Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Error analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

HIGH-RESOLUTION SPECTROSCOPY DURING ECLIPSE OF THE YOUNG SUBSTELLAR ECLIPSING BINARY 2MASS 0535-0546. I. PRIMARY SPECTRUM: COOL SPOTS VERSUS OPACITY UNCERTAINTIES

We present high-resolution Keck optical spectra of the very young substellar eclipsing binary 2MASS J05352184-0546085, obtained during eclipse of the lower-mass (secondary) brown dwarf. The observations yield the spectrum of the higher-mass (primary) brown dwarf alone, with negligible ({approx}1.6%) contamination by the secondary. We perform a simultaneous fine analysis of the TiO-{epsilon} band and the red lobe of the K I doublet, using state-of-the-art PHOENIX DUSTY and COND synthetic spectra. Comparing the effective temperature and surface gravity derived from these fits to the empirically determined surface gravity of the primary (log g = 3.5) then allows us to test the model spectra as well as probe the prevailing photospheric conditions. We find that: (1) fits to TiO-{epsilon} alone imply T{sub eff} = 2500 {+-} 50 K; (2) at this T{sub eff}, fits to K I imply log g = 3.0, 0.5 dex lower than the true value; and (3) at the true log g, K I fits yield T{sub eff} = 2650 {+-} 50 K, {approx}150 K higher than from TiO-{epsilon} alone. On the one hand, these are the trends expected in the presence of cool spots covering a large fraction of the primary's surface (as theorized previously to explain the observed T{sub eff} reversal between the primary and secondary). Specifically, our results can be reproduced by an unspotted stellar photosphere with T{sub eff} = 2700 K and (empirical) log g = 3.5, coupled with axisymmetric cool spots that are 15% cooler (2300 K), have an effective log g = 3.0 (0.5 dex lower than photospheric), and cover 70% of the surface. On the other hand, the trends in our analysis can also be reproduced by model opacity errors: there are lacks in the synthetic TiO-{epsilon} opacities, at least for higher-gravity field dwarfs. Stringently discriminating between the two possibilities requires combining the present results with an equivalent analysis of the secondary (predicted to be relatively unspotted compared to the primary).

79 ASTRONOMY AND ASTROPHYSICS↗

Challenges in leveraging existing human performance data for quantifying the IDHEAS HRA method

Our article documents an exploratory study for collecting and using human performance data to inform human error probability (HEP) estimates for a new human reliability analysis (HRA) method, the IntegrateD Human Event Analysis System (IDHEAS). The method was based on cognitive models and mechanisms underlying human behaviour and employs a framework of 14 crew failure modes (CFMs) to represent human failures typical for human performance in nuclear power plant (NPP) internal, at-power events [1]. A decision tree (DT) was constructed for each CFM to assess the probability of the CFM occurring in different contexts. Data needs for IDHEAS quantification are discussed. Then, the data collection framework and process is described and how the collected data were used to inform HEP estimation is illustrated with two examples. Next, five major technical challenges are identified for leveraging human performance data for IDHEAS quantification. Furthermore, these challenges reflect the data needs specific to IDHEAS. More importantly, they also represent the general issues with current human performance data and can provide insight for a path forward to support HRA data collection, use, and exchange for HRA method development, implementation, and validation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microsegregation Measurement: Methods and Applications

Microsegregation is chemical variation at the microstructural level in a solidified ingot, which can cause undesirable effects on material properties. Its formation is driven by different levels of solute elemental solubility between solid and liquid phases, resulting in solute buildup or depletion in the liquid phase during solidification. Characterization of microsegregation can be essential for understanding its formation and removing it through heat treatment. Measurement is frequently carried out via scanning electron microscope (SEM), though metallographic analysis, mechanical testing and optical radiography have been used. SEM analysis can consist of point measurements on single dendrites, line scans across or along dendrites, elemental maps, and extended line-based or grid-based analyses extending over many dendrites, which can generate large amounts of data. Line-based or grid-based data can be analyzed using scatterplots of element concentrations to visualize segregation behavior and sorting/ranking of data by a single element or a combination of elements, to give compositional profiles as a function of extent of solidification. For both qualitative and quantitative analyses, effects of phase transformations and secondary phases need to be considered as well as sorting of measurement errors when generating compositional profiles. Applications of analysis include determination of partition ratios, examination of solute–element interactions, determination of effects of cooling rate and back diffusion, applications to freckling studies, validations of modeling, and development of heat-treatment profiles.

