Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heart Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Current Role of the Total Artificial Heart in the Management of Advanced Heart Failure

The total artificial heart (TAH) is a form of mechanical circulatory support that involves resection of the native ventricles followed by placement of a device that can restore total pulmonary and systemic flow. Given the increasing burden of congestive heart failure and cardiovascular disease, the number of people in need of cardiac replacement therapy will continue to grow. Despite aggressive efforts to expand the donor pool, the number of heart transplants in the United States (US) has plateaued at less than 3000 per year. In addition, there is increasing recognition of the long-term complications of current generation left ventricular assist devices such as progressive aortic insufficiency, complications related to blood trauma, and both early and delayed right ventricular failure. These factors may serve to expand the role of the TAH in the treatment of patients with end-stage heart failure particularly if new generation devices are developed that are durable, have an improved safety profile, and are totally implantable. Purpose of Review: To review the role and current evidence of the use of the TAH in the management of advanced heart failure and discuss development of recent TAHs that may have an impact on the field in the near future. Recent Findings: Many patients that receive a heart transplant are bridged with a mechanical support device, most commonly a left ventricular assist device (LVAD). However, there is a small subset of patients with profound biventricular (BV) failure or structural abnormalities that preclude LVAD placement, who will require support with a biventricular assist device (BiVAD) or TAH. There are numerous studies showing the efficacy of the TAH in bridging to transplantation. Also, recent studies have shown equal rates of bridging to transplantation between patients receiving a TAH compared to a BiVAD. However, BiVAD support has a higher incidence of stroke in addition to complications related to the native heart such as arrhythmias and valve dysfunction. Currently, there are multiple new generation artificial hearts in both preclinical development and in clinical trials for both bridge to transplant and destination therapy. Summary: TAH have been shown to be effective for circulatory support in select patients with end-stage heart failure. Current LVADs are associated with significant long-term complications related to retention of the native heart and pump design. Many of these complications may be addressed by the increased use of cardiac replacement therapy, i.e., total artificial hearts. Multiple generations of both pulsatile and advanced design continuous flow TAH are under development which have the potential to expand the role of TAHs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Longitudinal Evaluation of Myocardial Fatty Acid and Glucose Metabolism in Fasted and Nonfasted Spontaneously Hypertensive Rats Using MicroPET/CT

Using longitudinal micro positron emission tomography (microPET)/computed tomography (CT) studies, we quantified changes in myocardial metabolism and perfusion in spontaneously hypertensive rats (SHRs), a model of left ventricular hypertrophy (LVH). Fatty acid and glucose metabolism were quantified in the hearts of SHRs and Wistar-Kyoto (WKY) normotensive rats using long-chain fatty acid analog 18F-fluoro-6-thia heptadecanoic acid ( 18 F-FTHA) and glucose analog 18 F-fluorodeoxyglucose ( 18 F-FDG) under normal or fasting conditions. We also used 18 F-fluorodihydrorotenol ( 18 F-FDHROL) to investigate perfusion in their hearts without fasting. Rats were imaged at 4 or 5 times over their life cycle. Compartment modeling was used to estimate the rate constants for the radiotracers. Blood samples were obtained and analyzed for glucose and free fatty acid concentrations. SHRs demonstrated no significant difference in 18 F-FDHROL wash-in rate constant (P = .1) and distribution volume (P = .1), significantly higher 18 F-FDG myocardial influx rate constant (P = 4×10 –8 ), and significantly lower 18 F-FTHA myocardial influx rate constant (P = .007) than WKYs during the 2009-2010 study without fasting. SHRs demonstrated a significantly higher 18F-FDHROL wash-in rate constant (P = 5×10 –6 ) and distribution volume (P = 3×10 –8 ), significantly higher 18 F-FDG myocardial influx rate constant (P = 3×10 –8 ), and a higher trend of 18 F-FTHA myocardial influx rate constant (not significant, P = .1) than WKYs during the 2011–2012 study with fasting. Changes in glucose plasma concentrations were generally negatively correlated with corresponding radiotracer influx rate constant changes. The study indicates a switch from preferred fatty acid metabolism to increased glucose metabolism with hypertrophy. Increased perfusion during the 2011-2012 study may be indicative of increased aerobic metabolism in the SHR model of LVH.

