High Throughput Coefficient Thermal Expansion Testing Utilizing Digital Image Correlation

Dr. Fitzgerald, a postdoc at Sandia National Laboratories, works in a materials of mechanics group characterizing material properties of ductile materials. Her presentation focuses specifically on increasing throughput of coefficient of thermal expansion (CTE) measurements with the use of optical strain measurements, called digital image correlation (DIC). Currently, the coefficient of thermal expansion is found through a time intensive process called dilatometry. There are multiple types of dilatometers. One type, a double push rod mechanical dilatometer, uses and LVDT to measure the expansion of a specimen in one direction. It uses a reference material with known properties to determine the CTE of the specimen in question. Testing about 500 samples using the double push rod mechanical dilatometer would take about 2 years if testing Monday through Friday, because the reference material needs to be at a constant temperature and heating must done slowly to ensure no thermal gradients across the rod. A second type, scissors type dilatometer, pinches a sample using a “scissor-like” appendage that also uses a LVDT to measure thermal expansion as the sample is heated. Finally, laser dilatometry, was created to provide a non-contact means to measure thermal expansion. This process greatly reduces the time required to setup a measurement but is still only able to measure one sample at a time. The time required to test 500 samples gets reduced to 3.5 weeks. Additionally, to measure expansion in different directions, multiple lasers must be used. Dr. Fitzgerald solved this conundrum by using an optical measurement technique called digital image correlation to create strain maps in multiple orientations as well as measuring multiple samples at once. Using this technique, Dr. Fitzgerald can test 500 samples, conservatively, in 2 days.

36 MATERIALS SCIENCE↗

Trap-assisted Auger-Meitner recombination in GaN p-i-n diodes

Most properties of semiconductor devices are dominated by shallow impurities. However, deep defects often play an important role, for instance, in recombination processes or high field transport. While a variety of techniques are available to assess the density and energy levels of impurities, other properties, such as the recombination mechanisms of the defects, escape observation. We report on the direct measurement of hot electrons generated by trap-assisted Auger-Meitner recombination (TAAR) in GaN p-i-n diodes. By performing electron emission spectroscopy (EES) on diodes with surfaces activated to negative electron affinity by cesium, we observe the expected overflow electrons of p-i-n diodes under low current injection. However, when operating the devices at higher current densities, as low as ∼25 A/c⁢m 2 , we measure the emission of high-energy electrons. At variance with the observed hot electrons in light-emitting diodes (LEDs) using EES, the hot electrons generated in p-i-n diodes at our tested currents cannot be from eeh Auger-Meitner recombination due to the diodes' significantly lower carrier densities compared to those in LEDs. During our measurements, we observe the emission of accumulated electrons with energies ∼0.42 eV, ∼0.99 eV, ∼1.43 eV, and ∼2.32 eV above the conduction-band minimum (CBM) at various bias conditions, suggesting the existence of conduction-band features in GaN at these energies where electrons can be long-lived, such as satellite-valley minima and inflection points. We also measure incompletely relaxed hot electrons approaching energies 1.97 ± 0.13 eV and 2.94 ± 0.13 eV above the CBM, as the diodes are biased to high currents, suggesting at least some of the TAAR partaking defects have an energy level ≳1.97 eV and ≳2.94 eV away from either the conduction or valence band edges. Additionally, at our highest operating currents, we measure hot electrons with energies 3.28 ± 0.13 eV above the CBM, providing direct evidence of TAAR processes involving shallow impurities. This unexpected observation of TAAR in GaN p-i-n diodes spotlights the importance of further studies of defects in GaN and the necessity to incorporate the multi-phonon emission, radiative, and TAAR capture steps of defect-assisted recombination cycles into device modeling. Furthermore, this experiment demonstrates the applicability of the simplest semiconductor structures, p-i-n diodes, as a test bed to study the rich recombination physics of semiconductor materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic Heat Flow and Current Distribution Analysis in the Bottom Anode of an Electric Arc Furnace Using Fiber-Optic Sensors

A reliable method for monitoring bottom anode wear during DC Electric Arc Furnace (DC-EAF) operation is of critical importance for safe and efficient steel production. Underestimation of bottom wear poses a serious safety risk that must be avoided, while overestimation of bottom wear also poses challenges, as premature anode replacement is expensive and affects EAF productivity. Previously, we demonstrated that fiber-optic sensors can be successfully deployed to create a spatially distributed temperature map to monitor the health of the anode. The present work explores the heat flow and current density distribution in bottom anode pins to predict bottom wear, steel penetration events, and monitor refractory erosion. Small dynamic variations in pin temperature induced by joule heating during arcing also provide a means to observe local current flows in each pin. When mapped, these measurements provide a real-time view of the non-uniform and dynamic current flow in the bottom anode during EAF operation that can affect bottom wear.

