Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DATA PROCESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Threshold and spin factors in the yield of bremsstrahlung-induced reactions

Relative yields of photon-induced reactions are systematized in a function of the threshold parameter for moderately heavy targets at the bremsstrahlung end-point energy lower than 30 MeV. Regular dependence is established for the group of (γ, n), (γ, p), and (γ, d) reactions, while the yields of (γ, 2n) and (γ,α) reactions deviate from the regularity. Physical conclusions are discussed and possible application of this systematic for data processing is proposed. In particular, the constituent threshold and spin factors in the isomer-to-ground-state ratio could be isolated separately. For spin dependence of the yields, a new regularization parameter is introduced and previously hidden peculiarities are concluded.

74 ATOMIC AND MOLECULAR PHYSICS↗

Upgraded multipulse laser and multipoint Thomson scattering diagnostics on EAST

Recently a new Thomson scattering diagnostic system was upgraded in EAST tokamak experiment using a multipulse Nd:YAG (neodymium--yttrium aluminium garnet) laser and a multipoint observation volumes. This diagnostic uses a new optical laser alignment technique that was made to determine accurately the laser position, and a new lens collection system that enables the measurement of wider plasma's object. A composite control system made we can get the results in several seconds. Furthermore, a new data processing method was adopted for much exact results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Study for a Low-enriched Uranium Core for the High Flux Isotope Reactor, Annual Report for FY 2007

This report documents progress made during fiscal year 2007 in studies of converting the High Flux Isotope Reactor (HFIR) from highly enriched uranium (HEU) fuel to low enriched uranium fuel (LEU). Conversion from HEU to LEU will require a change in fuel form from uranium oxide to a uranium-molybdenum alloy. A high volume fraction U/Mo-in-Al fuel could attain the same neutron flux performance as with the current, HEU fuel but materials considerations appear to preclude production and irradiation of such a fuel. A diffusion barrier would be required if Al is to be retained as the interstitial medium and the additional volume required for this barrier would degrade performance. Attaining the high volume fraction (55 wt. %) of U/Mo assumed in the computational study while maintaining the current fuel plate acceptance level at the fuel manufacturer is unlikely, i.e. no increase in the percentage of plates rejected for non-compliance with the fuel specification. Substitution of a zirconium alloy for Al would significantly increase the weight of the fuel element, the cost of the fuel element, and introduce an as-yet untried manufacturing process. A monolithic U-10Mo foil is the choice of LEU fuel for HFIR. Preliminary calculations indicate that with a modest increase in reactor power, the flux performance of the reactor can be maintained at the current level. A linearly-graded, radial fuel thickness profile is preferred to the arched profile currently used in HEU fuel because the LEU fuel media is a metal alloy foil rather than a powder. Developments in analysis capability and nuclear data processing techniques are underway with the goal of verifying the preliminary calculations of LEU flux performance. A conceptual study of the operational cost of an LEU fuel fabrication facility yielded the conclusion that the annual fuel cost to the HFIR would increase significantly from the current, HEU fuel cycle. Though manufacturing can be accomplished with existing technology, several engineering proof-of-principle tests would be required. The RERTR program is currently conducting a series of generic fuel qualification tests at the Advanced Test Reactor. A review of these tests and a review of the safety basis for the current, HEU fuel cycle led to the identification of a set of HFIR-specific fuel qualification tests. Much additional study is required to formulate a HFIR-specific fuel qualification plan from this set. However, one such test - creating a graded fuel profile across a flat foil - has been initiated with promising results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Future Looks Bright for Teraflop Computing

