Gamma-ray imaging assay of cells 3-5 of the east cell line in the 235-F plutonium fuel form facility

In August and September, 2016, scientists from the Savannah River National Laboratory (SRNL) took a series of gamma-ray imaging measurements through the cell windows in front of Cells 3-5 on the east line of the Plutonium Fuel Form (PuFF) Facility using an electrically cooled, high-purity germanium detector. A Germanium Gamma Ray Imager (GeGI) was utilized since it allowed for the location from which the radiation was being emitted to be identified by incoming gamma-ray energy. This measurement technique provided a tool which allowed for the relative concentration of Pu-238 to be mapped throughout each cell. The mapping and new assay data were then used to update the model used in an assay discussed in a 2014 report (SRNL-STI-2014-00629) and to calculate a more accurate value for the holdup in each of the cells [1]. Note that the mapping and new assay data did not replace the previous assay data in the model. Rather, the mapping and new assay data provided additional details on source distribution, which supplemented the previous assay data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Evaluation of Electrically Cooled Detectors for use with the LLNL Whole Body Scanning Bed System

Lawrence Livermore National Laboratory (LLNL) is replacing a liquid nitrogen cooled high purity germanium detection system with an electrically cooled high purity germanium system for its scanning bed whole body counting system. The new detectors offer a safer environment for workers while they are measured inside the shielded facility at LLNL and provide highly stable cooling of the detectors. The positioning of the electrically cooled detectors is slightly different from the liquid nitrogen cooled detectors due to the electrical cooling units attached to the detectors. The technical evaluations and results described in this document demonstrate that the new electrically cooled system provides results that comply with internal dosimetry requirements

61 RADIATION PROTECTION AND DOSIMETRY↗

Fabrication of Position Controlled Si/SiGe Quantum Dots for Integrated Optical Sources and Beyond

Recent work done at the University of Florida (UF) revealed a tremendously enhanced germanium diffusion process along silicon/silicon dioxide interfaces during oxidizing anneals, allowing for the controlled formation of Si quantum wires. This project seeks to further explore this unusual germanium behavior during oxidation for the purpose of forming unique and useful nano and quantum structures. Specifically, we propose here to demonstrate for the first time that this phenomenon can be extended to realize OD Si nanostructures through the oxidation of axially heterostructured vertical Si/SiGe pillars. Such structures could be of great interest for applications in integrated optoelectronics, beyond Moore's Law computing, and quantum computing.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Sol-Gel Based Nanoparticles for 3D Printing of Optical Glass

Additive manufacturing also known as 3D printing provides an innovative way to produce gradient index (GRIN) lens and other high-performance optics. Novel inks for direct ink write (DIW) 3D printed optical glass have been reported; however, the refractive index has never surpassed a value of 1.48. Here, we report a ternary formulation of core-shell SiO 2 nanoparticles coated with a TiO 2 shell and GeO 2 nanoparticles that can be used as a feedstock for DIW lenses. Printable titanium-germanium-silica inks were prepared from colloidal sol-gel feed stocks to produce shear-thinning inks for DIW. The inks were dried and sintered following an optimized heat treatment to remove organic material and produce a transparent and void-free monolith. Through this method, we found that these lenses are transparent at dopant concentrations of 7 mol% TiO 2 and 14 mol% GeO 2 . With higher dopant concentrations of germanium and titanium, these lenses subsequently have a refractive index of 1.52. Moreover, these inks share the same viscoelastic properties as previous shear thinning DIW inks, allowing these inks to be 3D printed.

