At least 1,135 records · Page 63

U.S. Industrial and Commercial Motor System Market Assessment Report. Volume 3: Energy Saving Opportunity

This report seeks to inform the potential for motor systems to support decarbonization by estimating their potential energy, electricity cost, and CO 2 emissions reduction potential from adoption of proven energy efficiency actions and advanced technologies. This is the third and final report in a series of reports disseminating the findings of the U.S. Department of Energy’s (DOE’s) Motor System Market Assessment (MSMA). The MSMA and this report focus on polyphase motor systems greater than or equal to 1 horsepower (hp) in the industrial and commercial sectors. In the U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base (Volume 1 report), it was determined that these motor systems consume more than 1,000 terawatt-hours (TWh) annually. This equates to 29% of the U.S. electric grid load and results in 765 million metric tons (MMT) of CO 2 emissions and $166 billion in electricity costs. This report finds that substantial reductions to these energy, cost, and emissions impacts are possible, with three areas of significant opportunity being (1) improved load matching, (2) replacing older inefficient motors with more efficient motors, and (3) improving the condition of fluid (e.g., air, water, compressed air) distribution systems. A summary of the savings potential from these three opportunities placed within the context of the overall consumption for motor systems is illustrated in Figure ES 1 (industrial) and Figure ES 2 (commercial).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Distributed Grid Sensing Services (DGSS) platform: A scalable and decentralized sensor dissemination network

In this paper, a scalable, decentralized sensor-oriented, communication blueprint will be introduced. The proposed architecture has been specifically designed to support the mass deployment of sensors while enabling data consumers to access the underlying data streams using a distributed systems approach. With the proposed approach, sensors and data clients can be decoupled from the physical communication infrastructure and migrated into a modern, software-defined infrastructure ecosystem that can be configured to suit the end application’s demands. In its current iteration, the blueprint defines the interactions, processes, and expected outcomes that each individual component within the architecture must fulfill in order to support the overall ecosystem’s needs. Within this work, such assemble of services is referred the databus, and represents the heart of the Distributed Grid Sensing Services (DGSS) architecture, a multi-year project that aims to design, implement and test a dedicated sensor dissemination network that can support the needs of the extended grid state. It is our expectation, that the proposed blueprint presented in this paper will serve as a future guide to our implementation efforts

Sebastian Cardenas, David J.↗

Generalized Analytical Estimation of Sensitivity Matrices in Unbalanced Distribution Networks

Fast and accurate estimation of sensitivity matrices is significant for the enhancement of distribution system modeling and automation. Analytical estimations have mainly focused on voltage magnitude sensitivity to active/reactive power injections for unbalanced networks with Wye-connected loads and neglecting DERs' smart inverter functionality. Hence, this paper enhances the scope of analytical estimation of sensitivity matrices for unbalanced networks with 1- Φ, 2- Φ, and 3- Φ Delta/Wye-connected loads, DERs with smart inverter functionality, and substation/line step-voltage regulators (SVR). A composite bus model comprising of DER, Delta- and Wye-connected load is proposed to represent a generic distribution bus, which can be simplified to load, PV, or voltage-controlled bus as required. Furthermore, the proposed matrix-based analytical method consolidates voltage magnitude and angle sensitivity to active/reactive power injection and tap-position of all SVRs into a single algorithm. Extensive case studies on IEEE and EPRI networks show the accuracy and wide scope of the proposed algorithm compared to the existing benchmark method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Model-Free DER Dispatch Via Adaptive Voltage Sensitivity Estimation and Chance Constrained Programming

