Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Retroreflection Focusing Schlieren System

A retroreflective type focusing schlieren system which permits the light source to be positioned on the optic side of the system is introduced. The system includes an extended light source, as opposed to a point source, located adjacent to a beam splitter which projects light through the flow field onto a reflecting grating in the form of a grid which generates sheets of light that are directed back through the flow field and the beam splitter onto a primary lens behind which is located a cut-off grid having a grid pattern which corresponds to the grid pattern of the reflecting grating. The cut-off grid is adjustably positioned behind the primary lens and an image plane for imaging the turbulence is adjustably located behind the cut-off grid.

Heineck, James T.↗

Automatic Data Distribution for CFD Applications on Structured Grids

Development of HPF versions of NPB and ARC3D showed that HPF has potential to be a high level language for parallelization of CFD applications. The use of HPF requires an intimate knowledge of the applications and a detailed analysis of data affinity, data movement and data granularity. Since HPF hides data movement from the user even with this knowledge it is easy to overlook pieces of the code causing low performance of the application. In order to simplify and accelerate the task of developing HPF versions of existing CFD applications we have designed and partially implemented ADAPT (Automatic Data Distribution and Placement Tool). The ADAPT analyzes a CFD application working on a single structured grid and generates HPF TEMPLATE, (RE)DISTRIBUTION, ALIGNMENT and INDEPENDENT directives. The directives can be generated on the nest level, subroutine level, application level or inter application level. ADAPT is designed to annotate existing CFD FORTRAN application performing computations on single or multiple grids. On each grid the application can considered as a sequence of operators each applied to a set of variables defined in a particular grid domain. The operators can be classified as implicit, having data dependences, and explicit, without data dependences. In order to parallelize an explicit operator it is sufficient to create a template for the domain of the operator, align arrays used in the operator with the template, distribute the template, and declare the loops over the distributed dimensions as INDEPENDENT. In order to parallelize an implicit operator, the distribution of the operator's domain should be consistent with the operator's dependences. Any dependence between sections distributed on different processors would preclude parallelization if compiler does not have an ability to pipeline computations. If a data distribution is "orthogonal" to the dependences of an implicit operator then the loop which implements the operator can be declared as INDEPENDENT.

Frumkin, Michael↗

Development of a Flexible Framework of Common Hypersonic Navier-Strokes Meshes for the Space Shuttle Orbiter

A flexible framework for the development of block structured volume grids for hypersonic Navier-Stokes flow simulations was developed for analysis of the Shuttle Orbiter Columbia. The development of the flexible framework, resulted in an ability to quickly generate meshes to directly correlate solutions contributed by participating groups on a common surface mesh, providing confidence for the extension of the envelope of solutions and damage scenarios. The framework draws on the experience of NASA Langely and NASA Ames Research Centers in structured grid generation, and consists of a grid generation process that is implemented through a division of responsibilities. The nominal division of labor consisted of NASA Johnson Space Center coordinating the damage scenarios to be analyzed by the Aerothermodynamics Columbia Accident Investigation (CAI) team, Ames developing the surface grids that described the computational volume about the orbiter, and Langely improving grid quality of Ames generated data and constructing the final volume grids. Distributing the work among the participants in the Aerothermodynamic CIA team resulted in significantly less time required to construct complete meshes than possible by any individual participant. The approach demonstrated that the One-NASA grid generation team could sustain the demand for new meshes to explore new damage scenarios within a aggressive timeline.

Alter, Stephen J.↗

Flow solution on a dual-block grid around an airplane

The compressible flow around a complex fighter-aircraft configuration (fuselage, cranked delta wing, canard, and inlet) is simulated numerically using a novel grid scheme and a finite-volume Euler solver. The patched dual-block grid is generated by an algebraic procedure based on transfinite interpolation, and the explicit Runge-Kutta time-stepping Euler solver is implemented with a high degree of vectorization on a Cyber 205 processor. Results are presented in extensive graphs and diagrams and characterized in detail. The concentration of grid points near the wing apex in the present scheme is shown to facilitate capture of the vortex generated by the leading edge at high angles of attack and modeling of its interaction with the canard wake.