36 MATERIALS SCIENCE↗

Searching for Low-Mass Dark Matter with SuperCDMS Soudan Detectors

SuperCDMS is a direct-detection dark matter (DM) experiment that uses cryogenically cooled germanium and silicon detectors to search for interac- tions between DM particles and detector nuclei, and in this thesis I describe my contributions to the experiment. I start with a brief review of DM and motivate the possibility of its de- tection in underground laboratories with sensitive detectors, and I review the SuperCDMS detector fundamentals. Then I focus on detector develop- ment for the future generation of the experiment, which will deploy an array of detectors at SNOLAB in Sudbury, Canada. Specifically I describe char- acterization of prototype detectors from surface facility testing, and discuss measurements of critical values that determine the detectors’ sensitivity to DM particles, such as the baseline resolution and the phonon collection ef- ficiency. I also describe analysis techniques developed to measure intrinsic detector noise in a high radiation environment such as a surface test facility. In the final chapters I describe a DM search analysis using four months of data from operation of SuperCDMS detectors in the Soudan Mine in northern Minnesota. I discuss how a particular detector operating mode, called CDMSlite, lowers the energy threshold of the detectors in order to improve the sensitivity to low-mass DM particles. I also present new analysis techniques that optimize the sensitivity to low-mass DM particles, including noise discrimination with multivariate classifiers, instrumental background modeling, and a profile likelihood signal and background fitting approach. In this analysis we set an upper limit on the DM-nucleon scattering cross section in germanium that is a factor of 2.5 improvement over the previous CDMSlite result for a DM mass that is five times the proton rest mass.

79 ASTRONOMY AND ASTROPHYSICS↗

Discovering the nature of neutrinos: How nuclear theory will advance this grand endeavor. Final report

Why is there more matter than antimatter in the visible universe? Are neutrinos their own antiparticles? These are some of the most profound questions in science. The detection of a (0vββ) neutrinoless doublebeta decay and the measurement of its half-life is one of the most important experimental endeavors in science because it will answer these questions. Paramount to these measurements are accurate predictions with quantified uncertainties of the 0vββ-decay nuclear transitions, especially for the germanium-76 and xeon-136 nuclei, two candidate materials for building the next generation of DOE funded 0vββ-decay experiments. These predictions will guide the Office of Science’s down selection of experiments as well as aid in determining how much material is needed by these experiments. We studied a specific difficult to assess source of uncertainty that will impact coming microscopic predictions, uncertainty which arises from an incomplete yet systematically improvable model of interactions between nucleons and of nucleons with the other particles involved in decay process, referred to as the theory uncertainty. We employed a surrogate model of the germanium-76 nucleus, and its decay products, just detailed enough to adequately mimic the decaying nucleons need for a reasonable measure of this uncertainty and nothing more, avoiding the immense computational expense required in quantifying uncertainties of the full calculation. We found that microscopic calculations of this process can be expected to achieve relative theory uncertainties around 30%, including an unconstrained contribution that had the potential to spoil microscopic calculations. This results in a nearly order of magnitude on previously estimated uncertainties for this rare decay process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Geranium Photodiodes for Hard Xray Detection

This report summarizes the investigations engaged at UC Davis under subcontract B632083, as related to the LLNL-LDRD Project “High-Speed X-Ray Imager Arrays.” The first section entails work done within the Electrical and Computer Engineering (ECE) Department. The purpose of the work done so far is to understand photodiode design and which parameters are conducive to the design goals, which are: I: Maximize the detector quantum efficiency. The device must have a quantum efficiency of roughly 5% at 80 keV. II: Minimize temporal response. Collection time is limited to 1ns. All charge must be collected in that time. III: Minimize dark current. In this document, various photodiode parameters and designs are explored, and their impact on these goals are tabulated. In addition to these, various instruments that have been constructed for either testing these parameters or helping teammates with their experiments. The second section entails work done with the Materials Science Engineering (MSE) Department. In accordance with the proposed development of the germanium ROIC backside imagers, a critical step in the micromachining of these devices was the removal of the substrate on which the PIN junctions were epitaxially grown. A common technique for the micromachining of silicon wafers is the use of chemical etching alongside an “etch-stop” layer. In this technique, a chemical etchant will remove material until it reaches the etch-stop layer, at which the etch rate will drop significantly. This high selectivity (ratio of etch rates) allows any unevenness in the initial etching to be effectively smoothed away in the event that part of the wafer surface reaches the etch-stop layer sooner than another. An initial literature review found a paper by Divan et al. in which the authors used ion implantation to dope germanium wafers and achieve selectivity on the order of 100, sufficient for a reliable etch-stop.

