Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Testing of High-Lift Common Research Model at Takeoff Configurations

The 10% scale High-Lift Common Research Model (CRM-HL) was tested in the NASA Langley 14- by 22-Foot Subsonic Tunnel (14x22) in support of the NASA Advanced Air Transport Technology (AATT) Project. The main objective of the wind tunnel test was to improve the aerodynamic performance of a representative aircraft model during takeoff operations using localized active flow control (AFC). This approach involves the application of AFC concepts locally to a relatively small region; therefore, it has the potential to cause minimal architectural change to current aircraft configurations. In addition, the power requirements of localized AFC could be supplied with onboard air resources. Recent exploratory studies identified the aileron as a target area for improving lift-to-drag ratio using localized AFC concepts. The idea is to deflect the ailerons beyond their nominal deflection angles and use AFC to reduce flow separation that occurs at larger aileron deflections. Several AFC concepts with different configurations were evaluated with the goal of achieving high-lift performance improvement. The assessment of AFC configurations is reported in a companion paper. The focus of the current paper is to report the data relevant to the CRM-HL takeoff configurations and establish a reference case for localized AFC application. Three takeoff configurations —reference, nominal, and high-lift improved—are documented. These takeoff configurations are obtained by varying aileron deflection. Wind tunnel measurements including surface static pressures and force and moment data are presented. In addition, surface tuft flow visualization, mainly on the aileron, is provided to understand the flow characteristics developed over the aileron during takeoff.

Lift-to-Drag↗

Testing of High-Lift Common Research Model at Takeoff Configurations

The 10% scale High-Lift Common Research Model (CRM-HL) was tested in the NASA Langley 14- by 22-Foot Subsonic Tunnel (14x22) in support of the NASA Advanced Air Transport Technology (AATT) Project. The main objective of the wind tunnel test was to improve the aerodynamic performance of a representative aircraft model during takeoff operations using localized active flow control (AFC). This approach involves the application of AFC concepts locally to a relatively small region; therefore, it has the potential to cause minimal architectural change to current aircraft configurations. In addition, the power requirements of localized AFC could be supplied with onboard air resources. Recent exploratory studies identified the aileron as a target area for improving lift-to-drag ratio using localized AFC concepts. The idea is to deflect the ailerons beyond their nominal deflection angles and use AFC to reduce flow separation that occurs at larger aileron deflections. Several AFC concepts with different configurations were evaluated with the goal of achieving high-lift performance improvement. The assessment of AFC configurations is reported in a companion paper. The focus of the current paper is to report the data relevant to the CRM-HL takeoff configurations and establish a reference case for localized AFC application. Three takeoff configurations —reference, nominal, and high-lift improved—are documented. These takeoff configurations are obtained by varying aileron deflection. Wind tunnel measurements including surface static pressures and force and moment data are presented. In addition, surface tuft flow visualization, mainly on the aileron, is provided to understand the flow characteristics developed over the aileron during takeoff.

Wind tunnel test↗

Bipropellant shut-off valve

An advanced design of an all metal, fast response, bipropellant, shut-off valve for use on long duration space missions is reported. The valve provides the flow control capability for a 1,000 lb thrust, bipropellant engine using oxygen difluoride and diborane as propellants. The shutoff seal selection is a soft-on-hard metal concept. The soft seal is a spherical shell that seats against a hard conical seat. Beryllium copper and beryllium nickel seals were selected to seal against an electrolyzed Inconel 718 seat. Poppet shaft sealing is achieved by use of hydroformed, Inconel 718 bellows. Two valve assemblies were fabricated and subjected to a series of tests including leak, response time, flow capacity, dry cycles, water cycles, liquid nitrogen cycles, liquid fluorine cycles, and lead-lag operation cycles. These tests demonstrated the ability of the valve to meet design goals.

Smith, J. V.↗

The effects of wall surface defects on boundary-layer transition in quiet and noisy supersonic flow

The design of supersonic vehicles with laminar flow control and vehicles such as the Space Shuttle requires information on allowable transition tolerances to fabrication defects such as discrete surface roughness and waviness. A relatively large data base on the effects of discrete roughness on transition exists for subsonic and supersonic speeds. The existing supersonic wind tunnel transition data are contaminated by wind tunnel noise emanating from the turbulent boundary layers on the nozzle walls. Roughness and waviness transition data obtained in a quiet Mach 3.5 supersonic wind tunnel are compared with those obtained in conventional noisy flows.

