements per atom with the bolt head receiving approximately twice the neutron damage levels as that of the bolt thread section. Mechanical testing evaluations showed extensive irradiation hardening and a sharp decrease in fracture toughness in all parts of the bolt, though with limited variation along the bolt length. Microstructural characterization using analytical scanning transmission electron microscopy and atom probe tomography showed significant radiation induced precipitation, segregation, and dislocation loop and cavity formation. However, unlike the mechanical behavior, there was considerable variation along the bolt length but opposite of what may be expected, with more precipitation and cavity formation in the bolt thread where the neutron radiation dose is less than in the bolt head where the neutron radiation dose is higher. The cause of this variation is likely due to gradients in temperature, neutron energy spectra, and gamma irradiation.

Lach, Tim↗

Monitoring internal organ motion with continuous wave radar in CT

Purpose: To avoid motion artifacts in medical imaging or to minimize the exposure of healthy tissues in radiation therapy, medical devices are often synchronized with the patient's respiratory motion. Today's respiratory motion monitors require additional effort to prepare the patients, e.g., mounting a motion belt or placing an optical reflector on the patient's breast. Furthermore, they are not able to measure internal organ motion without implanting markers. An interesting alternative to assess the patient's organ motion is continuous wave radar. The aim of this work is to design, implement, and evaluate such a radar system focusing on application in CT.Methods: The authors designed a radar system operating in the 860 MHz band to monitor the patient motion. In the intended application of the radar system, the antennas are located close to the patient's body inside the table of a CT system. One receive and four transmitting antennas are used to avoid the requirement of exact patient positioning. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example at the borderline between muscle and adipose tissue, or at the boundaries of organs. At present, the authors focus on the detection of respiratory motion. The radar system consists of the hardware mentioned above as well as of dedicated signal processing software to extract the desired information from the radar signal. The system was evaluated using simulations and measurements. To simulate the radar system, a simulation model based on radar and wave field equations was designed and 4D respiratory-gated CT data sets were used as input. The simulated radar signals and the measured data were processed in the same way. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the respiratory motion signal was recorded using a breast belt simultaneously with the radar measurements.Results: Concerning the measurements of the test persons, there is a very good correlation (ρ= 0.917) between the respiratory motion phases received by the radar system and the external motion monitor. Our concept of using an array of transmitting antennas turned out to be widely insensitive to the positioning of the test persons. A time shift between the respiratory motion curves recorded with the radar system and the motion curves from the external respiratory monitor was observed which indicates a slight difference between internal organ motion and motion detected by the external respiratory monitor. The simulations were in good accordance with the measurements.Conclusions: A continuous wave radar operating in the near field of the antennas can be used to determine the respiratory motion of humans accurately. In contrast to trigger systems used today, the radar system is able to measure motion inside the body. If such a monitor was routinely available in clinical CT, it would be possible optimizing the scan start with respect to the respiratory state of the patient. Breathing commands would potentially widely be avoided, and as far as uncooperative patients or children are concerned, less sedation might be necessary. Further applications of the radar system could be in radiation therapy or interventional imaging for instance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-78: Internal Target Volume Delineation for Lung Tumors in Patients Treated with Robotic Radiosurgery