42 ENGINEERING↗

Designing the Neutron Detector for the NEXUS Test Facility

The SuperCDMS dark matter experiment is commissioning a new test facility at Fermilab, NEXUS, capable of testing a new suite of detectors that promise to push to lower dark matter masses than has previously been achieved. These detectors use silicon and germanium, cooled to tens of mK, to measure small vibrations in the crystal lattice caused by very tiny energy deposits. A core capability of NEXUS test facility is to use a commercial neutron generator, coupled to an array of detectors behind the test facility, to calibrate the nuclear recoil energy scale of these detectors through neutron scattering. The response of silicon and germanium to nuclear recoils below 1 keV energy transfer is largely unknown. For dark matter models which are primarily interacting with the nucleus, calibration of this response will completely determine the dark matter sensitivity of the experiment. In this context, the proper design of the neutron tagging detector to be used in the test facility needs to be found. This work will include simulation of the detector behavior and work towards an optimization of the detector geometry based on measurement resolution and detection rate. In addition, prototype scintillators and photodetectors will be studied as candidate detector elements.

47 OTHER INSTRUMENTATION↗

Toward Trustworthy Detectors Detector Characterization for SuperCDMS SNOLAB Commissioning

SuperCDMS SNOLAB is a next generation direct detection experiment searching for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As commissioning begins, establishing stable, predictable detector response to energy deposits is a prerequisite for future physics analysis. This work studies detector stability and calibration for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium) and det 11 and det 14 (silicon), using Barium-133 calibration data (356 keV gamma ray reference) and low background data (ambient radiation, no external source). The Ba-133 data show no distinct line at the expected energy, and the low background data show a baseline that drifts and oscillates rather than remaining flat, consistently across multiple channels, suggesting a shared, detector wide cause. These observations point to the cryogenic support system as the likely source, since small temperature fluctuations could couple into the temperature sensitive detectors, informing the ongoing commissioning effort.

O'Hanlon, Vika [Skidmore Coll.]↗

Lawrence Livermore National Laboratory?s Book of Minimum Detectable Activity for Direct Measurement of Internally Deposited Radionuclides in Radiation Workers

Lawrence Livermore National Laboratory maintains an in vivo measurement program designed to identify and evaluate the activity of radionuclides deposited in the body. Two types of systems are primarily used for the routine monitoring of radiation workers, the lung counting system and the scanning bed whole body counting system. The lung counting system is comprised of two Canberra ACTII detector sets. Each ACTII set contains two planar germanium detectors with carbon composite end windows optimized to measure low energy photon emitting radionuclides. The ACTII detectors are placed on the upper torso over the lungs for the direct measurement of internally deposited radionuclides in the lungs that emit low energy photons. A correction for the thickness of the chest wall is applied to the efficiency. Because the thickness of the chest wall is a key factor in the measurement of low energy photon emitting radionuclides in the lung, the minimum detectable activity is a function of the chest wall thickness. The scanning bed whole body counting system is comprised of a thin air mattress on top of a carbon fiber bed that slowly scans over four high purity germanium detectors. The scanning system is designed to minimize variations in detected activity due to radionuclide distribution in the body. The scanning bed detection system is typically used for the measurement of internally deposited radionuclides that emit photons above 100 to 200 keV. MDAs have been generated for radionuclides that provide energies above 80 keV since the lowest calibration energy for the system is approximately 86 keV. The following charts and table provide best determination of minimum detectable activity using human subjects as controls for the background contributions. A wide variety of radionuclides are used throughout the laboratory and the following pages represent several of the radionuclides that have been encountered at the Whole Body and Spectroscopy Laboratories within Hazards Control.