Wouldn’t it be great to have a teraflop of computing power sitting in your lab, desktop workstation, or remote instrument server? Talk about simplifying workflows, eliminating competition for HPC resources, and allowing more scientists and technicians to get more work done! Well, the computer industry is marketing that capability now in the form of high-end video cards – and for a bargain price – with more and better technology on the market horizon. As the industry evolves to become more oriented toward multi-core and multi-threaded hardware; video card manufacturers are attempting to transition from a niche to multi-purpose market. One of the products currently getting attention is the Nvidia Tesla family of products based on the Tesla GPGPU (general purpose graphics processing unit). This card contains 128 processor computing core engines advertised as having the ability to deliver an aggregate 518 billion single-precision floating operations per second (518 Gflop), which is being introduced at a $1499 MSRP price-point. Nvidia also offers other commodity graphics cards, such as the GeForce 8800, which appear on paper to have roughly the same performance for roughly half the price – although with half the memory (768M vs the Tesla 1.5 GB). This highlights how the Tesla GPGPUs are essentially redesigned graphics cards (with no video capability, increased memory, and clock changes) that fit into PCI-Express slots in your motherboard. If you believe Nvidia’s claims, two Tesla cards will - for the right applications - turn your lab workstation into a teraflop capable supercomputer. Double-precision versions are projected for a late 2007 introduction with expected 2008 delivery. The Nvidia Tesla GPGPU is one step forward in the many-core revolution that is happening in the computer industry. Instead of making two or four processing cores available to the user, many-core processors offer tens or hundreds of processing cores. Many-core processors promise to provide very high performance-per-dollar and performance-per-watt for many computational workloads. Intel is working on their version of many-core processors but delivery dates appear to be several years in the future. Last year Intel made a large splash with their proof-of-concept teraflop 80-core chip, which they announced might be available sometime in 2011. Intel is also working on something similar to the Nvidia Tesla – codename Larrabee – which will perform in the teraflop range and has a release date of sometime around 2009 or 2010. Larrabee is supposed to have 16 – 24 cores and several nice features. Bottom line: A teraflop lab computer is feasible today as the programmable Nvidia GeForce 8 and Quadro family of graphics cards are available now, Tesla cards will be shipping, and exciting many-core architectures are on the horizon from a number of vendors. Definitely, the potential for parallel processing systems is huge, and GPGPUs certainly provide parallel processing, but are there enough applications out there to take them mainstream and make it more appealing to businesses other than just research firms? Only time will tell as more applications are developed to utilize this computational capability. Right now, programming is required. Recently Google purchased PeakStream, a firm that engaged in abstracting the task of running multiple threads to software with specific GPGPU applicability. However, Google is a visionary software company. Instrument vendors and much of the software industry are still in the early stages of the transition to multi-threaded many-core data processing. Applications that exploit the full potential of parallel processing systems, and GPGPUs in particular, really don’t exist in today’s market. The development of Matlab plug-ins is a very positive sign for the future of GPGPUs and is indicative of Nvidia’s sense of where the market is headed.

99 GENERAL AND MISCELLANEOUS↗

SPECKLE INTERFEROMETRY AT THE BLANCO AND SOAR TELESCOPES IN 2008 AND 2009

The results of speckle interferometric measurements of binary and multiple stars conducted in 2008 and 2009 at the Blanco and SOAR 4 m telescopes in Chile are presented. A total of 1898 measurements of 1189 resolved pairs or sub-systems and 394 observations of 285 un-resolved targets are listed. We resolved for the first time 48 new pairs, 21 of which are new sub-systems in close visual multiple stars. Typical internal measurement precision is 0.3 mas in both coordinates, typical companion detection capability is {delta}m {approx} 4.2 at 0.''15 separation. These data were obtained with a new electron-multiplication CCD camera; data processing is described in detail, including estimation of magnitude difference, observational errors, detection limits, and analysis of artifacts. We comment on some newly discovered pairs and objects of special interest.

79 ASTRONOMY AND ASTROPHYSICS↗

DEEPEN Leapfrog Geodata Model Cleaned and Reformatted Exploration Datasets from Newberry Volcano

DEEPEN stands for DE-risking Exploration of geothermal Plays in magmatic ENvironments. As part of the DEEPEN 3D play fairway analysis (PFA) conducted at Newberry Volcano for multiple play types (conventional hydrothermal, superhot EGS, and supercritical), existing geoscientific exploration datasets needed to be acquired, cleaned, reformatted, and assembled in Leapfrog Geothermal. This GDR submission includes all of the cleaned and reformatted (X (m), Y (m), elevation (m), processed data values) datasets used to build the Leapfrog Geodata model. Existing datasets were acquired from the GDR, from AltaRock, and from other sources. This yielded the following datasets: - Digital elevation model produced from LiDAR data by Ramsey and Bard, 2016 - MT surveys from 2006, 2011, 2014, and 2017 (including single inversions) - Gravity surveys from 2006, 2007, and 2011 (including single) - Earthquake catalogs from PNSN, LLNL, and the Newberry EGS Demonstration project - Seismic velocity model from Templeton et al., 2014 - The Frone, 2015 temperature model and a new one produced through extrapolating downhole temperature measurements and the SMU temperature at depth maps. Two versions of the new model are provided: 250 m spacing and 500 m spacing - EarthVision geologic model with alteration from Moser et al., 2016 - Well data from EGS well 55-29, deep geothermal wells, coreholes (GEO N-2 through 5) and several thermal gradient holes - "Newberry Well Data:" Location, simple lithology, directional survey data, and temperature data for the 34 wells and coreholes used in the Newberry PFA Although there are additional 2D datasets available in the area, such as aeromagnetic surveys, these were not included in the analysis. While it may be possible to project these datasets into three dimensions by assuming the surface measurements do not vary with depth, this method is associated with high uncertainty. Preexisting inversions of these data were unavailable, and inverting additional geophysical datasets is outside the scope of this project.