Purpose: To compare different approaches for Internal Target Volume (ITV) delineation for patients treated with fiducial-free robotic radiosurgery for primary and metastatic lung tumors. Methods: Ten patients undergoing Lung-Optimized Treatment (LOT) for robotic radiosurgery were imaged with inhale and exhale breath-hold CT scans and 8-phase 4DCT scan. We evaluated the differences in internal target volume (ITV) delineated using three approaches: 1) maximum intensity projection (MIP) images reconstructed from 4DCT scan (ITV-MIP); 2) linear interpolation of Gross Tumor Volumes (GTV) segmented on inhale and exhale breath-hold scans (ITV-BH); 3) linear interpolation of GTV segmented on inhale and exhale phases of 4DCT scan (ITV-2Phase). All contours were independently generated by the same radiation oncologist using lung window settings. Patients had ITV-MIP volumes ranging from 1.5 to 146.9 cc (mean 36.8 cc) located in various parts of the lung. Volume overlap and matching index (MI) were calculated and compared. The MI between two volumes was defined as the ratio of their intersection to their union. MI of 1 indicates the volumes are identical; MI of 0 indicates that there is no overlap. Results: The three approaches generated very different results. The average (SD) MI for ITV-MIP and ITV-BH was 0.52 (0.24); for ITV-MIP and ITV-2Phase it was 0.69 (0.13); and for ITV-BH and ITV-2Phase was 0.57 (0.21), (ANOVA, p=0.16). Relative to the ITV-MIP, the percentage of volume overlap was 72% (26%) and 90% (7%) for ITV-BH and ITV-2Phase, respectively (t-test, p=0.05). Conclusion: Differences between ITV-BH and ITV-MIP are due to inconsistent lung filling at breath-hold and nonlinear tumor motion. Therefore, methods to check breath-hold scanning against regular patient breathing patterns should be developed. Whenever possible, ITV-BH generated by the LOT workflow should be verified by 4DCT data.

60 APPLIED LIFE SCIENCES↗

SU-E-J-79: Internal Tumor Volume Motion and Volume Size Assessment Using 4D CT Lung Data

Purpose: To assess internal tumor volume change through breathing cycle and associated tumor motion using the 4DCT data. Methods: Respiration induced volume change through breathing cycle and associated motion was analyzed for nine patients that were scanned during the different respiratory phases. The examined datasets were the maximum and average intensity projections (MIP and AIP) and the 10 phases of the respiratory cycle. The internal target volume (ITV) was delineated on each of the phases and the planning target volume (PTV) was then created by adding setup margins to the ITV. Tumor motion through the phases was assessed using the acquired 4DCT dataset, which was then used to determine if the margins used for the ITV creation successfully encompassed the tumor in three dimensions. Results: Results showed that GTV motion along the superior inferior axes was the largest in all the cases independent of the tumor location and/or size or the use of abdomen compression. The extent of the tumor motion was found to be connected with the size of the GTV. The smallest GTVs exhibited largest motion vector independent of the tumor location. The motion vector size varied through the phases depending on the tumor size and location and it was smallest for phases 20 and 30. The smaller the volume of the delineated GTV, the greater its volume difference through the different respiratory phases was. The average GTV volume change was largest for the phases 60 and 70. Conclusion: Even if GTV is delineated using both AIP and MIP datasets, its motion extent will exceed the used margins especially for the very small GTV volumes. When the GTV size is less than 10 cc it is recommended to use fusion of the GTVs through all the phases to create the planning ITV.

60 APPLIED LIFE SCIENCES↗

SU-E-J-192: Verification of 4D-MRI Internal Target Volume Using Cine MRI

Purpose: To investigate the accuracy of 4D-MRI in determining the Internal Target Volume (ITV) used in radiation oncology treatment planning of liver cancers. Cine MRI is used as the standard baseline in establishing the feasibility and accuracy of 4D-MRI tumor motion within the liver. Methods: IRB approval was obtained for this retrospective study. Analysis was performed on MR images from four patients receiving external beam radiation therapy for liver cancer at our institution. Eligible patients received both Cine and 4D-MRI scans before treatment. Cine images were acquired sagittally in real time at a slice bisecting the tumor, while 4D images were acquired volumetrically. Cine MR DICOM headers were manipulated such that each respiratory frame was assigned a unique slice location. This approach permitted the treatment planning system (Eclipse, Varian Medical Systems) to recognize a complete respiratory cycle as a “volume”, where the gross tumor was contoured temporally. Software was developed to calculate the union of all frame contours in the structure set, resulting in the corresponding plane of the ITV projecting through the middle of the tumor, defined as the Internal Target Area (ITA). This was repeated for 4D-MRI, at the corresponding slice location, allowing a direct comparison of ITAs obtained from each modality. Results: Four patients have been analyzed. ITAs contoured from 4D-MRI correlate with contours from Cine MRI. The mean error of 4D values relative to Cine values is 7.67 +/− 2.55 %. No single ITA contoured from 4D-MRI demonstrated more than 10.5 % error compared to its Cine MRI counterpart. Conclusion: Motion management is a significant aspect of treatment planning within dynamic environments such as the liver, where diaphragmatic and cardiac activity influence plan accuracy. This small pilot study suggests that 4D-MRI based ITA measurements agree with Cine MRI based measurements, an important step towards clinical implementation. NIH 1R21CA165384-01A1.

