Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Color”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Developing a Hail and Wind Damage Swath Event Database from Daily MODIS True Color Imagery and Storm Reports for Impact Analysis and Applications

Hail and damaging winds are two threats associated with intense and severe thunderstorms that traverse the Midwest and Great Plains during the primary growing season. In certain severe thunderstorm events, large swaths of agricultural crops are impacted, allowing the damage to be viewed from multiple satellite remote sensing platforms. Previous studies have focused on analyzing individual hail and wind damage swaths (HWDSs) using satellite remote sensing, but these swaths have never been officially archived or documented. This lack of documentation has made it difficult to analyze the spatial extent and temporal frequency of HWDSs from year to year. This study utilizes daily true color imagery from MODIS aboard NASA’s Terra and Aqua satellites and daily local storm reports from the Storm Prediction Center to build a database of HWDSs occurring in the months of May through August, for years 2000 through 2020. This database identified 1,646 HWDSs in 12 states throughout the Midwest and Great Plains, confirmed through a combination of archived severe weather warnings, radar information, and official storm reports. For each entry in the HWDS database, a geospatial outline is provided along with the most likely date of first visible damage from MODIS imagery as well as the physical characteristics and time of occurrence estimated from available warnings. This study also provides a summary of the radar characteristics for a portion of the database. This database will further the understanding of severe weather damage by hail and wind to agriculture to help understand the frequency of these events and assist in mapping the impacted areas.

Climatology↗

Optical and Detector Design of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem mission is a hyperspectral imager with high SNR, precision and dynamic range, and with a very low striping artifact level in the 342-887 nm wavelength range with a spectral resolution of 5 nm in 2.5 nm steps, providing a significant technological advancement over previous ocean imagers. To achieve this, OCI is designed with specialized optical imaging and opto-electronic detection systems that push the boundaries of several state-of-the-art technologies. This paper provides an overview of these systems together with their achieved performances and discussions of their key design challenges.

Remote sensing↗

PACE Water Resources: Demonstrating the Use of NASA's PACE Hyperspectral Ocean Color Instrument Data for Enhanced Coastal Management

This project developed tools to support the future use of Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) hyperspectral imagery in water resource monitoring and research by NASA DEVELOP teams and members of the PACE applications community. We sought to address a need for support in processing and visualizing hyperspectral PACE Ocean Color Instrument (OCI) data among researchers and decision-makers working in coastal water quality management and harmful algal bloom (HAB) monitoring. To supplement the day of simulated PACE imagery available, we used Aqua MODIS earth observations with Level 3 processing from March 2022 to build a Python graphical user interface (GUI) for visualizing ocean biogeochemical parameters relevant to the early detection and monitoring of HABs. We used simulated PACE OCI Level 2 data derived from the Python Top of Atmosphere Simulation Tool (PyTOAST) to build Jupyter Notebooks for band subset and selection. The Level 3 PACE Viewer components support users with quick visualizations as well as the creation of geoTIFFs and time-series. The Level 2 Jupyter Notebooks address users’ concerns over the volume and complexity of hyperspectral imagery. The PACE Viewer is useful for visual inspection and netCDF data processing but should not be used for geospatial analysis. Once PACE launches, this tool will alleviate the technical burdens of working with hyperspectral data and support the early detection and monitoring of HABs using PACE satellite imagery.

Python Top of Atmosphere Simulation Tool↗

A Tuned Ocean Color Algorithm for the Arctic Ocean: A Solution for Waters With High CDM Content

The Arctic Ocean (AO) is the most river-influenced ocean. Located at the land-sea interface wherein phytoplankton blooms are common, Arctic coastal waterbodies are among the most affected regions by climate change. Given phytoplankton are critical for energy transfer supporting marine food webs, accurate estimation of chlorophyll a concentration (Chl), which is frequently used as a proxy of phytoplankton biomass, is critical for improving our knowledge of the Arctic marine ecosystem and its response to the ongoing climate change. Due to the unique and complex bio-optical properties of the AO, efforts are still needed to obtain more accurate Chl estimates, especially for coastal waters with high colored detrital material (CDM) content. In this study, we optimized the the Garver-Siegel-Maritorena (GSM) algorithm, using an Arctic bio-optical dataset comprised of seven wavelengths (the original GSM wavelengths plus 625 nm). Results suggested that our tuned algorithm, denoted GSMA, outperformed an alternative AO GSM algorithm denoted AO.GSM, but the accuracy of Chl estimates was only improved by 8%. In addition, GSMA showed appreciable robustness when assessed using a satellite image and two non-Arctic coastal datasets.