Morrisette, E. Leon↗

Micro-Ramps for External Compression Low-Boom Inlets

The application of vortex generators for flow control in an external compression, axisymmetric, low-boom concept inlet was investigated using RANS simulations with three-dimensional (3-D), structured, chimera (overset) grids and the WIND-US code. The low-boom inlet design is based on previous scale model 1- by 1-ft wind tunnel tests and features a zero-angle cowl and relaxed isentropic compression centerbody spike, resulting in defocused oblique shocks and a weak terminating normal shock. Validation of the methodology was first performed for micro-ramps in supersonic flow on a flat plate with and without oblique shocks. For the inlet configuration, simulations with several types of vortex generators were conducted for positions both upstream and downstream of the terminating normal shock. The performance parameters included incompressible axisymmetric shape factor, separation area, inlet pressure recovery, and massflow ratio. The design of experiments (DOE) methodology was used to select device size and location, analyze the resulting data, and determine the optimal choice of device geometry. The optimum upstream configuration was found to substantially reduce the post-shock separation area but did not significantly impact recovery at the aerodynamic interface plane (AIP). Downstream device placement allowed for fuller boundary layer velocity profiles and reduced distortion. This resulted in an improved pressure recovery and massflow ratio at the AIP compared to the baseline solid-wall configuration.

Rybalko, Michael↗

Flow Disturbance Characterization Measurements in the National Transonic Facility

Recent flow measurements have been acquired in the National Transonic Facility (NTF) to assess the unsteady flow environment in the test section. The primary purpose of the test is to determine the feasibility of the NTF to conduct laminar-flow-control testing and boundary-layer transition sensitive testing. The NTF can operate in two modes, warm (air) and cold/cryogenic (nitrogen) test conditions for testing full and semispan scaled models. The warm-air mode enables low to moderately high Reynolds numbers through the use of high tunnel pressure, and the nitrogen mode enables high Reynolds numbers up to flight conditions, depending on aircraft type and size, utilizing high tunnel pressure and cryogenic temperatures. NASA's Environmentally Responsible Aviation (ERA) project is interested in demonstrating different laminar-flow technologies at flight-relevant operating conditions throughout the transonic Mach number range and the NTF is well suited for the initial ground-based demonstrations. Roll polar data at selected test conditions were obtained to look at the uniformity of the flow disturbance field in the test section. Data acquired from the rake probes included mean total temperatures, mean and fluctuating static/total pressures, and mean and fluctuating hot-wire measurements. . Based on the current measurements and previous data, an assessment was made that the NTF is a suitable facility for ground-based demonstrations of laminar-flow technologies at flight-relevant conditions in the cryogenic mode.

King, Rudolph A.↗

Robust, Flexible and Lightweight Dielectric Barrier Discharge Actuators Using Nanofoams/Aerogels

Robust, flexible, lightweight, low profile enhanced performance dielectric barrier discharge actuators (plasma actuators) based on aerogels/nanofoams with controlled pore size and size distribution as well as pore shape. The plasma actuators offer high body force as well as high force to weight ratios (thrust density). The flexibility and mechanical robustness of the actuators allows them to be shaped to conform to the surface to which they are applied. Carbon nanotube (CNT) based electrodes serve to further decrease the weight and profile of the actuators while maintaining flexibility while insulating nano-inclusions in the matrix enable tailoring of the mechanical properties. Such actuators are required for flow control in aeronautics and moving machinery such as wind turbines, noise abatement in landing gear and rotary wing aircraft and other applications.

Sauti, Godfrey↗

Ignition and combustion characteristics of metallized propellants

Shakedown and calibration of the experimental apparatus designed to study secondary atomization and ignition characteristics of aluminum slurry propellants was begun and nears completion. The burner was tested over an array of equivalence ratios and oxygen mass fractions to determine the permissible range of operating conditions. A burner flow control system was designed and fabricated which permits independent control of flame stoichiometry and oxidant O2 concentrations. The Sun slurry formulation was selected as the base for initial testing. Laser beam waists at the focal volume of the single particle sizing system were determined to be 396 microns for the Ar-ion and 81 microns for the He-Ne laser. Size calibrations using pinholes were completed and compared to Mie theory for light scattering from particles. A vibrating office droplet generator was used to test the single particle sizing system dynamically by producing a water droplet laden gas flow. The data acquisition and analysis programming was completed and testing is in progress. From initial results, the particle sizing, atomization and ignition detection systems appear to be performing as expected.

