Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Activate/Inhibit KGCS Gateway via Master Console EIC Pad-B Display

My internship consisted of two major projects for the Launch Control System.The purpose of the first project was to implement the Application Control Language (ACL) to Activate Data Acquisition (ADA) and to Inhibit Data Acquisition (IDA) the Kennedy Ground Control Sub-Systems (KGCS) Gateway, to update existing Pad-B End Item Control (EIC) Display to program the ADA and IDA buttons with new ACL, and to test and release the ACL Display.The second project consisted of unit testing all of the Application Services Framework (ASF) by March 21st. The XmlFileReader was unit tested and reached 100 coverage. The XmlFileReader class is used to grab information from XML files and use them to initialize elements in the other framework elements by using the Xerces C++ XML Parser; which is open source commercial off the shelf software. The ScriptThread was also tested. ScriptThread manages the creation and activation of script threads. A large amount of the time was used in initializing the environment and learning how to set up unit tests and getting familiar with the specific segments of the project that were assigned to us.

Computer Programming↗

Development and Flight Testing of an Autonomous Landing Gear Health-Monitoring System

Development and testing of an adaptable vehicle health-monitoring architecture is presented. The architecture is being developed for a fleet of vehicles. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle; and, a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained expert system. Communication between all levels is done with wireless radio frequency interfaces. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear. The flight tests were performed to validate the following: the wireless radio frequency communication capabilities of the system, the hardware design, command and control; software operation; and, data acquisition, storage and retrieval.

Woodard, Stanley E.↗

Battery test expert systems

The characteristics of NIHBES (nickel-hydrogen battery expert system) are described, with attention also given to NICBES-2 (nickel-cadmium battery expert system-2). The nickel-hydrogen battery testbed is set up almost identically to the nickel-cadmium battery testbed, with the exceptions of no battery protection and reconditioning circuits (BPRCs) and the frequency of transmission of data. The Ni-H2 testbed has no BPRCs and the data are transmitted every 30 s instead of every minute. An expert system shell was chosen to develop this particular expert system. The GoldWorks expert system shell from Gold Hill Computers was chosen for the task. NIHBES will extract the desired data and return fault diagnosis, status and advice, and decision support. Expert systems have been proven to be viable tools in the control and monitoring of space power systems. Presently, the DDAS (digital data acquisition system) monitors and controls the orbit time, and is responsible for limit checking, data acquisition, and data summaries. It is concluded that in the future control of the Hubble Space Telescope breadboard will be passed to NIHBES. NIHBES will be more beneficial to the testbed than the DDAS alone due to the limitations of the DDAS. The DDAS cannot provide long-term trend analysis, plotting capability, fault diagnosis, or advice.

Johnson, Yvette B.↗

Free-decay time-domain modal identification for large space structures

Concept definition studies for the Modal Identification Experiment (MIE), a proposed space flight experiment for the Space Station Freedom (SSF), have demonstrated advantages and compatibility of free-decay time-domain modal identification techniques with the on-orbit operational constraints of large space structures. Since practical experience with modal identification using actual free-decay responses of large space structures is very limited, several numerical and test data reduction studies were conducted. Major issues and solutions were addressed, including closely-spaced modes, wide frequency range of interest, data acquisition errors, sampling delay, excitation limitations, nonlinearities, and unknown disturbances during free-decay data acquisition. The data processing strategies developed in these studies were applied to numerical simulations of the MIE, test data from a deployable truss, and launch vehicle flight data. Results of these studies indicate free-decay time-domain modal identification methods can provide accurate modal parameters necessary to characterize the structural dynamics of large space structures.

Kim, Hyoung M.↗

RALPH: An online computer program for acquisition and reduction of pulse height data

A background/foreground data acquisition and analysis system incorporating a high level control language was developed for acquiring both singles and dual parameter coincidence data from scintillation detectors at the Radiation Counting Laboratory at the NASA Manned Spacecraft Center in Houston, Texas. The system supports acquisition of gamma ray spectra in a 256 x 256 coincidence matrix (utilizing disk storage) and simultaneous operation of any of several background support and data analysis functions. In addition to special instruments and interfaces, the hardware consists of a PDP-9 with 24K core memory, 256K words of disk storage, and Dectape and Magtape bulk storage.

