Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Two-Phase Calorimetry. II. Studies on the Thermodynamics of Cesium and Strontium Extraction by Mixtures of H+CCD- and PEG-400 in FS-13

Thermochemical characterization of the partitioning of cesium and strontium from nitric acid solutions into mixtures of the acid form of chlorinated cobalt dicarbollide (H+CCD-) and polyethylene glycol (PEG-400) in FS-13 diluent has been completed using isothermal titration microcalorimetry and radiotracer distribution methods. The phase transfer reaction for Cs+ is a straightforward (H+ for Cs+) cation exchange reaction. In contrast, the extraction of Sr2+ does not proceed in the absence of the co-solvent molecule PEG-400. This molecule is believed to facilitate the dehydration of the Sr2+ aquo cation to overcome its resistance to partitioning. The phase transfer reactions for both Cs+ and Sr2+ are enthalpy driven (exothermic), but partially compensated by an unfavorable entropy. The results of the calorimetry studies suggest that the PEG-400 functions as a stoichiometric phase transfer reagent rather than acting simply as a phase transfer catalyst or phase modifier. The calorimetry results also demonstrate that the extraction of Sr2+ is complex, including evidence for both the partitioning of Sr(NO3)+ and endothermic ion pairing interactions in the organic phase that contribute to the net enthalpic effect. The thermodynamics of the liquid-liquid distribution equilibria are discussed mainly considering the basic features of the ion solvation thermochemistry.

calorimetry↗

Adaptive Online Multivariate Signal Extraction With Locally Weighted Robust Polynomial Regression

High-frequency, multivariate data collected in real-time and used to control or make decisions regarding a process’ operation often contain some noise and outliers. Thus, a method to extract the signal is needed in order to reduce the number and magnitude of control-based adjustments that are implemented. Such a method must be (i) online, depending only on past and current observations; (ii) fast, producing a smooth value more quickly than the measurement frequency; (iii) robust, ignoring brief bursts of erroneously measured values; (iv) multivariate, ignoring observations that are jointly unusual; (v) adaptive, adjusting to periods of rapid fluctuation in the signal versus periods of stability; and (vi) purely data-driven, not incorporating any information about the process from which the data are collected. Most existing methods are only able to address a subset of these six features. Furthermore, we also require the method to be nonlinear, providing a local nonlinear estimate of the signal. In this work, we propose a novel, real-time signal extraction method based on a local, robust polynomial fit. We demonstrate the performance of our method compared to a state-of-the-art competitor through simulation. For illustration, the methodology is applied to data collected from a reverse osmosis water treatment process.

97 MATHEMATICS AND COMPUTING↗

Automatic information extraction from childhood cancer pathology reports

The International Classification of Childhood Cancer (ICCC) facilitates the effective classification of a heterogeneous group of cancers in the important pediatric population. However, there has been no development of machine learning models for the ICCC classification. We developed deep learning-based information extraction models from cancer pathology reports based on the ICD-O-3 coding standard. In this article, we describe extending the models to perform ICCC classification. We developed 2 models, ICD-O-3 classification and ICCC recoding (Model 1) and direct ICCC classification (Model 2), and 4 scenarios subject to the training sample size. We evaluated these models with a corpus consisting of 29206 reports with age at diagnosis between 0 and 19 from 6 state cancer registries. Our findings suggest that the direct ICCC classification (Model 2) is substantially better than reusing the ICD-O-3 classification model (Model 1). Applying the uncertainty quantification mechanism to assess the confidence of the algorithm in assigning a code demonstrated that the model achieved a micro-F1 score of 0.987 while abstaining (not sufficiently confident to assign a code) on only 14.8% of ambiguous pathology reports. Our experimental results suggest that the machine learning-based automatic information extraction from childhood cancer pathology reports in the ICCC is a reliable means of supplementing human annotators at state cancer registries by reading and abstracting the majority of the childhood cancer pathology reports accurately and reliably.