Eriksson, Lars-Erik↗

Numerical investigations in three-dimensional internal flows

In the present reporting period, the 3D version of the OVERFLOW code was used to solve the flow within the internal portion of the supersonic inlet. The internal portion of this inlet is bounded by an inflow plane containing the leading edge of the sidewalls, the sidewalls, the ramp and cowl surfaces and an outflow plane just downstream of the minimum geometric area of the inlet. Boundary layer bleed was used in the two-dimensional calculations discussed in the previous progress report and that same bleed was applied in the present study. For reference, this bleed corresponds to locations designated as R2 and R3 in the Mach 5 inlet model test. Using the GRIDGEN code, a three dimensional grid was generated that accounted for the viscous effects expected to occur on the sidewall, as well as those known to occur on the ramp and cowl surfaces. The internal flow grid size was 141 streamwise by 101 cross stream by 71 in the lateral direction between sidewalls. Since the flow entering the inlet was not symmetrical, the inlet was solved from sidewall to sidewall (without using a symmetry plane). In addition to the short sidewalls proposed in the Langley geometry database, a set of shorter sidewalls was also investigated in the present study and was shown to have beneficial effects with respect to the flow distortion exiting the supersonic inlet. In addition to these calculations, additional 3D solutions using the OVERFLOW code were obtained for the flow downstream of the throat of the supersonic inlet, including a terminal shock wave system produced by a backpressured subsonic diffuser.

Rose, William C.↗

Dynamic Interaction of Grid-Forming and Grid-Following Inverters with Synchronous Generators in Hybrid Power Plants

As the integration of renewable energy resources such as wind and solar generation continues to grow, the use of hybrid power plants with both synchronous machines and power electronic inverters operating in parallel becomes more common. This paper studies the impact on small-signal stability for these pairs of devices, first as an isolated two-device system and then as part of a 9-bus test system. Each operational scenario was studied with both a grid-following inverter and a grid-forming inverter. In each scenario, the state variables associated with the synchronous generator's excitation system were found to be responsible for the inception of instability. These results underscore the importance of accurate modeling of excitation systems when modeling power systems with hybrid power plants.

hybrid power plant↗

Aerodynamic shape optimization of a HSCT type configuration with improved surface definition

Two distinct parametrization procedures of generating free-form surfaces to represent aerospace vehicles are presented. The first procedure is the representation using spline functions such as nonuniform rational b-splines (NURBS) and the second is a novel (geometrical) parametrization using solutions to a suitably chosen partial differential equation. The main idea is to develop a surface which is more versatile and can be used in an optimization process. Unstructured volume grid is generated by an advancing front algorithm and solutions obtained using an Euler solver. Grid sensitivity with respect to surface design parameters and aerodynamic sensitivity coefficients based on potential flow is obtained using an automatic differentiator precompiler software tool. Aerodynamic shape optimization of a complete aircraft with twenty four design variables is performed. High speed civil transport aircraft (HSCT) configurations are targeted to demonstrate the process.

Thomas, Almuttil M.↗

SU-E-P-30: Clinical Applications of Spatially Fractionated Radiation Therapy (GRID) Using Helical Tomotherapy

Purpose: To present the first clinical applications of Helical Tomotherapy-based spatially fractionated radiotherapy (HT-GRID) for deep seated tumors and associated dosimetric study. Methods: Ten previously treated GRID patients were selected (5 HT-GRID and 5 LINAC-GRID using a commercially available GRID block). Each case was re-planned either in HT-GRID or LINAC-GRID for a total of 10 plans for both techniques using same prescribed dose of 20 Gy to maximum point dose of GRID GTV. For TOMO-GRID, a programmable virtual TOMOGRID template mimicking a GRID pattern was generated. Dosimetric parameters compared included: GRID GTV mean dose (Dmean) and equivalent uniform dose (EUD), GRID GTV dose inhomogeneity (Ratio(valley/peak)), normal tissue Dmean and EUD, and other organs-at-risk(OARs) doses. Results: The median tumor volume was 634 cc, ranging from 182 to 4646 cc. Median distance from skin to the deepest part of tumor was 22cm, ranging from 8.9 to 38cm. The median GRID GTV Dmean and EUD was 10.65Gy (9.8–12.5Gy) and 7.62Gy (4.31–11.06Gy) for HT-GRID and was 6.73Gy (4.44–8.44Gy) and 3.95Gy (0.14–4.2Gy) for LINAC-GRID. The median Ratio(valley/peak) was 0.144(0.05–0.29) for HT-GRID and was 0.055(0.0001–0.14) for LINAC-GRID. For normal tissue in HT-GRID, the median Dmean and EUD was 1.24Gy (0.34–2.54Gy) and 5.45 Gy(3.45–6.89Gy) and was 0.61 Gy(0.11–1.52Gy) and 6Gy(4.45–6.82Gy) for LINAC-GRID. The OAR doses were comparable between the HT-GRID and LINAC-GRID. However, in some cases it was not possible to avoid a critical structure in LINAC-GRID; while HT-GRID can spare more tissue doses for certain critical structures. Conclusion: HT-GRID delivers higher GRID GTV Dmean, EUD and Ratio(valley/peak) compared to LINAC-GRID. HT-GRID delivers higher Dmean and lower EUD for normal tissue compared to LINAC-GRID. TOMOGRID template can be highly patient-specific and allows adjustment of the GRID pattern to different tumor sizes and shapes when they are deeply-seated and cannot be safely treated with LINAC-GRID.