Bottom Anode↗

Apparatus and method for dynamic acousto-elasticity technique measurements at simulated subsurface pressures

An apparatus (10) and method for performing nonlinear elasticity measurements using the dynamic acousto-elasticity technique (DAET) at simulated subsurface conditions in the laboratory, are described. The current state-of-the-art for measuring nonlinear elasticity parameters using DAET is limited to ambient pressure conditions on the bench-top. The present invention permits nonlinear parameter measurements at controlled sample internal fluid pore pressures (52) and external confining stress (44), (50) conditions.

Roberts, Peter M.↗

The Thermal and Kinematic Sunyaev–Zeldovich Effect in Galaxy Clusters and Filaments Using Multifrequency Temperature Maps of the Cosmic Microwave Background: A399–A401 Cluster Pair Case Study

We present a multifrequency and multi-instrument methodology to study the physical properties of galaxy clusters and cosmic filaments using cosmic microwave background observations. Our approach enables simultaneous measurement of both the thermal (tSZ) and kinematic Sunyaev–Zeldovich (kSZ) effects, incorporates relativistic corrections, and models astrophysical foregrounds such as thermal dust emission. We do this by jointly fitting a single physical model across multiple maps from multiple instruments at different frequencies, rather than fitting a model to a single Compton-y map. We demonstrate the success of this method by fitting the A399–A401 galaxy cluster pair and filament system using archival data from the Planck satellite and new, targeted deep data from the Atacama Cosmology Telescope, covering 11 different frequencies over 14 maps from 30 GHz to 545 GHz. Our tSZ results are consistent with previous work using Compton-y maps. We measure the line-of-sight peculiar velocities of the cluster–filament system using the kSZ effect and find statistical uncertainties on individual cluster peculiar velocities of ≲600 km s −1 , which are competitive with current state-of-the-art measurements. Additionally, we measure the optical depth of the filament component with a signal-to-noise of 8.5σ and reveal hints of its morphology. This modular approach is well-suited for application to future instruments across a wide range of millimeter and submillimeter wavebands.

Gill, Ajay S. [National Research Council of Canada↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

Electron-scale temperature gradients in kinetic equilibrium: MMS observations and Vlasov–Maxwell solutions

For an ideal gas, the notion of thermodynamic equilibrium requires that the system’s temperature be spatially uniform. We demonstrate that for a collisionless plasma, kinetic equilibrium can be achieved even in the presence of a temperature gradient. Motivated by recent MMS magnetopause observations of thin current layers exhibiting electron-scale temperature gradients, here we present an exact solution to the Vlasov-Maxwell system which accounts for the observed electron temperature gradient and reproduces much of the plasma’s spatial variation along one dimension. Furthermore, the current layer in the Vlasov-Maxwell model is self-consistently supported by a prominent crescent shaped electron velocity distribution that naturally arises due to the temperature transition, which agrees with the electron distribution structures measured by MMS during two asymmetric current layers encountered at the magnetopause.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast response High Altitude Laser Optical Sensor (HALOS) for atmospheric water and temperature measurements

Advanced instrumentation and sensing methods are the key factor in the determination of many climate science research problems. In this Phase I STTR a laser-based diagnostic system for atmospheric temperature and water concentrations measurements was developed, this system, HALOS – High Altitude Laser Optical Sensor, employs a mid-infrared (MIR) quantum cascade laser (QCL) of the distributed feedback variety (DFB) powered by a 100 kHz rep rate ramp modulated current profile which enables spectral profiling. Measurements made during Phase I showed that HALOS can surpass the available hygrometers refresh rates while offering superior accuracy (<4%) from the low Frost Point (Tfrost) of -110°C to dew points (Tdew) at 35°C while being able to encompass sub ppm concentration at altitude and supersaturated conditions at ground level. Readings from HALOS include temperature sensitivity on the order of 0.2°C and absolute humidity sensitivity (AH) on the order of 0.010 μmol/m 3 (0.18 mg/m 3 ) at a data output rate exceeding 1 kHz. HALOS can be easily integrable in existing Department of Energy (DOE) or National Oceanic and Atmospheric Administration (NOAA) conventional or remote operated aircraft having either a fixed or rotary wing.