Davies, R. C.↗

Determination of electron beam polarization using electron detector in Compton polarimeter with less than 1% statistical and systematic uncertainty

The Q-weak experiment aims to measure the weak charge of proton with a precision of 4.2%. The proposed precision on weak charge required a 2.5% measurement of the parity violating asymmetry in elastic electron - proton scattering. Polarimetry was the largest experimental contribution to this uncertainty and a new Compton polarimeter was installed in Hall C at Jefferson Lab to make the goal achievable. In this polarimeter the electron beam collides with green laser light in a low gain Fabry-Perot Cavity; the scattered electrons are detected in 4 planes of a novel diamond micro strip detector while the back scattered photons are detected in lead tungstate crystals. This diamond micro-strip detector is the first such device to be used as a tracking detector in a nuclear and particle physics experiment. The diamond detectors are read out using custom built electronic modules that include a preamplifier, a pulse shaping amplifier and a discriminator for each detector micro-strip. We use field programmable gate array based general purpose logic modules for event selection and histogramming. Extensive Monte Carlo simulations and data acquisition simulations were performed to estimate the systematic uncertainties. Additionally, the Moller and Compton polarimeters were cross calibrated at low electron beam currents using a series of interleaved measurements. In this dissertation, we describe all the subsystems of the Compton polarimeter with emphasis on the electron detector. We focus on the FPGA based data acquisition system built by the author and the data analysis methods implemented by the author. The simulations of the data acquisition and the polarimeter that helped rigorously establish the systematic uncertainties of the polarimeter are also elaborated, resulting in the first sub 1% measurement of low energy (?1 GeV) electron beam polarization with a Compton electron detector. We have demonstrated that diamond based micro-strip detectors can be used for tracking in a high radiation environment and it has enabled us to achieve the desired precision in the measurement of the electron beam polarization which in turn has allowed the most precise determination of the weak charge of the proton.

43 PARTICLE ACCELERATORS↗

Encryption of Signal Pulses to Replace Tamper-indicating Conduit

In order to verify signal integrity and point of origin for TTL pulse data used in IAEA systems, and to avoid the need for expensive tamper-indicating conduit or electronic techniques, we propose the development of a signal pulse signing and encryption in-line device. In measurement applications in which the data acquisition electronics is separate from the enclosed, sealed detector, tamper-indicating techniques are required to protect raw TTL pulse streams between the detector and the data acquisition module, i.e UMSR. The goal of this proposed project is to design a rad-tolerant transmitter that would mount inside the sealed detector system and a receiver in the sealed electronics cabinet with the data acquisition instrument. This transmitter/receiver pair would digitally sign and encrypt the pulse stream data at the detector then transmit the data to the sealed cabinet where the receiver would decrypt the data and reproduce the original pulse stream. Existing tamper indicating techniques, such as LiveWire’s spread spectrum time domain reflectometry rely on detecting physical changes to the wiring system and can be blind to fast coupling of micro-second wide pulses. Digital signing and encryption techniques such as the Sandia Laboratories Enhanced Data Authentication System (EDAS) are capable of encrypting communications data, i.e. RS-232, but are not capable reproducing a critical time correlated data streams. Recent NA-241 Safeguards Technology supported developments have reduced the need for special conduit to transmit data via Ethernet by incorporating the IAEA RAINSTORM data encryption and authentication protocol, a tamper indicator is still required to protect raw pulse data from detectors to the acquisition electronics. Encrypting pulse data is especially complicated for radiation detection instruments due to the time correlation data analysis that is performed on this data stream. Any corruption in the timing information will produce errors in measurement values.