Arctic↗

Pre-Launch Characterization of the Hyperspectral Ocean Color Instrument on NASA’s Pace Mission

Launched in February 2024, the Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. Like its predecessors, OCI provides two day global coverage of top-of-atmosphere radiances. Unlike its predecessors, OCI covers a spectral range from 340 nm to 2260 nm. Below 900 nm, OCI provides hyperspectral radiances sampled every 2.5 nm or 1.25nm, with a bandwidth of 5 nm for each channel. Its spatial resolution is about 1.2km. The high radiometric accuracy of OCI was made possible by a thorough and extensive prelaunch characterization campaign, conducted at NASA’s Goddard Space Flight Center. This presentation describes the prelaunch radiometric characterization (approach and results) of OCI, such as e.g. the linearity correction, signal to noise ratio, polarization, IFOV, relative spectral response, radiometric gain, temperature sensitivity, optical crosstalk, and response versus scan angle.

Gerhard Meister↗

Spectral Measurement Errors due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a hyperspectral imager with a spatial resolution of 1km x 1km and spectral resolution of 5nm in 2.5nm steps over 320-890nm. The detection system is based on two Charge-Coupled Devices (CCDs) operating in Time Delay Integration (TDI) mode to achieve high signal-to-noise ratio. The front-end optical imager is a rotating mirror-based system that images the ground-scene onto a slit with a field of view of 16km x 1km. The slit-image is re-imaged and wavelength dispersed on the CCDs. As the ground-scene moves through the slit, it moves along the CCD columns as charge is moved along with it. The accumulated charge at the end of each column is collected in a serial pixel. Each of the 16 CCD outputs read out 32 columns of the same ground scene spaced 0.625nm apart. The 32-pixel serial register is swiftly read out before the next TDI cycle. The telescope is spinning at 5.77Hz to achieve the required spatial resolution. This results in a serial pixel readout speed of 8.5MHz. Each serial read-cycle goes through a reset and video period that are each sampled to create a low-noise correlated double sample value. This only allows 59ns for the reset and video to be asserted and settled before sampling. Due to the short time period, the response of the CCD exhibits serial pixel-to-pixel readout interference as the reset and video signals do not have time to fully settle before sampling. Each serial pixel value therefore has a dependence on the value of the preceding pixel value. This leads to a spectral measurement error of up to 0.3%. We explain the operation of the detection system, the behavior of the interference and the resulting wavelength error with results from ground testing and on-orbit characterization.

Ulrik B Gliese↗

Spectral and Spatial Dependencies in the Validation of Satellite-Based Aerosol Optical Depth from the Geostationary Ocean Color Imager Using the Aerosol Robotic Network

The regional and global scale of aerosols in the atmosphere can be quantified using the aerosol optical depth (AOD) retrieved from satellite observations. To obtain reliable satellite AODs, conducting consistent validations and refining retrieval algorithms are crucial. AODs and Ångström exponents (AEs) measured with the aerosol robotic network (AERONET) are considered as the ground truth for satellite validations. AERONET AEs are used to collocate the wavelength of the AERONET AODs to those of the satellite AODs when there is a discordancy in their wavelengths. However, numerous validation studies have proposed different strategies by applying the AERONET AODs and AEs, and spatiotemporal collocation criteria. This study examined the impact of the wavelength and spatial collocation radius variations by comparing AODs at 550 nm derived from the geostationary ocean color imager (GOCI) with those obtained from the AERONET for the year 2016. The estimated AERONET AODs at 550 nm varied from 5.18% to 11.73% depending on the selection of AOD and AE, and the spatial collocation radii from 0 to 40 km, respectively. The longer the collocation radius and the higher the AODs, the greater the variability observed in the validation results. Overall, the selection of the spatial collocation radius had a stronger impact on the variability in the validation results obtained compared to the selection of the wavelength. The variability was also found in seasonal analysis. Therefore, it is recommended to carefully select the data wavelength and spatial collocation radius, consider seasonal effects, and provide this information when validating satellite AODs using AERONET.