15 GEOTHERMAL ENERGY↗

Experimental comparison of grating- and propagation-based hard X-ray phase tomography of soft tissue

When imaging soft tissues with hard X-rays, phase contrast is often preferred over conventional attenuation contrast due its superior sensitivity. However, it is unclear which of the numerous phase tomography methods yields the optimized results at given experimental conditions. Therefore, we quantitatively compared the three phase tomography methods implemented at the beamline ID19 of the European Synchrotron Radiation Facility: X-ray grating interferometry (XGI), and propagation-based phase tomography, i.e., single-distance phase retrieval (SDPR) and holotomography (HT), using cancerous tissue from a mouse model and an entire heart of a rat. We show that for both specimens, the spatial resolution derived from the characteristic morphological features is about a factor of two better for HT and SDPR compared to XGI, whereas the XGI data generally exhibit much better contrast-to-noise ratios for the anatomical features. Moreover, XGI excels in fidelity of the density measurements, and is also more robust against low-frequency artifacts than HT, but it might suffer from phase-wrapping artifacts. Thus, we can regard the three phase tomography methods discussed as complementary. The application will decide which spatial and density resolutions are desired, for the imaging task and dose requirements, and, in addition, the applicant must choose between the complexity of the experimental setup and the one of data processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-272: Direct Verification of a Treatment Planning System Megavoltage Linac Beam Photon Spectra Models, and Analysis of the Effects On Patient Plans

Purpose: For the photon dose calculation Philips Pinnacle Treatment Planning System (TPS) uses collapsed cone convolution algorithm, which relies on energy spectrum of the beam in computing the scatter component. The spectrum is modeled based on Linac’s standard commissioning data and typically is not independently verified. We explored a methodology of using transmission measurements in combination with regularization data processing to unfold Linac spectra. The measured spectra were compared to those modeled by the TPS, and the effect on patient plans was evaluated. Methods: Transmission measurements were conducted in narrow-beam geometry using a standard Farmer ionization chamber. Two attenuating materials and two build -up caps, having different atomic numbers, served to enhance discrimination between absorption of low and high-energy portions of the spectra, thus improving the accuracy of the results. The data was analyzed using a regularization technique implemented through spreadsheet-based calculations. Results: The unfolded spectra were found to deviate from the TPS beam models. The effect of such deviations on treatment planning was evaluated for patient plans through dose distribution calculations with either TPS modeled or measured energy spectra. The differences were reviewed through comparison of isodose distributions, and quantified based on maximum dose values for critical structures. While in most cases no drastic differences in the calculated doses were observed, plans with deviations of 4 to 8% in the maximum dose values for critical structures were discovered. The anatomical sites with large scatter contributions are the most vulnerable to inaccuracies in the modeled spectrum. Conclusion: An independent check of the TPS model spectrum is highly desirable and should be included as part of commissioning of a new Linac. The effect is particularly important for dose calculations in high heterogeneity regions. The developed approach makes acquisition of megavoltage Linac beam spectra achievable in a typical radiation oncology clinic.

60 APPLIED LIFE SCIENCES↗

Approximate recoverability and relative entropy II: 2-positive channels of general von Neumann algebras

Abstract We generalize our results in paper I in this series to quantum channels between general von Neumann algebras, proving the approximate recoverability of states which undergo a small change in relative entropy through the channel. To this end, we derive a strengthened form of the quantum data processing inequality for the change in relative entropy of two states under a channel between two von Neumann algebras. Compared to the usual inequality, there is an explicit lower bound involving the fidelity between the original state and a recovery channel.

97 MATHEMATICS AND COMPUTING↗

Air Shower Measurements with Radio Antennas: The LOPES Project

LOPES is set up at the location of the KASCADE-Grande extensive air shower experiment in Karlsruhe, Germany and aims to measure and calibrate radio pulses from Extensive Air Showers. LOPES is designed as a digital radio interferometer using high bandwidths and fast data processing and profits from the reconstructed air shower observables of KASCADE-Grande. First results of the LOPES experiment are very promising for a future large scale application of the technique to detect cosmic rays of highest energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beyond integration: modeling every pixel to obtain better structure factors from stills

