Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flux Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Dosimetry for the University of Central Florida (UCF3) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the University of Central Florida (UCF)-3 third stage experiment which was conducted in position B8 of the ATR. Three other irradiations included in the scope of work are reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the UCF-3 assemblies at INL prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at 8 fluence monitor locations. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Dosimetry for the Colorado School of Mines (CSM 16-10584) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the Colorado School of Mines (CSM 16-10584) experiment which was conducted in position B5 of the ATR. Three other irradiations included in the scope of work are reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the CSM assemblies at INL prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at 12 fluence monitor locations. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Muon Time-of-Flight studies for cosmic background rejection in the Short Baseline Near Detector

The Short-Baseline Neutrino (SBN) program at Fermilab is a cutting-edge project in experimental neutrino physics. One of its main goals is to systematically investigate the possible existence of eV-scale sterile neutrinos. This phenomenon has been hypothesized to explain some anomalies found in short-range experiments and, if confirmed, would imply a substantial extension of the Standard Model. SBN also offers an important opportunity to deepen the understanding of neutrino-nucleus interactions in the GeV energy range, through the use of Liquid Argon Time Projection Chambers (LArTPC) detectors, a fundamental technology also for the future DUNE experiment. The SBN experimental infrastructure consists of three detectors aligned along the Booster Neutrino Beamline at Fermilab. Among them, the detector located closest to the neutrino source, SBND (Short-Baseline Near Detector), positioned approximately 110 meters from the target, plays a key role in directly characterizing the initial neutrino flux. This allows for a direct comparison with the measurements from the far detector, ICARUS, located about 600 meters from the source, in order to search for potential signs of anomalous neutrino oscillations. My master's thesis focuses on the commissioning and characterization activities of the SBND detector, with particular reference to the Cosmic Ray Tagger (CRT). The CRT is a subsystem for identifying and rejecting events produced by cosmic rays, which constitute the main source of background for surface experiments like SBND. The activity began with the commissioning of the final components of the detector, as well as their validation to verify their correct functioning and signal acquisition. A central part of my work involved studying the veto efficiency of the CRT system, analyzing the rate of cosmic ray-induced events to quantify any loss of neutrino-induced events caused by cosmic background. This allowed for a more precise evaluation of the systematic impact of the CRT on the useful physics sample. A further phase of my analysis involved an in-depth study of the temporal correlation between the CRT signals and those acquired by the LArTPC's internal photodetector system, consisting of photomultiplier tubes and X-ARAPUCA devices. The objective is to explore the possibility of using combined temporal information as an additional criterion for discriminating between cosmic signals and signals genuinely due to neutrino interaction. Preliminary results indicate the presence of characteristic temporal signatures that could be exploited to improve event selection and increase the purity of the neutrino-induced sample. These methodologies will certainly contribute to the optimization of SBND analysis strategies and, more generally, to a better understanding of background mechanisms in next-generation LArTPC experiments.

Corallo, Annalea [Ferrara U.]↗

MiR-125b enhances autophagic flux to improve septic cardiomyopathy via targeting STAT3/HMGB1

We explore the role of miR-125b in septic cardiomyopathy, focusing on miR-125b/STAT3/HMGB1 axis. CLP mouse model and LPS-stimulated primary rat cardiomyocytes (CMs) and H9C2 cell were used as in vivo and in vitro models of septic cardiomyopathy, respectively. qRT-PCR and western blot were performed to measure expression levels of miR-125b, STAT3, HMGB1, and autophagy-related proteins. MTT assay was employed to examine LPS toxicity. Dual luciferase activity assay and CHIP were performed to validate interactions of miR-125b/STAT3 and STAT3/HMGB1 promoter. Immunostaining was used to assess the level of autophagic flux. ROS level was measured by fluorescence assay. Heart functions were examined via intracoronary Doppler ultrasound. miR-125b was diminished while STAT3 and HMGB1 were elevated in the heart tissue following CLP surgery and in LPS-treated H9C2 cells. LPS treatment up-regulated ROS generation and suppressed autophagic flux. Overexpression of miR-125b mimics or knockdown of STAT3 or HMGB1 alleviated LPS-induced hindrance of autophagic flux and ROS production. miR-125b directly targeted STAT3 mRNA and STAT3 bound with HMGB1 promoter. Overexpression of miR-125b mitigated myocardial dysfunction induced by CLP in vivo. Hyperactivation of STAT3/HMGB1 caused by reduced miR-125b contributes to ROS generation and the hindrance of autophagic flux during septic cardiomyopathy, leading to myocardial dysfunction.