60 APPLIED LIFE SCIENCES↗

Leaky ion extraction method for dielectronic recombination strength measurements at electron-beam ion traps

There are a number of mechanisms via which ions and electrons interact in a plasma, but by far one of the most important is through dielectronic recombination (DR). This is a resonant process through which an ion can capture a free electron and decrease its charge by one unit. Cross sections or strengths for this process are of vital importance in the modeling of hot plasmas and hence any advance in measurement or calculation procedures for obtaining DR data is of great importance. The work presented here examines the underlying basis of a newly developed method based on leaky mode ion extraction from an electron beam ion trap (EBIT), for relatively quickly obtaining DR strengths. The development attains to use the ratio of the leaked ions in adjacent charge states, i.e., the initial and final charge states of a DR process, to obtain the strengths preassuming that this ratio is the same as that of the ions remaining inside the EBIT trap. This work shows this assumption to be false. Hence DR strengths measured using leaked ions may be subject to error. But this work also reveals that the difference between this ratio and the one for trapped ions is insensitive to most of the experimental conditions, which means reliable DR strengths can still be obtained by leaky mode ion extraction if proper corrections are applied. An example is shown in this paper where after correction of some experimental results for DR strengths, obtained using the leaky mode, excellent agreement with corresponding theoretical calculations is obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gravitational-wave extraction from neutron-star oscillations: Comparing linear and nonlinear techniques

The main aim of this study is the comparison of gravitational waveforms obtained from numerical simulations which employ different numerical evolution approaches and different wave-extraction techniques. For this purpose, we evolve an oscillating, nonrotating, polytropic neutron-star model with two different approaches: a full nonlinear relativistic simulation (in three dimensions) and a linear simulation based on perturbation theory. The extraction of the gravitational-wave signal is performed via three methods: the gauge-invariant curvature-perturbation theory based on the Newman-Penrose scalar {psi}{sub 4}; the gauge-invariant Regge-Wheeler-Zerilli-Moncrief metric-perturbation theory of a Schwarzschild space-time; some generalization of the quadrupole emission formula.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fluctuations in Extractable Work Bound the Charging Power of Quantum Batteries

We study the connection between the charging power of quantum batteries and the fluctuations of the extractable work. We prove that in order to have a non-zero rate of change of the extractable work, the state of the battery cannot be an eigenstate of a ‘free energy operator’, which characterizes the free energy of a system. We do so by proving that fluctuations in the free energy operator upper bound the charging power of a quantum battery. Our findings also suggest that quantum coherence in the battery enhances the charging process, which we illustrate on a toy model of a heat engine.

74 ATOMIC AND MOLECULAR PHYSICS↗

SANS Study of Cellulose Extracted from Switchgrass

AbstractLignocellulosic biomass, an abundant renewable natural resource, has the potential to play a major role in generation of renewable biofuels through its conversion to bio-ethanol. Unfortunately, it is a complex biological composite material that shows significant recalcitrance making it a cost-ineffective feedstock for bioethanol production. Small-angle neutron scattering (SANS) was employed to probe the multi-scale structure of cellulosic materials. Cellulose was extracted from milled native switchgrass and switchgrass that had undergone the dilute acid pretreatment method to disrupt the lignocellulose structure. The high-Q structural feature (Q > 0.07 Å-1) can be assigned to cellulose fibrils based on comparison with the switchgrass purified by solvent extraction of native and dilute acid pretreated and a commercial preparation of microcrystalline cellulose. Dilute acid pretreatment results in an increase in the smallest structural size, a decrease in the interconnectivity of the fibrils; and no change in the smooth domain boundaries at length scales larger than 1000 Å.

09 BIOMASS FUELS↗

Deep Learning for Automated Extraction of Primary Sites from Cancer Pathology Reports

Pathology reports are a primary source of information for cancer registries which process high volumes of free-text reports annually. Information extraction and coding is a manual, labor-intensive process. Here in this study we investigated deep learning and a convolutional neural network (CNN), for extracting ICDO- 3 topographic codes from a corpus of breast and lung cancer pathology reports. We performed two experiments, using a CNN and a more conventional term frequency vector approach, to assess the effects of class prevalence and inter-class transfer learning. The experiments were based on a set of 942 pathology reports with human expert annotations as the gold standard. CNN performance was compared against a more conventional term frequency vector space approach. We observed that the deep learning models consistently outperformed the conventional approaches in the class prevalence experiment, resulting in micro and macro-F score increases of up to 0.132 and 0.226 respectively when class labels were well populated. Specifically, the best performing CNN achieved a micro-F score of 0.722 over 12 ICD-O-3 topography codes. Transfer learning provided a consistent but modest performance boost for the deep learning methods but trends were contingent on CNN method and cancer site. Finally, these encouraging results demonstrate the potential of deep learning for automated abstraction of pathology reports.