61 RADIATION PROTECTION AND DOSIMETRY↗

Recovery Act: "Near-Single-Crystalline Photovoltaic Thin Films on Polycrystalline, Flexible Substrates" (Final Report)

III-V photovoltaics have exhibited efficiencies above 40%, but have found only a limited use because of the high cost of single crystal substrates. At the other end of the spectrum, polycrystalline and amorphous thin film solar cells offer the advantage of low-cost fabrication, but have not yielded high efficiencies. Our program is based on single-crystalline-like thin film photovoltaics on polycrystalline substrates using biaxially-textured templates made by Ion Beam-Assisted Deposition (IBAD). MgO templates made by IBAD on flexible metal substrate have been successfully used for epitaxial growth of germanium films. In spite of a 4.5% lattice mismatch, heteroepitaxial growth of Ge was achieved on CeO 2 that was grown on IBAD MgO template. Room temperature optical bandgap of the Ge films was identified at 0.67 eV indicating minimal residual strain. Refraction index and extinction coefficient values of the Ge films were found to match well with that measured from a reference Ge single crystal. GaAs has been successfully grown epitaxially on Ge on metal substrate by molecular beam epitaxy. RHEED patterns indicate self annihilation of antiphase boundaries and the growth of a single domain GaAs. The GaAs is found to exhibit strong photoluminescence signal and, an existence of a relatively narrow (FWHM~20 meV) band-edge excitons measured in this film indicates a good optoelectronic quality of deposited GaAs. While excellent epitaxial growth has been achieved in GaAs on flexible metal substrates, the defect density of the films as measured by High Resolution X-ray Diffraction and etch pit experiments showed a high value of 5 x 10 8 per cm 2 . Cross sectional transmission electron microscopy of the multilayer architecture showed concentration of threading dislocations near the germanium-ceria interface. The defect density was found decrease as the Ge films were made thicker. The defects appear to originate from the MgO layer presumably because of large lattice mismatches between the various layers. The defect density in GaAs was reduced by a factor of five by adding a step of in-situ deposition of Ge by MBE on the sputtered Ge prior to GaAs growth. We have investigated device design strategies that would support development of high-efficiency devices in presence of dislocation densities of 10 8 cm -2 present in our epitaxial GaAs films. Results from modeling work show that with a proper emitter, base and doping selection, the modeled efficiency of a GaAs cells with dislocation densities of 10 9 and 10 8 cm -2 could be increased from 1% and 7% to 11% and 17% respectively. Under AM0, this single junction GaAs solar cell, has optimized value of emitter and base thickness of around 0.7 and 1.7 microns respectively, to give a maximum efficiency of 24.2%. We have fabricated complete GaAs solar cells using our Ge films on metal substrates. Pattern resolution of few microns with well-defined grid line of 30 microns has been realized on few cm square flexible templates. The ability to grow single-crystalline-like Ge films on flexible, polycrystalline substrates by reel-to-reel tape processing now provides an immense potential to fabricate high quality III-V photovoltaics on flexible, inexpensive substrates.

14 SOLAR ENERGY↗

Recent results from the Majorana Demonstrator

The MAJORANA DEMONSTRATOR is an experiment constructed to search for Neutrinoless double-beta decay in 76Ge and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium detectors totalling 44.1 kg, operating on the 4850’ level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Data acquisition in the commissioning phase began in June 2015, followed by data acquisition with the full detector array in August 2016. The ultralow background and record energy resolution achieved by the MAJORANA DEMONSTRATOR enable a sensitive neutrinoless double-beta decay search, as well as additional searches for physics beyond the Standard Model. I will discuss the design elements that enable these searches, along with our latest results, focusing on the neutrinoless double-beta decay search. I will also discuss the current status and the future plans of the MAJORANA DEMONSTRATOR, as well as the plans for a future tonne-scale 76Ge experiment.

Myslik, Jordan W.↗

Wedge immersed thermistor bolometer measures infrared radiation

Wedge immersed-thermistor bolometer measures infrared radiation in the atmosphere. The thermistor flakes are immersed by optical contact on a wedge-shaped germanium lens whose narrow dimension is clamped between two complementary wedge-shaped germanium blocks bonded with a suitable adhesive.