Turns, S. R.↗

Görtler Instability and Its Control via Surface Suction over an Axisymmetric Cone at Mach 6

The characteristics of Görtler instability over an axisymmetric cone with an aft concave section are studied via linear and nonlinear instability analysis and direct numerical simulations. Several options for the cone geometry have been investigated numerically, subject to a fixed forecone section and constraints on the maximum cone diameter, overall cone length, and minimum N-factor for the most amplified Görtler modes. Computations show that it is possible to design a cone with a peak N-factor of Nmax > 8 at the target Reynolds number of 12.1×10(exp 6) per meter, corresponding to the maximum quiet Reynolds number in the Boeing/AFOSR Mach-6 Quiet Tunnel at Purdue University. Direct numerical simulations show that an array of roughness elements corresponding to a peak roughness height of 0.1006 mm at the center can excite Görtler vortices that evolve into sufficiently strong streamwise streaks that may break down via high-frequency secondary instability. Thus, the selected axisymmetric configuration of interest should provide an acceptable baseline to investigate the feasibility of several aspects of laminar-flow control via boundary-layer suction. The apparatus that is being used for measurements in the Boeing/AFOSR Quiet Tunnel is described, along with some preliminary experimental results.

Gortler vortices↗

Pilot-Scale CFP Commissioning: Creative Problem Solving and Lessons Learned

We have commissioned a pilot-scale, ex-situ catalytic fast pyrolysis (CFP) reactor system in the Thermal and Catalytic Process Development Unit (TCPDU) at the National Renewable Energy Laboratory. The FCC-style CFP system, including a riser and continuous regeneration, was added to the existing half-ton-per-day biomass fast pyrolysis unit and was designed to run a zeolite-type catalyst. The system is unique due to its scale and catalyst flow control scheme. As the design of this system was informed by early data from a bench-scale reactor, several technical scale-up challenges had to be overcome. Additionally, physical constraints and the complexities of biomass vapors required and inspired creative solutions. This talk will discuss the specific challenges we found and addressed, including an oxygen deficiency in the regenerator and plugging in the exit streams. We explored several options for increasing oxygen availability and selected a cyclone-catalyst return design on the exit line so we could increase air flow through the regenerator. We found that hot gas filtration is essential in any exit streams containing water vapor and trace amounts of catalyst; any combination of catalyst and condensate quickly makes mud that plugs equipment and severely limits run time. Duplicate filters are also required to extend run time. Most of the equipment and solutions were designed and installed by our team of engineers and technicians, working closely together in an iterative process to design, install, operate, then redesign. Collaborations with other national laboratories with computational fluid dynamics expertise helped inform designs and identify creative solutions to these scale-up challenges. Ultimately, data from the reactor system will be used to validate a comprehensive kinetic model of CFP that can be used to better design and inform new systems at various scales.

09 BIOMASS FUELS↗

Sensor for Direct Measurement of the Boundary Shear Stress in Fluid Flow

The formation of scour patterns at bridge piers is driven by the forces at the boundary of the water flow. In most experimental scour studies, indirect processes have been applied to estimate the shear and normal stress using measured velocity profiles. The estimations are based on theoretical models and associated assumptions. However, the turbulence flow fields and boundary layer in the pier-scour region are very complex. In addition, available turbulence models cannot account accurately for the bed roughness effect. Direct measurement of the boundary shear and normal stress and their fluctuations are attractive alternatives. However, this approach is a challenging one especially for high spatial resolution and high fidelity measurements. The authors designed and fabricated a prototype miniature shear stress sensor including an EDM machined floating plate and a high-resolution laser optical encoder. Tests were performed both in air as well as operation in water with controlled flow. The sensor sensitivity, stability and signal-to-noise level were measured and evaluated. The detailed test results and a discussion of future work will be presented in this paper.

sheer stress↗

Sensor for Direct Measurement of the Boundary Shear Stress in Fluid Flow

The formation of scour patterns at bridge piers is driven by the forces at the boundary of the water flow. In most experimental scour studies, indirect processes have been applied to estimate the shear and normal stress using measured velocity profiles. The estimations are based on theoretical models and associated assumptions. However, the turbulence flow fields and boundary layer in the pier-scour region are very complex. In addition, available turbulence models cannot account accurately for the bed roughness effect. Direct measurement of the boundary shear and normal stress and their fluctuations are attractive alternatives. However, this approach is a challenging one especially for high spatial resolution and high fidelity measurements. The authors designed and fabricated a prototype miniature shear stress sensor including an EDM machined floating plate and a high-resolution laser optical encoder. Tests were performed both in air as well as operation in water with controlled flow. The sensor sensitivity, stability and signal-to-noise level were measured and evaluated. The detailed test results and a discussion of future work will be presented in this paper.

