Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection and Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Here, we characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a 137 Cs source for energy calibration and a 252 Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is (30.2 ± 0.9)%, which is almost twice that of the PMT-based array, which we measure to be (16.9 ± 0.1)%.

47 OTHER INSTRUMENTATION↗

Improved Detection System Description and New Method for Accurate Calibration of Micro-Channel Plate Based Instruments and Its Use in the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

The Fast Plasma Investigation (FPI) on NASAs Magnetospheric MultiScale (MMS) mission employs 16 Dual Electron Spectrometers (DESs) and 16 Dual Ion Spectrometers (DISs) with 4 of each type on each of 4 spacecraft to enable fast (30 ms for electrons; 150 ms for ions) and spatially differentiated measurements of the full 3D particle velocity distributions. This approach presents a new and challenging aspect to the calibration and operation of these instruments on ground and in flight. The response uniformity, the reliability of their calibration and the approach to handling any temporal evolution of these calibrated characteristics all assume enhanced importance in this application, where we attempt to understand the meaning of particle distributions within the ion and electron diffusion regions of magnetically reconnecting plasmas. Traditionally, the micro-channel plate (MCP) based detection systems for electrostatic particle spectrometers have been calibrated using the plateau curve technique. In this, a fixed detection threshold is set. The detection system count rate is then measured as a function of MCP voltage to determine the MCP voltage that ensures the count rate has reached a constant value independent of further variation in the MCP voltage. This is achieved when most of the MCP pulse height distribution (PHD) is located at higher values (larger pulses) than the detection system discrimination threshold. This method is adequate in single-channel detection systems and in multi-channel detection systems with very low crosstalk between channels. However, in dense multi-channel systems, it can be inadequate. Furthermore, it fails to fully describe the behavior of the detection system and individually characterize each of its fundamental parameters. To improve this situation, we have developed a detailed phenomenological description of the detection system, its behavior and its signal, crosstalk and noise sources. Based on this, we have devised a new detection system calibration method that enables accurate and repeatable measurement and calibration of MCP gain, MCP efficiency, signal loss due to variation in gain and efficiency, crosstalk from effects both above and below the MCP, noise margin, and stability margin in one single measurement. More precise calibration is highly desirable as the instruments will produce higher quality raw data that will require less post-acquisition data correction using results from in-flight pitch angle distribution measurements and ground calibration measurements. The detection system description and the fundamental concepts of this new calibration method, named threshold scan, will be presented. It will be shown how to derive all the individual detection system parameters and how to choose the optimum detection system operating point. This new method has been successfully applied to achieve a highly accurate calibration of the DESs and DISs of the MMS mission. The practical application of the method will be presented together with the achieved calibration results and their significance. Finally, it will be shown that, with further detailed modeling, this method can be extended for use in flight to achieve and maintain a highly accurate detection system calibration across a large number of instruments during the mission.

detection system↗

Characterization of inexpensive metal oxide sensor performance for trace methane detection

Abstract. Methane, a major contributor to climate change, is emitted by a variety of natural and anthropogenic sources. Commercially available lab-grade instruments for sensing trace methane are expensive, and previous efforts to develop inexpensive, field-deployable trace methane sensors have had mixed results. Industrial and commercial metal oxide (MOx) methane sensors, which are intended for leak detection and safety monitoring, can potentially be repurposed and adapted for low-concentration sensing. As an initial step towards developing a low-cost sensing system, we characterize the performance of five off-the-shelf MOx sensors for 2–10 ppm methane detection in a laboratory setting (Figaro Engineering TGS2600, TGS2602, TGS2611-C00, TGS2611-E00, and Henan Hanwei Electronics MQ4). We identify TGS2611-C00, TGS2611-E00, and MQ4 as promising for trace methane sensing but show that variations in ambient humidity and temperature pose a challenge for the sensors in this application.

54 ENVIRONMENTAL SCIENCES↗

Sensor systems for the Altair Lunar Lander:

The Altair Lunar Lander will enable astronauts to learn to live and work on the moon for extended periods of time, providing the experience needed to expand human exploration farther into the solar system. My overriding recommendation: Use independent and complementary [sometimes referred to as 'orthogonal'] techniques to disambiguate confounding/interfering signals. E.g.: a mass spectrometer ['MS'], which currently serves as a Majority Constituent Analyzer ['MCA'] can be very valuable in detecting the presence of a gaseous specie, so long as it falls on a mass-to-charge ratio ['m/z'] that is not already occupied by a majority constituent of cabin air. Consider the toxic gas, CO. Both N{sub 2} and CO have parent peaks of m/z = 28, and CO{sub 2} has a fragment peak at m/z = 28 [and at 16 and 12], so the N{sub 2} and CO{sub 2} m/z=28 signals could mask low, but potentially-dangerous levels of CO. However there are numerous surface-sensitive CO detectors, as well as tunable-diode-laser-based CO sensors that could provide independent monitoring of CO. Also, by appending a gas chromatograph ['GC'] as the front-end sample processer, prior to the inlet of the MS, one can rely upon the GC to separate CO from N{sub 2} and CO{sub 2}, providing the crew with another CO monitor. If the Altair Lunar Lander is able to include a Raman-based MCA for N{sub 2}, O{sub 2}, H{sub 2}O, and CO{sub 2}, then each type of MCA would have cross-references, providing more confidence in the ongoing performance of each technique, and decreasing the risk that one instrument might fail to perform properly, without being noticed. See, also Dr. Pete Snyder's work, which states 'An orthogonal technologies sensor system appears to be attractive for a high confidence detection of presence and temporal characterization of bioaerosols.' Another recommendation: Use data fusion for event detection to decrease uncertainty: tie together the outputs from multiple sensing modalities - eNose, solid-state sensors, GC-IMS, GC-MS - via nonlinear algorithms, such as an 'artificial neural net.' MA Ryan at the JPL and Henry Abarbanel at UCSD are possible candidates to implement such an approach.

42 ENGINEERING↗

DMTN-080: Coaddition Artifact Rejection and CompareWarp

LSST images will be contaminated with transient artifacts, such as optical ghosts, satellite trails, and cosmic rays, and with transient astronomical sources, such as asteroid ephemerides. We developed and tested an algorithm to find and reject these artifacts during coaddition, in order to produce clean coadds to be used for deep detection and preliminary object characterization. This algorithm, CompareWarpAssembleCoadd, uses the time-series of PSF-matched warped images to identify transient artifacts. It detects artifact candidates on the image differences between each PSF-matched warp and a static sky model. These artifact candidates include both true transient artifacts and difference-image false positives such as difficult-subtract-sources and variable sources such as stars and quasars. We use the feature that true transients appear at a given position in the difference images in only a small fraction (configurable) of visits, whereas variable sources and difficult-to-subtract sources appear in most difference images. In this report, we present a description of the method and an evaluation using Hyper SuprimeCam PDR1 data.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal QNDE detection of airframe disbonds

Thermographic characterization of aircraft bonded lap joints offers a quick noncontacting technique to acquire information for structural integrity assessment. This paper discusses recent research to optimize the technique and determine the limits of its applicability. The temperature of the outer surface of the lap joint is increased by the application of heat flux from either flash or quartz lamp heaters. The time dependence of the surface temperature of the lap joint is imaged radiometrically. Measurements are presented for a range of specimens, ranging from samples fabricated with well characterized disbonds to actual aircraft. A technique for processing these images to enhance the contrast between bonded and disbonded regions of the lap joint is presented. Numerical models of the technique simulate the procedure. These simulations provide a cost efficient method for optimizing the technique by varying parameters such as the time for application of heat. These simulations facilitate the definition of parameters difficult to determine experimentally, such as the minimum air gap required for a disbond to be detected. Good agreement between measurements and these simulations is found.

Aging Aircraft↗

Remote Detection of Radioactive Materials Using Long Wavelength Infrared Laser Driven Avalanche Breakdown [Slides]

The yearly goals of the "Remote Detection of Radioactive Materials Using Long Wavelength Infrared Laser Driven Avalanche Breakdown" experiment are broken into two parts. Year 1: Perform proof-of-concept scaling experiments for detection of radioactive materials at 10m standoff distance, characterizing avalanche breakdowns with the 9.2μm long pulse beam line and optimizing diagnostics. Years 2-3: Extend technique to 30m detection distance, characterizing the effect of long propagation paths on sensitivity, improving diagnostic sensitivity and resolution, and characterizing the effects of turbulence and aerosols.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pulsed CO2 characterization for lidar use

An account is given of a scaled functional testbed laser for space-qualified coherent-detection lidar applications which employs a CO2 laser. This laser has undergone modification and characterization for inherent performance capabilities as a model of coherent detection. While characterization results show good overall performance that is in agreement with theoretical predictions, frequency-stability and pulse-length limitations severely limit the laser's use in coherent detection.