36 MATERIALS SCIENCE↗

Extended Forward Sensitivity Analysis for Uncertainty Quantification

Verification and validation (V&V) are playing more important roles to quantify uncertainties and realize high fidelity simulations in engineering system analyses, such as transients happened in a complex nuclear reactor system. Traditional V&V in the reactor system analysis focused more on the validation part or did not differentiate verification and validation. The traditional approach to uncertainty quantification is based on a 'black box' approach. The simulation tool is treated as an unknown signal generator, a distribution of inputs according to assumed probability density functions is sent in and the distribution of the outputs is measured and correlated back to the original input distribution. The 'black box' method mixes numerical errors with all other uncertainties. It is also not efficient to perform sensitivity analysis. Contrary to the 'black box' method, a more efficient sensitivity approach can take advantage of intimate knowledge of the simulation code. In these types of approaches equations for the propagation of uncertainty are constructed and the sensitivities are directly solved for as variables in the simulation. This paper presents the forward sensitivity analysis as a method to help uncertainty qualification. By including time step and potentially spatial step as special sensitivity parameters, the forward sensitivity method is extended as one method to quantify numerical errors. Note that by integrating local truncation errors over the whole system through the forward sensitivity analysis process, the generated time step and spatial step sensitivity information reflect global numerical errors. The discretization errors can be systematically compared against uncertainties due to other physical parameters. This extension makes the forward sensitivity method a much more powerful tool to help uncertainty qualification. By knowing the relative sensitivity of time and space steps with other interested physical parameters, the simulation is allowed to run at optimized time and space steps without affecting the confidence of the physical parameter sensitivity results. The time and space steps forward sensitivity analysis method can also replace the traditional time step and grid convergence study with much less computational cost. Several well defined benchmark problems with manufactured solutions are utilized to demonstrate the extended forward sensitivity analysis method. All the physical solutions, parameter sensitivity solutions, even the time step sensitivity in one case, have analytical forms, which allows the verification to be performed in the strictest sense.

97 MATHEMATICS AND COMPUTING↗

HUBBLE PARAMETER MEASUREMENT CONSTRAINTS ON DARK ENERGY

We use 21 Hubble parameter versus redshift data points from Simon et al., Gaztanaga et al., Stern et al., and Moresco et al. to place constraints on model parameters of constant and time-evolving dark energy cosmologies. The inclusion of the eight new measurements results in H(z) constraints more restrictive than those derived by Chen and Ratra. These constraints are now almost as restrictive as those that follow from current Type Ia supernova (SNIa) apparent magnitude versus redshift data, which now more carefully account for systematic uncertainties. This is a remarkable result. We emphasize, however, that SNIa data have been studied for a longer time than the H(z) data, possibly resulting in a better estimate of potential systematic errors in the SNIa case. A joint analysis of the H(z), baryon acoustic oscillation peak length scale, and SNIa data favors a spatially flat cosmological model currently dominated by a time-independent cosmological constant but does not exclude slowly evolving dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Where post-Newtonian and numerical-relativity waveforms meet

We analyze numerical-relativity (NR) waveforms that cover nine orbits (18 gravitational-wave cycles) before merger of an equal-mass system with low eccentricity, with numerical uncertainties of 0.25 radians in the phase and 2% in the amplitude; such accuracy allows a direct comparison with post-Newtonian (PN) waveforms. We focus on waveforms predicted by one of the PN approximants that has been proposed for use in gravitational-wave data analysis, restricted 3.5PN TaylorT1, and compare these with a section of the numerical waveform from the second to the eighth orbit, which is about one and a half orbits before merger. This corresponds to a gravitational-wave frequency range of M{omega}=0.0455 to 0.1 Depending on the method of matching PN and NR waveforms, the accumulated phase disagreement over this frequency range can be within numerical uncertainty. Similar results are found in comparisons with an alternative PN approximant, 3PN TaylorT3. The amplitude disagreement, on the other hand, is around 6%, but roughly constant for all 13 cycles that are compared, suggesting that for the purpose of producing 'hybrid waveforms', only 4.5 orbits need be simulated to match PN and NR waves with the same accuracy as is possible with nine orbits. If, however, we model the amplitude up to 2.5PN order, numerical and post-Newtonian amplitude disagreement is close to the numerical error of 2%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Erratum: ?Stimulated Brillouin Backscattering and Ion Acoustic Wave Secondary Instability? [Phys. Plasmas 16, 032701 (2009)]