97 MATHEMATICS AND COMPUTING↗

Development and Flight Testing of an Adaptive Vehicle Health-Monitoring Architecture

On going development and testing of an adaptable vehicle health-monitoring architecture is presented. The architecture is being developed for a fleet of vehicles. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle, and, a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained expert system. The expert system is parameterized, which makes it adaptable to be trained to both a user's subject reasoning and existing quantitative analytic tools. Communication between all levels is done with wireless radio frequency interfaces. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear. The flight tests were performed to validate the following: the wireless radio frequency communication capabilities of the system, the hardware design, command and control; software operation and, data acquisition, storage and retrieval.

Woodard, Stanley E.↗

Development of an FPGA-based multipoint laser pyroshock measurement system for explosive bolts

Pyroshock can cause failure to the objective of an aerospace structure by damaging its sensitive electronic equipment, which is responsible for performing decisive operations. A pyroshock is the high intensity shock wave that is generated when a pyrotechnic device is explosively triggered to separate, release, or activate structural subsystems of an aerospace architecture. Pyroshock measurement plays an important role in experimental simulations to understand the characteristics of pyroshock on the host structure. This paper presents a technology to measure a pyroshock wave at multiple points using laser Doppler vibrometers (LDVs). These LDVs detect the pyroshock wave generated due to an explosive-based pyrotechnical event. Field programmable gate array (FPGA) based data acquisition is used in the study to acquire pyroshock signals simultaneously from multiple channels. This paper describes the complete system design for multipoint pyroshock measurement. The firmware architecture for the implementation of multichannel data acquisition on an FPGA-based development board is also discussed. An experiment using explosive bolts was configured to test the reliability of the system. Pyroshock was generated using explosive excitation on a 22-mm-thick steel plate. Three LDVs were deployed to capture the pyroshock wave at different points. The pyroshocks captured were displayed as acceleration plots. The results showed that our system effectively captured the pyroshock wave with a peak-to-peak magnitude of 303 741 g. The contribution of this paper is a specialized architecture of firmware design programmed in FPGA for data acquisition of large amount of multichannel pyroshock data. The advantages of the developed system are the near-field, multipoint, non-contact, and remote measurement of a pyroshock wave, which is dangerous and expensive to produce in aerospace pyrotechnic tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open Source Platform for Live Processing of High Data Rate Electron Microscopy (SBIR Phase I Award Topic 15, Subtopic B, Final Scientific / Technical Report)

4D scanning transmission electron microscopy (STEM) is experiencing a revolution both in terms of data size, and data veracity, as are many other areas of experimental data acquisition. This presents enormous opportunities to make new scientific discoveries, but is also hamstrung by aging software that is no longer fit for purpose. Experimental data acquisition platforms must make the same investments in software infrastructure that the simulation community made decades ago to take advantage of high-performance computing (HPC) if they hope to realize the full potential of the latest advances made in detector technology. This requires rethinking the design and deployment of hardware, moving away from small, fixed commodity computing capabilities with closed interfaces to open, modular, scalable systems designed for parallelism and throughput. The technical approach will leverage best-in-class open source technologies, and develop new approaches strategically to build an open source platform for experimental data acquisition targeting high data rate electron microscopy. The project will develop a software platform that uses the power and performance of modern HPC resources to ingest the large volume of data produced by electron microscopes using direct electron detectors. A set of configurable pipelines will be used to enable the processing to be tailored to the problem being investigated with builtin visualization of data at interactive rates. This project will leverage investments made by the DOE and other agencies to provide a powerful software platform for the experimental data community working with most powerful electron microscopes, such as 4D STEM detectors. It will create a platform that serves as a reference for the community. Permissive open source licensing will make the platform available to all, with a simple deployment strategy offering the ability to keep data close to where it is generated. This advanced software platform will require customization for each deployment, creating opportunities for software services that are typically offered to extend open source software platforms.