shear stress↗

Hydrogen Leak Modeling for Development of Smart Distributed Monitoring Under Unintended Releases

Hydrogen is a versatile and clean energy carrier that can be produced from various renewable sources such as wind, solar, and hydropower. Hydrogen has the potential to play a crucial role in decarbonizing industrial processes that are currently reliant on fossil fuels and provide long-duration and/or seasonal energy storage to enable electricity decarbonization. Hydrogen can also be used as a fuel for fuel cell vehicles, providing a zero-emission alternative to traditional internal combustion engines. DOE launched the Hydrogen Energy Earthshot (Hydrogen Shot) in June 2021 to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). While promising, Hydrogen is highly-flammable, and in the presence of oxygen, it can form explosive mixtures. . Therefore, understanding leak scenarios is essential to evaluate and mitigate the safety risks associated with potential hydrogen leaks. An increased understanding of leak behavior, and having tools to model leaks, can help assess how hydrogen would disperse in different environments, influencing emergency response plans and safety measures, and identify potential issues with materials and design systems that can withstand the challenges posed by hydrogen. Recently, researchers have attempted to study hydrogen leaks for development of risk management strategies. However, the focus has been on closed or semi-closed spaces like storage rooms, vehicles, garages, and fueling stations - all promising locations for future hydrogen infrastructure. In this presentation, the modeling environment extends the span of research further by modeling hydrogen leak in an outdoor, open space. We will present the key challenges with modeling hydrogen leaks in an uncontrollable environment, how they were handled, and how modeling results informed sensor selection and placement. A Hydrogen research facility at the National Renewable Energy Laboratory (NREL) was used as a case study to model hydrogen leaks. In the future, Hydrogen wide area detection methodologies will be developed and tested at this site to monitor for unintended and operational hydrogen releases. The data generated from modeling will be used to develop a predictive model to detect hydrogen leak location based on concentration measured by sensors in this open space. Furthermore, the facility was also chosen because controlled hydrogen releases can be performed. A computational fluid dynamics (CFD) based modeling approach was taken to model hydrogen leak. The full-scale hydrogen facility was modeled with a large ambient domain. The electrolyzer at the facility can produce a controlled release rate of 27 kg-H2/hr. Site-specific atmospheric and weather condition data such as wind direction, wind speed at various altitudes, and temperature were used as inputs to the model. To capture the variability of weather conditions, a subset of the weather conditions experienced during daytime hours without precipitation over the course of three months was generated; using established data clustering techniques, a total of 100 condition sets were chosen. The results show statistical distributions and ranges of hydrogen concentrations at locations throughout the domain. These distributions are compared to experimental data from a constant mass flow, controlled hydrogen release at the facility. The stochastic wind conditions of the release make direct validation difficult, therefore, statistical comparison approaches were used. Wind conditions are found to significantly impact the release behavior, including direction and concentration. Sensor selection and placement is proposed for the facility and is now based on release behavior predicted for the facility given its weather patterns; this is much more informed than without the modeling results. The methodology and analysis procedure can be translated to other facilities using modified geometries and site-specific weather conditions. Hydrogen holds great promise as a renewable energy fuel, but ensuring safety in its production, storage, and use is paramount. Studying potential leak scenarios in an open space will help develop sensors to detect hydrogen on a large spectrum of concentration and eventually build a smart distributed monitoring system.