This Erratum addresses errors that occurred in some of the analysis in our recent publication (Ref. 1). The main elements of Ref. 1 are (1) the presentation of kinetic simulations of simulated Brillouin backscattering (SBS) and the accompanying secondary instability of the primary SBS ion acoustic wave (IAW) with and without the inclusion of the second harmonic of the primary IAW; (2) analyses of the four-wave (primary IAW, low-frequency IAW, and two sidebands of the primary IAW) and seven-wave (includes the second harmonic of the primary IAW and its two sidebands, as well as the four waves defined in the foregoing) dispersion relations for the secondary IAW instability; (3) comparisons of the results of solving the dispersion relations to the two particle simulations; (4) mode coupling calculations for SBS and the four-wave system of IAWs that model the particle simulations; and (5) a discussion and summary. However, the simplified 7-wave dispersion relation used in Ref. 1 propagated a typographical error in Eq.(44) in Ref. 2, the Pesme, Riconda, and Tikhonchuk (PRT) paper. This Erratum corrects Eq.(44) of Ref. 2 (discussed in more detail in an Erratum3 for Ref. 2) and revises Sec. IV of Ref. 1 by correcting the analysis and comparisons of the 4-wave and 7-wave dispersion relations, and the comparison of the 7-wave dispersion relation to the particle simulations. We find that the results of the corrected 7-wave dispersion relation are not profoundly different from the corresponding results in Ref. 1 and the 7-wave growth rates of the most unstable modes are more similar to the results of the 4-wave dispersion relation. The main results of Ref. 1 are unchanged: (1) the particle simulations exhibit a secondary IAW instability that is a modulational instability involving parallel and obliquely propagating IAWs; (2) the two types of particle simulation exhibit similar spectra, and the second harmonic IAW is a transient feature in the first particle simulation that is not well differentiated from the noise in the streak spectra shown in Ref. 1; (3) the 4-wave dispersion relation fits the simulation data relatively well, and only the 4-wave dispersion relation is applicable to the simulation with the second harmonic IAW suppressed; (4) the results of the 7-wave dispersion relation do not differ profoundly from the 4-wave results for the modulational instability when frequency mismatch effects are included; and (5) it is problematic justifying the application of the 7-wave dispersion relation even to the first particle simulation because the second harmonic signal is either transient or weak. The 7-wave dispersion relation is not a primary focus of Ref. 1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Markov chain Monte Carlo (MCMC) Bayesian inference approach to analyze apparent activation barriers and reaction orders from microreactor data

Statistical analysis of steady-state catalytic kinetic data is often limited by data sparsity due to the slow pace at which the data is collected. Data sparsity and limitations in statistical analysis make it difficult to differentiate between mechanistic models and catalytic sites. A Bayesian inference tool is reported for catalysis researchers to estimate error in the determination of reaction orders from steady state microreactor data. The benefits of a Bayesian inference approach are discussed, as an alternative to the more common frequentist approach. The approach incorporates prior knowledge of the system and the data collected to form an error estimate on reaction orders. We investigated the effects of three distinct data treatments—individual fitting of trials, pooled analysis, and constrained regression methods—on the precision and uncertainty of reaction order determinations. To assess the robustness of our findings, we conducted sensitivity analyses to evaluate the influence of Bayesian parameters on uncertainty estimation. Additionally, we utilized synthetic data to illustrate how data quality impacts the precision of uncertainty assessments. We show Bayesian analysis can obtain a more precise estimation of error with a sparse data set than a frequentist analysis. Finally, this work provides strong evidence that the adoption of Bayesian analysis of kinetic data may help researchers make more precise arguments as to the strength of their evidence for a particular mechanistic hypothesis, or in comparing across different catalysts.

42 ENGINEERING↗

Subtlety of TiO 2 phase stability: Reliability of the density functional theory predictions and persistence of the self-interaction error

TiO 2 is an important material with broad applications that can exist in different phases with dramatically different properties. Theoretical prediction of their polymorph energetics is therefore critical for the material design and for identifying thermodynamically accessible structures. Determining TiO 2 relative phase stabilities remains challenging for first-principles methods, and density functional theory is the only approach available for studying phase stabilities at finite temperatures with acceptable computational efficiency. Here, we show that density functional theory using the recently developed efficient strongly constrained and appropriately normed (SCAN) [Sun et al., Phys. Rev. Lett. 115, 036402 (2015)] exchange-correlation functional for the first time predicts the phase stability in qualitative agreement with the experimental results at realistic conditions. Further analysis shows that the self-interaction error intrinsic in the density functional persists in the stability prediction. By correcting the self-interaction error through an empirical approach, SCAN predicts the relative stability as well as defect properties in excellent agreement with the experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Framework for Error-Bounded Approximate Computing, with an Application to Dot Products