Jaenisch, Holger M.↗

Electronic Characterization of Lithographically Patterned Microcoils for High Sensitivity NMR Detection

Nuclear magnetic resonance (NMR) offers a non-destructive, powerful, structure-specific analytical method for the identification of chemical and biological systems. The use of radio frequency (RF) microcoils has been shown to increase the sensitivity in mass limited samples. Recent advances in micro-receiver technology have further demonstrated a substantial increase in mass sensitivity [1]. Lithographic methods for producing solenoid microcoils possess a level of flexibility and reproducibility that exceeds previous production methods, such as hand winding microcoils. This paper presents electrical characterizations of RF microcoils produced by a unique laser lithography system that can pattern three dimensional surfaces and compares calculated and experimental results to those for wire wound RF microcoils. We show that existing optimization conditions for RF coil design still hold true for RF microcoils produced by lithography. Current lithographic microcoils show somewhat inferior performance to wire wound RF microcoils due to limitations in the existing electroplating technique. In principle, however, when the pitch of the RF microcoil is less than 100 {micro}m lithographic coils should show comparable performance to wire wound coils. In the cases of larger pitch, wire cross sections can be significantly larger and resistances lower than microfabricated conductors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Humanized Mouse Model of Organophosphate Poisoning and Detection of Countermeasures via MALDI-MSI

Organophosphoate (OP) chemicals are known to inhibit the enzyme acetylcholinesterase (AChE). Studying OP poisoning is difficult because common small animal research models have serum carboxylesterase, which contributes to animals’ resistance to OP poisoning. Historically, guinea pigs have been used for this research; however, a novel genetically modified mouse strain (KIKO) was developed with nonfunctional serum carboxylase (Es1 KO) and an altered acetylcholinesterase (AChE) gene, which expresses the amino acid sequence of the human form of the same protein (AChE KI). KIKO mice were injected with 1xLD50 of an OP nerve agent or vehicle control with or without atropine. After one to three minutes, animals were injected with 35 mg/kg of the currently fielded Reactivator countermeasure for OP poisoning. Postmortem brains were imaged on a Bruker RapifleX ToF/ToF instrument. Data confirmed the presence of increased acetylcholine in OP-exposed animals, regardless of treatment or atropine status. More interestingly, we detected a small amount of Reactivator within the brain of both exposed and unexposed animals; it is currently debated if reactivators can cross the blood–brain barrier. Further, we were able to simultaneously image acetylcholine, the primary affected neurotransmitter, as well as determine the location of both Reactivator and acetylcholine in the brain. This study, which utilized sensitive MALDI-MSI methods, characterized KIKO mice as a functional model for OP countermeasure development.

2-PAM↗

A Scalable Parallel Algorithm for Large-Scale Protein Sequence Homology Detection

Protein sequence homology detection is a fundamental problem in computational molecular biology, with a pervasive application in nearly all analyses that aim to structurally and functionally characterize protein molecules. While detecting homology between two protein sequences is computationally inexpensive, detecting pairwise homology at a large-scale becomes prohibitive, requiring millions of CPU hours. Yet, there is currently no efficient method available to parallelize this kernel. In this paper, we present the key characteristics that make this problem particularly hard to parallelize, and then propose a new parallel algorithm that is suited for large-scale protein sequence data. Our method, called pGraph, is designed using a hierarchical multiple-master multiple-worker model, where the processor space is partitioned into subgroups and the hierarchy helps in ensuring the workload is load balanced fashion despite the inherent irregularity that may originate in the input. Experimental evaluation demonstrates that our method scales linearly on all input sizes tested (up to 640K sequences) on a 1,024 node supercomputer. In addition to demonstrating strong scaling, we present an extensive study of the various components of the system and related parametric studies.

59 BASIC BIOLOGICAL SCIENCES↗

A TALE OF THREE GALAXIES: ANOMALOUS DUST PROPERTIES IN IRAS F10398+1455, IRAS F21013–0739, AND SDSS J0808+3948

On a galactic scale, the 9.7 μm silicate emission is usually only seen in type 1 active galactic nuclei (AGNs). They usually also display a flat emission continuum at ∼5-8 μm and the absence of polycyclic aromatic hydrocarbon (PAH) emission bands. In contrast, starburst galaxies, luminous infrared (IR) galaxies, and ultraluminous IR galaxies exhibit a red 5-8 μm emission continuum, strong 9.7 μm and 18 μm silicate absorption features, and strong PAH emission bands. Here, we report the detection of anomalous dust properties by the Spitzer/Infrared Spectrograph in three galaxies (IRAS F10398+1455, IRAS F21013-0739, and SDSS J0808+3948) which are characterized by the simultaneous detection of a red 5-8 μm emission continuum, the 9.7 and 18 μm silicate emission features, as well as strong PAH emission bands. These apparently contradictory dust IR emission properties are discussed in terms of iron-poor silicate composition, carbon dust deficit, small grain size, and low dust temperature in the young AGN phase of these three galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of Gamma-ray Production from Neutron-induced Activity on Spacecraft for DIORAMA

