Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Implants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Reduction of Respiratory Liver Tumor Motion by Abdominal Compression in Stereotactic Body Frame, Analyzed by Tracking Fiducial Markers Implanted in Liver

Purpose: To investigate in a three-dimensional framework the effectiveness and reproducibility of reducing the respiratory motion of liver tumors using abdominal compression in a stereotactic body frame. Methods and Materials: A total of 12 patients with liver tumors, who were treated with stereotactic body radiotherapy, were included in this study. These patients had three gold fiducial markers implanted in the healthy liver tissue surrounding the tumor. Fluoroscopic videos were acquired on the planning day and before each treatment fraction to visualize the motion of the fiducial markers during free breathing and varying levels of abdominal compression. Software was developed to track the fiducial markers and measure their excursions. Results: Abdominal compression reduced the patient group median excursion by 62% in the craniocaudal and 38% in the anteroposterior direction with respect to the median free-breathing excursions. In the left-right direction, the median excursion increased 15% (maximal increase 1.6 mm). The median residual excursion was 4.1 mm in the craniocaudal, 2.4 mm in the anteroposterior, and 1.8 mm in the left-right direction. The mean excursions were reduced by compression to <5 mm in all patients and all directions, with two exceptions (craniocaudal excursion reduction of 20.5 mm to 7.4 mm and of 21.1 mm to 5.9 mm). The residual excursions reproduced well during the treatment course, and the craniocaudal excursions measured on the treatment days were never significantly ({alpha} = 0.05) greater than on the planning days. Fine tuning the compression did not considerably change the excursion on the treatment days. Conclusions: Abdominal compression effectively reduced liver tumor motion, yielding small and reproducible excursions in three dimensions. The compression level established at planning could have been safely used on the treatment days.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrospective Comparison of Chemoradiotherapy Followed by Adjuvant Chemotherapy, With or Without Prior Gliadel Implantation (Carmustine) After Initial Surgery in Patients With Newly Diagnosed High-Grade Gliomas

Purpose: Retrospective study of patients treated for high-grade glioma, with or without biodegradable carmustine wafers and according to the Stupp protocol. Methods and Materials: Between May 2007 and June 2008, 65 patients underwent surgery for high-grade glioma, 28 had implantation of Gliadel and 37 patients did not. Patients received radiotherapy with concomitant temozolomide followed by 5 consecutive days of temozolomide every month for 6 months. Results: Overall median follow-up was 17.1 months; the median relapse-free survival (RFS) was 14 months with a RFS of 54% at 12 months, and 38% at 24 months. For patient with and without Gliadel, median and 1-year RFS were 12.9 months and 52% vs. 14 months and 42%, respectively (p = 0.89). According to pathology, Gliadel did not influence RFS of patients with Grade III or glioblastoma. However, for all patients, in multivariate analysis, non-methylated methylguanine methyltransferase (MGMT) was the only unfavorable prognostic factor of RFS (p = 0.017; HR 2.8; CI [1.2-7]). Median overall survival (OS) was 20.8 months; the OS rate at 12 months was 78.5%, and at 24 months 35.4%. For patients treated with and without Gliadel, median and 1-year OS were 20.6 months and 78.6% vs. 20.8 months and 78.4%, respectively. According to pathology, Gliadel did not influence OS of patients with Grade III or glioblastoma. For all patients, in multivariate analysis, unfavorable prognosticators for OS were non-methylated MGMT (p = 0.001; HR: 6.5; CI [2-20]) and irradiation dose <60 Gy (p = 0.02; HR: 6.3; CI [2-20]). With carmustine wafers, before irradiation, median gross tumor volume plus edema was 84 mL (27-229), whereas it was 68 mL (10-362) without carmustine (p = nonsignificant). Four cases of Grade 3 thrombopenia occurred, all in the carmustine wafer group. Conclusion: In patients with high-grade gliomas, adding Gliadel before performing a Stupp protocol did not improve survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kilovoltage Imaging of Implanted Fiducials to Monitor Intrafraction Motion With Abdominal Compression During Stereotactic Body Radiation Therapy for Gastrointestinal Tumors