60 APPLIED LIFE SCIENCES↗

High Flux Isotope Reactor Neutron Spectrum Shape Estimation From Activation Experiment Data

Here, this article provides a comprehensive review of historical irradiation dosimetry available for different locations within the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). This article includes a summary of the available measured activation target data covering a span of over 15 years and 39 experimental campaigns, including 200 individual sample locations evaluated. Using this broad set of data, we reconstruct historic average neutron spectra shapes for HFIR at various locations, including within the flux trap region, beryllium reflectors, and hydraulic tube (HT) regions, at both the 100- and 85-MW operational power. Our findings indicate that the general axial flux distribution shows a relatively small change in transition from 100- to 85-MW operating power, with differences of -6% to +15% for the thermal energy range and around -16% to +8% for the fast range, indicating a sharper drop-off of the thermal neutron flux away from the axial center. Compared with historical dosimetry estimates of the HFIR flux shape, we generally find a moderately broader axial profile shape for thermal neutrons in the interior target regions for the 100-MW samples evaluated but relatively close agreement for the present 85-MW flux shape for both thermal and fast fluxes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MEASUREMENT OF THE NEUTRON FLUENCE-RATES IN THE ADVANCED TEST REACTOR

The axial neutron fluence-rate distribution at the Advanced Test Reactor (ATR) is determined using a combination of pure nickel and cobalt-aluminium alloy dosimeter wires. Most irradiation programs at ATR need to know the fast neutron fluence-rate surrounding their experiment to correlate post-irradiation examination results with neutron dose. The activated dosimeter wires, which extend beyond the full fuelled region of the reactor core, are highly radioactive following the full cycle in ATR and must therefore be measured in the ATR canal. The system that is employed for these measurements is mechanical scanning mechanism is used to scan the activated wires across the face of a columnated shield and a NaI detector. This detector is not sufficiently calibrated to provide absolute activity measurements, therefore, the count-rate is recorded and normalized to the highest activity for that wire. Then, an approximately 3-mm long portion of the wire is removed from the highest activity region in the wire. The wires are then transferred, and an absolute activity measurement is made using a calibrated ionization chamber. These measurements are combined with corrections for decay, neutron energy spectrum, burnup, dosimeter composition, reactor power fluctuations, and reactor outages to determine the average axial neutron fluence-rate at various locations within ATR during the cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Non-destructive quantification of anaerobic gut fungi and methanogens in co-culture reveals increased fungal growth rate and changes in metabolic flux relative to mono-culture

Abstract Background Quantification of individual species in microbial co-cultures and consortia is critical to understanding and designing communities with prescribed functions. However, it is difficult to physically separate species or measure species-specific attributes in most multi-species systems. Anaerobic gut fungi (AGF) (Neocallimastigomycetes) are native to the rumen of large herbivores, where they exist as minority members among a wealth of prokaryotes. AGF have significant biotechnological potential owing to their diverse repertoire of potent lignocellulose-degrading carbohydrate-active enzymes (CAZymes), which indirectly bolsters activity of other rumen microbes through metabolic exchange. While decades of literature suggest that polysaccharide degradation and AGF growth are accelerated in co-culture with prokaryotes, particularly methanogens, methods have not been available to measure concentrations of individual species in co-culture. New methods to disentangle the contributions of AGF and rumen prokaryotes are sorely needed to calculate AGF growth rates and metabolic fluxes to prove this hypothesis and understand its causality for predictable co-culture design. Results We present a simple, microplate-based method to measure AGF and methanogen concentrations in co-culture based on fluorescence and absorbance spectroscopies. Using samples of < 2% of the co-culture volume, we demonstrate significant increases in AGF growth rate and xylan and glucose degradation rates in co-culture with methanogens relative to mono-culture. Further, we calculate significant differences in AGF metabolic fluxes in co-culture relative to mono-culture, namely increased flux through the energy-generating hydrogenosome organelle. While calculated fluxes highlight uncertainties in AGF primary metabolism that preclude definitive explanations for this shift, our method will enable steady-state fluxomic experiments to probe AGF metabolism in greater detail. Conclusions The method we present to measure AGF and methanogen concentrations enables direct growth measurements and calculation of metabolic fluxes in co-culture. These metrics are critical to develop a quantitative understanding of interwoven rumen metabolism, as well as the impact of co-culture on polysaccharide degradation and metabolite production. The framework presented here can inspire new methods to probe systems beyond AGF and methanogens. Simple modifications to the method will likely extend its utility to co-cultures with more than two organisms or those grown on solid substrates to facilitate the design and deployment of microbial communities for bioproduction and beyond.