59 BASIC BIOLOGICAL SCIENCES↗

The Galactic Cosmic Ray Simulator at the NASA Space Radiation Research Laboratory

With NASA’s new Artemis plan for a sustainable return to the moon, astronauts will once again leave Earth’s protective magnetosphere only to endure higher levels of radiation from galactic cosmic radiation (GCR). The ever penetrating GCR will continue to pose significant health risks especially as lunar missions increase in duration and as NASA sets its aspirations on Mars. The primary risks of concern include carcinogenesis, central nervous system (CNS) effects resulting in potential in-mission cognitive or behavioral impairment and/or late neurological disorders, and degenerative tissue effects including circulatory and heart disease. Characterization and mitigation of these risks requires a significant reduction in the large biological uncertainties of chronic (low-dose rate) heavy ion exposures and the validation of countermeasures in a relevant space environment. Historically, most research on understanding space radiation-induced health risks has been performed using acute exposures of monoenergetic single-ion beams. However, the space radiation environment consists of a wide variety of ion species over a broad energy range. Using the fast beam switching and controls systems technology recently developed at the NASA Space Radiation Laboratory at Brookhaven National Laboratory, a new era in radiobiological research is possible. NASA has developed the “GCR simulator” to generate a spectrum of ion beams that approximates the primary and secondary GCR field experienced at human organ locations within a deep-space vehicle.

NASA Space Radiation Laboratory↗

Dummy Run of Quality Assurance Program in a Phase 3 Randomized Trial Investigating the Role of Internal Mammary Lymph Node Irradiation in Breast Cancer Patients: Korean Radiation Oncology Group 08-06 Study

Purpose: The Korean Radiation Oncology Group (KROG) 08-06 study protocol allowed radiation therapy (RT) technique to include or exclude breast cancer patients from receiving radiation therapy to the internal mammary lymph node (IMN). The purpose of this study was to assess dosimetric differences between the 2 groups and potential influence on clinical outcome by a dummy run procedure. Methods and Materials: All participating institutions were asked to produce RT plans without irradiation (Arm 1) and with irradiation to the IMN (Arm 2) for 1 breast-conservation treatment case (breast-conserving surgery [BCS]) and 1 mastectomy case (modified radical mastectomy [MRM]) whose computed tomography images were provided. We assessed interinstitutional variations in IMN delineation and evaluated the dose-volume histograms of the IMN and normal organs. A reference IMN was delineated by an expert panel group based on the study guidelines. Also, we analyzed the potential influence of actual dose variation observed in this study on patient survival. Results: Although physicians intended to exclude the IMN within the RT field, the data showed almost 59.0% of the prescribed dose was delivered to the IMN in Arm 1. However, the mean doses covering the IMN in Arm 1 and Arm 2 were significantly different for both cases (P<.001). Due to the probability of overdose in Arm 1, the estimated gain in 7-year disease-free survival rate would be reduced from 10% to 7.9% for BCS cases and 7.1% for MRM cases. The radiation doses to the ipsilateral lung, heart, and coronary artery were lower in Arm 1 than in Arm 2. Conclusions: Although this dummy run study indicated that a substantial dose was delivered to the IMN, even in the nonirradiation group, the dose differences between the 2 groups were statistically significant. However, this dosimetric profile should be studied further with actual patient samples and be taken into consideration when analyzing clinical outcomes according to IMN irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fluid dynamic aspects of cardiovascular behavior during low-frequency whole-body vibration

The behavior of the cardiovascular system during low frequency whole-body vibration, such as encountered by astronauts during launch and reentry, is examined from a fluid mechanical viewpoint. The vibration characteristics of typical manned spacecraft and other vibration environments are discussed, and existing results from in vivo studies of the hemodynamic aspects of this problem are reviewed. Recent theoretical solutions to related fluid mechanical problems are then used in the interpretation of these results and in discussing areas of future work. The results are included of studies of the effects of vibration on the work done by the heart and on pulsatile flow in blood vessels. It is shown that important changes in pulse velocity, the instantaneous velocity profile, mass flow rate, and wall shear stress may occur in a pulsatile flow due to the presence of vibration. The significance of this in terms of changes in peripheral vascular resistance and possible damage to the endothelium of blood vessels is discussed.