This paper proposes an online data-driven distributed energy resource management system (DERMS) for distribution system optimal DER dispatch as well as voltage regulation. Here, the key innovation is to leverage the Local Sensitivity Factor (LSF) for transforming the DER control into a computationally efficient linear programming (LP) problem. By taking real-time measurements, the estimation of LSF eliminates the need for an accurate distribution system model as well as full nodal load information, which is difficult to achieve in practice. A robust recursive least squares method is also developed to ensure the robust estimation of LSF, which is initialized using reasonable values from model-derived LSFs. This allows the system to adapt to changing operational conditions effectively. A scenario-based, chance-constrained framework is further employed to ensure voltage remains within acceptable limits in the presence of measurement and estimation uncertainties. Test results on a real-world, 759-node distribution network located in western Colorado, U.S., validate the effectiveness and robustness of the proposed control approach and demonstrate its superior performance as compared to alternative methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Radioactive Cleaning Robot

Here at Fermi National Accelerator Laboratory, particle accelerators are constantly running, giving off excess radioactive dust. This dust can be extremely harmful to people and the environment, posing numerous issues. The goal of this project is to conceptualize an automated cleaning solution. With this main goal in mind, the project started with a brainstorming session. The main concept relied on the use of a powder distributing system paired with a vacuum to easily attract and trap the dust. From this main concept, multiple sketches were produced, showing a robot with pieced-together systems. With the initial idea down, each subsystem could be brought further with the inner workings being sketched out. After sketches and proof of concept were polished, the next step was to begin 3D modeling, using NX, to bring life into the sketches. With every day came new ideas, modifying the previous sketches and models as necessary. Soon after the bigger structures were fleshed out, the focus could be shifted onto the less pressing subsystems. Adding a conveyor belt and spinning brush attachment to the powder hopper allowed for more even powder distribution. Along with that, the addition of spring-loaded brushes on the vacuum nozzle ensures constant dust agitation, improving overall functionality. A few other quality of life improvements, such as a removable dust reservoir with a ramp gave a push towards real life functionality. After considering the logistics of this robot functioning in real-life, pressure plates were provided to stop the robot from crashing into its surroundings. Having all of the individual models lead to an overall assembly. Making this robot programmable allowed for this project to meet the design requirements, providing a solution to the previous dilemma.

43 PARTICLE ACCELERATORS↗

Tri-Level Scheduling Model Considering Residential Demand Flexibility of Aggregated HVACs and EVs Under Distribution LMP

Residential loads, especially heating, ventilation and air conditioners (HVACs) and electric vehicles (EVs), have great potentials to provide demand flexibility which is an attribute of grid-interactive efficient buildings (GEB). Under this new paradigm, first, EV and HVAC aggregator models are developed in this paper to represent the fleet of GEBs, in which the aggregated parameters are obtained based on a new approach of data generation and least squares parameter estimation (DG-LSPE), which can deal with heterogeneous HVACs. Then, a tri-level bidding and dispatching framework is established based on competitive distribution operation with distribution locational marginal price (DLMP). Furthermore, the first two levels form a bilevel model to optimize the aggregators’ payment and to represent the interdependency between load aggregators and the distribution system operator (DSO) using DLMP, and the third level is to dispatch the optimal load aggregation to all residents by the proposed priority list-based demand dispatching algorithm. Finally, case studies on a modified IEEE 33-Bus system illustrate three main technical reasons of payment reduction due to demand flexibility: load shift, DLMP step changes, and power losses. They can be used as general guidelines for better decision-making for future planning and operation of demand response programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operating-Envelopes-Aware Decentralized Welfare Maximization for Energy Communities: Preprint

We propose an operating-envelope-aware, prosumer-centric, and efficient energy community that aggregates individual and shared community distributed energy resources downstream of a regulated distribution system operator's (DSO) net energy metering revenue meter. Due to the elevated risk of grid constraint violations and to ensure safe network operation, the DSO imposes dynamic export and import limits, known as dynamic operating envelopes, on end-users' revenue meters. Given the operating envelopes, the proposed community market mechanism maximizes the community's social welfare in a decentralized fashion while every community member abides by its own operating envelopes. We show that the proposed market mechanism conforms with the cost-causation principle and guarantees community members a surplus level no less than their maximum surplus when they autonomously face the DSO. Lastly, a numerical study is implemented to showcase and compare the community's welfare under the proposed operating-envelopes-aware mechanisms to others, including the welfare of customers under the DSO's regime.

