Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Investigations in cosmic and gamma ray astronomy and nuclear instruments

The Nuclear Radiation Monitor (NRM) is flying on the Spacelab 2 vehicle as part of a set of instrumentation designed to measure the ambient physical environment on Spacelab in orbit. The NRM measures the natural and induced gamma ray activity. The instrument is constituted of a 25 sq in (NaI (T1)) crystal viewed with a single phototube and surrounded by a plastic anticoincidence shield. It is mounted on a pedestal and placed, with its electronics, on the Spacelab pallet. The detector head was designed and a development model fabricated and tested. Extensive software studies for on board and GSE microprocessors for use with the NRM were also made.

Gregory, J. C.↗

Error in Dasibi flight measurements of atmospheric ozone due to instrument wall-loss

Theory suggests that in laminar flow the percent loss of a trace constituent to the walls of a measuring instrument varies as P to the -2/3, where P is the total gas pressure. Preliminary laboratory ozone wall-loss measurements confirm this P to the -2/3 dependence. Accurate assessment of wall-loss is thus of particular importance for those balloon-borne instruments utilizing laminar flow at ambient pressure, since the ambient pressure decreases by a factor of 350 during ascent to 40 km. Measurements and extrapolations made for a Dasibi ozone monitor modified for balloon flight indicate that the wall-loss error at 40 km was between 6 and 30 percent and that the wall-loss error in the derived total ozone column-content for the region from the surface to 40 km altitude was between 2 and 10 percent. At 1000 mb, turbulence caused an order of magnitude increase in the Dasibi wall-loss.

Ainsworth, J. E.↗

Global auroral imaging instrumentation for the Dynamics Explorer Mission

The instrumentation for obtaining global images of the auroral oval from the high-altitude spacecraft of the Dynamics Explorer Mission is described. It is noted that the three spin-scan auroral imaging photometers are expected to be able to effectively view the dim emissions from earth in the presence of strong stray light sources near their fields-of-view along the sunlit portion of the spacecraft orbit. A special optical design that includes an off-axis parabolic mirror as the focusing element and super-reflecting mirror surfaces is used to minimize the effects of stray light. The rotation of the spacecraft and an instrument scanning mirror provide the two-dimensional array of pixels making up an image frame. It is pointed out that the full width of the fields-of-view of the photometers corresponding to a single pixel is 0.29 deg and that the angular dimensions of a typical full frame are 30 deg x 30 deg and span 14,400 pixels.

Frank, L. A.↗

Optical degradation due to contamination on the SAGE/SAGE II spacecraft instruments

An optical model for contamination effects has been developed for the SAGE II/ERBS instrument. This model describes instrument throughput efficiency and response characteristics as a function of molecular contamination thickness for indexes of refraction representative of Shuttle/ERBS/SAGE II contaminants at seven spectral wavelengths between 0.385 and 1.02 micrometers. Contamination effects are treated as thin film coatings on selected optical elements which cause changes in those elements' reflection/transmission/absorption characteristics. SAGE/AEM in-orbit performance data were used to estimate the optical constants for the contaminants. SAGE and SAGE II are radiometers that spatially scan the sun through the earth's atmosphere with a narrow field-of-view in spectral intervals from visible to the near infrared.

Mauldin, L. E., III↗

Solid state instrumentation concepts for earth resource observation

Late in 1980, specifications were prepared for detail design definition of a six band solid state multispectral instrument having three visible (VIS), one near infrared (NIR), and two short wave infrared (SWIR) bands. This instrument concept, known as the Multispectral Linear Array (MLA), also offered increased spatial resolution, on board gain and offset correction, and additional operational modes which would allow for cross track and stereoscopic viewing as well as a multialtitude operational capability. A description is presented of a summary of some of the salient features of four different MLA design concepts, as developed by four American companies. The designs ranged from the use of multiple refractive telescopes utilizing three groups of focal plane detectors electronic correlation processing for achieving spatial registration, and incorporating palladium silicide (PdSi) SWIR detectors, to a four-mirror all-reflective telecentric system utilizing a beam splitter for spatial registration.