Nerem, R. M.↗

Damping seal verification setup

The heart of the Space Shuttle Main Engine (SSME) is a set of turbopumps that propel cryogenic fluids at very high pressures and flow rates, at rotor speeds up to 37,000 rpm. Bushing seals that cause the flow in the fluid film to become turbulent, by means of a multiplicity of pockets, were shown theoretically not only to inhibit subsynchronous whirl, but to reduce leakage as well. However, experimental data that relate these two desirable characteristics to such parameters as pocket depth, Reynolds number (based on clearance and axial flow rate), and rotating speed are limited. To obtain the required data, NASA's Marshall Space Flight Center (MSFC) commissioned Wyle Laboratories to design, build and operate a test rig in which the damping efficacy and leakage reduction of typical candidate seals are to be evaluated.

Cappel, K. L.↗

Automatic Blood Pressure Measurements During Exercise

Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.

Weaver, Charles S.↗

Impaired fatty acid oxidation as a cause for lipotoxicity in cardiomyocytes

A major cause for diabetic cardiomyopathy is excess lipid accumulation. To elucidate mechanisms of lipotoxicity mediated diabetic heart disease we need to further our understanding of how lipid metabolism is altered in the diabetic heart. Here we investigated the role of lipid clearance by oxidation as a regulator of lipid-mediated toxicity (lipotoxicity). We evaluated the effect of pre-treating rat neonatal cardiomyocytes (NCMs) with either oleate (mono-unsaturated fatty acid) or palmitate (saturated fatty acid) on fatty acid oxidation (FAO) by measuring {sup 14}C–CO{sub 2} production. We evaluated carnitine palmitoyltransferase (Cpt1b) expression by western blotting and mitochondrial membrane potential by quantitative and qualitative fluorescence analyses using the JC-1 dye. We inhibited the Cpt1b pharmacologically using etomoxir and genetically by knocking down its expression using LentiVector mediated transduction of siRNAs targeting the Cpt1b gene. We found that palmitate had a slower clearance rate from NCMs than oleate, and this was associated with a significant decrease in FAO. This impairment in FAO was not the result of either loss of Cpt1b protein or mitochondrial integrity. Enhancing FAO with either oleate or carnitine was associated with a significant attenuation of palmitate mediated lipotoxicity. In contrast impairing FAO in oleate treated NCMs caused lipotoxicity. Here we demonstrate that a major difference between non-toxic unsaturated fatty acids and toxic saturated fatty acids is there ability to stimulate or inhibit fatty acid oxidation, respectively. This has important implications for diabetic cardiomyopathy since diabetic hearts consistently exhibit elevated lipid accumulation. - Highlights: • Palmitate had a slower clearance rate from NCMs than oleate. • Palmitate caused a significant decrease in fatty acid oxidation in cardiomyocytes. • Impaired FAO was not due to loss of Cpt1b protein or mitochondrial integrity. • Enhancing FAO attenuated palmitate mediated lipotoxicity. • Impairing FAO caused lipotoxicity by non-toxic oleate.

60 APPLIED LIFE SCIENCES↗

SU-E-T-165: Characterization of Dose Distributions in High-Dose-Rate Surface Brachytherapy