60 APPLIED LIFE SCIENCES↗

Internal respiratory surrogate in multislice 4D CT using a combination of Fourier transform and anatomical features

Purpose: The purpose of this study was to develop a novel algorithm to create a robust internal respiratory signal (IRS) for retrospective sorting of four-dimensional (4D) computed tomography (CT) images. Methods: The proposed algorithm combines information from the Fourier transform of the CT images and from internal anatomical features to form the IRS. The algorithm first extracts potential respiratory signals from low-frequency components in the Fourier space and selected anatomical features in the image space. A clustering algorithm then constructs groups of potential respiratory signals with similar temporal oscillation patterns. The clustered group with the largest number of similar signals is chosen to form the final IRS. To evaluate the performance of the proposed algorithm, the IRS was computed and compared with the external respiratory signal from the real-time position management (RPM) system on 80 patients. Results: In 72 (90%) of the 4D CT data sets tested, the IRS computed by the authors’ proposed algorithm matched with the RPM signal based on their normalized cross correlation. For these data sets with matching respiratory signals, the average difference between the end inspiration times (Δt{sub ins}) in the IRS and RPM signal was 0.11 s, and only 2.1% of Δt{sub ins} were more than 0.5 s apart. In the eight (10%) 4D CT data sets in which the IRS and the RPM signal did not match, the average Δt{sub ins} was 0.73 s in the nonmatching couch positions, and 35.4% of them had a Δt{sub ins} greater than 0.5 s. At couch positions in which IRS did not match the RPM signal, a correlation-based metric indicated poorer matching of neighboring couch positions in the RPM-sorted images. This implied that, when IRS did not match the RPM signal, the images sorted using the IRS showed fewer artifacts than the clinical images sorted using the RPM signal. Conclusions: The authors’ proposed algorithm can generate robust IRSs that can be used for retrospective sorting of 4D CT data. The algorithm is completely automatic and requires very little processing time. The algorithm is cost efficient and can be easily adopted for everyday clinical use.

60 APPLIED LIFE SCIENCES↗

SU-E-J-123: Assessing Segmentation Accuracy of Internal Volumes and Sub-Volumes in 4D PET/CT of Lung Tumors Using a Novel 3D Printed Phantom

Purpose: To assess the accuracy of internal target volume (ITV) segmentation of lung tumors for treatment planning of simultaneous integrated boost (SIB) radiotherapy as seen in 4D PET/CT images, using a novel 3D-printed phantom. Methods: The insert mimics high PET tracer uptake in the core and 50% uptake in the periphery, by using a porous design at the periphery. A lung phantom with the insert was placed on a programmable moving platform. Seven breathing waveforms of ideal and patient-specific respiratory motion patterns were fed to the platform, and 4D PET/CT scans were acquired of each of them. CT images were binned into 10 phases, and PET images were binned into 5 phases following the clinical protocol. Two scenarios were investigated for segmentation: a gate 30–70 window, and no gating. The radiation oncologist contoured the outer ITV of the porous insert with on CT images, while the internal void volume with 100% uptake was contoured on PET images for being indistinguishable from the outer volume in CT images. Segmented ITVs were compared to the expected volumes based on known target size and motion. Results: 3 ideal breathing patterns, 2 regular-breathing patient waveforms, and 2 irregular-breathing patient waveforms were used for this study. 18F-FDG was used as the PET tracer. The segmented ITVs from CT closely matched the expected motion for both no gating and gate 30–70 window, with disagreement of contoured ITV with respect to the expected volume not exceeding 13%. PET contours were seen to overestimate volumes in all the cases, up to more than 40%. Conclusion: 4DPET images of a novel 3D printed phantom designed to mimic different uptake values were obtained. 4DPET contours overestimated ITV volumes in all cases, while 4DCT contours matched expected ITV volume values. Investigation of the cause and effects of the discrepancies is undergoing.

