Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Polarization lowering of charge injection barriers at a ribonucleic acid/Au interface

The orbital line-up at a ribonucleic acid (RNA)/Au interface was investigated using photoemission spectroscopy. The particular interface, polyuridine (polyrU) homopolymer/Au, was prepared by injecting polyrU in aqueous solution into vacuum through an electrospray deposition system. This enabled buildup of the interface in multiple growth steps with intermediate characterization by x-ray and ultraviolet photoemission spectroscopy measurements. The results suggest significant polarization effects in the RNA layer close to the interface as indicated by observed final state screening shifts in the photoemission spectra. The polarization at the interface causes a reduction in the electron and hole charge injection barriers, easing charge transfer between Au and polyrU.

74 ATOMIC AND MOLECULAR PHYSICS↗

Improved plasma uniformity in a discharge system with electron injection

We present the results of experiments leading to improvement in bulk plasma uniformity of a constricted-arc discharge system with electron injection. The steady-state discharge was in argon, at a gas pressure of 0.5 mTorr, and operated with a main discharge voltage between 20 and 100 V and current between 3 and 15 A. The radial plasma distribution was measured with a movable Langmuir probe. We find that geometric modification of the intermediate electrode exit aperture and the main discharge cathode add little to the plasma uniformity. Improved bulk plasma uniformity is observed when a special distributing grid electrode is used and the main discharge voltage is less than 20-30 V. The application of a weakly divergent magnetic field in the region of the intermediate electrode exit aperture decreases the plasma nonuniformity from 20% to 14% over a radial distance of 30 cm. The plasma uniformity was further improved by compensating the magnetic self-field of the injected electron beam by a reverse magnetic field produced with a special electrode compensator. It is shown that an increase in discharge current causes a proportional increase in back current in the distributing electrode. The approach allows a decrease in plasma nonuniformity from 20% to 13% over a radial distance of 30 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of off-axis neutral beam injection on sawtooth stability in ASDEX Upgrade and Mega-Ampere Spherical Tokamak

Sawtooth behavior has been investigated in plasmas heated with off-axis neutral beam injection in ASDEX Upgrade [A. Herrmann and O. Gruber, Fusion Sci. Technol. 44, 569 (2003)] and the Mega-Ampere Spherical Tokamak (MAST) [A. Sykes et al., Nucl. Fusion 41, 1423 (2001)]. Provided that the fast ions are well confined, the sawtooth period is found to decrease as the neutral beam is injected further off-axis. Drift kinetic modeling of such discharges qualitatively shows that the passing fast ions born outside the q=1 rational surface can destabilize the n=1 internal kink mode, thought to be related to the sawtooth instability. This effect can be enhanced by optimizing the deposition of the off-axis beam energetic particle population with respect to the mode location.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A method of particle transport study using supersonic molecular beam injection and microwave reflectometry on HL-2A tokamak

A method of the particle transport study using supersonic molecular beam injection (SMBI) and microwave reflectometry is reported in this paper. Experimental results confirm that pulsed SMBI is a good perturbation source with deeper penetration and better localization than the standard gas puffing. The local density modulation is induced using the pulsed SMBI and the perturbation density is measured by the microwave reflectometry. Using Fourier transform analysis for the local density perturbation, radial profiles of the amplitude and phase of the density modulation can be obtained. The experimental results in HL-2A show that the particle injected by SMBI is located at about r/a=0.65-0.75. The position of the main particle source can be determined through three aspects: the minimum of the phase of the first harmonic of the Fourier transform of the modulated density measured by microwave reflectometry; the H{sub a} intensity profile and the local density increase ratio. The maximum of the amplitude of the first harmonic shifts often inward relative to the particle source location, which indicates clearly there is an inward particle pinch in this area. Good agreement has been found between the experimental results and the simulation using analytical transport model. The particle diffusivity D and the particle convection velocity V have been obtained by doing this simulation. The sensitivity in the transport coefficients of the amplitude and the phase of the density modulation has been discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The injection efficiency measurement and analysis for central region model cyclotron