Purpose: To characterize dose distributions in high-dose-rate(HDR) surface brachytherapy using an Ir-125 source for different geometries, field sizes and topology of the clinical targets(CT). To investigate the depth doses at the central axis(CAX), edges of the treatment fields(E), and lateral dose distributions(L) present when using flap applicators in skin cancer treatments. Methods: When malignancies diagnosed on the skin are treated, various geometries of the CT require proper adaptation of the flap or custom-made applicators to the treatment site. Consequently, the dose at the depth on CAX and field edges changes with variation of the curvatures and size of the applicators. To assess the dose distributions, we created a total of 10 treatment plans(TP) for 10×10 and 20×20 field sizes(FS) with a step size of 1cm. The geometry of the applicators was: planar(PA), curved to 30(CA30) and 60(CA60) degrees with respect to the CAX, half-cylinder(HC), and cylindrical shape(CS). One additional TP was created in which the applicators were positioned to form a dome shape(DS) with a diameter of 16cm. This TP was used to emulate treatment of the average sized scalp. All TPs were optimized to deliver a prescription dose at 8mm equidistantly from the planes containing the dwell positions. This optimization is equivalent to the clinical arrangement since the SSD for the flap applicators is 5mm and the prescription depth is 3mm in the majority of clinical cases. Results: The depths (in mm) of the isodose lines were: FS(10×10):PA[90%(9.1CAX,8.0E,7.6L),50%(28.3CAX,20E,17.3L), 25%(51.1CAX,40E,27L)],CA30[90%(10.3CAX,8.2E,7.9L),50%(32.1CAX, 16.2E,15.8L),25%(61.3CAX,36.7E,31.8L)],CA60[90%(12.2CAX,6.1E,6.3L ),50%(47CAX,14E,16.6L),25%(70.8CAX,31.9E,35.4L)],HC[90%(11.1CA X,6.3E,7.3L),50%(38.3CAX,14.6E,16.1L),25%(66.2CAX,33.8E,34.2L)];FS (20×20):PA[90%(11.1CAX,9.0E,7.0L),50%(34.4CAX,21.9E,15.3L),25%(7 0.4CAX,50.9E,34.8L)],CA30[90%(10.9CAX,7.5E,7.1L),50%(38.8CAX,16. 7E,15.4L),25%(80.7CAX,39.9E,35.7L)],HC[90%(11.1CAX,10.9E,10.6L),5 0%(34.4CAX,38.8E,47.2L),25%(70.4CAX,80.7E,96.6L);DS[90%(12.1CA X,8.5E,6.8L),50%(60.6CAX,17.7E,15.8L),25%(109.6CAX,40.3E,34.3L)]. Conclusion: These results can be used for the approximate calculation and quick assessment of the radiation dose to the organs-at-risk at depth (heart,brain,thyroid, optical nerve) or at the surface distance from the CT (breast,eyes, gonads), and only the geometry of the CT needs to be measured. Understanding of the dose distributions in HDR surface brachytherapy may improve clinical decision making process.

60 APPLIED LIFE SCIENCES↗

Voice and video transmission using XTP and FDDI

The use of Xpress Transfer Protocol (XTP) and Fiber Distributed Data Interface (FDDI) provides a high speed and high performance network solution to multimedia transmission that requires high bandwidth. FDDI is an ANSI and ISO standard for a MAC and physical layer protocol that provides a signaling rate of 100 Mbits/sec and fault tolerance. XTP is a transport and network layer protocol designed for high performance and efficiency and is the heart of the SAFENET Lightweight Suite for systems that require performance or realtime communications. The testbed consists of several commercially available Intel based i486 PC's containing off-the-shelf FDDI cards, audio analog-digital converter cards, video interface cards, and XTP software. Unicast, multicast, and duplex audio transmission experiments have been performed using XTP software. Unicast and multicast video transmission is in progress. Several potential commercial applications are described.

Drummond, John↗

Prone Breast Intensity Modulated Radiation Therapy: 5-Year Results

Purpose: To report the 5-year results of a technique of prone breast radiation therapy delivered by a regimen of accelerated intensity modulated radiation therapy with a concurrent boost to the tumor bed. Methods and Materials: Between 2003 and 2006, 404 patients with stage I-II breast cancer were prospectively enrolled into 2 consecutive protocols, institutional trials 03-30 and 05-181, that used the same regimen of 40.5 Gy/15 fractions delivered to the index breast over 3 weeks, with a concomitant daily boost to the tumor bed of 0.5 Gy (total dose 48 Gy). All patients were treated after segmental mastectomy and had negative margins and nodal assessment. Patients were set up prone: only if lung or heart volumes were in the field was a supine setup attempted and chosen if found to better spare these organs. Results: Ninety-two percent of patients were treated prone, 8% supine. Seventy-two percent had stage I, 28% stage II invasive breast cancer. In-field lung volume ranged from 0 to 228.27 cm{sup 3}, mean 19.65 cm{sup 3}. In-field heart volume for left breast cancer patients ranged from 0 to 21.24 cm{sup 3}, mean 1.59 cm{sup 3}. There was no heart in the field for right breast cancer patients. At a median follow-up of 5 years, the 5-year cumulative incidence of isolated ipsilateral breast tumor recurrence was 0.82% (95% confidence interval [CI] 0.65%-1.04%). The 5-year cumulative incidence of regional recurrence was 0.53% (95% CI 0.41%-0.69%), and the 5-year overall cumulative death rate was 1.28% (95% CI 0.48%-3.38%). Eighty-two percent (95% CI 77%-85%) of patients judged their final cosmetic result as excellent/good. Conclusions: Prone accelerated intensity modulated radiation therapy with a concomitant boost results in excellent local control and optimal sparing of heart and lung, with good cosmesis. Radiation Therapy Oncology Group protocol 1005, a phase 3, multi-institutional, randomized trial is ongoing and is evaluating the equivalence of a similar dose and fractionation approach to standard 6-week radiation therapy with a sequential boost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New approaches to virtual environment surgery