59 BASIC BIOLOGICAL SCIENCES↗

Automatic Crack Segmentation and Feature Extraction in Electroluminescence Images of Solar Modules

The effect of cracks in solar cells on the long-term degradation of photovoltaic (PV) modules remains to be determined. To investigate this effect in future studies, it is necessary to quantitatively describe the crack features (e.g., length) and correlate them with module power loss. Electroluminescence (EL) imaging is a common technique for identifying cracks. However, it is currently challenging and time-consuming to identify cracks in a large number of EL images and quantify complex crack features by human inspection. This article introduces a fast semantic segmentation method (~0.18 s/cell) to automatically segment cracks from EL images and algorithms to extract crack features. Here we fine-tuned a UNet neural network model using pretrained VGG16 as the encoder and obtained an average F1 score of 0.875 and an intersection over union score of 0.782 on the testing set. With cracks and busbars segmented, we developed algorithms for extracting crack features, including the crack-isolated area, the brightness inside the isolated area, and the crack length. We also developed an automatic preprocessing tool for cropping individual cell images from EL images of PV modules (~0.72 s/module). Our codes are published as open-source an software, and our annotated dataset composed of various types of cells is published as a benchmark for crack segmentation in EL images.

14 SOLAR ENERGY↗

Sparse Coding for N-Gram Feature Extraction and Training for File Fragment Classification

File fragment classification is an important step in the task of file carving in digital forensics. In file carving, files must be reconstructed based on their content as a result of their fragmented storage on disk or in memory. Existing methods for classification of file fragments typically use hand-engineered features such as byte histograms or entropy measures. In this paper, we propose an approach using sparse coding that enables automated feature extraction. Sparse coding, or sparse dictionary learning, is an unsupervised learning algorithm, and is capable of extracting features based simply on how well those features can be used to reconstruct the original data. With respect to file fragments, we learn sparse dictionaries for n-grams, continuous sequences of bytes, of different sizes. These dictionaries may then be used to estimate n-gram frequencies for a given file fragment, but for significantly larger n-gram sizes than are typically found in existing methods which suffer from combinatorial explosion. To demonstrate the capability of our sparse coding approach, we used the resulting features to train standard classifiers such as support vector machines (SVMs) over multiple file types. Experimentally, we achieved significantly better classification results with respect to existing methods, especially when the features were used in supplement to existing hand-engineered features.

97 MATHEMATICS AND COMPUTING↗

Extraction of depth-dependent perturbation factors for silicon diodes using a plastic scintillation detector

Purpose: This work presents the experimental extraction of the perturbation factor in megavoltage electron beams for three models of silicon diodes (IBA Dosimetry, EFD and SFD, and the PTW 60012 unshielded) using a plastic scintillation detector (PSD). Methods: The authors used a single scanning PSD mounted on a high-precision scanning tank to measure depth-dose curves in 6-, 12-, and 18-MeV clinical electron beams. They also measured depth-dose curves using the IBA Dosimetry, EFD and SFD, and the PTW 60012 unshielded diodes. The authors used the depth-dose curves measured with the PSD as a perturbation-free reference to extract the perturbation factors of the diodes. Results: The authors found that the perturbation factors for the diodes increased substantially with depth, especially for low-energy electron beams. The experimental results show the same trend as published Monte Carlo simulation results for the EFD diode; however, the perturbations measured experimentally were greater. They found that using an effective point of measurement (EPOM) placed slightly away from the source reduced the variation of perturbation factors with depth and that the optimal EPOM appears to be energy dependent. Conclusions: The manufacturer recommended EPOM appears to be incorrect at low electron energy (6 MeV). In addition, the perturbation factors for diodes may be greater than predicted by Monte Carlo simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-190: Time Resolved Range Measurement System Using Scintillator and CCD Camera for the Slow Beam Extraction