Richard, H. L.↗

NASA/FAA Helicopter ATC simulation investigation of RNAV/MLS instrument approaches

The NASA/FAA Helicopter Air Traffic Control (ATC) simulation investigations to determine the feasibility of simultaneous, independent instrument approach procedures for helicopters at major terminal areas, using Area Navigation/Microwave Landing System (RNAV/MLS) guidance, was conducted at several levels of helicopter display sophistication, up to that of a Cockpit Display of Traffic Information (CDTI) system. Test objectives included the determination of pilot acceptability and the tracking performance of the RNAV/MLS's noninterfering rotorcraft approach path structure, along with the evaluation of the effect on controller workload of multiroute structures combining conventional and rotorcraft approaches at various arrival rates and traffic separations. The utility of electronic area maps and CDTI displays was also investigated. Participating pilots flew 127 simulated instrument approaches in an ATC simulation laboratory.

Peach, L. L., Jr.↗

Unmanned Instrument Platform for Undersea Exploration

Instruments accommodated on moving underwater platform. Towable underwater platform 3.2 meters long, 1.2 meters wide, 1.4 meters high and has mass of about 1,250 kilogram. Platform remotely operated and unmanned. Serves as test bed for development of ocean-measuring instruments and sonars at depths to 20,000 feet.

Paine, G.↗

Instrumentation and Control for Fossil-Energy Processes

Instrumentation and control requirements for fossil-energy processes discussed in working document. Published to foster advancement of instrumentation and control technology by making equipment suppliers and others aware of specifications, needs, and potential markets.

Mark, A., Jr.↗

Development and test of a Microwave Ice Accretion Measurement Instrument (MIAMI)

The development of an ice accretion measurement instrument that is a highly sensitive, accurate, rugged and reliable microprocessor controlled device using low level microwave energy for non-instrusive real time measurement and recording of ice growth history, including ice thickness and accretion rate is discussed. Data is displayed and recorded digitally. New experimental data is presented, obtained with the instrument, which demonstrates its ability to measure ice growth on a two-dimensional airfoil. The device is suitable for aircraft icing protection. It may be mounted flush, non-intrusively, on any part of an aircraft skin including rotor blades and engine inlets.

Magenheim, B.↗

A balloon-borne instrument for high-resolution astrophysical spectroscopy in the 20-8000 keV energy range

The Low Energy Gamma ray Spectrometer (LEGS) is designed to perform fine energy resolution measurements of astrophysical sources. The instrument is configured for a particular balloon flight with either of two sets of high purity germanium detectors. In one configuration, the instrument uses an array of three coaxial detectors (effective volume equal to or approximately 230 cubic cm) inside an NaI (T1) shield and collimator (field of view equal to or approximately 16 deg FWHM) and operates in the 80 to 8000 keV energy range. In the other configuration, three planar detectors (effective area equal to or approximately square cm) surrounded by a combination of passive Fe and active NaI for shielding and collimation (field of view equal to or approximately 5 deg x 10 deg FWHM) are optimized for the 20 to 200 keV energy range. In a typical one day balloon flight, LEGS sensitivity limit (3 sigma) for narrow line features is less than or approximately .0008 ph/cm/s square (coaxial array: 80 to 2000 keV) and less than or approximately .0003 ph/square cm/s (planar array: 50 to 150 keV).

Paciesas, W. S.↗

Airborne multispectral linear array instruments at Goddard Space Flight Center

The fabrication of airborne instruments is contributing to the development of multispectral linear array technology at NASA's Goddard Space Flight Center. The linear array pushbroom radiometer (LAPR-I), was built to demonstrate capabilities for acquiring digital image data using linear arrays. The LAPR-I employed three arrays of 512 silicon photodiodes each to simultaneously acquire three channels of data for spectral bands within the visible and near-infrared portions of the spectrum. A second instrument, LAPR-II, uses four arrays each consisting of 512 silicon detectors. A filter wheel containing six spectral filters is used in conjunction with each array to allow filter changes in flight. This capability will facilitate studies into the utility of various bands within the visible and near infrared portions of the spectrum. The LAPR-II's aircraft mounting will allow off-nadir pointing (plus-or-minus 50 deg fore-and-aft and side-to-side) which will enable investigations of the radiometric and geometric effects of off-nadir viewing. A short wave infrared radiometer is also described.