59 BASIC BIOLOGICAL SCIENCES↗

Observation of pedestal mode spreading into SOL and broadening of divertor particle flux width on EAST tokamak

Pedestal turbulence spreading into a crape-off layer (SOL) can be used to explain the experimentally observed strong pedestal-SOL coupling and is expected to be important for the broadening of divertor deposition profiles in future devices (Xu et al 2019 Nucl. Fusion 59 126039). In the EAST tokamak, it is found that an electromagnetic (EM) mode in the pedestal region can spread into the SOL and broaden the divertor particle flux width. Multi-channel fluctuation reflectometry is used to measure the density fluctuations at the plasma edge. The EM mode rotates in the electron diamagnetic drift direction in the lab frame with a frequency range of [40–90] kHz, toroidal mode number n= 12–13 and poloidal wavenumber k θ = 0.41 cm −1 . The mode amplitude peaks around the maximum of the pedestal density gradient. As the mode amplitude increases, the reflectometry channel in the SOL can clearly capture the mode. This result suggests that the EM mode is excited in the pedestal gradient region and spreads into the SOL. It is further found that the particle flux deposition profile in the divertor is broadened as the EM mode appears.

Energy↗

New calculations for photosynthesis measurement systems: what’s the impact for physiologists and modelers?

Measurement of carbon dioxide (CO 2 ) and water vapor (H 2 O) exchanged by leaves has been tremendously important for advancing understanding of plant physiology. Typically, photosynthesis measurement systems estimate the concentration of CO 2 and H 2 O in air that has passed over a leaf inside a leaf chamber. Together with additional information such as flow rate, leaf area, and measurement of environmental variables, the calculations of von Caemmerer & Farquhar (1981), hereafter vCF1981, are used to estimate CO 2 and H 2 O fluxes between the leaf and atmosphere. Furthermore, the combination of the vCF1981 calculations and photosynthesis measurement systems has enabled significant advances in the understanding and model representation of leaf-level photosynthesis and respiration.

54 ENVIRONMENTAL SCIENCES↗

Non-contact based measurement of thin film coatings using eddy current measurements

When a time varying magnetic field attempts to penetrate a conductive surface, the surface will respond to that time varying field by the generation of circular currents around the flux lines. This effect is described by Faraday’s law of induction. An eddy current based measurement system attempts to discern the power loss incurred by these circulating currents within the conductive surface. The measurement system described here uses an Agilent E 4980A LCR meter to quantify the reaction of the film to the high frequency magnetic field lines which are forced into the film. The measurement metric is the meter’s interpretation of the power dissipation caused by the measured film. The meter is setup to use the Ls/Rs inductor model, and is run at 1 Mhz to bring the losses within the film as high as possible for sensitivity.

43 PARTICLE ACCELERATORS↗

HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017) (and subsequently titled) Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020) (Final Technical Report)

This is the Final Technical Report for the DoE Measurement Innovation (previously Diagnostic Development) grant DE-SC0006077 titled HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017), and subsequently titled Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020). The grant was funded by the Office of Fusion Energy Sciences (FES) for the period 1 May 2011–17 July 2020. Work performed through the grant has resulted in diagnostic innovations and new measurement capabilities that will improve understanding of transport, magnetic equilibrium, and electric fields in magnetically confined plasmas. We have developed novel hardware and advanced techniques to expand beam-based diagnostic capabilities, and extend measurements to new operating regimes. Some have been realized using a Heavy Ion Beam Probe (HIBP) having traditional features, while other applications have joined our innovations with subsets of advantageous HIBP features. This work has established smaller, more economical detection systems and, in doing so, may enable substantial extension of scenarios in which beam-based diagnostics are deployed. Key Measurement Innovations include: Computer Models and Simulations of HIBP Applications-Computer modeling and simulating of HIBP applications is central to predicting interaction of beam particles with plasmas, designing diagnostic systems, and anticipating measurement characteristics. We have extended the capability and improved measurement fidelity of the HIBP diagnostic on the Madison Symmetric Torus (MST) reversed field pinch (RFP); simulated feasibility of HIBP operation in the Helically Symmetric eXperiment (HSX) optimized stellarator; and investigated the plausibility of HIBP measurements in the ASDEX Upgrade tokamak. We have also developed a new technique that uses ion optics to model a finite phase-space beam. It yields more realistic (than traditional method) estimates of sample volume characteristics, which influence measurement resolution and sensitivity. Extension of Diagnostic Capabilities and Measurements on the MST RFP-Capabilities have been extended using the first and only HIBP installation on an RFP. Challenges associated with operation of the diagnostic on MST include the three-dimensional nature of particle trajectories, temporal topology and amplitude changes in the plasma equilibrium, and strong particle and radiative emission from the plasma. We have addressed these challenges through development of detailed and higher precision diagnostic simulations, calibrated subtraction of noise to resolve secondary ion signals, and implementation of hardware that enables higher fidelity measurement of plasma fluctuations. Development of New Hardware and Measurement Techniques - We have advanced beam-based measurement capabilities via development of new detectors and techniques to determine the poloidal magnetic flux ψ in the plasma, and enable placement of detectors close to the plasma and thus allow a smaller and less expensive diagnostic. We have demonstrated measurement of ψ, an ability that was made possible by development of highly effective noise reduction techniques. We also modeled the effect of non-ideal and instrumentation effects by developing a virtual (simulated) diagnostic. Application of beam-based diagnostics on various devices and multiple magnetic configurations (e.g. stellarator, tokamak, and reversed field pinch) enables investigation of critical physics issues and measurements resulting in the broad parameter space data needed to test and validate theory & modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron Neutrino Selection for Neutrino Oscillation Searches in the SBN Program