Purpose: To assess intrafraction respiratory motion using a commercial kilovoltage imaging system for abdominal tumor patients with implanted fiducials and breathing constrained by pneumatic compression during stereotactic body radiation therapy (SBRT). Methods and Materials: A pneumatic compression belt limited respiratory motion in 19 patients with radiopaque fiducials in or near their tumor during SBRT for abdominal tumors. Kilovoltage images were acquired at 5- to 6-second intervals during treatment using a commercial system. Intrafractional fiducial displacements were measured using in-house software. The dosimetric effect of the observed displacements was calculated for 3 sessions for each patient. Results: Intrafraction displacement patterns varied between patients and between individual treatment sessions. Averaged over 19 patients, 73 sessions, 7.6% of craniocaudal displacements exceeded 0.5 cm, and 1.2% exceeded 0.75 cm. The calculated single-session dose to 95% of gross tumor volume differed from planned by an average of −1.2% (range, −11.1% to 4.8%) but only for 4 patients was the total 3-session calculated dose to 95% of gross tumor volume more than 3% different from planned. Conclusions: Our pneumatic compression limited intrafractional abdominal target motion, maintained target position established at setup, and was moderately effective in preserving coverage. Commercially available intrafractional imaging is useful for surveillance but can be made more effective and reliable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exceptional radiation resistance of hardened amorphous SiC under high-temperature hydrogen ion implantation

This study provides a compelling comparison of the structural and mechanical responses of single-crystal silicon carbide (sc-SiC), nanocrystalline silicon carbide (nc-SiC), and amorphous silicon carbide (am-SiC) to hydrogen ion implantation at 650 °C across three distinct fluences: low, medium, and high (LF, MF, HF). While both sc-SiC and nc-SiC exhibit blistering, microcracking, and exfoliation, am-SiC remains free of blisters, demonstrating superior resilience. Notably, nc-SiC, with its high density of stacking faults (SFs), requires a higher fluence to initiate blistering compared to sc-SiC. At high fluences, hydrogen accumulation at grain boundaries (GBs) in nc-SiC elevates internal gas pressure, intensifying exfoliation. In sc-SiC, blistering leads to increased hardness, whereas in nc-SiC, the degradation of the SF structure results in a reduction in hardness. In contrast, am-SiC undergoes structural relaxation during irradiation, resulting in a significant increase in hardness while maintaining its structural integrity, with only the formation of nano-sized spherical bubbles observed. Furthermore, these findings highlight the exceptional suitability of am-SiC for nuclear applications, where resistance to radiation-induced microcracking is critical.

36 MATERIALS SCIENCE↗

Helium effects on microstructural evolution in tempered martensitic steels: In situ helium implanter studies in HFIR

Microstructural evolutions in tempered martensitic steels (TMS) under neutron-irradiation, at fusion relevant He/dpa ratios and dpa rates, were characterized using a novel in situ He-implanter technique. F82H-mod3 was irradiated at 500 C in HFIR to a nominal 9 dpa and 190 or 380 appm He in both in the as-tempered (AT) and 20% cold-worked (CW) conditions. In all cases, a high number density of 1-2 nm He-bubbles were observed, along with fewer but larger 10 nm void-like faceted cavities. The He-bubbles form preferentially on dislocations and various interfaces. A slightly larger number of smaller He bubbles were observed in the CW condition. The lower He/dpa ratio produced slightly smaller and fewer He-bubbles. Comparisons of these observations to the results in nano-structured ferritic alloy (NFA) MA957 provide additional evidence that TMS may be susceptible to He-embrittlement as well as void swelling at fusion relevant He concentrations, while NFA are much more resistant to these degradation phenomena.

