Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Digital signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

IAC control system analysis development

The MultiOptimal Differential Equation Language (MODEL) is described. It provides a means for generating numerical solutions to systems of differential equations using a digital computer. The notation of this language is similar to that usually used in describing physical systems by differential equations. Thus, the learning process is simplified, programming becomes easier, and debugging is more readily accomplished. Programs written in the MultiOptimal Differential Equation Language are machine translated into FORTRAN 4 code which is optimal in several respects. The interactive version of MODEL makes use of interactive system routines so that the user may observe the solution as it is being generated and interact with the program in a manner similar to that associated with analog simulation. The DISCOS-Control version of the MODEL simulation language is used to describe the control system for a plant which is modelled by the DISCOS program. DISCOS plant variables may be referenced in the control system description and all the sensor signals, coupling torques, momentum devices and external loads are automatically linked to the DISCOS plant model.

Frisch, H. P.↗

MIRAGE: The data acquisition, analysis, and display system

Developed for the NASA Johnson Space Center and Life Sciences Directorate by GE Government Services, the Microcomputer Integrated Real-time Acquisition Ground Equipment (MIRAGE) system is a portable ground support system for Spacelab life sciences experiments. The MIRAGE system can acquire digital or analog data. Digital data may be NRZ-formatted telemetry packets of packets from a network interface. Analog signal are digitized and stored in experimental packet format. Data packets from any acquisition source are archived to a disk as they are received. Meta-parameters are generated from the data packet parameters by applying mathematical and logical operators. Parameters are displayed in text and graphical form or output to analog devices. Experiment data packets may be retransmitted through the network interface. Data stream definition, experiment parameter format, parameter displays, and other variables are configured using spreadsheet database. A database can be developed to support virtually any data packet format. The user interface provides menu- and icon-driven program control. The MIRAGE system can be integrated with other workstations to perform a variety of functions. The generic capabilities, adaptability and ease of use make the MIRAGE a cost-effective solution to many experimental data processing requirements.

Rosser, Robert S.↗

Apparatus Characterizes Transient Voltages in Real Time

The figure shows a prototype of a relatively inexpensive electronic monitoring apparatus that measures and records selected parameters of lightning-induced transient voltages on communication and power cables. The selected parameters, listed below, are those most relevant to the ability of lightning-induced transients to damage electronic equipment. This apparatus bridges a gap between some traditional transient-voltage recorders that record complete waveforms and other traditional transient-voltage recorders that record only peak values: By recording the most relevant parameters and only those parameters this apparatus yields more useful information than does a traditional peak-value (only) recorder while imposing much smaller data-storage and data-transmission burdens than does a traditional complete-waveform recorder. Also, relative to a complete-waveform recorder, this apparatus is more reliable and can be built at lower cost because it contains fewer electronic components. The transients generated by sources other than lightning tend to have frequency components well below 1 MHz. Most commercial transient recorders can detect and record such transients, but cannot respond rapidly enough for recording lightning-induced transient voltage peaks, which can rise from 10 to 90 percent of maximum amplitude in a fraction of a microsecond. Moreover, commercial transient recorders cannot rearm themselves rapidly enough to respond to the multiple transients that occur within milliseconds of each other on some lightning strikes. One transient recorder, designed for Kennedy Space Center earlier [ Fast Transient-Voltage Recorder (KSC- 11991), NASA Tech Briefs, Vol. 23, No. 10, page 6a (October 1999)], is capable of sampling transient voltages at peak values up to 50 V in four channels at a rate of 20 MHz. That recorder contains a trigger circuit that continuously compares the amplitudes of the signals on four channels to a preset triggering threshold. When a trigger signal is received, a volatile memory is filled with data for a total time of 200 ms. After the data are transferred to nonvolatile memory, the recorder rearms itself within 400 ms to enable recording of subsequent transients. Unfortunately, the recorded data must be retrieved through a serial communication link. Depending on the amount of data recorded, the memory can be filled before retrieval is completed. Although large amounts of data are recorded and retrieved, only a small part of the information (the selected parameters) is usually required. The present transient-voltage recorder provides the required information, without incurring the overhead associated with the recording, storage, and retrieval of complete transient-waveform data. In operation, this apparatus processes transient voltage waveforms in real time to extract and record the selected parameters. An analog-to-digital converter that operates at a speed of as much as 100 mega-samples per second is used to sample a transient waveform. A real-time comparator and peak detector are implemented by use of fast field-programmable gate arrays.