The Short- Baseline Neutrino (SBN) Pprogram at Fermilab employs a near detector, SBND, and a far detector, ICARUS, to search for baseline-dependent changes to the measure muon neutrino disappearance and electron neutrino appearance and disappearance from the muon neutrino-dominated Booster Neutrino Beam flux. The use of the same liquid argon time projection chamber (LArTPC) technology in both detectors and the same neutrino beam enables a systematically well-constrained oscillation measurement, by leveraging the high statistics of O(10 million) neutrino interactions expected at SBND through 2027 to constrain flux and cross-section systematics. In this poster, we present high-statistics, high-purity electron neutrino selections in SBND and ICARUS and related electron shower energy calibration measurements in SBND enabled by the SPINE deep learning-based particle reconstruction framework. Furthermore, we discuss how these samples can enable high sensitivity to '3+1' sterile neutrino oscillations in a combined fit accounting for systematic uncertainties and correlations.

Oza, Nupur [Nevis Labs, Columbia U.; Columbia U.]↗

Accurate determination of production data of the non-standard positron emitter 86 Y via the 86 Sr(p,n)-reaction

In view of several significant discrepancies in the excitation function of the 86 Sr(p,n) 86g+xm Y reaction which is the method of choice for the production of the non-standard positron emitter 86 Y for theranostic application, we carried out a careful measurement of the cross sections of this reaction from its threshold up to 16.2 MeV at Forschungszentrum Jülich (FZJ) and from 14.3 to 24.5 MeV at LBNL. Thin samples of 96.4% enriched 86 SrCO 3 were prepared by sedimentation and, after irradiation with protons in a stacked-form, the induced radioactivity was measured by high-resolution γ -ray spectrometry. The projectile flux was determined by using the monitor reactions nat Cu(p,xn) 62,63,65 Zn and nat Ti(p,x) 48 V, and the calculated proton energy for each sample was verified by considering the ratios of two reaction products of different thresholds. Additionally, the experimental cross section data obtained agreed well with the results of a nuclear model calculation based on the code TALYS. From the cross section data, the integral yield of 86 Y was calculated. Over the optimum production energy range E p = 14 → 7 MeV the yield of 86 Y amounts to 291 MBq/μA for 1 h irradiation time. This value is appreciably lower than the previous literature values calculated from measured and evaluated excitation functions. It is, however, more compatible with the experimental yields of 86 Y obtained in clinical scale production runs. The levels of the isotopic impurities 87m Y, 87g Y, and 88 Y were also estimated and found to be <2% in sum.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Temperature-dependent diffuse reflectance measurements of ceramic powders in the near- and mid-infrared spectra