Irons, J. R.↗

Instrument for determining coincidence and elapse time between independent sources of random sequential events

An instrument that receives pulses from a primary external source and one or more secondary external sources and determines when there is coincidence between the primary and one of the secondary sources is described. The instrument generates a finite time window (coincidence aperture) during which coincidence is defined to have occurred. The time intervals between coincidence apertures in which coincidences occur are measured.

Clemmons, J. I., Jr.↗

The Deep Space Network: A Radio Communications Instrument for Deep Space Exploration

The primary purpose of the Deep Space Network (DSN) is to serve as a communications instrument for deep space exploration, providing communications between the spacecraft and the ground facilities. The uplink communications channel provides instructions or commands to the spacecraft. The downlink communications channel provides command verification and spacecraft engineering and science instrument payload data.

Renzetti, N. A.↗

The NASA Thunderstorm Overflight Program (TOP): Research in atmospheric electricity from an instrumented U-2 aircraft platform

An overview of the NASA Thunderstorm Overflight Program (TOP) is presented. The various instruments flown on the NASA U-2 aircraft, as well as the ground instrumentation used to collect optical and electronic signature from the lightning events, are discussed. Samples of some of the photographic and electronic signatures are presented. Approximately 6400 electronic data samples of optical pulses were collected and are being analyzed.

Vaughan, O. H., Jr.↗

Data enhancement and analysis through mathematical deconvolution of signals from scientific measuring instruments

Mathematical deconvolution of digitized analog signals from scientific measuring instruments is shown to be a means of extracting important information which is otherwise hidden due to time-constant and other broadening or distortion effects caused by the experiment. Three different approaches to deconvolution and their subsequent application to recorded data from three analytical instruments are considered. To demonstrate the efficacy of deconvolution, the use of these approaches to solve the convolution integral for the gas chromatograph, magnetic mass spectrometer, and the time-of-flight mass spectrometer are described. Other possible applications of these types of numerical treatment of data to yield superior results from analog signals of the physical parameters normally measured in aerospace simulation facilities are suggested and briefly discussed.

Wood, G. M.↗

Entropy, instrument scan, and pilot workload

Experimental results are presented from a set of experiments designed to explore the relationship between the performance, skill, and visual scanning behavior of pilots under varying levels of mental workload. Instrument fixations were recorded as groups of pilots with widely differing levels of skill simultaneously performed a continuous instrument flight task and a verbally presented loading task with four discrete levels. Pilot scanning patterns were found to be significantly affected by the level of mental workload in a manner that was dependent on skill. These scanning alterations were quantified by the methods of entropy and autocorrelation, where the former concerns visual scan path and the latter assesses the relations among scan periodicity, skill level and mental task periodicity.

Tole, J. R.↗

An instrument for rapidly measuring plasma distribution functions with high resolution

An instrument which can rapidly measure plasma particle distribution functions has been developed based upon recent innovations in electrostatic analyzer design and position sensitive particle detection. The new analyzer uses a quadrispherical geometry, but has a completely uniform 360 deg fan-shaped field of view. The polar angular distribution of entering particles is spatially imaged onto a position sensitive detector at the annular exit aperture after a deflection through 90 deg. Several methods of position sensitive detection have been successfully used in conjunction with this analyzer. The simplest is individual channel multipliers spaced around the annular exit. Microchannel plate electron multipliers permit greater position resolution to be obtained, and a detector using microchannel plates followed by a resistive anode image converter obtains angular resolution of about one degree, i.e., 360 individual angle pixels. Instruments of this type were flown on a sounding rocket in early 1982 and will be included on the Giotto comet mission and the AMPTE ion release module (IRM).

Carlson, C. W.↗

Optimizing a remote sensing instrument to measure atmospheric surface pressure

Atmospheric surface pressure can be remotely sensed from a satellite by an active instrument which measures return echoes from the ocean at frequencies near the 60 GHz oxygen absorption band. The instrument is optimized by selecting its frequencies of operation, transmitter powers and antenna size through a new procedure baesd on numerical simulation which maximizes the retrieval accuracy. The predicted standard deviation error in the retrieved surface pressure is 1 mb. In addition the measurements can be used to retrieve water vapor, cloud liquid water and sea state, which is related to wind speed.

Peckham, G. E.↗