GOCI↗

Initial On-Orbit Spectral Calibration of the PACE Ocean Color Instrument

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Project Science Team has used Ocean Color Instrument (OCI) measurements of Fraunhofer lines in spectra of sunlight reflected by the solar diffuser and measurements of atmospheric absorption bands in cloudtop and ocean spectra to characterize the spectral calibration of OCI on orbit. Multiple lines have been analyzed for both the ultraviolet to visible (UVVIS, 340−607 nm) and visible to near-infrared (VISNIR, 597−897 nm) grating spectrographs. The spectrographs yield hyperspectral observations with 5 nm bandwidths and 0.625 nm sampling intervals. The on-orbit observations have been compared with the prelaunch spectral calibration of OCI performed by the Goddard Laser for Absolute Measurement of Radiance (GLAMR) during thermal vacuum testing to track any changes in the calibration since launch. The calibration analyzed the line positions and strengths for the Fraunhofer lines for each spectrograph by comparing the solar spectra measured by OCI with predicted solar spectra derived from the solar reference spectrum and the BRDF of the solar diffuser, convolved with the OCI relative spectral responses. The calibration also compared the line positions of the atmospheric absorption bands with the model transmissions used by the PACE Project. The line position comparisons show that the root mean square (RMS) spectral difference between the measured and predicted spectra is 0.15 nm, the average spectral shift is 0.062 nm, and the residual spectral dispersion over the wavelength range of the Fraunhofer lines is 0.17 nm. All three estimates of the spectral accuracy of OCI meet the instrument functional requirement of a spectral accuracy of 0.5 nm and are well within the 0.625 nm sampling interval of the data. The line strength comparisons between measured and predicted spectra are essentially the same. These results show that the spectral calibration of OCI on orbit has not drifted since the prelaunch calibration of OCI by GLAMR and that the on-orbit spectral calibration of OCI is stable over time. These results also provide a baseline for monitoring the future spectral performance of OCI on orbit.

Radiometric Calibration↗

Pre-Launch Analysis and Test of the Ocean Color Instrument Modulation Transfer Function

Launched in February 2024, the Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. The Ocean Color Instrument (OCI) is the primary instrument supporting PACE by collecting accurate radiometric data of the Earth by observing the top of atmosphere reflectance and is a combination hyperspectral (ultra-violet to near infrared) / multiband imager (shortwave infrared). An important aspect of the radiometry is the ability of OCI to resolve contrast from scene to scene to achieve data accuracy requirements. This paper reviews the analysis that was performed to verify the modulation transfer function requirement levied against the instrument and presents the supportive test data collected during pre-launch instrument testing to supplement the analysis. The requirements levied against OCI drove to a 1.2 km2 ground resolution leading to a Nyquist period of 2.4 km (0.417 cycles / km). The analysis is comprehensive with incorporation of as many contributors as practical to provide the clearest possible picture of the margin against requirements. The analysis provided input for additional design trade studies and insight into the aspects of the design that required the most attention during the implementation phase. We describe four separate MTF contributor networks based on the instrument design and mutual exclusivity of contributing factors. The various networks represent the hyperspectral and multiband detection systems separately as well as the along track and cross track imaging dimensions. Ground-test was performed against the MTF primary contributors and the results were used to validate the analysis as will be presented here.

OCI↗

Spectrally Dependent Radiometric Measurement Errors Due to Ccd Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a 322 887 nm hyperspectral imager with 1 km x 1 km nadir spatial resolution and 5 nm spectral resolution utilizing charge-coupled devices (CCDs) operating in Time Delay Integration (TDI) mode where each TDI column represents a different wavelength in 0.625 nm increments. After TDI, the charge is moved into serial output pixels and read out. The spatial resolution requires an 8.5 MHz readout rate. This only allows 59 ns for the CCD reset and video to be asserted and settled before sampling. The response exhibits serial pixel-to-pixel readout interference due to the lack of full settling. Each serial pixel value has a dependence on the value of the preceding pixel value. This leads to a spectrally dependent radiometric measurement error of up to 0.3 %. We explain the operation of the detection system, the behavior of the interference, and show the resulting measurement error based on data from both ground testing and on-orbit characterization.