Most crystallographic data processing methods use pixel integration. In serial femtosecond crystallography (SFX), the intricate interaction between the reciprocal lattice point and the Ewald sphere is integrated out by averaging symmetrically equivalent observations recorded across a large number (10 4 -10 6 ) of exposures. Although sufficient for generating biological insights, this approach converges slowly, and using it to accurately measure anomalous differences has proved difficult. This report presents a novel approach for increasing the accuracy of structure factors obtained from SFX data. A physical model describing all observed pixels is defined to a degree of complexity such that it can decouple the various contributions to the pixel intensities. Model dependencies include lattice orientation, unit-cell dimensions, mosaic structure, incident photon spectra and structure factor amplitudes. Maximum likelihood estimation is used to optimize all model parameters. The application of prior knowledge that structure factor amplitudes are positive quantities is included in the form of a reparameterization. The method is tested using a synthesized SFX dataset of ytterbium(III) lysozyme, where each X-ray laser pulse energy is centered at 9034 eV. This energy is 100 eV above the Yb 3+ L -III absorption edge, so the anomalous difference signal is stable at 10 electrons despite the inherent energy jitter of each femtosecond X-ray laser pulse. This work demonstrates that this approach allows the determination of anomalous structure factors with very high accuracy while requiring an order-of-magnitude fewer shots than conventional integration-based methods would require to achieve similar results.

59 BASIC BIOLOGICAL SCIENCES↗

Note: Switching crosstalk on and off in Kelvin probe force microscopy

In Kelvin Probe Force Microscopy (KPFM) electronic crosstalk can occur between the excitation signal and probe deflection signal. Here, we demonstrate how a small modification to our commercial instrument enables us to literally switch the crosstalk on and off. We study in detail the effect of crosstalk on open-loop KPFM and compare with closed-loop KPFM. We measure the pure crosstalk signal and verify that we can correct for it in the data-processing required for open-loop KPFM. We also demonstrate that open-loop KPFM results are independent of the frequency and amplitude of the excitation signal, provided that the influence of crosstalk has been eliminated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visual Scanning Hartmann Optical Tester (VSHOT) Uncertainty Analysis (Milestone Report)

In 1997, an uncertainty analysis was conducted of the Video Scanning Hartmann Optical Tester (VSHOT). In 2010, we have completed a new analysis, based primarily on the geometric optics of the system, and it shows sensitivities to various design and operational parameters. We discuss sources of error with measuring devices, instrument calibrations, and operator measurements for a parabolic troughmirror panel test. These help to guide the operator in proper setup, and help end-users to understand the data they are provided. We include both the systematic (bias) and random (precision) errors for VSHOT testing and their contributions to the uncertainty. The contributing factors we considered in this study are: target tilt; target face to laser output distance; instrument vertical offset;laser output angle; distance between the tool and the test piece; camera calibration; and laser scanner. These contributing factors were applied to the calculated slope error, focal length, and test article tilt that are generated by the VSHOT data processing. Results show the estimated 2-sigma uncertainty in slope error for a parabolic trough line scan test to be +/-0.2 milliradians;uncertainty in the focal length is +/- 0.1 mm, and the uncertainty in test article tilt is +/- 0.04 milliradians.

14 SOLAR ENERGY↗

Recent progress in vacuum-ultraviolet polarization modulation spectroscopy using polarizing undulator at the TERAS BL5 beamline

Polarization modulation spectroscopy using an Onuki-type undulator is a useful technique for circular dichroism study in the vacuum-ultraviolet region. We have been developing the vacuum-ultraviolet circular dichroism (vuv-CD) spectroscopy in TERAS BL5 beamline at AIST. This paper describes recent improvements in our instrumentation and methods of analysis to achieve precise and absolute measurements. The CD signal is usually accompanied by experimental artifacts, and elimination of all possible artifacts is the key issue for making reliable measurements. After improving beamline optical system, light flux monitor, and undulator operation method, the base line shift of the CD spectrum is suppressed less than 3x10{sup -4}. Sample manipulation and data processing procedures are also described and absolute CD spectrum can be obtained even for linear anisotropic sample. These progresses lead to more quantitative comparison of experimental with calculation on vuv-CD spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R and DE Robotic Sensor Intern Team: Remote 3D Mapping Sensor Suite