Dreyfus, M. G.↗

Electron beam recrystallization of amorphous semiconductor materials

Nucleation and growth of crystalline films of silicon, germanium, and cadmium sulfide on substrates of plastic and glass were investigated. Amorphous films of germanium, silicon, and cadmium sulfide on amorphous substrates of glass and plastic were converted to the crystalline condition by electron bombardment.

Evans, J. C., Jr.↗

Influence of gravity-free solidification on microsegregation

Single crystalline germanium has been grown for the first time in space aboard Skylab Mission No. 2. The crystal growth experiment, designed to characterize the influence of gravity-free solidification on microsegregation of a semiconductor material, contained three crystals. One was doped with Ga; the second with Sb; and the third with B. Portions of the germanium crystals were remelted and subsequently resolidified at 5 microns per second under controlled conditions by the gradient freeze technique. Detailed spreading resistance measurements made on the Ga doped Ge crystals indicate that microsegregation in space is reduced by two to five-fold in the bulk and eight-fold near the surface, while macrosegregation in space is reduced by six-fold in the bulk. The effective segregation coefficient for Ga in Ge was analyzed extensively and was found to be larger for space solidification. This has the implication that the solute boundary layer at the growth interface in space is correspondingly thinner. The solidification interface is significantly smoother and is found to be initially convex toward the melt in space. A convective mixing model has been advanced to explain the absence of gravity on convective mixing and solute segregation during solidification.

Yue, J. T.↗

Skylab experiments on semiconductors and alkali halides

The space processing experiments performed during the Skylab missions included one on single crystal growth of germanium selenide and telluride, one on pure and doped germanium crystals, two on pure and doped indium antimonide, one on gallium-indium-antimony systems, and one on a sodium chloride-sodium fluoride eutectic. In each experiment, three ampoules of sample were processed in the multipurpose electric furnace within the Skylab Materials Processing Facility. All were successful in varying degrees and gave important information about crystal growth removed from the effects of earth surface gravity.

Lundquist, C. A.↗

The Identification of Scientific Programs to Utilize the Space Environment

A program to identify and develop ideas for scientific experimentation on the long duration exposure facility (LDEF) was completed. Four research proposals were developed: (1) Ultra pure germanium gamma ray radiation detectors in the space environment, intended to develop and demonstrate an X-ray and gamma-ray spectroscopy system incorporating a temperature cyclable high-purity germanium detector and diode heat pipe cryogenic system for cooling, (2) growth, morphogenesis and metabolism of plant embryos in the zero-gravity environment, to investigate if the space environment induces mutations in the embryogenic cells so that mutants of commercial significance with desirable attributes may be obtained, (3) effect of zero gravity on the growth and pathogenicity of selected zoopathic fungi. It is possible that new kinds of treatment for candidiasis, and tichophytosis could eventuate from the results of the proposed studies, and (4) importance of gravity to survival strategies of small animals. Gravitational effects may be direct or mediate the selection of genetic variants that are preadapted to weightlessness.

Kulacki, F. A.↗

Ge:Ga and Ge:Be photoconductive detectors for far infrared astronomy from a space platform

The paper describes some of the development work on gallium-doped germanium (Ge:Ga) and beryllium-doped germanium (Ge:Be) photoconductive detectors for use in far-infrared astronomical observations from a space platform such as IRAS. The paper is concerned primarily with detector performance and is divided into two major parts. The first presents the operating principles of this type of detector, while the second presents measured performance data under low-background flux conditions. It is shown that high sensitivity can be obtained from Ge:Ga and Ge:Be detectors under low-background and low-temperature conditions of operation. These detectors are useful for astronomical observations in the far-infrared over the wavelength range 30-120 microns. Major conclusions of the research work done so far are mentioned, including that detectors cut from the same crystal show reasonably good reproducibility of operating characteristics.

Bratt, P. R.↗