Purpose: To investigate the time structure of the range, we have verified the rang shift due to the betatron tune shift with several synchrotron parameters. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. Using image processing, the range was determined the 80 percent of distal dose of the depth light distribution. The root mean square error of the range measurement using the scintillator and CCD system is about 0.2 mm. Range measurement was performed at interval of 170 msec. The chromaticity of the synchrotron was changed in the range of plus or minus 1% from reference chromaticity in this study. All of the particle inside the synchrotron ring were extracted with the output beam intensity 1.8×10{sup 8} and 5.0×10{sub 7} particle per sec. Results: The time strictures of the range were changed by changing of the chromaticity. The reproducibility of the measurement was sufficient to observe the time structures of the range. The range shift was depending on the number of the residual particle inside the synchrotron ring. Conclusion: In slow beam extraction for scanned carbon-ion therapy, the range shift is undesirable because it causes the dose uncertainty in the target. We introduced the time-resolved range measurement using scintillator and CCD system. The scintillator and CCD system have enabled to verify the range shift with sufficient spatial resolution and reproducibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical Modeling of Ion-Optical Systems for Extraction of a Beam of Negative Hydrogen Ions and Its Acceleration and Matching with a Radio-Frequency Quadrupole Accelerator

A source of negative hydrogen ions is constructed at the Institute for High Energy Physics in order to raise the intensity of the U-70 accelerator complex using multiturn charge-exchange injection. The 3D ion-optical IBSimu simulation package was used to model and optimize the system for extraction of an ion beam from plasma, its acceleration to 100 keV, and matching with a radio-frequency quadrupole (RFQ) accelerator. The system of extraction of an ion beam with a current of 50 mA and electron-flow suppression was modeled. The magnetic transport channels with two solenoids and six quadrupole lenses were compared. The end goals of analysis of the matching channel were to obtain the needed Twiss parameters and to minimize the emittance growth at the RFQ input.

43 PARTICLE ACCELERATORS↗

Vacuum Permeator Analysis for Extraction of Tritium from DCLL Blankets

It is envisioned that tritium will be extracted from DCLL blankets using a vacuum permeator. We derive here an analytical solution for the extraction efficiency of a permeator tube, which is a function of only two dimensionless numbers: one that indicates whether radial transport is limited in the PbLi or in the solid membrane, and another that is the ratio of axial and radial transport times in the PbLi. The permeator efficiency is maximized by decreasing the velocity and tube diameter, and increasing the tube length. This is true regardless of the mass transport correlation used; we review several here and find that they differ little, and the choice of correlation is not a source of significant uncertainty here. The PbLi solubility, on the other hand, is a large source of uncertainty, and we identify upper and lower bounds from the literature data. Under the most optimistic assumptions, we find that a ferritic steel permeator operating at 550 °C will need to be at least an order of magnitude larger in volume than previous conceptual designs using niobium and operating at higher temperatures.

DCLL↗

In Situ Visualization and Production of Extract Databases

Simulations running at high concurrency on HPC systems generate large volumes of data that are impractical to write to disk due to time and storage constraints. Applications often adapt by saving data infrequently, resulting in datasets with poor temporal resolution. This can make datasets difficult to interpret during post hoc visualization and analysis, or worse, it can lead to lost science. In Situ visualization and analysis can enable efficient production of small data products such as rendered images or surface extracts that consist of polygonal geometry plus fields. These data products are far smaller than their source data and can be processed much more economically in a traditional post hoc workflow using far fewer computational resources. We used the SENSEI and Libsim in situ infrastructures to implement rendering workflow and surface data extraction workflows in the AVF-LESLIE combustion code. Finally, these workflows were then demonstrated at high levels of concurrency and showed significant data reductions and limited impact on the simulation runtime.

97 MATHEMATICS AND COMPUTING↗

Magnetic Nanofluid Rare Earth Element Extraction Process Report, Techno Economic Analysis, and Results for Geothermal Fluids

This GDR submission is an interim technical report and raw data files from the first year of testing on functionalized nanoparticles for rare earth element extraction from geothermal fluids. The report contains Rare Earth Element uptake results (percent removal, mg Rare Earth Element/gram of sorbent, distribution coefficient) for the elements of Neodymium, Europium, Yttrium, Dysprosium, and Cesium. A detailed techno economic analysis is also presented in the report for a scaled up geothermal rare earth element extraction process. All rare earth element uptake testing was done on simulated geothermal brines with one rare earth element in each brine. The rare earth element uptake testing was conducted at room temperature.