At the China Institute of Atomic Energy, a central region model cyclotron has been constructed, which is dedicated for various experimental verifications to study beam properties. The design features of the ion source and injection line have already been described in other papers. We shall report here the results of the initial beam tests. A wire scanner is employed in the injection line to measure beam transverse sizes and these data can be used to fit the phase plane parameters after the ion source. Based on the beam tests results, the ion source built in 2003 has been improved recently. The improvement is mainly due to the repair of the multicusp field. From the ion source to the exit of the inflector, a transmission efficiency of 93% has been obtained for a continuous and low current input beam. It is also described here the experimental arrangement and the results.

43 PARTICLE ACCELERATORS↗

PRESSURE FLUCTUATION BEHAVIOR IN THE CRYOGENIC HYDROGEN SYSTEM CAUSED BY A 100 kW PROTON BEAM INJECTION

Supercritical hydrogen (1.5 MPa and around 20 K) has been selected as a moderator material for the intense spallation neutron source (JSNS) in J-PARC. The cryogenic hydrogen system provides the supercritical hydrogen for the moderators and removes the nuclear heating at the moderators, which is estimated to be 3.8 kW for a proton beam power of 1 MW. The pressure control system was designed to mitigate pressure fluctuation caused by suddenly turning a proton beam on and off, which is composed of a heater as an active controller for thermal compensation and an accumulator as a passive volume controller. A 109 kW proton beam was injected to the JSNS in December 2007. The pressure fluctuation behaviors were studied for the 109 kW proton beam operation. As soon as the proton beam was injected, the accumulator spontaneously started to constrict. The heater control succeeded in maintaining a constant heat load applied to the cryogenic hydrogen system. The pressure control system successfully reduced the pressure fluctuation within 6 kPa. It was confirmed that the pressure control system was effective.

43 PARTICLE ACCELERATORS↗

Full Energy Injection and Top-up Operation at UVSOR-II

Top-up operation was successfully demonstrated at UVSOR-II, which will remove the short beam-lifetime problem caused by strong Touschek effect due to the small emittance, 27 nm-rad, and the low electron energy, 750 MeV. In these years, we have improved the accelerators, step by step, towards top-up operation. The radiation shielding wall was reconstructed. The energy of the booster synchrotron and the beam transport line were successfully upgraded from 600 MeV to 750 MeV, by replacing the magnet power supplies in 2006. Soon after, we succeeded in injecting the electron beam at the full energy. We improved the radiation safety system and constructed a injection control system. In autumn, 2008, we succeeded in operating the ring for 12 hours as keeping the beam current quasi-constant at 300 mA. Currently, we operated the ring in the top-up mode for 12 hours on every Thursday night, to check the effects on the users' experiments. In 2009, we have succeeded in the top-up operation in single bunch mode. Free electron laser oscillation with the top-up mode was also successfully demonstrated.

43 PARTICLE ACCELERATORS↗

Tuning the electron injection barrier between Co and C{sub 60} using Alq{sub 3} buffer layer

We demonstrate that the electron injection barrier ({Delta}{sub e}) between Co and C{sub 60} can be tuned by inserting a thin Alq{sub 3} interlayer. Using ultraviolet photoemission spectroscopy, {Delta}{sub e} of C{sub 60} on Alq{sub 3}-predecorated Co ({Delta}{sub e}=0.3 eV) was found to be reduced by 0.3 eV compared with that of C{sub 60} deposited directly on the bare Co metal surface ({Delta}{sub e}=0.6 eV). Due to Fermi level pining at the Alq{sub 3}/Co interface, this tuning effect is independent of the thickness of Alq{sub 3} interlayer from multilayer to monolayer. Based on the experimental results, band level alignment diagrams are proposed for C{sub 60}/Co and C{sub 60}/Alq{sub 3}/Co interfaces with two different Alq{sub 3} thicknesses. Our findings could have potential applications for the reduction in the carrier injection barrier in organic spin valves.