Approximate computing techniques, which trade off the computation accuracy of an algorithm for better performance and energy efficiency, have been successful in reducing computation and power costs in several domains. However, error sensitive applications in high-performance computing are unable to benefit from existing approximate computing strategies that are not developed with guaranteed error bounds. While approximate computing techniques can be developed for individual high-performance computing applications by domain specialists, this often requires additional theoretical analysis and potentially extensive software modification. Hence, the development of low-level error-bounded approximate computing strategies that can be introduced into any high-performance computing application without requiring additional analysis or significant software alterations is desirable. In this paper, we provide a contribution in this direction by proposing a general framework for designing error-bounded approximate computing strategies and apply it to the dot product kernel to develop \bf qdot---an error-bounded approximate dot product kernel. Following the introduction of qdot, here we perform a theoretical analysis that yields a deterministic bound on the relative approximation error introduced by qdot. Empirical tests are performed to illustrate the tightness of the derived error bound and to demonstrate the effectiveness of qdot on a synthetic dataset, as well as two scientific benchmarks---the conjugate gradient (CG) and power methods. In some instances, using qdot for the dot products in CG can result in many components being quantized to half precision without increasing the iteration count required for convergence to the same solution as CG using a double precision dot product.

97 MATHEMATICS AND COMPUTING↗

Emulating Baryonic Effects in Weak Lensing Measurements

Baryonic effects are one of the most serious systematics to the tomographic analysis of weak lensing statistical measurements. We are working on a novel method for correcting cosmological observations for baryonic effects - a term used to label the fact that we observe galaxies, while theoretical modeling at present is only accurate enough for the dynamics of dark matter. Although modern cosmological simulations of dark matter (the “dark matter only", or DMO simulations) consistently reach the required 1% level of precision, the effect of baryonic physics on cosmological scales is expected to be a source of a much more severe systematic error in weak lensing measurements. In this analysis we apply a general framework to consistently include systematic effects into a likelihood analysis for cosmological surveys, such as the Dark Energy Survey (DES), and future Large Synoptic Survey Telescope survey (LSST).

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of over-magnetization of elemental transition metal solids from the SCAN density functional

Current investigations have revealed that the strongly constrained and appropriately normed (SCAN) meta-generalized gradient approximation exchange-correlation functional significantly over-magnetizes elemental Fe, Co, and Ni solids. For the paradigmatic case, bcc Fe, the error relative to experiment is ≳ 20 % . A comparative analysis of magnetization results from SCAN and its deorbitalized counterpart, SCAN-L, leads to identification of the source of the discrepancy. It is not from the difference between Kohn-Sham (SCAN-L) and generalized Kohn-Sham (SCAN) procedures. The key is the iso-orbital indicator α (the ratio of the local Pauli and Thomas-Fermi kinetic energy densities). Its deorbitalized counterpart α L has more dispersion in both spin channels with respect to magnetization in an approximate region between 0.6 and 1.2 bohrs around an Fe nucleus. The overall effect is that the SCAN switching function evaluated with α L reduces the energetic disadvantage of the down channel with respect to up compared to the original α , which in turn reduces the magnetization. This identifies the origin of the SCAN magnetization error as insensitivity of the SCAN switching function to α values in the approximate range 0.5 ≲ α ≲ 0.8 and oversensitivity for α ≳ 0.8 .

36 MATERIALS SCIENCE↗

Comparative analysis of image binarization methods for crack identification in concrete structures

Surface cracks in concrete structures are critical indicators of structural damage and durability. Manual visual inspection, the most commonly used method in practice, is inefficient from cost, time, accuracy, and safety perspectives. A promising alternative is computer vision-based methods that can automatically extract crack information from images. Image binarization, developed for text detection, is appropriate for crack identification, as texts and cracks are similar, consisting of distinguishable lines and curves. However, standardizing crack identification using image binarization is challenging, because binarization depends on the method and associated parameters. We investigate image binarization for crack identification, focusing on optimal parameter determination and comparative performance evaluation for five common binarization methods. Crack images are prepared to obtain optimal parameters by minimizing errors in estimated crack widths. Subsequently, comparative analysis is conducted using crack images with different conditions based on three performance evaluation criteria: crack width and length measurement accuracy and computation time.