15 GEOTHERMAL ENERGY↗

RESULTS OF ROUTINE STRIP EFFLUENT HOLD TANK AND DECONTAMINATED SALT SOLUTION HOLD TANK SAMPLES FROM MODULAR CAUSTIC-SIDE SOLVENT EXTRACTION UNIT DURING MACROBATCH 3 OPERATIONS

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the 'microbatches' of Integrated Salt Disposition Project (ISDP) Salt Batch ('Macrobatch') 3 have been analyzed for {sup 238}Pu, {sup 90}Sr, {sup 137}Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES). The results indicate good decontamination performance within process design expectations. While the data set is sparse, the results of this set and the previous set of results for Macrobatch 3 samples indicate consistent operations. However, the Decontamination Factors for plutonium and strontium removal have declined in Macrobatch 3, compared to Macrobatch 2. This may be due to the differences in the Pu concentration or the bulk chemical concentrations in the feed material. SRNL is considering the possible reasons for this decline. The DSSHT samples show continued presence of titanium, likely from leaching of the monosodium titanate in ARP. During operation of the ISDP, quantities of salt waste are processed through the Actinide Removal Process (ARP) and MCU in batches of {approx}3800 gallons. Monosodium titanate (MST) is used in ARP to adsorb actinides and strontium from the salt waste and the waste slurry is then filtered prior to sending the clarified salt solution to MCU. The MCU uses solvent extraction technology to extract cesium from salt waste and concentrate cesium in an acidic aqueous stream (Strip Effluent - SE), leaving a decontaminated caustic salt aqueous stream (Decontaminated Salt Solution - DSS). Sampling occurs in the Decontaminated Salt Solution Hold Tank (DSSHT) and Strip Effluent Hold Tank (SEHT) in the MCU process. The MCU sample plan requires that batches be sampled and analyzed for plutonium and strontium content by Savannah River National Lab (SRNL) to determine MST effectiveness. The cesium measurement is used to monitor cesium removal effectiveness and the inductively coupled plasma emission spectroscopy (ICPES) is used to monitor inorganic carryover.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RESULTS FROM ANALYSIS OF THE FIRST AND SECOND STRIP EFFLUENT COALESCER ELEMENTS FROM RADIOACTIVE OPERATIONS OF THE MODULAR CAUSTIC-SIDE SOLVENT EXTRACTION UNIT

The coalescer elements for the Strip Effluent (SE) acid within the Modular Caustic-Side Solvent Extraction Unit (MCU) experienced elevated differential pressure drop during radioactive operations. Following the end of operations for the first Macrobatch campaign and soon after start of the second Macrobatch campaign, personnel removed the coalescer media and provided to Savannah River National Laboratory (SRNL) for diagnostic investigation of the causes of reduced flow. This report summarizes those studies. Two Strip Effluent (SE) coalescers were delivered to the Savannah River National Laboratory (SRNL). One was removed from the Modular Caustic-Side Solvent Extraction Unit (MCU) between processing of Macrobatch 1 and 2 (coalescer 'Alpha'), and the second was removed from MCU after processing of {approx}24,000 gallons of salt solution (coalescer 'Beta'). Both coalescers underwent the same general strip acid flush program to reduce the dose and were delivered to SRNL for analysis of potential occluding solids. Analysis of Coalescer Alpha indicates the presence of aluminum hydroxide solids and aluminosilicate solids, while analysis of Coalescer Beta indicates the presence of aluminum hydroxide solids, but no aluminosilicates. Leaching studies on sections of both coalescers were performed. The results indicate that the coalescers had different amounts of solids present on them at the time of removal. Finally, samples of free liquids retrieved from both coalescers indicate no excessive amounts of CSSX solvent present. Given the strip acid flushing that occurred in the SE coalescers, the solids we detected on the coalescers are probably indicative of a larger quantity of these solids present before the strip acid flushing. Under this scenario, the excessive pressure drops are due to the solids and not from organic fouling.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