60 APPLIED LIFE SCIENCES↗

SU-F-J-137: Intrafractional Change of the Relationship Between Internal Fiducials and External Breathing Signal in Pancreatic Cancer Stereotactic Body Radiation Therapy

Purpose: The use of respiratory gating for management of breathing motion during stereotactic body radiation therapy (SBRT) relies on a consistent relationship between the breathing signal and the actual position of the internal target. This relationship was investigated in patients treated for pancreatic cancer. Methods: Four patients with pancreatic cancer undergoing SBRT that had implanted fiducials in the tumor were included in this study. Treatment plans were generated based on the exhale phases (30–70%) from the pre-treatment 4DCT. The margin between the internal target volume (ITV) and the planning target volume was three mm. After patient setup using cone-beam CT, simultaneous fluoroscopic imaging and breathing motion monitoring were used during at least three breathing cycles to verify the fiducial position and to optimize the gating window. After treatment, fluoroscopic images were acquired for verification purposes and exported for retrospective analyses. Fiducial positions were determined using a template-matching algorithm. For each dataset, we established a linear relationship between the fiducial position and the anterior-posterior (AP) breathing signal. The relationships before and after treatment were compared and the dose distribution impact evaluated. Results: Seven pre- and post-treatment fluoroscopic pairs were available for fiducial position analyses in the superior-inferior (SI) and left-right (LR) directions, and five in the AP direction. Time between image acquisitions was typically six to eight minutes. An average absolute change of 1.2±0.7 mm (range: 0.1–1.7) of the SI fiducial position relative to the external signal was found. Corresponding numbers for the LR and AP fiducial positions were 0.9±1.0 mm (range: 0.2–3.0) and 0.5±0.4 mm (range: 0.2–1.2), respectively. The dose distribution impact was small in both the ITV and organs-at-risk. Conclusion: The relationship change between fiducial position and external breathing signal has been observed to be about 1 mm in four pancreas SBRT patients, leading to small dose distribution impact. Pettersson and Cervino are funded by a Varian Medical Systems grant.

60 APPLIED LIFE SCIENCES↗

Methods for organizing the interaction of circulating particle beams with internal targets in nuclear physics experiments at synchrotrons and storage rings

The first methods for using internal targets and their further development for organization of nuclear physics experiments at synchrotrons and storage rings are reviewed. With these methods, new results are obtained and discoveries are made in physics of interactions of elementary particles and nuclei. Current uses of various internal targets and circulating particle beams in ongoing and projected research in particle physics, relativistic nuclear and spin physics, and physics of interactions of exotic and radioactive nuclei and for producing fluxes of secondary particles (mesons, neutrons, exotic and radioactive nuclei, etc.) for physics experiments are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Geo-Neutrinos and the Earth’s Internal Heat Flux

Predictions of geo-neutrino fluxes and the Earth’s internal heat flux made by the Hydride Earth model are discussed. The prediction of geo-neutrino fluxes can be consistent with experimental measured fluxes. The predicted value of the Earth’s internal heat flux is significantly larger than the value experimentally obtained under the assumption that the main mode of heat transport is thermal conductivity. We consider another mode of heat transport in the Earth’s crust: heat transport by hot gases created in the Earth’s crust at great depth. We discuss also experimental data supporting this idea, particularly the temperature profiles obtained in the Kola superdeep borehole.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