distributed energy resources aggregation↗

Grid Resilience Plans: State Requirements, Utility Practices, and Utility Plan Template

As of June 2024, 14 states and one city require jurisdictional electric utilities to file resilience plans. Drawing on these requirements and filed plans, this report offers a standard template that states and utilities can consider to improve utility filings for grid resilience plans, either as part of a distribution system plan or as a separate filing. Key elements include a vulnerability assessment, description of proposed resilience programs, and projected costs and rate impacts. While many of these requirements and plans focus on extreme weather hazards, the template also can be used to address additional threats, including cyber and physical attacks and seismic events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Decentralized Market Mechanism for Energy Communities under Operating Envelopes

Here, we propose an operating envelopes (OEs) aware energy community market mechanism that dynamically charges/rewards its members based on two-part pricing. The OEs are imposed exogenously by a regulated distribution system operator (DSO) on the energy community's revenue meter and is subject to a generalized net energy metering (NEM) tariff design. By formulating the interaction of the community operator and its members as a Stackelberg game, we show that the proposed two-part pricing achieves a Nash equilibrium and maximizes the community's social welfare in a decentralized fashion while ensuring that the community's operation abides by the OEs. The market mechanism conforms with the cost-causation principle and guarantees community members a surplus level no less than their maximum surplus when they autonomously face the DSO. The dynamic and uniform community price is a monotonically decreasing function of the community's aggregate renewable generation. We also analyze the impact of exogenous parameters such as NEM rates and OEs on the value of joining the community. Lastly, through numerical studies, we showcase the community's welfare, and pricing, and compare its members' surplus to customers under the DSO's regime.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling DER visibility using a distributed dissemination network

The electrical grid is currently undergoing a series of rapid transformational changes that have resulted in the introduction of new actors and operational schemes that have fragmented the data and control planes. To help address the issue, this paper describes the implementation of a sensor-oriented, distributed data dissemination network that seeks to eliminate data silos. The implementation is based on the DGSS architecture previously described in [1]. The developed product seeks to facilitate the seamless integration of multi-operator, multi-origin, multi-domain sensor data by using a distributed systems approach. The proposed solution decouples the sensor’s data streams from the application-specific infrastructure and migrates them into a software-defined databus that can be configured to suit the end application’s demands. To further validate DGSS capabilities, a DER oriented use case has been developed.

Sensor Dissemination Networks, Enhanced DER visibi↗

Benefit-Cost Analysis for Utility-Facing Grid Modernization Investments: Trends, Challenges, and Considerations

In recent years, many electric utilities have submitted grid modernization plans for review by state public utility commissions. A central objective of these plans is to demonstrate that grid modernization investments will provide net benefits to customers, be reasonable and be in the public interest. The plans typically include some form of benefit-cost analysis, but the assumptions, methodologies and frameworks vary considerably between utilities. This report: -Describes utility-facing technologies and projects for modernizing distribution systems, including interdependencies of grid components -Highlights benefit-cost considerations related to grid modernization -Summarizes recent trends in benefit-cost analysis for grid modernization based on a review of 21 plans by U.S. electric utilities -Discusses challenges state public utility commissions face in reviewing utility plans and provides options for addressing challenges

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous Aerial Power Plant Inspection in GPS-denied Environments