36 MATERIALS SCIENCE↗

Bubble morphology in U 3 Si 2 implanted by high-energy Xe ions at 300 °C

The microstructure modifications of a high-energy Xe implanted U 3 Si 2 , a promising accident tolerant fuel candidate, were characterized and are reported upon. The U 3 Si 2 pellet was irradiated at Argonne Tandem Linac Accelerator System (ATLAS) by an 84 MeV Xe ion beam at 300 °C. The irradiated specimen was then investigated using a series of transmission electron microscopy (TEM) techniques. A dense distribution of bubbles were observed near the range of the 84 MeV Xe ions. Xe gas was also found to accumulate at multiple types of sinks, such as dislocations and grain boundaries. Bubbles aggregated at those sinks are slightly larger than intragranular bubbles in lattice. At 300 °C, the gaseous swelling strain is limited as all the bubbles are below 10 nm, implying the promising fission gas behavior of U 3 Si 2 under normal operating conditions in light water reactors (LWRs).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phase decomposition and bubble evolution in Xe implanted U 3 Si 2 at 450°C

We report on the microstructure investigations of a U 3 Si 2 specimen implanted by 84 MeV Xe ions at 450°C. In the region that corresponds to the highest irradiation dose, U 3 Si 2 was found to decompose into a Si-enriched nanocrystalline USi matrix phase and a U-enriched amorphous inclusion phase. Density functional theory (DFT) calculations were used to help understand the decomposition mechanism. Xe bubbles of different morphologies were observed in USi nano-grains, on USi grain boundaries, and phase boundaries. Original U 3 Si 2 micro-grains were preserved on both sides of the irradiation damage peak region within the sample, implying a radiation dose threshold for decomposition of approximately 150 dpa at 450°C. In the preserved U 3 Si 2 region beneath the irradiation damage peak, where critical amount of Xe ions were deposited, a monomodal size distribution of intragranular Xe bubbles with an average size of 2.68 nm formed. In both decomposed and preserved U 3 Si 2 , the size of Xe bubbles was found to be lower than 50 nm. Based on this observation, the fission gas behavior of U 3 Si 2 is controllable and free of run-away swelling despite the occurrence of decomposition at this irradiation temperature. (C) 2019 Elsevier B.V. All rights reserved.

36 MATERIALS SCIENCE↗

Combined effect of injected interstitials and He implantation, and cavities inside dislocation loops in high purity Fe-Cr alloys

High purity Fe-Cr alloys with Cr content ranging from 3 to 14 wt% were irradiated by self-ions at 500 °C in dual-beam mode up to 157 displacements per atom (dpa), 17 appm He/dpa. Transmission electron microscopy (TEM) on focused ion beam foils revealed the depth distribution of irradiation induced cavities and dislocation loops. A detailed quantitative analysis of cavity microstructure was performed on Fe14%Cr, while Fe(3, 5, 10, 12)%Cr were analyzed qualitatively. A homogeneous distribution of small cavities were observed up to the damage peak. From surface to the damage peak, cavity number density increased almost linearly. The cavity microstructure changed drastically at and after the damage peak, where the size increased and number density decreased. Most notably, the microstructure consisted of a striking mixture of heterogeneously nucleated cavities inside dislocation loops and freely nucleated cavities in the matrix. Further, the depth-dependent void swelling increased continuously along the damage depth. This contrasts with most ion irradiation results where suppression of void swelling occurs adjacent to the damage peak due the injected interstitial effect. We hypothesize a plausible mechanism of the observed swelling variation based on a combined effect of the injected interstitials and helium implantation near the damage peak by comparing the results with those in pure iron irradiated under same conditions. This synergistic effect may develop cavity microstructures which do not necessarily reflect microstructures expected due to injected interstitial effect and can be easily wrongly interpreted. The depth dependent dislocation loop microstructure was studied qualitatively in Fe14%Cr sample. Up to the damage peak, a complex dense network of dislocations formed due to the interaction/impingement of the dislocation loops. Individually resolvable loops were only observed after the damage peak, where their association with cavities was noted. Furthermore helium also induced heterogeneous cavity nucleation on dislocations constituting a grain boundary and on pre-existing dislocation lines.