36 MATERIALS SCIENCE↗

Design and Interpretation of Colliding Pulse Injected Laser-Plasma Acceleration Experiments

The use of colliding laser pulses to control the injection of plasma electrons into the plasma wake of a laser-plasma accelerator is a promising approach to obtaining GeV scale electron bunches with reduced emittance and energy spread. Colliding Pulse Injection (CPI) experiments are being performed by groups around the world. We present recent particle-in-cell simulations, using the parallel VORPAL framework, of CPI for physical parameters relevant to ongoing experiments of the LOASIS program at LBNL. We perform parameter scans in order to optimize the quality of the bunch, and compare the results with experimental data. Effect of non-ideal gaussian pulses and laser self-focusing in the plasma channel on the trapped bunch are evaluated. For optimized parameters accessible in the experiment, a 20 pC electron beam can be accelerated to 300 MeV with percent level energy spread.

43 PARTICLE ACCELERATORS↗

Work function measurements during plasma exposition at conditions relevant in negative ion sources for the ITER neutral beam injection

Cesium seeded sources for surface generated negative hydrogen ions are major components of neutral beam injection systems in future large-scale fusion experiments such as ITER. The stability and delivered current density depend highly on the work function during vacuum and plasma phases of the ion source. One of the most important quantities that affect the source performance is the work function. A modified photocurrent method was developed to measure the temporal behavior of the work function during and after cesium evaporation. The investigation of cesium exposed Mo and MoLa samples under ITER negative hydrogen ion based neutral beam injection relevant surface and plasma conditions showed the influence of impurities which result in a fast degradation when the plasma exposure or the cesium flux onto the sample is stopped. A minimum work function close to that of bulk cesium was obtained under the influence of the plasma exposition, while a significantly higher work function was observed under ITER-like vacuum conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Speed Si Etching with ClF{sub 3} Cluster Injection

The reactive gas cluster injection process is an etching method that uses a neutral cluster beam without plasma. ClF{sub 3}-Ar neutral cluster was generated and the Si etching characteristics with this beam were investigated. ClF{sub 3} is very high reactive gas. Adiabatic expansion of a high-pressure gas through a conical nozzle is utilized for the formation of cluster beams. The source gas was a mixture of ClF{sub 3}(6%) with Ar (94%). The etching rate increased with source gas pressure nonlinearly, and the etching rate achieved more than 30 {mu}m/min at 0.85 MPa. Although the irradiation energy was very low (<1 eV/atom or molecule), the chemical etching was enhanced with cluster impacts and the cluster bombarded area on the surface was etched selectively. These results indicated that high speed anisotropic etching with low damage can be realized with the ClF{sub 3} cluster injection process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New ion source for KSTAR neutral beam injection system

The neutral beam injection system (NBI-1) of the KSTAR tokamak can accommodate three ion sources; however, it is currently equipped with only one prototype ion source. In the 2010 and 2011 KSTAR campaigns, this ion source supplied deuterium neutral beam power of 0.7-1.6 MW to the KSTAR plasma with a beam energy of 70-100 keV. A new ion source will be prepared for the 2012 KSTAR campaign with a much advanced performance compared with the previous one. The newly designed ion source has a very large transparency ({approx}56%) without deteriorating the beam optics, which is designed to deliver a 2 MW injection power of deuterium beams at 100 keV. The plasma generator of the ion source is of a horizontally cusped bucket type, and the whole inner wall, except the cathode filaments and plasma grid side, functions as an anode. The accelerator assembly consists of four multi-circular aperture grids made of copper and four electrode flanges made of aluminum alloy. The electrodes are insulated using PEEK. The ion source will be completed and tested in 2011.

43 PARTICLE ACCELERATORS↗

Multifunctional bulk plasma source based on discharge with electron injection

A bulk plasma source, based on a high-current dc glow discharge with electron injection, is described. Electron injection and some special design features of the plasma arc emitter provide a plasma source with very long periods between maintenance down-times and a long overall lifetime. The source uses a sectioned sputter-electrode array with six individual sputter targets, each of which can be independently biased. This discharge assembly configuration provides multifunctional operation, including plasma generation from different gases (argon, nitrogen, oxygen, acetylene) and deposition of composite metal nitride and oxide coatings.