This research focused on two main problems: 1) low cost, high fidelity stereoscopic imaging of complex tissues and organs; and 2) virtual cutting of tissue. A further objective was to develop these images and virtual tissue cutting methods for use in a telemedicine project that would connect remote sites using the Next Generation Internet. For goal one we used a CT scan of a human heart, a desktop PC with an OpenGL graphics accelerator card, and LCD stereoscopic glasses. Use of multiresolution meshes ranging from approximately 1,000,000 to 20,000 polygons speeded interactive rendering rates enormously while retaining general topography of the dataset. For goal two, we used a CT scan of an infant skull with premature closure of the right coronal suture, a Silicon Graphics Onyx workstation, a Fakespace Immersive WorkBench and CrystalEyes LCD glasses. The high fidelity mesh of the skull was reduced from one million to 50,000 polygons. The cut path was automatically calculated as the shortest distance along the mesh between a small number of hand selected vertices. The region outlined by the cut path was then separated from the skull and translated/rotated to assume a new position. The results indicate that widespread high fidelity imaging in virtual environment is possible using ordinary PC capabilities if appropriate mesh reduction methods are employed. The software cutting tool is applicable to heart and other organs for surgery planning, for training surgeons in a virtual environment, and for telemedicine purposes.

NASA Discipline Neuroscience↗

Secondary Prevention with Antithrombotic Therapies in Stable Ischemic Heart Disease Patients: a Review

Purpose of Review: Stable and unstable ischemic heart disease are a growing component in all facets of healthcare, including ER visits, hospitalizations, and financial costs. With the changing emphasis of healthcare shifting towards the outpatient setting, the onus is on clinicians to appropriately manage such patients to avoid adverse effects and complications. Antithrombotic medications, including aspirin, P2Y{sub 12} inhibitors, and rivaroxaban, are currently prescribed or have potential roles in the management of secondary cardiovascular prevention in ischemic heart disease patients. While the majority of studies and findings involve aspirin and clopidogrel, newer oral anticoagulation drugs are arriving, prompting new research to assess their impact on preventing mortality, myocardial infarction, and stroke in such patients. Recent Findings: Aspirin has a well-established history of safety and efficacy in management of secondary cardiovascular protection in ischemic heart disease patients. A dual-antiplatelet regimen, most commonly including aspirin plus clopidogrel, has been documented to be effective as well in achieving the same goals. Newer agents, such as rivaroxaban, are being analyzed to see if there is scope to include these agents for secondary prevention. One recent study, the COMPASS trial, revealed the major concern of these newer medications: while better cardiovascular outcomes were achieved in subjects on aspirin plus rivaroxaban, this was accomplished in the setting of a higher rate of major bleeding events. Summary: In conclusion, the evidence thus far has not been significant enough for the American College of Cardiology to recommend the incorporation of oral anticoagulants in the management of stable ischemic heart disease patients, in contrast to aspirin and clopidogrel. As the antithrombotic and antiischemic properties of these newer agents seem evident, so does their potential for increase in risk of bleeding events. Doctors have to individually tailor antithrombotic medication decisions based on the patient’s risk-benefit profile.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of a Highly Performing Conformal Electron Therapy Technique for Chest Wall Irradiation After Mastectomy