60 APPLIED LIFE SCIENCES↗

A Comparison of Fuel Choice for Backup Generators

This poster discusses the costs and benefits of backup generator configurations. We analyze the relative costs and benefits - in terms of economics and reliability - of natural gas versus diesel as fuels for backup systems. We find that, given our assumptions of fuel security for diesel and natural gas, natural gas generators are less likely than diesel generators to fail during a power outage. The differences in likelihoods of failure between natural gas and diesel generators are small for most regions and dependent on several assumptions. This indicates that differences in fuel source security are of second-order concern. We also find that grid-connected generators run for backup as well as additional services have higher reliability due to more frequent operation, and lower net costs than generators used solely for backup. At the same time, emergency-only systems may still be preferred, depending on permitting, noise, and air quality concerns.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development Strategy for Gas Turbines with Firebrick Resistance-Heated Energy Storage to Enable Nuclear-Renewable Grid Integration

The world is transitioning to a low-carbon energy system. Variable electricity and industrial energy demands have been met with storable fossil fuels-systems with low-capital costs and high-operating costs. In contrast, the low-carbon energy sources (nuclear, wind and solar) are characterized by high-capital-costs and low-operating costs. High utilization is required to produce economic energy. The addition of large quantities of wind or solar changes the market. The Massachusetts Institute of Technology (MIT) Future of Solar Energy study examined the solar option and the challenge of moving from an electricity grid dominated by fossil fuel generation to a grid with significant solar capacity. As more solar plants are built, electricity prices at times of high solar output collapse; thus, solar revenue collapses as solar production increases. This limits unsubsidized solar capacity to a relatively small fraction of total electricity production even if there are large decreases in solar capital costs. The same occurs with the large-scale use of wind. This results in increasing number of hours of near-zero wholesale prices for electricity that has been seen in multiple electricity markets in Europe and the United States. This is bad economic news for nuclear, wind and solar for revenue collapse limits the use of low-carbon technologies. It favors lower-capital-cost higher-operating-cost natural gas plants with their capability to cycle up and down quickly. New technologies are required to store or use this electricity at times of low prices to produce electricity at times of high prices. The use of gas-turbines with Firebrick Resistance-Heated Energy Storage (FIRES) is proposed herein to address this challenge as part of a broader strategy to develop nuclear power systems with three goals: (1) compete with natural gas, (2) prosper with subsidized wind and solar and (3) enable a low-cost low-carbon nuclear-renewable energy system.

25 ENERGY STORAGE↗

Heat Storage for Peak Power with Base-Load Rankine-Cycle LWRs nd Brayton-Cycle High-Temperature Reactors