36 MATERIALS SCIENCE↗

Estimating dose to implantable cardioverter-defibrillator outside the treatment fields using a skin QED diode, optically stimulated luminescent dosimeters, and LiF thermoluminescent dosimeters

The purpose of this work was to determine the relative sensitivity of skin QED diodes, optically stimulated luminescent dosimeters (OSLDs) (microStar Trade-Mark-Sign DOT, Landauer), and LiF thermoluminescent dosimeters (TLDs) as a function of distance from a photon beam field edge when applied to measure dose at out-of-field points. These detectors have been used to estimate radiation dose to patients' implantable cardioverter-defibrillators (ICDs) located outside the treatment field. The ICDs have a thin outer case made of 0.4- to 0.6-mm-thick titanium ({approx}2.4-mm tissue equivalent). A 5-mm bolus, being the equivalent depth of the devices under the patient's skin, was placed over the ICDs. Response per unit absorbed dose-to-water was measured for each of the dosimeters with and without bolus on the beam central axis (CAX) and at a distance up to 20 cm from the CAX. Doses were measured with an ionization chamber at various depths for 6- and 15-MV x-rays on a Varian Clinac-iX linear accelerator. Relative sensitivity of the detectors was determined as the ratio of the sensitivity at each off-axis distance to that at the CAX. The detector sensitivity as a function of the distance from the field edge changed by {+-} 3% (1-11%) for LiF TLD-700, decreased by 10% (5-21%) for OSLD, and increased by 16% (11-19%) for the skin QED diode (Sun Nuclear Corp.) at the equivalent depth of 5 mm for 6- or 15-MV photon energies. Our results showed that the use of bolus with proper thickness (i.e., {approx}d{sub max} of the photon energy) on the top of the ICD would reduce the scattered dose to a lower level. Dosimeters should be calibrated out-of-field and preferably with bolus equal in thickness to the depth of interest. This can be readily performed in clinic.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optical properties of implanted Xe color centers in diamond

Optical properties of color centers in diamond have been the subject of intense research due to their promising applications in quantum photonics. Here in this work we study the optical properties of Xe related color centers implanted into nitrogen rich (type IIA) and an ultrapure, electronic grade diamond. The Xe defect has two zero phonon lines at 794 nm and 811 nm, which can be effectively excited using both green and red excitation, however, its emission in the nitrogen rich diamond is brighter. Near resonant excitation is performed at cryogenic temperatures and luminescence is probed under strong magnetic field. Finally, our results are important towards the understanding of the Xe related defect and other near infrared color centers in diamond.

36 MATERIALS SCIENCE↗

Erbium-Implanted WS 2 Flakes with Room-Temperature Photon Emission at Telecom Wavelengths

Optically addressable spin impurities in crystals along with device engineering provide an attractive route to realizing quantum technologies in the solid state, but reconciling disparate emitter and host material constraints for a given target application is often challenging. Rare-earth ions in two-dimensional (2D) materials could mitigate this problem given the atomic-like transitions of the emitters and the versatile nature of van der Waals systems. Here we combine ion implantation, confocal microscopy, and ab initio calculations to examine the photon emission of Er-doped WS 2 flakes. Optical spectroscopy reveals narrow, long-lived photoluminescence lines in the telecom band, which we activate after low-temperature thermal annealing. Spectroscopic and polarization-selective measurements show a uniform response across the ensemble, while the fluorescence brightness remains mostly unchanged with temperature, suggesting nonradiative relaxation channels are inefficient. Our results create opportunities for novel solid state devices coupling 2D-hosted, telecom-band emitters to photonic heterostructures separately optimized for photon manipulation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Helium Irradiation and Implantation Effects on the Structure of Amorphous Silicon Oxycarbide

Despite recent interest in amorphous ceramics for a variety of nuclear applications, many details of their structure before and after irradiation/implantation remain unknown. Here we investigated the short-range order of amorphous silicon oxycarbide (SiOC) alloys by using the atomic pair-distribution function (PDF) obtained from electron diffraction. The PDF results show that the structure of SiOC alloys are nearly unchanged after both irradiation up to 30 dpa and He implantation up to 113 at%. TEM characterization shows no sign of crystallization, He bubble or void formation, or segregation in all irradiated samples. Irradiation results in a decreased number of Si-O bonds and an increased number of Si-C and C-O bonds. This study sheds light on the design of radiation-tolerant materials that do not experience helium swelling for advanced nuclear reactor applications.