The Distributed Infrastructure Offering Real{Time Access to Modeling and Analysis (DIORAMA) software provides performance modeling capabilities of the United States Nuclear Detonation Detection System (USNDS) with a focus on the characterization of Space{Based Nuclear Detonation Detection (SNDD) instrument performance [1]. A study was conducted investigating the neutron activation on spacecraft caused by cosmic{ray and trapped proton{induced spallation, and by direct irradiation from hypothetical nuclear detonations as a background component to be incorporated into DIORAMA. The neutron activation background study amasses a database of pre-calculated Monte Carlo data that reflects the delayed gamma-ray production from activated nuclei as a function of incident cosmic or neutron flux, incident energy, material volume, etc. CINDER2008 coupled with MCNPX and the Activation Analysis Tools in the Activation in Accelerator Radiation Environments (AARE) distribution along with a suite of Python scripts are used to calculate and assemble the Monte Carlo database [2{6]. The neutron activation background study improves the fidelity of DIORAMA by providing the neutron-induced activation component to the background of the instruments on-board the spacecraft, and has implications for future instrument design studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LaF3 infrared detector

A class of infrared detectors is proposed, and experimental results are presented for a prototype device. The material used is LaF3, an ionic conductor with a capacitance that varies exponentially with temperature. The detectivity of a prototype detector is estimated from measured signal voltages and incident power, and a Johnson noise voltage is calculated from the measured resistance. At a modulation frequency of 20 Hz, the estimated detectivity is about 2 million cm/sq root Hz/W. For the parameters characterizing this device, the estimated detectivity is consistent with a theoretical prediction. The theory further predicts an optimum detectivity of about 1 billion cm/sq root Hz/W for much thinner devices than the prototypes.

Sher, A.↗

Spatio-spectral quantum state estimation of photon pairs from optical fiber using stimulated emission

Developing a quantum light source that carries more than one bit per photon is pivotal for expanding quantum information applications. Characterizing a high-dimensional multiple-degree-of-freedom source at the single-photon level is challenging due to the large parameter space as well as limited emission rates and detection efficiencies. Here, we characterize photon pairs generated in optical fiber in the transverse-mode and frequency degrees of freedom by applying stimulated emission in both degrees of freedom while detecting in one of them at a time. This method may be useful in the quantum state estimation and optimization of various photon-pair source platforms in which complicated correlations across multiple degrees of freedom may be present.

Kim, Dong Beom (ORCID:0000000346887375)↗

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

Computational biology for target discovery and characterization: a feasibility study in protein-protein interaction detection

In this work we developed new code for detecting putative multi-domain protein-protein interactions for a small network of bacterial pathogen proteins, and determined how structure-driven domain-fusion (DF) methods should be scaled up for whole-proteome analysis. Protein-protein interactions are of great interest in structural biology and are important for understanding the biology of pathogens. The ability to predict protein-protein interactions provides a means for development of anti-microbials that may interfer with key processes in pathogenicity. The function of a protein-protein complex can be elucidated through knowledge of its structure. The overall goal of this project was to determine the feasibility of extending current LLNL capabilities to produce a high-throughput systems bio-informatics capability for identification and characterization of putative interacting protein partners within known or suspected small protein networks. We extended an existing LLNL methodology for identification of putative protein-protein interacting partners (Chakicherla et al (in review)) by writing a new code to identify multi-domain-fusion linkages (3 or more per complex). We applied these codes to the proteins in the Yersinia pestis quorum sensing network, known as the lsr operon, which comprises a virulence mechanism in this pathogen. We determined that efficient application of our computational algorithms in high-throughput for detection of putative protein-protein complexes genome wide would require pre-computation of PDB domains and construction of a domain-domain association database.

99 GENERAL AND MISCELLANEOUS↗

A microbial detection array (MDA) for viral and bacterial detection

Background: Identifying the bacteria and viruses present in a complex sample is useful in disease diagnostics, product safety, environmental characterization, and research. Array-based methods have proven utility to detect in a single assay at a reasonable cost any microbe from the thousands that have been sequenced. Methods: We designed a pan-Microbial Detection Array (MDA) to detect all known viruses (including phages), bacteria and plasmids and developed a novel statistical analysis method to identify mixtures of organisms from complex samples hybridized to the array. The array has broader coverage of bacterial and viral targets and is based on more recent sequence data and more probes per target than other microbial detection/discovery arrays in the literature. Family-specific probes were selected for all sequenced viral and bacterial complete genomes, segments, and plasmids. Probes were designed to tolerate some sequence variation to enable detection of divergent species with homology to sequenced organisms, and to have no significant matches to the human genome sequence. Results: In blinded testing on spiked samples with single or multiple viruses, the MDA was able to correctly identify species or strains. In clinical fecal, serum, and respiratory samples, the MDA was able to detect and characterize multiple viruses, phage, and bacteria in a sample to the family and species level, as confirmed by PCR. Conclusions: The MDA can be used to identify the suite of viruses and bacteria present in complex samples.

59 BASIC BIOLOGICAL SCIENCES↗