Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,119 records · Page 63

Realizing crack-free high-aluminum-mole-fraction AlGaN on patterned GaN beyond the critical layer thickness

Wide-bandgap III-nitride heterostructures are required for a variety of device applications. However, this alloy system has a large lattice constant and thermal expansion coefficient mismatch that limits the alloy composition and layer thickness for many heteroepitaxial device structures. Consequently, various methods have been devised to allow the heteroepitaxial growth of AlInGaN heterostructures to accommodate this inherent strain. In this work, we describe a non-planar-growth approach that enables the deposition of crack-free high-Al-mole-fraction Al x Ga 1-x N on patterned GaN/sapphire templates and bulk GaN substrates with large-area mesas. We have studied the effects of the patterned mesa width, the mesa etch depth, and the gap between the mesas on the heteroepitaxy of Al x Ga 1-x N superlattices with an average Al molar fraction 0.11 < x¯ < 0.21 and non-planar overgrowth growth thicknesses up to 3.5 μm. Similar to the planar growth approach, increasing the thickness and Al mole fraction of the Al x Ga 1-x N superlattices leads to surface cracking when exceeding the critical layer thickness. However, limiting the mesa dimension in one direction enables strain mitigation and drastically increases the critical layer thickness. Additionally, larger etch depths of the mesas increase the Al alloy composition and thickness for crack-free AlGaN heteroepitaxy whereas the gap in between the mesas seems to have no crucial influence. We demonstrate that the Al alloy composition and layer thicknesses of such heterostructures can be increased far beyond the critical layer thickness for planar growth and demonstrate the growth of a crack-free full AlxGa 1-x N/GaN quantum-well laser heterostructure designed for operation at ~370 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural, magnetic and electrical transport properties of YMnAl

The intermetallic compound YMnAl, crystallizing in the cubic C-15 (MgCu 2 -type) structure, was prepared using arc-melting and annealing. Rietveld refinement of the XRD pattern yields a lattice parameter of a = 7.816(1) Å⁠. The system exhibits antiferromagnetic order with a transition temperature of approximately 38 K, along with indications of a spin-glass–like phase. The effective magnetic moment, estimated from Curie–Weiss fitting of the susceptibility versus temperature curve, is 6.06 μ B /f.u. and the Curie–Weiss temperature of −79 K confirming the antiferromagnetic nature. Isothermal magnetization measurements below and above the Néel temperature show no saturation, with a maximum magnetization of 0.09 μ B /f.u observed at an applied field of 9 T. The temperature dependence of resistivity exhibits a negative temperature coefficient, characteristic of dirty metals. Hall effect measurements indicate the absence of an anomalous Hall contribution. The Hall coefficient RH, carrier concentration n, and mobility μ estimated from R XY (H) are -1.05×10 -8 m 3 /C, 5.92×10 26 m -3 and 1.05×10 -3 m 2 /V.s, respectively. Our first-principles calculations indicate that YMnAl in the orthorhombic (Imma) structure has the lowest energy; however, the substitutional disorder occurring during experimental synthesis may favor the formation of the cubic Laves phase.

Crystallography↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC)

METRIC is a robotic science laboratory that can determine the mineralogy, elemental chemistry, micromorphology, and thermophysical properties of planetary regolith. The METRIC suite comprises METRIC XRD/F, an X-ray diffraction/X-ray fluorescence instrument that can determine the mineralogy and elemental chemistry of regolith samples; METRIC XCT, a micro X-ray computed tomography instrument that can be used to evaluate grain/crystallite sizes and textures; METRIC IRS, an imaging spectrometer mounted on a rover that can determine mineralogy and thermophysical properties at the landing site; and a pneumatic sample collection, processing, distribution system developed by Honeybee Robotics. The payload elements could be deployed on a static lander or a rover. Data returned from the METRIC payload would inform origin, formation, and evolution of rocky planetary bodies. METRIC XRD/F draws on heritage from the CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover [1], with a few important improvements. Like CheMin, METRIC XRD/F operates in transmission geometry and uses piezoelectric actuators on sample cells in a tuning fork geometry to induce convective grain motion of the regolith to create a randomly oriented powder. MSL CheMin uses an energy-sensitive CCD to collect XRD patterns and XRF spectra simultaneously from the same sample cell, resulting in qualitative XRF data. METRIC XRD/F uses two different sample cells, one optimized for XRD and one optimized for XRF, and a silicon drift detector to detect fluoresced X-rays. This improvement to the XRF capabilities provides quantitative geochemical data of major elements down to Z = 11 and allows for the detection of minor and trace elements that are critical for evaluating geologic evolution of the Moon (e.g., P and Th). Modest improvements to the XRD geometry and hardware allow for better angular resolution and the ability to distinguish between members of the pyroxene group. METRIC XCT uses the same geometry and much of the same hardware as METRIC XRD/F, where a CCD would capture images of a regolith sample in a 3 mm diameter sample tube that is rotated 360° in steps <1°. Image brightness can be used to infer compositional data, where brighter materials indicate a higher Z, much like scanning electron microscopy. Data from METRIC XCT complement those from METRIC XRD/F. Particle size, shape, and texture can provide petrologic and provenance information, whereas vesicle size and morphology in volcanic or impact melt lithologies can inform cooling rates. METRIC IRS is a hyperspectral thermal imager that can be mounted to a lander or rover to provide mineralogical data from the broader landing site and help determine whether the samples analyzed by METRIC XRD/F and XCT are representative. The METRIC IRS spectral range (8–14 μm) and resolution (10.8 cm-1) allow for quantitative mineralogy from modelling Reststrahlen bands of major rock-forming minerals (e.g., silicates, phosphates). Radiance cubes can be processed and modelled with an onboard high-performance computer to determine mineral abundances of plagioclase, high-Ca pyroxene, pigeonite, orthopyroxene, olivine, and glass. Regolith samples can be acquired, processed, and delivered to the X-ray instruments via multiple sample handling systems, but the pneumatic sampling systems developed by Honeybee Robotics [e.g., 2] are best suited for relatively low-cost missions that are being competed for the Moon (e.g., NASA’s Payloads and Research Investigations for the Surface of the Moon program). There are pneumatic sampling systems that collect surface material and other systems that pneumatically drill up to ~1 m below the surface, providing material that has not been space weathered and has not been affected by the lander’s exhaust. [1] Blake, D. F., Vaniman, D., Achilles, C., Anderson, R., Bish, D., et al. (2012). Space Sci. Rev. 170, 341-478. https://doi.org/10.1007/s11214-012-9905-1. [2] Zacny, K., Betts, B., Hedlund, M., Long, P., Gramlich, M., Tura, K., Chu, P., Jacob, A., Garcia, A. (2014). IEEE Aerospace Conference, 3-7 March 2014, Big Sky, MT, U.S.A.

X-ray diffraction↗