Purpose: To evaluate locoregional control and survival after mastectomy, as well as toxicity, in patients irradiated by a previously described postmastectomy highly conformal electron beam radiation therapy technique (PMERT). Methods and Materials: We included all women irradiated by postmastectomy electron beam radiation therapy for nonmetastatic breast cancer between 2007 and 2011 in our department. Acute and late toxicities were retrospectively assessed using Common Terminology Criteria for Adverse Events version 3.0 criteria. Results: Among the 796 women included, 10.1% were triple-negative, 18.8% HER2-positive, and 24.6% received neoadjuvant chemotherapy (CT). Multifocal lesions were observed in 51.3% of women, and 64.6% had at least 1 involved lymph node (LN). Internal mammary chain, supraclavicular, infraclavicular, and axillary LNs were treated in 85.6%, 88.3%, 77.9%, and 14.9% of cases, respectively. With a median follow-up of 64 months (range, 6-102 months), 5-year locoregional recurrence–free survival and overall survival were 90% (95% confidence interval 88.1%-92.4%) and 90.9% (95% confidence interval 88.9%-93%), respectively. Early skin toxicity was scored as grade 1 in 58.5% of patients, grade 2 in 35.9%, and grade 3 in 4.5%. Concomitant CT was associated with increased grade 3 toxicity (P<.001). At long-term follow-up, 29.8% of patients presented temporary or permanent hyperpigmentation or telangiectasia or fibrosis (grade 1: 23.6%; grade 2: 5.2%; grade 3: 1%), with higher rates among smokers (P=.06); 274 patients (34.4%) underwent breast reconstruction. Only 24 patients (3%) had early esophagitis of grade 1. Only 3 patients developed ischemic heart disease: all had been treated by anthracycline-based CT with or without trastuzumab, all had been irradiated to the left chest wall and LN, and all presented numerous cardiovascular risk factors (2-4 factors). Conclusions: This study demonstrated the good efficacy of this technique in terms of locoregional control and survival, and good short-term and long-term safety. Longer follow-up is required to analyze chronic cardiac events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Light on Dark Matter

Under this proposal, we have been undertaking a calibration of rate of change of the expansion rate of the Universe as a function of cosmic look-back time using the high-precision standard candles, Type Ia supernovae, as observed in their rest-frame near-infrared wavelengths. The apparent acceleration of the Universe, as discovered earlier using these same types of supernovae, was both unanticipated and extremely profound in its implications. Not only does the acceleration mean that the Universe is unbound, but it also implies the existence of a new constituent of the Universe (so-called 'dark energy') that is many orders of magnitude stronger than what physicists can easily accommodate in their standard theories of particle physics. A result with such wide-ranging and important implications must be checked, and all sources of systematic error and uncertainty must be evaluated and accounted for. At increasingly higher redshifts the objects being observed are seen at earlier cosmic times and the radiation that reaches Earth is shifted to longer and longer wavelengths. What leaves a supernova event at one time in the past as an optical photon is downgraded by cosmic expansion into a red or infrared photon by the time it is detected here. Optical images of distant supernovae seen now, began their lives as ultraviolet photons. The ultraviolet properties of nearby supernovae are not well understood, so comparing supernova across time and space becomes complicated and uncertain. Moreover it is well known that the systematic effects of interstellar dust are larger and more variable from place to place in the ultraviolet than they are at longer wavelengths. To mitigate both the uncertainty of the ultraviolet calibration and the certainty of variable dust extinction along the line of sight, the Carnegie Supernova Program (CSP) has been observing the distant supernovae at groundbased infrared wavelengths that more closely match restframe (emitted) optical wavelengths at the supernova event itself. Not only does this allow us to compare local (calibrating) supernovae with distant supernovae without the uncertainty of shifting between uncertain physical regimes, but it also actively reduces both the impact and the uncertainty of interstellar dust on the apparent magnitudes of the tagert supernovae and their calibrators. Infrared radiation penetrates dust and gas much more efficiently than optical and ultraviolet photons. This has been possible because Carnegie operates very large-aperture telescopes at the Las Campanas Observatory in Chile, equipped with state-of-the-art, wide-field near-infrared detectors capable of detecting and measuring distant supernovae (discovered by collaborating surveys) early in their evolution. With support from the DOE through this grant the Carnegie Supernova Project has observed 70 Type Ia supernovae from Chile obtaining near-infrared light curves which, when combined with the discovery images provide high-quality data on the rest-frame, near-infrared magnitudes of these supernovae at the time of maximum light. The peak luminosity of Type Ia supernovae can then be used to estimate their distances (once corrected for decline rate and residual reddening effects). Those distances when compared to their expansion velocities give us the systematic departures from pure Hubble expansion that lie at the heart of the detection of dark energy in the Universe. A paper summarizing the techniques and methods used by the CSP in measuring high-redshift supernovae is in the final stages of circulating amongst the team members. We expect to submit it to the Astrophysical Journal before the end of 2008. Half of the data on the full sample observed supernovae has been fully reduced for this paper. We already have a new measurement of the dark energy contribution to cosmic acceleration. We find a value of w = -1.05 {+-} 0.08 (statistical) {+-} 0.08 (systematic). This value is consistent with, but completely independent of and has a smaller systematic uncertainty than, other studies to date.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Myosin dilated cardiomyopathy mutation S532P disrupts actomyosin interactions, leading to altered muscle kinetics, reduced locomotion, and cardiac dilation in Drosophila