Medelius, Pedro↗

Compression of echocardiographic scan line data using wavelet packet transform

An efficient compression strategy is indispensable for digital echocardiography. Previous work has suggested improved results utilizing wavelet transforms in the compression of 2D echocardiographic images. Set partitioning in hierarchical trees (SPIHT) was modified to compress echocardiographic scanline data based on the wavelet packet transform. A compression ratio of at least 94:1 resulted in preserved image quality.

Non-NASA Center↗

CHESS 2025: Waveform LiDAR data from NEON AOP surveys

This dataset provides Level 1 (L1) full-waveform light detection and ranging (LiDAR) data collected for the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS). These data were acquired to enable characterization of vegetation structure and other three-dimensional features of the land surface, and to evaluate structural changes that may have occurred between a prior LiDAR acquisition in 2018 and the 2025 overflight. Waveform LiDAR data can provide more detailed information about objects on the ground than discrete point clouds typically do, and they are often used for granular target segmentation and characterization of subcanopy vegetation. The data were acquired over three study domains in the Upper Gunnison river basin: the upper East River watershed (CRBU); Almont Triangle and Taylor Canyon (ALMO); and Upper Taylor River watershed (UPTA) between 2025-06-13 and 2025-07-15. LiDAR data were acquired using the Optech Galaxy Prime Airborne LiDAR Terrain Mapper onboard the National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP). These are the primary waveform LiDAR data delivered by NEON and are provided per flightline in compressed Pulsewaves format, an open-source binary file standard. A Pulsewaves object comprises a two files: a pulse (.pls) file, which stores the geographic origin, outgoing vector, and metadata for every laser pulse emitted by the scanner, and a wave file (.wvs), which stores the sequential amplitude samples of the outgoing pulse and the returning signals. The files are published here in their compressed forms (.plz, .wvz). All waveform data were processed following the theoretical workflow described in the NEON L0-to-L1 Waveform LiDAR Algorithm Theoretical Basis Document (Krause and Goulden 2022a); however, the Pulsewaves output format differs from a legacy format described in that document. Waveform amplitude samples are recorded at 1 nanosecond intervals. All coordinates are provided in meters. Horizontal coordinates are referenced in Universal Transverse Mercator (UTM) zone 13N and the World Geodetic System (WGS) 1984 ensemble datum. Elevations are referenced to Geoid12A. Waveform data for the UPTA survey area were collected without incident and the published records are complete. However, both the ALMO and CRBU collections experienced issues that resulted in incomplete data for those areas. On collection day 2018-06-16 a hardware failure caused the waveform digitizer to lose data from the eastern edge of the ALMO site (Figure 22). The waveform data for flightlines 2–20 could not be extracted from the digitizer, and the data proved unrecoverable. As a result, a portion of the site does not have coverage with waveform data. Although no hardware failure was observed during collection over the CRBU area, final waveform files generated by vendor software contained only ~25% of the expected number of return pulses. After discovery, NEON initiated troubleshooting with the vendor. The root cause of the data ablation had not been identified at the time of publication. Additional data will be published in an update to this package if further recovery proves successful. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