97 MATHEMATICS AND COMPUTING↗

Investigating the non-ideal behavior of the Amptek A111 charge sensitive preamplifier & discriminator board— 3 He proportional counter combination used in common safeguards neutron coincidence counters

Neutron coincidence counting is a well-established technique used for the nondestructive quantification of specialnuclear material during international safeguards inspections. The neutron counters are commonly designedwith an annular body, centered about an inner well or cavity into which a measurement item is placed,and the moderating annulus is populated with 3 He tubes connected to a varying number of preamplifiers.The Canberra Industries JAB-01 preamplifier/amplifier/discriminator board is employed within the company’sneutron coincidence counters, built for use by the International Atomic Energy Agency. Non-ideal behavior ofthese boards was identified during a detector characterization, using list mode data acquisition, of a CanberraIndustries JCC-71 Neutron Coincidence Collar implementing four JAB-01 boards. List mode data acquisition andanalysis reveals features that have commonly been overlooked by historic timing gate selection while using shiftregister data acquisition methods, which are routinely adopted in international safeguards. It has been shownthat double pulsing effects are not fully captured within the predelay setting; therefore, they may influencethe response of the system within the standard operating regime. We set out to identify and correct for doublepulsing in our post analysis of neutron pulse trains, while isolating this behavior to the relevant system. Tounderstand and potentially address these concerns, the responses of two different JAB-01 board systems – theJCC-71 Neutron Coincidence Collar and a modified JCC-51 Active Well Neutron Coincidence Counter – arecompared with the responses of an AnTech Inc. N2071 Neutron Coincidence Collar that also uses an amplifierbuilt on the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip, and a JCC-71 that employs custompreamplifiers designed at Oak Ridge National Laboratory

42 ENGINEERING↗

Application of a PC based, real-time, data-aquisition system in rotorcraft wind-tunnel testing

Data has been acquired for a rotocraft test in the NASA Langley Transonic Dynamics Tunnel using a desktop data acquisition system. The system, which consists of an IBM Personal Computer AT (PC-AT) and an Omega Engineering OM-900 Stand-Alone Interface System, is well suited for acquiring high speed data on a limited number of channels. The data acquisition system and the interrupt driven software which provides the capability for near real-time cyclic data acquisition as well as data storage and display are described.

Wilbur, Matthew L.↗

Advanced Neutron Counting Electronics Designed and Implemented on the JCC-71 Neutron Coincidence Collar to Replace Standard JAB-01 Preamplifier/Amplifier/Discriminator Boards

New in-house neutron counting electronics were designed and built at Oak Ridge National Laboratory to replace the Canberra Industries JAB-01 preamplifier/amplifier/discriminator boards on their JCC-71 Neutron Coincidence Collar model system. The new electronics include a preamplifier and motherboard design, which fit inside the footprint of the existing junction box, as well as an external “ORNL Neutron Collar Processor” board. The goal of the new electronics is to provide the same neutron processing functionalities as the JAB-01 boards and extend the capabilities of the JCC-71 system by placing a preamplifier on each of the 18 3He tubes to facilitate neutron list mode data acquisition. Each 3He tube is then capable of producing an individual signal output to be analyzed using a list mode data acquisition system such as the PTR-32 or N2000. List mode data analysis provides the opportunity to use all 18 signal channels to produce a spatial response matrix to assay fresh nuclear fuel assemblies. This paper describes the development of the new electronics and provides performance comparison measurements between the two electronics board systems using list mode data acquisition.

Moore, Angela↗

Sonic boom measurement test plan for Space Shuttle STS-2 reentry

Procedures and system specifications associated with the space shuttle STS-2 sonic boom measurement program are described. Specifically included are details such as mobile data acquisition station locations, measurement systems calibration levels, predicted sonic boom overpressure levels, overpressure level assignment for each data acquisition station, data recording times on and off, universal coordinate time, and measurement system descriptions.