The world is transitioning to a low-carbon energy system. Variable electricity and industrial energy demands have been met with storable fossil fuels-systems with low-capital costs and high-operating costs. In contrast, the low-carbon energy sources (nuclear, wind and solar) are characterized by high-capital-costs and low-operating costs. High utilization is required to produce economic energy. The addition of large quantities of wind or solar changes the market. The Massachusetts Institute of Technology (MIT) Future of Solar Energy study provides an examination of the solar option and the challenge of moving from an electricity grid dominated by fossil fuel generation to a grid with significant solar capacity. As more solar plants are built, electricity prices at times of high solar output collapse; thus, solar revenue collapses as solar production increases. This limits unsubsidized solar capacity to a relatively small fraction of total electricity production even if there are large decreases in solar capital costs. The same occurs with the large-scale use of wind. This results in increasing number of hours of near-zero wholesale prices for electricity that has been seen in multiple electricity markets in Europe and the United States. This is bad economic news for nuclear, wind and solar for revenue collapse limits the use of low-carbon technologies. It favors lower-capital-cost higher-operating- cost natural gas plants with their capability to cycle up and down quickly. New technologies are required to store or use this electricity at times of low prices to produce electricity at times of high prices. We describe two strategies to improve nuclear power economics based on heat storage. Heat storage is less expensive than electricity storage. The reactor operates at full capacity all the time but the electricity to the grid varies with time depending upon electricity prices. Each option allows sending heat to industry.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A three-dimensional adaptive grid method

A three-dimensional solution-adaptive-grid scheme is described which is suitable for complex fluid flows. This method, using tension and torsion spring analogies, was previously developed and successfully applied for two-dimensional flows. In the present work, a collection of three-dimensional flow fields are used to demonstrate the feasibility and versatility of this concept to include an added dimension. Flow fields considered include: (1) supersonic flow past an aerodynamic afterbody with a propulsive jet at incidence to the free stream, (2) supersonic flow past a blunt fin mounted on a solid wall, and (3) supersonic flow over a bump. In addition to generating three-dimensional solution-adapted grids, the method can also be used effectively as an initial grid generator. The utility of the method lies in: (1) optimum distribution of discrete grid points, (2) improvement of accuracy, (3) improved computational efficiency, (4) minimization of data base sizes, and (5) simplified three-dimensional grid generation.

Nakahashi, K.↗

Achieving geometric accuracy in FFT-based micromechanical models using conformal grid

Owing to its efficiency, simplicity and robustness, the FFT-based method has become the standard for computation of mechanical fields in a heterogeneous periodic unit cell. One of the main disadvantages of the FFT-based method is the inaccurate representation of the initial microstructure on a regular grid of voxels, which can be alleviated through the use of distorted initial grids. Here, in this paper, a method for generation of distorted initial grids conforming to the microstructural features (e.g. straight/curved boundaries) is proposed. The method determines the positions of the grid nodes in the initial configuration by solving a system of springs connecting the nodes. Microstructures consisting of layers, Voronoi tessellation and circular/spherical inclusions are considered, and mechanical fields simulated using the FFT-based method. It is found that distorted initial grids, conforming to the microstructural features, lead to more accurate mechanical fields in comparison to the corresponding non-distorted initial grid solution. The effect of initial grid distortion on the convergence of the FFT-based method is analyzed and discussed.

36 MATERIALS SCIENCE↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Renewable and Energy Efficiency Technologies Overview

Renewable energy and energy efficiency technologies are growing rapidly and, with increased penetration, are increasingly impacting how the electricity grid operates. This presentation outlines a number of the technologies and describes the research, development, and deployment the National Renewable Energy Laboratory is partaking on them. It also provides data on the growth of renewable electricity generation technologies over the last decade and how their increasing generation impacts grid operations. It is intended for an audience familiar with energy technologies but who are not experts in either renewable energy or the electricity grid such as attendees at the virtual course nuclear-renewable integrated systems.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Use of Wind Turbine Kinetic Energy to Supply Transmission Level Services

This paper discusses the broad use of rotational kinetic energy stored in wind turbine rotors to supply services to the electrical power grid. The grid services are discussed in terms of zero-net-energy, which do not require a reduction in power output via pitch control (spill), but neither do they preclude doing so. The services discussed include zero-net-energy regulation, transient and small signal stability, and other frequency management services. The delivery of this energy requires a trade-off between the frequency and amplitude of power modulation and is limited, in some cases, by equipment ratings and the unresearched long-term mechanical effects on the turbine. As wind displaces synchronous generation, the grid's inertial storage is being reduced, but the amount of accessible kinetic energy in a wind turbine at rated speed is approximately 6 times greater than that of a generator with only a 0.12% loss in efficiency and 75 times greater at 10% loss. The potential flexibility of the wind's kinetic storage is also high. However, the true cost of providing grid services using wind turbines, which includes a potential increase in operations and maintenance costs, have not been compared to the value of the services themselves.

17 WIND ENERGY↗