5G Enabled Energy Innovation: Advanced Wireless Networks for Science

Digital wireless communication has become a foundational technology for the nation. The U.S. Department of Energy’s Office of Science (DOE-SC) is the Nation’s largest supporter of basic research in the physical sciences discovering new materials, designing advanced microelectronics, and understanding the physics of radio frequency signaling. The expanding national rollout of a new fifth-generation (5G) mobile network, coupled with the torrent of scientific data generated by next-generation devices such as battery-powered Internet of Things (IoT) sensors, has created an urgent need to enhance cutting-edge wireless technology. Breakthroughs in the deployment, integration, security, and operational range of wireless networking can provide new scientific capabilities for the next decade - from autonomous mobile instruments for scientific user facilities to intelligent sensors networks distributed over thousands of kilometers to study environmental processes. To realize this promise, however, we must continue to drive innovations in computing, artificial intelligence (AI), advanced materials, high-speed networking, and microelectronics. In March 2020, the DOE-SC convened a workshop to identify the potential opportunities and explore the scientific challenges of advanced wireless technologies.

42 ENGINEERING↗

Digital autofocusing of a coded-aperture Laue diffraction microscope

To provide optimal depth resolution with a coded-aperture Laue diffraction microscope, an accurate position of the coded-aperture and its scanning geometry need to be known. However, finding the geometry by trial and error is a time-consuming and often challenging process because of the large number of parameters involved. In this paper, we propose an optimization approach to automate the focusing process after data is collected. Here we demonstrate the robustness and efficiency of the proposed approach with experimental data taken at a synchrotron facility.

47 OTHER INSTRUMENTATION↗

Noncoherent DTTLs for Symbol Synchronization

Noncoherent data-transition tracking loops (DTTLs) have been proposed for use as symbol synchronizers in digital communication receivers. [Communication- receiver subsystems that can perform their assigned functions in the absence of synchronization with the phases of their carrier signals ( carrier synchronization ) are denoted by the term noncoherent, while receiver subsystems that cannot function without carrier synchronization are said to be coherent. ] The proposal applies, more specifically, to receivers of binary phase-shift-keying (BPSK) signals generated by directly phase-modulating binary non-return-to-zero (NRZ) data streams onto carrier signals having known frequencies but unknown phases. The proposed noncoherent DTTLs would be modified versions of traditional DTTLs, which are coherent. The symbol-synchronization problem is essentially the problem of recovering symbol timing from a received signal. In the traditional, coherent approach to symbol synchronization, it is necessary to establish carrier synchronization in order to recover symbol timing. A traditional DTTL effects an iterative process in which it first generates an estimate of the carrier phase in the absence of symbol-synchronization information, then uses the carrier-phase estimate to obtain an estimate of the symbol-synchronization information, then feeds the symbol-synchronization estimate back to the carrier-phase-estimation subprocess. In a noncoherent symbol-synchronization process, there is no need for carrier synchronization and, hence, no need for iteration between carrier-synchronization and symbol- synchronization subprocesses. The proposed noncoherent symbolsynchronization process is justified theoretically by a mathematical derivation that starts from a maximum a posteriori (MAP) method of estimation of symbol timing utilized in traditional, coherent DTTLs. In that MAP method, one chooses the value of a variable of interest (in this case, the offset in the estimated symbol timing) that causes a likelihood function of symbol estimates over some number of symbol periods to assume a maximum value. In terms that are necessarily oversimplified to fit within the space available for this article, it can be said that the mathematical derivation involves a modified interpretation of the likelihood function that lends itself to noncoherent DTTLs. The proposal encompasses both linear and nonlinear noncoherent DTTLs. The performances of both have been computationally simulated; for comparison, the performances of linear and nonlinear coherent DTTLs have also been computationally simulated. The results of these simulations show that, among other things, the expected mean-square timing errors of coherent and noncoherent DTTLs are relatively insensitive to window width. The results also show that at high signal-to-noise ratios (SNRs), the performances of the noncoherent DTTLs approach those of their coherent counterparts at, while at low SNRs, the noncoherent DTTLs incur penalties of the order of 1.5 to 2 dB.