Inspection of coal-fired power plants is frequently dangerous, includes difficult places to reach, and can turn expensive due to the downtimes and cost of inspection crew. Robotic systems have shown capabilities to address some of these issues, but most of the current robotic inspection technology in power plants is designed for specific components. Conversely, recent advances in machine vision have empowered aerial platforms for long-range, remotely-controlled, GPS-based inspections of industrial plants. This capability has led to wide spread utilization of aerial robots (commonly termed Drones, UVS or UAS) platforms for inspection in less challenging environments where both collision avoidance, and GPS reception are not significant issues. The challenge in adapting airborne technology for power plant inspection lies in internal structures and the complex network of piping, and distribution systems, which impose significant risks for collision and can hinder the reception and transmission of GPS signals. The current state of the art in aerial inspection technology within the energy sector is controlled via radio control, and utilizes GPS-based navigation, for inspection of large-scale plants such as offshore platforms and wind turbine parks. Nevertheless, close-range and autonomous inspection in the GPS-denied environments of power plants has not yet been achieved, as it requires precise guidance and navigation with real-time situational awareness and obstacle avoidance capabilities. This endeavor introduced the use of rotary wing flying robots, due to their station keeping and vertical take-off capabilities for power plant components inspection. To enable close quarter inspection two methods were used. One method uses the 3D CAD (Three-dimensional Computer-Aided Design) model of the asset to inspect to generate the UAV’s inspection path. To acquire, analyze and process the 3D model, first, the STL file is produced to obtain surface points and vectors normal to the surface. Later, by introducing other variables such as wall offset and a controlled trajectory between each outline and each subsequent layer, the flight path is generated. The proposed framework will generate a path that will pass as close as desired from the surface and navigate in intricate environments. A second method, use advanced manufacturing techniques such as CNC (Computer Numerical Control) and additive manufacturing. Once the inspection flight path is obtained, vision-based navigation systems are employed to have the UAV autonomously tracking the provided trajectory. Finally, Artificial Intelligence-enabled developments are in charge of detecting cracks and corrosion in structural components of power plants. The proposed methods are validated in simulations, laboratory and industrial setups, where it is shown that the developed systems acting together enable close-quarter autonomous aerial inspection and mapping in power plant assets. The system can be further improved by adding more sensors to navigate in different GPS-denied environments, with non-homogeneous lighting conditions, dust and in general situations where vision-based systems may fail.

01 COAL, LIGNITE, AND PEAT↗

Integration of a new Cryogenic Liquefier into the IB-1 Cryogenic Test Facility

The increase over the last years of the testing activities related to quantum systems, SRF cavities for the PIP-II and the LCLS-II projects, as well as superconducting magnets for the HL-LHC project and Fusion research activities, has required the addition of a new Helium cryogenic plant into the existing IB-1 Industrial Cryogenic Test Facility. The new cryogenic plant is composed of a cryogenic liquefier (Cold Box) able to provide up to 340 L/h, a 4 kL Dewar and two Mycom ® compressors providing up to 120 g/s. AL-AT (Air Liquide Advanced Technologies) has taken part of this project by designing and manufacturing the cryogenic liquefier. This new cryogenic plant is connected through a cryogenic distribution system to a 10 kL Dewar, which is part of the existing cryogenic test facility, itself composed of another Cold Box and a Sullair ® compressor. The new cryogenic plant has two main operating modes: one allows to transfer liquid helium at 1.7 bar between the two Dewars, the other allows to transfer supercritical Helium at 2 bar or more between the new Cold Box and the 10 kL Dewar. The entire industrial cryogenic facility is handled by a common Inventory Control System, composed of three control valves, and 9 tanks giving a total buffer volume of more than 1000 m3. This paper presents the technical features of the new Helium cryogenic plant, as well as the main results of the liquefier commissioning phase and details of the helium transfer between the two Dewars, making the connection between the cryogenic plants at the IB-1 Industrial Cryogenic Test Facility.

43 PARTICLE ACCELERATORS↗

Climate Vulnerability Assessment and Resilience Planning for Idaho National Laboratory