36 MATERIALS SCIENCE↗

The completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: BAO and RSD measurements from the anisotropic power spectrum of the quasar sample between redshift 0.8 and 2.2

ABSTRACT We measure the clustering of quasars of the final data release (DR16) of eBOSS. The sample contains $343\, 708$ quasars between redshifts 0.8 ≤ z ≤ 2.2 over $4699\, \mathrm{deg}^2$. We calculate the Legendre multipoles (0,2,4) of the anisotropic power spectrum and perform a BAO and a Full-Shape (FS) analysis at the effective redshift zeff = 1.480. The errors include systematic errors that amount to 1/3 of the statistical error. The systematic errors comprise a modelling part studied using a blind N-body mock challenge and observational effects studied with approximate mocks to account for various types of redshift smearing and fibre collisions. For the BAO analysis, we measure the transverse comoving distance DM(zeff)/rdrag = 30.60 ± 0.90 and the Hubble distance DH(zeff)/rdrag = 13.34 ± 0.60. This agrees with the configuration space analysis, and the consensus yields: DM(zeff)/rdrag = 30.69 ± 0.80 and DH(zeff)/rdrag = 13.26 ± 0.55. In the FS analysis, we fit the power spectrum using a model based on Regularised Perturbation Theory, which includes redshift space distortions and the Alcock–Paczynski effect. The results are DM(zeff)/rdrag = 30.68 ± 0.90 and DH(zeff)/rdrag = 13.52 ± 0.51 and we constrain the linear growth rate of structure f(zeff)σ8(zeff) = 0.476 ± 0.047. Our results agree with the configuration space analysis. The consensus analysis of the eBOSS quasar sample yields: DM(zeff)/rdrag = 30.21 ± 0.79, DH(zeff)/rdrag = 3.23 ± 0.47, and f(zeff)σ8(zeff) = 0.462 ± 0.045 and is consistent with a flat ΛCDM cosmological model using Planck results.

Neveux, Richard↗

Image-based spectral distortion correction for photon-counting x-ray detectors

Purpose: To investigate the feasibility of using an image-based method to correct for distortions induced by various artifacts in the x-ray spectrum recorded with photon-counting detectors for their application in breast computed tomography (CT). Methods: The polyenergetic incident spectrum was simulated with the tungsten anode spectral model using the interpolating polynomials (TASMIP) code and carefully calibrated to match the x-ray tube in this study. Experiments were performed on a Cadmium-Zinc-Telluride (CZT) photon-counting detector with five energy thresholds. Energy bins were adjusted to evenly distribute the recorded counts above the noise floor. BR12 phantoms of various thicknesses were used for calibration. A nonlinear function was selected to fit the count correlation between the simulated and the measured spectra in the calibration process. To evaluate the proposed spectral distortion correction method, an empirical fitting derived from the calibration process was applied on the raw images recorded for polymethyl methacrylate (PMMA) phantoms of 8.7, 48.8, and 100.0 mm. Both the corrected counts and the effective attenuation coefficient were compared to the simulated values for each of the five energy bins. The feasibility of applying the proposed method to quantitative material decomposition was tested using a dual-energy imaging technique with a three-material phantom that consisted of water, lipid, and protein. The performance of the spectral distortion correction method was quantified using the relative root-mean-square (RMS) error with respect to the expected values from simulations or areal analysis of the decomposition phantom. Results: The implementation of the proposed method reduced the relative RMS error of the output counts in the five energy bins with respect to the simulated incident counts from 23.0%, 33.0%, and 54.0% to 1.2%, 1.8%, and 7.7% for 8.7, 48.8, and 100.0 mm PMMA phantoms, respectively. The accuracy of the effective attenuation coefficient of PMMA estimate was also improved with the proposed spectral distortion correction. Finally, the relative RMS error of water, lipid, and protein decompositions in dual-energy imaging was significantly reduced from 53.4% to 6.8% after correction was applied. Conclusions: The study demonstrated that dramatic distortions in the recorded raw image yielded from a photon-counting detector could be expected, which presents great challenges for applying the quantitative material decomposition method in spectral CT. The proposed semi-empirical correction method can effectively reduce these errors caused by various artifacts, including pulse pileup and charge sharing effects. Furthermore, rather than detector-specific simulation packages, the method requires a relatively simple calibration process and knowledge about the incident spectrum. Therefore, it may be used as a generalized procedure for the spectral distortion correction of different photon-counting detectors in clinical breast CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum process tomography of a Mølmer-Sørensen gate via a global beam