Simon, Marvin↗

Detector Control and Data Acquisition for the Wide-Field Infrared Survey Telescope (WFIRST) with a Custom ASIC

The Wide-Field Infrared Survey Telescope (WFIRST) will have the largest near-IR focal plane ever flown by NASA, a total of 18 4K x 4K devices. The project has adopted a system-level approach to detector control and data acquisition where 1) control and processing intelligence is pushed into components closer to the detector to maximize signal integrity, 2) functions are performed at the highest allowable temperatures, and 3) the electronics are designed to ensure that the intrinsic detector noise is the limiting factor for system performance. For WFIRST, the detector arrays operate at 90 to 100 K, the detector control and data acquisition functions are performed by a custom ASIC at 150 to 180 K, and the main data processing electronics are at the ambient temperature of the spacecraft, notionally approx.300 K. The new ASIC is the main interface between the cryogenic detectors and the warm instrument electronics. Its single-chip design provides basic clocking for most types of hybrid detectors with CMOS ROICs. It includes a flexible but simple-to-program sequencer, with the option of microprocessor control for more elaborate readout schemes that may be data-dependent. All analog biases, digital clocks, and analog-to-digital conversion functions are incorporated and are connected to the nearby detectors with a short cable that can provide thermal isolation. The interface to the warm electronics is simple and robust through multiple LVDS channels. It also includes features that support parallel operation of multiple ASICs to control detectors that may have more capability or requirements than can be supported by a single chip.

data acquisition↗

Multichannel Error Correction Code Decoder

NASA Lewis Research Center's Digital Systems Technology Branch has an ongoing program in modulation, coding, onboard processing, and switching. Recently, NASA completed a project to incorporate a time-shared decoder into the very-small-aperture terminal (VSAT) onboard-processing mesh architecture. The primary goal was to demonstrate a time-shared decoder for a regenerative satellite that uses asynchronous, frequency-division multiple access (FDMA) uplink channels, thereby identifying hardware and power requirements and fault-tolerant issues that would have to be addressed in a operational system. A secondary goal was to integrate and test, in a system environment, two NASA-sponsored, proof-of-concept hardware deliverables: the Harris Corp. high-speed Bose Chaudhuri-Hocquenghem (BCH) codec and the TRW multichannel demultiplexer/demodulator (MCDD). A beneficial byproduct of this project was the development of flexible, multichannel-uplink signal-generation equipment.

Source record↗

Direct adaptive control of a PUMA 560 industrial robot

The implementation and experimental validation of a new direct adaptive control scheme on a PUMA 560 industrial robot is described. The testbed facility consists of a Unimation PUMA 560 six-jointed robot and controller, and a DEC MicroVAX II computer which hosts the Robot Control C Library software. The control algorithm is implemented on the MicroVAX which acts as a digital controller for the PUMA robot, and the Unimation controller is effectively bypassed and used merely as an I/O device to interface the MicroVAX to the joint motors. The control algorithm for each robot joint consists of an auxiliary signal generated by a constant-gain Proportional plus Integral plus Derivative (PID) controller, and an adaptive position-velocity (PD) feedback controller with adjustable gains. The adaptive independent joint controllers compensate for the inter-joint couplings and achieve accurate trajectory tracking without the need for the complex dynamic model and parameter values of the robot. Extensive experimental results on PUMA joint control are presented to confirm the feasibility of the proposed scheme, in spite of strong interactions between joint motions. Experimental results validate the capabilities of the proposed control scheme. The control scheme is extremely simple and computationally very fast for concurrent processing with high sampling rates.