36 MATERIALS SCIENCE↗

Experimental and computational study of the injection of antiprotons into a positron plasma for antihydrogen production

One of the goals of synthesizing and trapping antihydrogen is to study the validity of charge-parity-time symmetry through precision spectroscopy on the anti-atoms, but the trapping yield achieved in recent experiments must be significantly improved before this can be realized. Antihydrogen atoms are commonly produced by mixing antiprotons and positrons stored in a nested Penning-Malmberg trap, which was achieved in ALPHA by an autoresonant excitation of the antiprotons, injecting them into the positron plasma. In this work, a hybrid numerical model is developed to simulate antiproton and positron dynamics during the mixing process. The simulation is benchmarked against other numerical and analytic models, as well as experimental measurements. The autoresonant injection scheme and an alternative scheme are compared numerically over a range of plasma parameters which can be reached in current and upcoming antihydrogen experiments, and the latter scheme is seen to offer significant improvement in trapping yield as the number of available antiprotons increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impurity mixing and radiation asymmetry in massive gas injection simulations of DIII-D

Simulations of neon massive gas injection into DIII-D are performed with the 3D MHD code NIMROD. The poloidal and toroidal distribution of the impurity source is varied. This report will focus on the effects of the source variation on impurity mixing and radiated power asymmetry. Even toroidally symmetric impurity injection is found to produce asymmetric radiated power due to asymmetric convective heat flux produced by the 1/1 mode. When the gas source is toroidally localized, the phase relationship between the mode and the source location is important, affecting both radiation peaking and impurity mixing. Under certain circumstances, a single, localized gas jet could produce better radiation symmetry during the disruption thermal quench than evenly distributed impurities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Induction of electron injection and betatron oscillation in a plasma-waveguide-based laser wakefield accelerator by modification of waveguide structure

By adding a transverse heater pulse into the axicon ignitor-heater scheme for producing a plasma waveguide, a variable three-dimensionally structured plasma waveguide can be fabricated. With this technique, electron injection in a plasma-waveguide-based laser wakefield accelerator was achieved and resulted in production of a quasi-monoenergetic electron beam. The injection was correlated with a section of expanding cross-section in the plasma waveguide. Moreover, the intensity of the X-ray beam produced by the electron bunch in betatron oscillation was greatly enhanced with a transversely shifted section in the plasma waveguide. The technique opens a route to a compact hard-X-ray pulse source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A simple scheme for injection and extraction in compact rings

There has been great interest in building compact synchrotrons for various applications, for example, inverse Compton scattering X-ray sources. However, the beam injection and extraction in compact rings require careful design for the lack of space. In this paper, we propose a simple combined injection-extraction scheme exploiting the fringe field of existing dipole magnets instead of additional septum magnets. This scheme is illustrated by using the 4.8 m ring proposed for Tsinghua Thomson scattering X-ray source as an example. Particle tracking is applied to demonstrate the validity of this scheme.

43 PARTICLE ACCELERATORS↗

Scattering assisted injection based injectorless mid infrared quantum cascade laser

An injectorless five-well mid infrared quantum cascade laser is analyzed which relies on phonon scattering injection in contrast to resonant tunneling injection, which has been previously used for injectorless designs. A Monte Carlo based self-consistent electron and photon transport simulator is used to analyze the performance of the analyzed design and compare it to existing injectorless designs. The simulation results show that the analyzed design could greatly enhance the optical gain and the characteristic temperatures of injectorless quantum cascade lasers (QCLs) which have typically been hindered by low characteristic temperatures and significant temperature related performance degradation. Simulations of the analyzed device predict threshold current densities of 0.85 kA/cm{sup 2} and 1.95 kA/cm{sup 2} at 77 K and 300 K, respectively, which are comparable to the threshold current densities of conventional injector based QCLs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