54 ENVIRONMENTAL SCIENCES↗

Field Measurement Results of the 15 T Nb 3 Sn Dipole Demonstrator MDPCT1b

A 15 T Nb 3 Sn dipole with cos-theta-type coils was developed to demonstrate a possible magnet design for a post-LHC proton-proton Collider. The magnet has 4-layer coils with 60-mm aperture, and has graded current density between the inner and outer layers to maximize performance. The coils are constrained by vertically-split, thick iron laminations, connected by aluminum Iclamps, and a thick stainless-steel skin. The magnet was previously tested at the Vertical Magnet Test Facility (VMTF) at Fermilab with reduced pre-load, and achieved record 14.1 T fields at maximum current. Now the magnet has been reassembled with full pre-load and has been cryogenically retested at VMTF. We report here on the magnetic measurements results of these tests, including field strength, geometrical harmonics, coil magnetization, and iron saturation characteristics of the demonstrator.

43 PARTICLE ACCELERATORS↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

An octahedral Mach B-dot probe for 3D flows and magnetic fields in the edge of reversed field pinches

Measurements and simulations show that plasma relaxation processes in the reversed field pinch drive and redistribute both magnetic flux and momentum. To examine this relaxation process, a new 3D Mach B-dot probe has been constructed. This probe collects ion saturation currents through six molybdenum electrodes arranged on the flattened vertices of an octahedron made of boron nitride (BN). The ion saturation current flows through configurable voltage dividers for measurement and returns through one of six selectable return electrodes equally spaced along the 12 cm BN probe arm. In addition, the probe arm houses three B-dot magnetic pickup coils in the BN stalk immediately below to the octahedron, to measure the local magnetic field. Inserted in the Madison Symmetric Torus (MST) during deuterium discharges with 220 kA plasma current, density of 0.8 × 10 13 cm –3 , the probe collects ion saturation currents with sawtooth-like peaks correlated with relaxation events. This compact octahedral design fitting six Mach electrode surfaces within a 1 cm3 cube will enable future multi-point, multi-field probes compatible with the 1.5 in. ports of MST. Such probes will allow for flow circulation, current, and canonical vorticity to be calculated in the center of the finite difference stencil formed by the measurement locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutrino interaction measurements with the MicroBooNE and ArgoNeuT liquid argon time projection chambers

Abstract Precise modeling of neutrino interactions on argon is crucial for the success of future experiments such as the Deep Underground Neutrino Experiment (DUNE) and the Short-Baseline Neutrino (SBN) program, which will use liquid argon time projection chamber (LArTPC) technology. Argon is a large nucleus, and nuclear effects—both on the initial and final-state particles in the interaction—are expected to be large in neutrino–argon interactions. Therefore, measurements of neutrino scattering cross sections on argon will be of particular importance to future DUNE and SBN oscillation measurements. This article presents a review of neutrino–argon interaction measurements from the MicroBooNE and ArgoNeuT collaborations, using two LArTPC detectors that have collected data in the NuMI and Booster Neutrino Beams at Fermilab. Measurements are presented of charged-current muon neutrino scattering in the inclusive channel, the ‘0 $$\pi $$ π ’ channel (in which no pions but some number of protons may be produced), and single pion production (including production of both charged and neutral pions). Measurements of electron neutrino scattering are presented in the form of $$\nu _e+\bar{\nu }_e$$ ν e + ν ¯ e inclusive scattering cross sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron time of flight (nToF) detectors for inertial fusion experiments

Neutrons generated in Inertial Confinement Fusion (ICF) experiments provide valuable information to interpret the conditions reached in the plasma. The neutron time-of-flight (nToF) technique is well suited for measuring the neutron energy spectrum due to the short time (100 ps) over which neutrons are typically emitted in ICF experiments. By locating detectors 10s of meters from the source, the neutron energy spectrum can be measured to high precision. Here, we present a contextual review of the current state of the art in nToF detectors at ICF facilities in the United States, outlining the physics that can be measured, the detector technologies currently deployed and analysis techniques used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗

Measurements of Electron Beam-Induced Spin-Relaxation in Frozen-Spin Hydrogen-Deuteride (HD)