Dilated cardiomyopathy (DCM), a life-threatening disease characterized by pathological heart enlargement, can be caused by myosin mutations that reduce contractile function. To better define the mechanistic basis of this disease, we employed the powerful genetic and integrative approaches available in Drosophila melanogaster. To this end, we generated and analyzed the first fly model of human myosin–induced DCM. The model reproduces the S532P human β-cardiac myosin heavy chain DCM mutation, which is located within an actin-binding region of the motor domain. In concordance with the mutation’s location at the actomyosin interface, steady-state ATPase and muscle mechanics experiments revealed that the S532P mutation reduces the rates of actin-dependent ATPase activity and actin binding and increases the rate of actin detachment. The depressed function of this myosin form reduces the number of cross-bridges during active wing beating, the power output of indirect flight muscles, and flight ability. Further, S532P mutant hearts exhibit cardiac dilation that is mutant gene dose–dependent. Our study shows that Drosophila can faithfully model various aspects of human DCM phenotypes and suggests that impaired actomyosin interactions in S532P myosin induce contractile deficits that trigger the disease.

59 BASIC BIOLOGICAL SCIENCES↗

Halofuginone alleviates acute viral myocarditis in suckling BALB/c mice by inhibiting TGF-β1

Viral myocarditis (VMC) is an inflammation of heart muscle in infants and young adolescents. This study explored the function of halofuginone (HF) in Coxsackievirus B3 (CVB3) -treated suckling mice. HF-treated animal exhibited higher survival rate, lower heart/body weight, and more decreased blood sugar concentration than CVB3 group. HF also reduced the expressions of interleukin(IL)-17 and IL-23 and the numbers of Th17 cells. Moreover, HF downregulated pro-inflammatory cytokine levels and increased anti-inflammatory cytokine levels. The expressions of transforming growth factor(TGF-β1) and nuclear factor kappa-light-chain-enhancer of activated B (NF-κB) p65/ tumor necrosis factor-α (TNF-α) proteins were decreased by HF as well. Finally, the overexpression of TGF-β1 counteracted the protection effect of HF in CVB3-treated suckling mice. In summary, our study suggests HF increases the survival of CVB3 suckling mice, reduces the Th17 cells and pro-inflammatory cytokine levels, and may through downregulation of the TGF-β1-mediated expression of NF-κB p65/TNF-α pathway proteins. These results offer a potential therapeutic strategy for the treatment of VMC. - Highlights: • Halofuginone (HF) increases the survival of suckling BALB/c mice infected with acute CVB3. • HF reduces the expression of Th17 cell markers (IL-17 and IL-23) and the number of CD4{sup +} IL17{sup +} cells. • Pro-inflammatory cytokines levels associated with myocarditis were reduced by HF in CVB3-treated suckling mice. • HF alleviates VMC via inhibition of TGF-β1-mediated NF-κB p65/TNF-α pathway.

60 APPLIED LIFE SCIENCES↗