Seraji, Homayoun↗

Development of a Multi-Channel, High Frequency QRS Electrocardiograph

With the advent of the ISS era and the potential requirement for increased cardiovascular monitoring of crewmembers during extended EVAs, NASA flight surgeons would stand to benefit from an evolving technology that allows for a more rapid diagnosis of myocardial ischemia compared to standard electrocardiography. Similarly, during the astronaut selection process, NASA flight surgeons and other physicians would also stand to benefit from a completely noninvasive technology that, either at rest or during maximal exercise tests, is more sensitive than standard ECG in identifying the presence of ischemia. Perhaps most importantly, practicing cardiologists and emergency medicine physicians could greatly benefit from such a device as it could augment (or even replace) standard electrocardiography in settings where the rapid diagnosis of myocardial ischemia (or the lack thereof) is required for proper clinical decision-making. A multi-channel, high-frequency QRS electrocardiograph is currently under development in the Life Sciences Research Laboratories at JSC. Specifically the project consisted of writing software code, some of which contained specially-designed digital filters, which will be incorporated into an existing commercial software program that is already designed to collect, plot and analyze conventional 12-lead ECG signals on a desktop, portable or palm PC. The software will derive the high-frequency QRS signals, which will be analyzed (in numerous ways) and plotted alongside of the conventional ECG signals, giving the PC-viewing clinician advanced diagnostic information that has never been available previously in all 12 ECG leads simultaneously. After the hardware and software for the advanced digital ECG monitor have been fully integrated, plans are to use the monitor to begin clinical studies both on healthy subjects and on patients with known coronary artery disease in both the outpatient and hospital settings. The ultimate goal is to get the technology out into the clinical world, where it has the potential to save lives.

DePalma, Jude L.↗

Design of an Auto-zeroed, Differential, Organic Thin-film Field-effect Transistor Amplifier for Sensor Applications

Organic strain gauge and other sensors require high-gain, precision dc amplification to process their low-level output signals. Ideally, amplifiers would be fabricated using organic thin-film field-effect transistors (OTFT's) adjacent to the sensors. However, OTFT amplifiers exhibit low gain and high input-referred dc offsets that must be effectively managed. This paper presents a four-stage, cascaded differential OTFT amplifier utilizing switched capacitor auto-zeroing. Each stage provides a nominal voltage gain of four through a differential pair driving low-impedance active loads, which provide common-mode output voltage control. p-type pentacence OTFT's are used for the amplifier devices and auto-zero switches. Simulations indicate the amplifier provides a nominal voltage gain of 280 V/V and effectively amplifies a 1-mV dc signal in the presence of 500-mV amplifier input-referred dc offset voltages. Future work could include the addition of digital gain calibration and offset correction of residual offsets associated with charge injection imbalance in the differential circuits.

large-area electronics↗

Hemispherical Field-of-View Above-Water Surface Imager for Submarines

A document discusses solutions to the problem of submarines having to rise above water to detect airplanes in the general vicinity. Two solutions are provided, in which a sensor is located just under the water surface, and at a few to tens of meter depth under the water surface. The first option is a Fish Eye Lens (FEL) digital-camera combination, situated just under the water surface that will have near-full- hemisphere (360 azimuth and 90 elevation) field of view for detecting objects on the water surface. This sensor can provide a three-dimensional picture of the airspace both in the marine and in the land environment. The FEL is coupled to a camera and can continuously look at the entire sky above it. The camera can have an Active Pixel Sensor (APS) focal plane array that allows logic circuitry to be built directly in the sensor. The logic circuitry allows data processing to occur on the sensor head without the need for any other external electronics. In the second option, a single-photon sensitive (photon counting) detector-array is used at depth, without the need for any optics in front of it, since at this location, optical signals are scattered and arrive at a wide (tens of degrees) range of angles. Beam scattering through clouds and seawater effectively negates optical imaging at depths below a few meters under cloudy or turbulent conditions. Under those conditions, maximum collection efficiency can be achieved by using a non-imaging photon-counting detector behind narrowband filters. In either case, signals from these sensors may be fused and correlated or decorrelated with other sensor data to get an accurate picture of the object(s) above the submarine. These devices can complement traditional submarine periscopes that have a limited field of view in the elevation direction. Also, these techniques circumvent the need for exposing the entire submarine or its periscopes to the outside environment.