Targets of solid hydrogen-deuteride (HD) can be prepared in a frozen-spin state with spin relaxation times (T1) in excess of a year. The present work has studied their potential use in experiments with electron beams. Polarization relaxation rates have been measured during exposure to sub-nanoAmp currents of 9.7 MeV electron beams from the recently commissioned Upgraded Injector Test Facility (UITF) at Jefferson Lab (JLab). These UITF measurements can be used to anticipate the expected performance at the GeV energies typical of JLab experiments, since the energy deposition in a target is almost independent of beam energy. An in-beam dilution refrigerator equipped with superconducting solenoids has been used to maintain solid HD samples at ?0.1 K and ?1 tesla, and internal NMR coils have been used to monitor hydrogen polarization. Spin-relaxation in two frozen-spin targets, with initial H-polarizations of 40% and 34%, have been tracked while exposed to beams under varying conditions of current, dose, beam duty factor and temperature. At a fixed accumulated dose, the spin-relaxation rates drop with current, suggesting depolarization by the charge cloud of the beam. Imposing a duty factor on the otherwise continuous UITF beam, with forced millisecond scale gaps, has shown no obvious correlation to polarization loss rates. After an accumulated dose of ?2 ?C/cm2, beam-off spin-relaxation rates drop from their immeasurably long pre-irradiation values to the order of weeks (with beam-on T1 values typically an order of magnitude shorter), reflecting a buildup of paramagnetic charge centers within the HD lattice. The accumulated polarization loss was approximately proportional to dose in both targets, dropping to 1/e of their initial values after ?6 ?C/cm2. Thermal equilibrium polarizations of targets not in the frozen-spin state (with intentionally short T1) have been used to deduce the in situ temperature of solid HD while under electron bombardment. A model for depolarization by beam-associated paramagnetic impurities largely accounts for the data, and suggests that improvements in heat removal could lead to significant increases in the in-beam T1.

O'Connell, Thomas↗

Characteristics of Ultralow Aspect Ratio Toroidal Plasmas and Non-Solenoidal Startup and Edge Stability Studies at Near-Unity Aspect Ratio (Final Report)

This grant supported a long-term research and development program to explore the physics and technology of spherical tokamak (ST) plasma behavior at near-unity aspect ratio ( A ). The PEGASUS Toroidal Experiment is a university-scale ( R ) ~ 0.40 m, α ~ .35 m, I p ≤ 0.3 MA, B T ≤ 0.15 T) experiment that accesses A → 1, to provide large values of the normalized plasma current, I N = I p /α B T , or equivalently the toroidal field utilization factor I p / I TF . The research activities focused on: 1) developing the technique of Local Helicity Injection (LHI) as a viable means of initiating and growing an ST plasma without the use of a central solenoid; 2) exploring the equilibrium and stability properties of spherical tokamak plasmas at extremely low aspect ratio; and 3) obtaining new insights in the properties of the enhanced confinement H-mode regime at A ~ 1. The initial (Phase I) facility employed a unique high-stress central solenoid Ohmic for current drive and heating with simple magnet current waveforms. A subsequent major upgrade (Phase II) offered more flexible control of the plasma evolution along with a powerful LHI system for plasma initiation, heating and sustainment. The LHI technique consists of injection of high-density current streams into vacuum toroidal and vertical magnetic fields. These streams become unstable and support magnetic reconnection to allow the system to relax into a tokamak-like magnetic configuration. This program focused on: 1) development of electron current sources that provide sufficiently high injection currents in the challenging edge plasma region; 2) validation of theoretical limits to achievable I p arising from magnetic helicity and energy conservation plus absolute limits arising from relaxation to a minimal energy states; 3) tests of a power balance model to describe the evolution of the plasma current I p (t); and 4) study of magnetic fluctuations and their role in the I p evolution. This culminated in the production of toroidal currents of I p ≥ 0.2 MA with only ~8 kA of injected current. Operation with Ohmic induction alone in Phase I created plasmas with soft limits on the achievable I p and field utilization ( I p / I TF ~ 1) due to the onset of large low-order (2/1 or 3/2) internal resonant tearing modes. With the expanded capabilities in Phase II operation, methods employed to mitigate those modes and achieve I p / I TF > 1 were: 1) I TF ramp-downs; 2) non-solenoidal startup via LHI; and 3) extremely low I TF Ohmic operations assisted by LHI current injector pre-ionization. Extensive use of LHI-driven startup and drive for non-solenoidal operation produced favorable current profiles to stably operate tokamak plasmas with unprecedentedly high I N = I p / aB T ~ 15 and I p / I TF > 2. With strong reconnection-driven anomalous ion heating, this in turn provided access to tokamak plasmas with B t up to 100%, a world record 2 times higher than that previously achieved in advanced or spherical tokamaks. This high B t regime had a large fraction (~50%) of the plasma volume in a region of an absolute minimum- B configuration. The MHD stability limit in this regime was the ideal external kink mode without a stabilizing wall. These results provided the first demonstration of access to tokamak plasmas with very high B t , high i N , high elongation κ, and low internal inductance ℓ i , and as such served as a proof-ofprinciple for access to this long-sought ST regime. The naturally low B T needed for stability at A ≤ 1.2 reduces the L-H mode power threshold, P LH , so that H-mode plasmas were achieved with Ohmic heating alone. The power threshold for the transition to the H-mode regime was found to be 10× the accepted values from the ITER international scaling, confirming initial trends indicated by experiments on MAST and NSTX, and suggesting that the physics behind this transition is not yet fully understood. The density dependence of the transition and the observed insensitivity to whether the plasma is bounded by a limiter or magnetic divertor are consistent with the recent FM 3 model. Multiple unstable toroidal magnetic modes were measured during ELM (Edge Localized Mode) crashes, with generally lower toroidal mode numbers than seen at higher A , which was attributed to the larger peeling mode instability drive at low A . First-ever edge current profile measurements through an ELM crash showed current-carrying filaments were generated, as seen in ELM simulations and in electromagnetic blob transport theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring Cosmological Parameters with Type Ia Supernovae in redMaGiC Galaxies