Idaho National Laboratory’s (INL’s) mission is to discover, demonstrate, and secure innovative nuclear energy solutions, other clean energy options, and critical infrastructure. This INL’s Climate Vulnerability Assessment and Resilience Plan (VARP) was developed to enable and sustain that mission while ensuring the viability of operations considering expected climate change impacts. The VARP was developed according to the narrative requirements from the “Vulnerability Assessment and Resilience Planning Guidance, Version 1.2” document issued in February 2022. A prescribed process was used to identify mission-critical systems and components, determine historical and expected climate impacts, and develop resilient solutions. Experts from across INL, including operations staff, researchers, and climate scientists supplied input to the process. Analyses of climate modeling sources revealed that under scenarios of higher and lower greenhouse gas emissions (Representative Concentration Pathway (RCP) 4.5 and RCP 8.5), INL anticipates an increase in climate hazards, including drought, heat waves, wildfire, and precipitation. Increased frequency and duration of climatic hazards forecasts high impacts on certain mission-critical asset and infrastructure types. Utilizing the VARP Risk Assessment Tool, projected high climate hazard impacts across multiple asset and infrastructure types at the INL include energy generation and distribution systems, Site buildings, specialized or mission-critical equipment, and transportation and fleet infrastructure. Some of these mission-critical asset and infrastructure types maintain high adaptive capacity to climatic changes; however, others may need additional adaptive capacity to withstand increased frequency and duration of climate hazards. INL identified close to 300 resilient solutions that were consolidated into 11 solution categories to be tracked in the Department of Energy Sustainability Dashboard. The identified solutions are a starting point for future project development and analysis. These data are intended to inform decision makers on climate issues and potential solutions across INL and associated communities. The VARP is not intended to be a budget tool or project decision document on its own, but rather one of many tools used by decision makers to establish resilient priorities. This initial document provides the framework and foundation to resilient solutions. In the coming years, each solution needs to be fully developed, costed, and prioritized based on mission-critical risk and funding priorities.

54 ENVIRONMENTAL SCIENCES↗

Robust Resilient Signal Reconstruction under Adversarial Attacks

We consider the problem of signal reconstruction for a system under sparse signal corruption by a malicious agent. The reconstruction problem follows the standard error coding problem that has been studied extensively in the literature. We include a new challenge of robust estimation of the attack support. The problem is then cast as a constrained optimization problem merging promising techniques in the area of deep learning and estimation theory. A pruning algorithm is developed to reduce the "false positive" uncertainty of data-driven attack localization results, thereby improving the probability of correct signal reconstruction. Sufficient conditions for the correct reconstruction and the associated reconstruction error bounds are obtained for both exact and inexact attack support estimation. Moreover, a simulation of a water distribution system is presented to validate the proposed techniques.

Robust, Signal reconstruction, Resilient estimator↗

Electrochemical deposition of amorphous aluminum oxides on lead pipes to prevent lead leaching into the drinking water

Over 5000 public drinking water systems in the US are out of compliance with the Lead and Copper Rule. Lead leaching from lead pipes is limited by the solubility of a naturally occurring scale. Changes in water quality may cause this scale to become more soluble, releasing lead into the drinking water. We propose a novel electrochemical method to prevent lead leaching from lead pipes. In this method, an aluminum wire and an alkaline phosphate electrolyte are inserted into the pipes. The pipes are then anodized for 2 h by using an external power supply, resulting in the electrodeposition of an insoluble aluminum oxide layer on top of the preexisting scale. This technology was tested on lead pipes from the EBMUD water distribution systems located in Berkeley, CA, using recirculating synthetic and actual tap water for 120 days. The untreated pipes leached an average of 23 ppb and 38 ppb of lead respectively, when using free chlorine and monochloramine as disinfection residuals. In contrast, the treated pipes leached 3 ppb and 5 ppb respectively. These results suggest that the proposed treatment has the potential to prevent lead leaching regardless of the disinfection residual and thus should be further explored in a field trial.

36 MATERIALS SCIENCE↗

End-Use Load Profiles for the U.S. Building Stock: Practical Guidance on Accessing and Using the Data

End-use load profiles (EULP), which quantify how and when energy is used, are critically important to utilities, public utility commissions, state energy offices, and other stakeholders. Applications of EULPs focus on understanding how efficiency, demand response, and other distributed energy resources are valued and used in R&D prioritization, utility resource and distribution system planning, and state and local energy planning and regulations. Consequently, high-quality EULPs are critical for widespread adoption of electrification, demand flexibility, and grid-interactive efficient buildings. For example, EULPs can be used to forecast energy savings in buildings or to identify energy using activities that can be shifted to different times of the day.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).