Hemmati, Hamid↗

Cryogenic Front-End ASICs for Low-Noise Readout of Charge Signals

This paper presents design details and measurement results of LArASIC, a front-end application specific integrated circuit (ASIC) designed for low-noise readout of charge signals generated in neutrino study experiments within liquid argon time projection chambers. LArASIC comprises of 16-channels of programmable charge amplification and pulse shaping stages that provide a voltage readout proportional to the input charge and was optimized for operation at liquid argon temperature, i.e., 89 K. The chip was fabricated in a 180 nm CMOS process. Measurements at liquid nitrogen temperature, i.e., 77 K, indicate that the channel outputs have high linearity (INL < 0.1%) within the operating range, an equivalent noise charge of 534 electrons for a peaking time of 1 µs and a detector capacitance of 150 pF, and a worst-case inter-channel cross-talk of 0.35%. The paper also presents design choices made in the process of migrating LArASIC to CHARMS, an ASIC to be fabricated in a 65 nm process that includes all features provided by LArASIC, along with additional digital programmability for improved robustness and flexibility. CHARMS is intended for use in future high-energy physics experiments that require high-resolution charge or light readout with shorter pulse peaking times.

47 OTHER INSTRUMENTATION↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System Concepts for the Advanced Post-TRMM Rainfall Profiling Radars

Global rainfall is the primary distributor of latent heat through atmospheric circulation. The recently launched Tropical Rainfall Measuring Mission satellite is dedicated to advance our understanding of tropical precipitation patterns and their implications on global climate and its change. The Precipitation Radar (PR) aboard the satellite is the first radar ever flown in space and has provided. exciting, new data on the 3-D rain structures for a variety of scientific uses. However, due to the limited mission lifetime and the dynamical nature of precipitation, the TRMM PR data acquired cannot address all the issues associated with precipitation, its related processes, and the long-term climate variability. In fact, a number of new post-TRMM mission concepts have emerged in response to the recent NASA's request for new ideas on Earth science missions at the post 2002 era. This paper will discuss the system concepts for two advanced, spaceborne rainfall profiling radars. In the first portion of this paper, we will present a system concept for a second-generation spaceborne precipitation radar for operations at the Low Earth Orbit (LEO). The key PR-2 electronics system will possess the following capabilities: (1) A 13.6/35 GHz dual frequency radar electronics that has Doppler and dual-polarization capabilities. (2) A large but light weight, dual-frequency, wide-swath scanning, deployable antenna. (3) Digital chirp generation and the corresponding on-board pulse compression scheme. This will allow a significant improvement on rain signal detection without using the traditional, high-peak-power transmitters and without sacrificing the range resolution. (4) Radar electronics and algorithm to adaptively scan the antenna so that more time can be spent to observe rain rather than clear air. and (5) Built-in flexibility on the radar parameters and timing control such that the same radar can be used by different future rain missions. This will help to reduce the overall instrument development costs. In the second portion of this paper, we will present a system concept for a geostationary rainfall monitoring radar for operations at the geosynchronous Earth Orbit (GEO). In particular, the science requirements, the observational strategy, the instrument design, and the required technologies will be discussed.

Im, Eastwood↗

Statistical properties of filtered pseudorandom digital sequences formed from the sum of maximum-length sequences

The statistics of filtered pseudorandom digital sequences called hybrid-sum sequences, formed from the modulo-two sum of several maximum-length sequences, are analyzed. The results indicate that a relation exists between the statistics of the filtered sequence and the characteristic polynomials of the component maximum length sequences. An analysis procedure is developed for identifying a large group of sequences with good statistical properties for applications requiring the generation of analog pseudorandom noise. By use of the analysis approach, the filtering process is approximated by the convolution of the sequence with a sum of unit step functions. A parameter reflecting the overall statistical properties of filtered pseudorandom sequences is derived. This parameter is called the statistical quality factor. A computer algorithm to calculate the statistical quality factor for the filtered sequences is presented, and the results for two examples of sequence combinations are included. The analysis reveals that the statistics of the signals generated with the hybrid-sum generator are potentially superior to the statistics of signals generated with maximum-length generators. Furthermore, fewer calculations are required to evaluate the statistics of a large group of hybrid-sum generators than are required to evaluate the statistics of the same size group of approximately equivalent maximum-length sequences.

Wallace, G. R.↗