Abstract Current and future cosmological analyses with Type Ia supernovae (SNe Ia) face three critical challenges: (i) measuring the redshifts from the SNe or their host galaxies; (ii) classifying the SNe without spectra; and (iii) accounting for correlations between the properties of SNe Ia and their host galaxies. We present here a novel approach that addresses each of these challenges. In the context of the Dark Energy Survey (DES), we analyze an SN Ia sample with host galaxies in the redMaGiC galaxy catalog, a selection of luminous red galaxies. redMaGiC photo- z estimates are expected to be accurate to σ Δ z /(1+ z ) ∼ 0.02. The DES-5YR photometrically classified SN Ia sample contains approximately 1600 SNe, and 125 of these SNe are in redMaGiC galaxies. We demonstrate that redMaGiC galaxies almost exclusively host SNe Ia, reducing concerns relating to classification uncertainties. With this subsample, we find similar Hubble scatter (to within ∼0.01 mag) using photometric redshifts in place of spectroscopic redshifts. With detailed simulations, we show that the bias due to using redMaGiC photo- z s on the measurement of the dark energy equation of state w is up to Δ w ∼ 0.01–0.02. With real data, we measure a difference in w when using the redMaGiC photo- z s versus the spec- z s of Δ w = 0.005. Finally, we discuss how SNe in redMaGiC galaxies appear to comprise a more standardizable population, due to a weaker relation between color and luminosity ( β ) compared to the DES-3YR population by ∼5 σ . These results establish the feasibility of performing redMaGiC SN cosmology with photometric survey data in the absence of spectroscopic data.

79 ASTRONOMY AND ASTROPHYSICS↗

Ponderomotive force driven density modifications parallel to B on the LAPD

The ponderomotive force has previously been identified as a possible driver of observed density modifications close to radio frequency actuators during operation. This nonlinear force redistributes density in regions of gradients in the magnitude of an oscillating electric field and describes the influence of the fast time scale RF wave dynamics on slow time scale plasma transport. Depletion of the saturation current (a proxy for the density) measured at the Large Plasma Device (LAPD) was 30–35% during ion cyclotron range of frequencies operation. A coupled 1D plasma transport and cold plasma frequency domain wave solver was developed to self-consistently describe ponderomotive effects and was used to compare with results obtained from the LAPD experiment. The scaled current density driver for the wave model yielded an RF B field in close agreement with two components of the experimental data. However, the 1D parallel model did not accurately reproduce the amplitude or spatial distribution observed in experimental measurements of By. Within the limitations of the 1D model, initial simulation results showed that the ponderomotive force depleted up to 8% for high power (1 MW) and around 1% for the experimental power of 120 kW. This could suggest that the ponderomotive force is not the main driver of density modification for the LAPD experiments presented in this paper. Higher fidelity tools of at least 2D will be required to give a more realistic description of the RF E fields and the effect of the ponderomotive force on the LAPD.