36 MATERIALS SCIENCE↗

A 3D approximate maximum likelihood solver for localization of fish implanted with acoustic transmitters

Better understanding of fish behavior is vital for recovery of many endangered species including salmon. The Juvenile Salmon Acoustic Telemetry System (JSATS) was developed to observe the out-migratory behavior of juvenile salmonids tagged by surgical implantation of acoustic micro-transmitters and to estimate the survival when passing through dams on the Snake and Columbia Rivers. A robust three-dimensional solver was needed to accurately and efficiently estimate the time sequence of locations of fish tagged with JSATS acoustic transmitters, to describe in sufficient detail the information needed to assess the function of dam-passage design alternatives. An approximate maximum likelihood solver was developed using measurements of time difference of arrival from all hydrophones in receiving arrays on which a transmission was detected. Field experiments demonstrated that the developed solver performed significantly better in tracking efficiency and accuracy than other solvers described in the literature.

60 APPLIED LIFE SCIENCES↗

Silicon electronics on silk as a path to bioresorbable, implantable devices

Many existing and envisioned classes of implantable biomedical devices require high performance electronics/sensors. An approach that avoids some of the longer term challenges in biocompatibility involves a construction in which some parts or all of the system resorbs in the body over time. Furthermore, this paper describes strategies for integrating single crystalline silicon electronics, where the silicon is in the form of nanomembranes, onto water soluble and biocompatible silk substrates. Electrical, bending, water dissolution, and animal toxicity studies suggest that this approach might provide many opportunities for future biomedical devices and clinical applications.

42 ENGINEERING↗

Recoil-Implantation Of Multiple Radioisotopes Towards Wear Rate Measurements And Particle Tracing In Prosthetic Joints

This study demonstrates a new method of radioisotope labeling of ultra-high molecular weight polyethylene inserts in prosthetic joints for wear studies. The radioisotopes {sup 97}Ru, {sup 100}Pd, {sup 100}Rh, and {sup 101m}Rh are produced in fusion evaporation reactions induced by {sup 12}C ions in a {sup 92}Zr target foil. The fusion products recoil-implant into ultra-high molecular weight polyethylene plugs, machined to fit into the surface of the inserts. During laboratory simulations of the joint motion, a wear rate of the labeled polyethylene may be measured and the pathways of wear debris particles can be traced by detecting characteristic gamma-rays. The concentration profiles of the radioisotopes extend effectively uniformly from the polyethylene surface to a depth of about 4 {mu}m. The multiplicity of labeling and the use of several gamma-ray lines aids with avoiding systematic measurement uncertainties. Two polyethylene plugs were labeled and one was fitted into the surface of the tibial insert of a knee prosthesis, which had been worn in. Actuation over close to 100,000 cycles with a 900 N axial load and a 24 deg. flexion angle removed (14{+-}1)% of the gamma-ray activity from the plug. Most of this activity dispersed into the serum lubricant identifying this as the important debris pathway. Less than 1% activity was transferred to the femoral component of the prosthesis and the measured activity on the tibial tray was insignificant. Assuming uniform wear across the superior surface of the insert, a wear rate of (12{+-}3) mm{sup 3}/Megacycle was determined. This is consistent with wear rate measurements under similar conditions using other techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of n{sup +} and p{sup +} doping on the lattice sites of implanted Fe in Si

We report on the lattice location of implanted {sup 59}Fe in n{sup +}- and p{sup +}-type Si by means of emission channeling. We found clear evidence that the preferred lattice location of Fe changes with the doping of the material. While in n{sup +}-type Si Fe prefers displaced bond-centered (BC) sites for annealing temperatures up to 600 °C, changing to ideal substitutional sites above 700 °C, in p{sup +}-type Si, Fe prefers to be in displaced tetrahedral interstitial positions after all annealing steps. The dominant lattice sites of Fe in n{sup +}-type Si therefore seem to be well characterized for all annealing temperatures by the incorporation of Fe into vacancy-related complexes, either into single vacancies which leads to Fe on ideal substitutional sites, or multiple vacancies, which leads to its incorporation near BC sites. In contrast, in p{sup +}-type Si, the major fraction of Fe is clearly interstitial (near-T or ideal T) for all annealing temperatures. The formation and possible lattice sites of Fe in FeB pairs in p{sup +}-Si are discussed. We also address the relevance of our findings for the understanding of the gettering effects caused by radiation damage or P-diffusion, the latter involving n{sup +}-doped regions.

36 MATERIALS SCIENCE↗