The primary goal of the sensor suite is to provide an internal 3D map of the HCAEX tunnel. When looking for a sensor that would provide XYZ point cloud data for mapping the decision was between a stereo camera, a 3D Lidar, or a 2D Lidar that would need to be spun around. The issues with the stereo camera were that it does not have a large field-of-view and that its depth information was not nearly as accurate as even the baseline Lidars. The selection between Lidars is detailed. The Hokuyo UTM-30LX-EW shown provides a 270 deg. FOV with high accuracy and resolution while the largest FOV on a 3D Lidar is 40 deg.. This was the reason a 2D Lidar was chosen over the 3D Lidar. Even though the 2D Lidar requires additional components and software to generate a 3D map, its FOV advantage is too great given that the HCAEX tunnel is a relatively confined space. The rotating planar scan from the 2D Lidar can be stitched into a 3D scan as shown in the graphic below. Along with XYZ data, the Lidar provides return intensity data in color which can be used to distinguish between different materials within the tunnel. To provide visual feedback a camera system needed to be identified. The common solution for this is a high resolution camera with a small FOV mounted on a pan-tilt system. But, given the critical nature of the visual feedback we looked into solutions without the need for moving parts. Two panospheric cameras give a FOV large enough to get a full 360 deg. view.. Camera color data (RGB) can also be combined with the 3D mapping data from the Lidar and overlaid on the map to give the user the ability to see inside the entire length of the tunnel as if they were inside. Situational awareness is required for the crawler in the tunnel in order for it to be able to register the 3D scans to create a final map. For this we procured a Microstrain 3DM-GX5-25 Inertial Measurement Unit (IMU). To perform the Lidar rotation we have two servos driving the pan and tilt. The servo controls and most data processing will be performed via an onboard computer. The sensor components are to be packaged together using 3D printed mounts into a standalone unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synchrotron Area X-ray Detectors, Present and Future

X-ray experiments are very frequently detector limited at today's storage ring synchrotron radiation (SR) sources, and will be even more so at future Energy Recovery Linac and X-ray Free Electron Laser sources. Image plate and phosphor-coupled CCD detectors that predominate at present-day sources were outgrowths of technologies initially developed for the medical and astronomical communities, respectively, with resultant limitations for SR. These limitations are enumerated. The growth of commercial silicon foundries and design tools enabling the production of large, customized integrated circuits is beginning to have a profound impact on SR detectors and is ushering in the age of 'designer detectors'. Novel area Pixel Array Detectors (PADs) are starting to appear in which each pixel has dedicated, complex circuitry capable of high speed and, in some cases, significant data processing power for specific applications. PADs now at, or near the horizon will be described. Integrated circuit methods continue to develop at a rapid pace. Implications for future x-ray detectors will be discussed.

43 PARTICLE ACCELERATORS↗

FROM NDE WITH A Q TO SHM AND BEYOND

In the nineteen-sixties, a significant limitation of NDI and NDE became apparent with the advent of fracture mechanics. Fracture mechanics requires quantitative information on defects, which has to be obtained from quantitative non-destructive testing. A DARPA Program directed by Don Thompson provided the point of departure for the journey to put the Q with NDE. The DARPA Program, and subsequent DOD, FAA and industrial programs produced seminal results for diagnostics and prognostics. In diagnostics, measurement models, probability of detection considerations and techniques of defect characterization were developed, which were complemented by damage evolution laws, probabilistic failure analysis and damage progression estimates, for methods of prognostication. The new results in QNDE naturally led to the concept of structural health monitoring (SHM), whereby sensors are permanently installed on structures. An SHM system can provide on-demand (or continuous) information on the state of a structure, so that an assessment of the structural integrity can be made at any time, and timely remedial actions can be taken. In this paper, we review the development of QNDE towards SHM. Sensor development, data processing, materials engineering and solid mechanics play dominant roles in both the diagnostic and the prognostic components of SHM. A probabilistic approach is essential, as will be shown by examples of pre-crack fatigue damage, crack growth and optimization of an inspection schedule.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status and expected perfomance of the MAXI mission for the JEM/ISS

MAXI (Monitor of All-sky X-ray Image) is the first payload to be attached on JEM-EF (Kibo exposed facility) of ISS. It provides an all sky X-ray image every ISS orbit. Only with a few weeks scan, MAXI is expected to make a milli-Crab X-ray all sky map excluding bright region around the sun. Thus, MAXI does not only inform X-ray novae and transients rapidly to world astronomers if once they occur, but also observes long-term variability of Galact ic and extra-Galactic X-ray sources. MAXI also provides an X-ray source catalogue at that time with diffuse cosmic X-ray background. MAXI consists of two kinds of detectors, position sensitive gas-proportional counters for 2-30 keV X-rays and CCD cameras for 0.5-10 keV X-rays. All instruments of MAXI are now in final phase of pre-launching tests of their flight modules. We are also carrying out performance tests for X-ray detectors and collimators. Data processing and analysis software including alert system on ground are being developed by mission team. In this paper we report an overview of final instruments of MAXI and capability of MAXI.

79 ASTRONOMY AND ASTROPHYSICS↗