Here, we present a framework for quantum process tomography of two-ion interactions that leverages modulations of the trapping potential and composite pulses from a global laser beam to achieve individual-ion addressing. Tomographic analysis of identity and delay processes reveals dominant error contributions from laser decoherence and slow qubit frequency drift during the tomography experiment. We use this framework on two co-trapped 40 Ca + ions to analyze both an optimized and an overpowered Mølmer–Sørensen gate and to compare the results of this analysis to a less informative Bell-state tomography measurement and to predictions based on a simplified noise model. These results show that the technique is effective for the characterization of two-ion quantum processes and for the extraction of meaningful information about the errors present in the system. The experimental convenience of this method will allow for more widespread use of process tomography for characterizing entangling gates in trapped-ion systems.

quantum computing↗

Lightweight and Statistical Techniques for Petascale PetaScale Debugging

This project investigated novel techniques for debugging scientific applications on petascale architectures. In particular, we developed lightweight tools that narrow the problem space when bugs are encountered. We also developed techniques that either limit the number of tasks and the code regions to which a developer must apply a traditional debugger or that apply statistical techniques to provide direct suggestions of the location and type of error. We extend previous work on the Stack Trace Analysis Tool (STAT), that has already demonstrated scalability to over one hundred thousand MPI tasks. We also extended statistical techniques developed to isolate programming errors in widely used sequential or threaded applications in the Cooperative Bug Isolation (CBI) project to large scale parallel applications. Overall, our research substantially improved productivity on petascale platforms through a tool set for debugging that complements existing commercial tools.

97 MATHEMATICS AND COMPUTING↗

In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: Feasibility study

Purpose: In gynecological radiotherapy with high dose rate (HDR){sup 192}Ir brachytherapy, the treatment complexity has increased due to improved optimization techniques and dose constraints. As a consequence, it has become more important to verify the dose delivery to the target and also to the organs at risk (e.g., the bladder). In vivo dosimetry, where dosimeters are placed in or on the patient, is one way of verifying the dose but until recently this was hampered by motion of the radiation detectors with respect to the source. The authors present a novel dosimetry method using a position sensitive radiation detector. Methods: The prototype RADPOS system (Best Medical Canada) consists of a metal oxide field effect transistor (MOSFET) dosimeter coupled to a position-sensor, which deduces its 3D position in a magnetic field. To assess the feasibility of in vivo dosimetry based on the RADPOS system, different characteristics of the detector need to be investigated. Using a PMMA phantom, the positioning accuracy of the RADPOS system was quantified by comparing position readouts with the known position of the detector along the x and y-axes. RADPOS dose measurements were performed at various distances from a Nucletron{sup 192}Ir source in a PMMA phantom to evaluate the energy dependence of the MOSFET. A sensitivity analysis was performed by calculating the dose after varying (1) the position of the RADPOS detector to simulate organ motion and (2) the position of the first dwell position to simulate errors in delivery. The authors also performed an uncertainty analysis to determine the action level (AL) that should be used during in vivo dosimetry. Results: Positioning accuracy is found to be within 1 mm in the 1-10 cm range from the origin along the x-axis (away from the transmitter), meeting the requirements for in vivo dosimetry. Similar results are obtained for the other axes. The ALs are chosen to take into account the total uncertainty on the measurements. As a consequence for in vivo dosimetry, it is determined that the RADPOS sensor, if placed, for example, in the bladder Foley balloon, would detect a 2 mm motion of the bladder, at a 5% chance of a false positive, with an AL limit of 9% of the dose delivered. The authors found that source position errors, caused by, e.g., a wrong first dwell position, are more difficult to detect; indeed, with our single RADPOS detector, positioned in the bladder, dwell position errors below 5 mm and resulting in a dose error within 10%, could be detected in the tandem but not in the colpostats. A possible solution to improve error detection is to use multiple MOSFETs to obtain multiple dose values. Conclusions: In this study, the authors proposed a dosimetry procedure, based on the novel RADPOS system, to accurately determine the position of the radiation dosimeter with respect to the applicator. The authors found that it is possible to monitor the delivered dose in a point and compare it to the predetermined dose. This allows in principle the detection of problems such as bladder motion/filling or source mispositioning. Further clinical investigation is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