CFD↗

CFD and Experimental Data Comparisons for Conventional and AFC-Enabled CRM High-Lift Configurations

Numerical simulations have been performed for a simplified high-lift (SHL) version of the Common Research Model (CRM) configuration, where the Fowler flaps of a representative conventional high-lift (CRM-HL) configuration are replaced by a set of simple hinged flaps. These hinged flaps are equipped with integrated modular active flow control (AFC) cartridges on the suction surface of the flap shoulder, and the resulting geometry is known as the CRM-SHL-AFC configuration. The main objective is to make use of AFC devices on the CRM-SHL-Configuration to produce the aerodynamic performance (lift) comparable to that of the CRM-HL configuration over a large angle of attack range encompassing maximum lift conditions. For comparison purposes, computations are also per-formed for the CRM-HL configuration. In the current paper, PowerFLOWR©, a CFD code based on the Lattice Boltzmann method (LBM), is used to simulate the entire flow field associated with the CRM-SHL-AFC configuration equipped with a combination of two different types of AFC actuators. The transonic version of the PowerFLOWR© code that has been validated for high-speed flows is used to simulate the flow field generated by the high-momentum actuators required to mitigate reversed flow regions on the suction surfaces of the main wing and the flap. This study is focused on the AFC systems and actuator arrangements that had emerged based on the parametric studies conducted previously at the nominal landing condition. Comparisons of the numerical solutions for lift and surface pressures are presented here with the experimental data, demonstrating the usefulness of CFD for predicting the flow field and lift characteristics of AFC-enabled high-lift configurations over a broad angle of attack range. The numerical solutions predict the expected trends in aerodynamic forces with angle of attack variation.

Veer N Vatsa↗

Potential-induced wetting and dewetting in hydrophobic nanochannels for mass transport control

Wetting and dewetting transitions play a central role in controlling the hydrophobicity of the lining of biological channels in order to regulate aqueous solution permeation. Understanding of the operational characteristics of biological nanochannels led to experimental efforts to mimic their behavior and to achieve potential-induced, repeatedly-switchable wettability transitions in synthetic nanochannels in the early 2010s. Since then, research has identified conditions needed to produce reversible wettability transitions using a number of different environmental stimuli - such as light, pH, and electrostatic charge - in addition to potential. Furthermore, nascent understanding of the underlying phenomena in synthetic nanochannels was rapidly followed by practical applications, including oil-water separations, drug release, and electroactive flow control based on switchable wettability. Furthermore, more practical applications are being developed continuously, as the physical and chemical principles that govern hydrophobic gating at the nanoscale are further elucidated, making it possible to exploit wettability as a design element in nanofluidic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methodology for object-oriented real-time systems analysis and design: Software engineering

Successful application of software engineering methodologies requires an integrated analysis and design life-cycle in which the various phases flow smoothly 'seamlessly' from analysis through design to implementation. Furthermore, different analysis methodologies often lead to different structuring of the system so that the transition from analysis to design may be awkward depending on the design methodology to be used. This is especially important when object-oriented programming is to be used for implementation when the original specification and perhaps high-level design is non-object oriented. Two approaches to real-time systems analysis which can lead to an object-oriented design are contrasted: (1) modeling the system using structured analysis with real-time extensions which emphasizes data and control flows followed by the abstraction of objects where the operations or methods of the objects correspond to processes in the data flow diagrams and then design in terms of these objects; and (2) modeling the system from the beginning as a set of naturally occurring concurrent entities (objects) each having its own time-behavior defined by a set of states and state-transition rules and seamlessly transforming the analysis models into high-level design models. A new concept of a 'real-time systems-analysis object' is introduced and becomes the basic building block of a series of seamlessly-connected models which progress from the object-oriented real-time systems analysis and design system analysis logical models through the physical architectural models and the high-level design stages. The methodology is appropriate to the overall specification including hardware and software modules. In software modules, the systems analysis objects are transformed into software objects.

Schoeffler, James D.↗

Design and testing of a high power spacecraft thermal management system

The design and test results are presented of an ammonia hybrid capillary pumped loop thermal control system which could be used for heat acquisition and transport on future large space platforms and attached payloads, such as those associated with the NASA Space Station. The High Power Spacecraft Thermal Management System (HPSTM) can operate as either a passive, capillary pumped two phase thermal control system, or, when additional pressure head is required, as a mechanically pumped loop. Testing has shown that in the capillary mode, the HPSTM evaporators can acquire a total heat load of between 600 W and 24 kW, transported over 10 meters, at a maximum heat flux density of 4.3 W/sq cm. With the mechanical pump circulating the ammonia, a heat acquisition potential of 52 kW was demonstrated for 15 minutes without an evaporator failure. These results represent a significant improvement over the maximum transport capability previously displayed in other capillary systems. The HPSTM system still retains the proven capillary capabilities of heat load sharing and flow control between evaporator plates, rapid power cycling, and nonuniform heating in both the capillary and hybrid operating modes.

Mccabe, Michael E., Jr.↗