Radiative properties are critical to quantify radiative energy fluxes between surfaces and in participating media. However, there is limited experimental data on temperature-dependent radiative properties of materials. Herein, this work focuses on experimentally measuring temperature-dependent diffuse reflectance in the near- and mid-infrared spectra (1–20 μm) for ceramic particles with applications as heat-transfer and thermal-storage media in concentrated solar power (CSP) plants. Specifically, a commercially available sintered bauxite proppant, ACCUCAST ID80, and its primary chemical constituents—alumina (Al 2 O 3 ) and silica (SiO 2 )—are measured in powder form using a Fourier transform infrared spectrometer (FTIR) coupled with a specialized diffuse reflectance accessory and a heated stage. Room-temperature diffuse reflectance measurements show increased absorption in tests with greater mass fractions of the ceramic samples. There is a strong correlation in the measured reflectance spectra of ACCUCAST with alumina and silica in the spectral range 2000–500 cm –1 (5–20 μm). Whereas, for shorter wavelengths (< 5 μm), the absorptance for ACCUCAST is greater than the absorptance for alumina and silica, indicating contributions from other chemical species present in the composite material. For the first time, temperature-dependent diffuse reflectance measurements are reported for ACCUCAST up to 1000 °C. These results are compared against those of alumina and silica through the calculation of a thermal emittance. All three materials exhibit a calculated emittance of ~0.9 at room temperature. However, this value decreases to ~0.6 for ACCUCAST and drops to less than 0.4 for alumina and silica at 1000 °C. Thermal cycling in air at 1000 °C resulted in a visible color change from dark grey to light orange for ACCUCAST and a subsequent larger increase in reflectance for wavelengths less than 5 μm as compared to ACCUCAST thermally cycled at 1000 °C in vacuum. Alumina and silica spectra proved to be largely unaffected by thermal cycling under atmospheric conditions. Overall, this study establishes a powerful technique for the characterization of radiative properties of particulate materials as a function of temperature and presents a detailed case study of ACCUCAST, a candidate for next-generation particle-based CSP.

14 SOLAR ENERGY↗

Kinetic simulations verifying reconnection rates measured in the laboratory, spanning the ion-coupled to near electron-only regimes

The rate of reconnection characterizes how quickly flux and mass can move into and out of the reconnection region. In the Terrestrial Reconnection EXperiment (TREX), the rate at which the antiparallel asymmetric reconnection occurs is modulated by the presence of a shock and a region of flux pileup in the high-density inflow. Simulations utilizing a generalized Harris-sheet geometry have tentatively shown agreement with TREX's measured reconnection rate scaling relative to system size, which is indicative of the transition from ion-coupled toward electron-only reconnection. Here, in this study, we present simulations tailored to reproduce the specific TREX geometry, which confirm both the reconnection rate scale and the shock jump conditions previously characterized experimentally in TREX. The simulations also establish an interplay between the reconnection layer and the Alfvénic expansions of the background plasma associated with the energization of the TREX drive coils; this interplay has not yet been experimentally observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Differential Measurement of Circumstellar Extinction for AA Tau’s 2011 Dimming Event

AA Tau is a classical T Tauri star with a highly inclined, warped circumstellar disk. For decades, AA Tau exhibited photometric and spectroscopic variabilities that were successfully modeled as occultations of the primary star by circumstellar material. In 2011, AA Tau entered an extended faint state, presumably due to enhanced levels of circumstellar dust. We use two sets of contemporaneous optical–near-IR (NIR) spectra of AA Tau, obtained in 2008 and 2014 December, to directly measure the wavelength-dependent extinction associated with the dust enhancement driving AA Tau’s 2011 optical fade. Taken alone, AA Tau’s apparent optical–NIR increased extinction curve cannot be fit well with standard extinction laws. At optical wavelengths, AA Tau’s dimming event is consistent with predictions of common extinction models for an increase of A {sub V} = 2, but no such model reproduces AA Tau’s color–color excess at NIR wavelengths. We show that veiling emission accounts for the apparent anomalous NIR extinction: after including this veiling flux, AA Tau’s dimming event is consistent with a standard A {sub V} = 2 extinction law across the full optical–NIR range. We also report an increase in AA Tau’s mid-IR flux since its 2011 fade and suggest that an increase in the height of AA Tau’s inner disk is the most likely explanation for both the IR brightening and the additional extinction along the line of sight. In addition to informing our understanding of AA Tau, this analysis demonstrates that caution should be exercised when inferring extinction (and stellar parameters) from the NIR color–color excess of young stars with measurable NIR veiling fluxes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent elastic neutrino-nucleus scattering at the European Spallation Source

The European Spallation Source (ESS), presently well on its way to completion, will soon provide the most intense neutron beams for multi-disciplinary science. Fortuitously, it will also generate the largest pulsed neutrino flux suitable for the detection of Coherent Elastic Neutrino-Nucleus Scattering (CEνNS), a process recently measured for the first time at ORNL’s Spallation Neutron Source. We describe innovative detector technologies maximally able to profit from the order-of-magnitude increase in neutrino flux provided by the ESS, along with their sensitivity to a rich particle physics phenomenology accessible through high-statistics, precision CEνNS measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