Henderson, H. R.↗

Sampling synchronization through GPS signals

A method uses a distributed data acquisition system with multiple, physically unconnected, data acquisition units, that can be in wireless communication with a remote host, to timestamp measurement data with sub-microsecond time base accuracy of sampling clock relative to an absolute timeframe. A current absolute time is derived from messages received from a satellite radio beacon positioning system (GPS). Measurement data is sampled by each unit at a specified sampling rate. Using hardware logic, batches of sampled data are associated with corresponding timestamps representing the absolute time at which the data was sampled. Data and timestamps may be transmitted to the host. A time offset bias is compensated by comparing timestamps against a nominal time based on start time and nominal sampling rate. The sampling clock rate may be disciplined using time pulses from the GPS receiver. An initial start of data sampling by all units can also be synchronized.

Zhuge, James Q.↗

SpaceOps 1992: Proceedings of the Second International Symposium on Ground Data Systems for Space Mission Operations

The Second International Symposium featured 135 oral presentations in these 12 categories: Future Missions and Operations; System-Level Architectures; Mission-Specific Systems; Mission and Science Planning and Sequencing; Mission Control; Operations Automation and Emerging Technologies; Data Acquisition; Navigation; Operations Support Services; Engineering Data Analysis of Space Vehicle and Ground Systems; Telemetry Processing, Mission Data Management, and Data Archiving; and Operations Management. Topics focused on improvements in the productivity, effectiveness, efficiency, and quality of mission operations, ground systems, and data acquisition. Also emphasized were accomplishments in management of human factors; use of information systems to improve data retrieval, reporting, and archiving; design and implementation of logistics support for mission operations; and the use of telescience and teleoperations.

Source record↗

Making Quality HPGe Gamma Ray Spectrum Measurements for Uranium: The Role of FRAM for Analysis, Quality Control and Enrichment Measurements, and Opportunities for Improved Quantification Documentation

Enrichment measurements are used in uranium safeguards verification and accountancy as both an attribute signature and in the interpretation of other nondestructive assay information, such as active interrogation for mass. Accurate and reliable assessments require quality information. The practices used to collect the raw data are therefore the crucial first step in managing the overall quality and uncertainty of the enrichment determination. This report discusses several topics associated with gamma-ray spectrum measurements of uranium using HPGe detectors. First a discussion of good data acquisition practices including physical setup, detector types and configurations, detector shielding and filtering, spectrum stabilization, and data acquisition protocols. Next is a discussion of analysis options to obtain isotopic composition and/or enrichment centered on the FRAM gamma ray isotopic analysis software. The report discusses the results of the development of a FRAM parameter file to perform classical Enrichment Meter Principle (EMP) analysis. Possible analysis and data acquisition issues (random summing, x-ray fluorescence peaks, peak interferences, shielding) that can affect FRAM analyses are also discussed. There is also a brief discussion of FRAM measurements in the field. Under the topic of uncertainty propagation and quantification in FRAM, uncertainty propagation verification methods and gaps in available uncertainty quantification data for uranium is covered. Suggestions are made for areas where ORNL can contribute to closing the identified uncertainty quantification gaps, and also to contributing nuclear data quality spectra to the research community.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automating data analysis for hydrogen/deuterium exchange mass spectrometry using data-independent acquisition methodology

We present a hydrogen/deuterium exchange workflow coupled to tandem mass spectrometry (HX-MS 2 ) that supports the acquisition of peptide fragment ions alongside their peptide precursors. The approach enables true auto-curation of HX data by mining a rich set of deuterated fragments, generated by collisional-induced dissociation (CID), to simultaneously confirm the peptide ID and authenticate MS 1 -based deuteration calculations. The high redundancy provided by the fragments supports a confidence assessment of deuterium calculations using a combinatorial strategy. The approach requires data-independent acquisition (DIA) methods that are available on most MS platforms, making the switch to HX-MS 2 straightforward. Importantly, we find that HX-DIA enables a proteomics-grade approach and wide-spread applications. Considerable time is saved through auto-curation and complex samples can now be characterized and at higher throughput. We illustrate these advantages in a drug binding analysis of the ultra-large protein kinase DNA-PKcs, isolated directly from mammalian cells.

59 BASIC BIOLOGICAL SCIENCES↗