Remote Sensing↗

Spectrally Dependent Radiometric Measurement Errors Due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a 322 887 nm hyperspectral imager with 1 km x 1 km nadir spatial resolution and 5 nm spectral resolution utilizing charge-coupled devices (CCDs) operating in Time Delay Integration (TDI) mode where each TDI column represents a different wavelength in 0.625 nm increments. After TDI, the charge is moved into serial output pixels and read out. The spatial resolution requires an 8.5 MHz readout rate. This only allows 59 ns for the CCD reset and video to be asserted and settled before sampling. The response exhibits serial pixel-to-pixel readout interference due to the lack of full settling. Each serial pixel value has a dependence on the value of the preceding pixel value. This leads to a spectrally dependent radiometric measurement error of up to 0.3 %. We explain the operation of the detection system, the behavior of the interference, and show the resulting measurement error based on data from both ground testing and on-orbit characterization.

Remote Sensing↗

Pre-Launch Analysis and Test of the Ocean Color Instrument Modulation Transfer Function

Launched in February 2024, the Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. The Ocean Color Instrument (OCI) is the primary instrument supporting PACE by collecting accurate radiometric data of the Earth by observing the top of atmosphere reflectance and is a combination hyperspectral (ultra-violet to near infrared) / multiband imager (shortwave infrared). An important aspect of the radiometry is the ability of OCI to resolve contrast from scene to scene to achieve data accuracy requirements. This paper reviews the analysis that was performed to verify the modulation transfer function requirement levied against the instrument and presents the supportive test data collected during pre-launch instrument testing to supplement the analysis. The requirements levied against OCI drove to a 1.2 km2 ground resolution leading to a Nyquist period of 2.4 km (0.417 cycles / km). The analysis is comprehensive with incorporation of as many contributors as practical to provide the clearest possible picture of the margin against requirements. The analysis provided input for additional design trade studies and insight into the aspects of the design that required the most attention during the implementation phase. We describe four separate MTF contributor networks based on the instrument design and mutual exclusivity of contributing factors. The various networks represent the hyperspectral and multiband detection systems separately as well as the along track and cross track imaging dimensions. Ground-test was performed against the MTF primary contributors and the results were used to validate the analysis as will be presented here.

OCI↗

Metal sensitized color changing material

The subject invention pertains to color changeable, film materials comprising a metal substrate layer; a conducting polymer or conducting polymer composite layer; and an electrolyte layer. The conducting polymer or conducting polymer composite layer of the film material is capable of exhibiting changes in one or more optical properties when the film material is in contact with a metal. The subject invention also pertains to methods of preparing conducting polymer films capable of exhibiting changes in optical properties.

Ram, Manoj Kumar↗

Double-real corrections to color singlet decay in a parton-shower inspired scheme

We introduce a local infrared subtraction method for next-to-next-to-leading order QCD calculations in color singlet decays, with counterterms based on scalar radiators and pure splitting functions. Overlapping singularities in the multipole radiation pattern are disentangled by partial fractioning, and the kinematics mapping corresponds to iterated next-to-leading order kinematics. We verify that the double-real remainder to $e^+e^-\to\;q\bar{q}$ is rendered finite in the single and double unresolved limits and investigate the numerical convergence of the Monte-Carlo integral. We compute the phase-space integrals of the scalar counterterms in the back-to-back configuration, both analytically and with the help of numerical techniques based on sector decomposition.

Campbell, John M. [Fermilab]↗

Effect of localization on photoluminescence and zero-field splitting of silicon color centers

The study of defect centers in silicon has been recently reinvigorated by their potential applications in optical quantum information processing. A number of silicon defect centers emit single photons in the telecommunication O-band, making them promising building blocks for quantum networks between computing nodes. The two-carbon G-center, self-interstitial W-center, and spin-1/2 T-center are the most intensively studied silicon defect centers, yet despite this, there is no consensus on the precise configurations of defect atoms in these centers, and their electronic structures remain ambiguous. Here, in this work, we employ ab initio density functional theory to characterize these defect centers, providing insight into the relaxed structures, band structures, and photoluminescence spectra, which are compared to experimental results. Motivation is provided for how these properties are intimately related to the localization of electronic states in the defect centers. In particular, we present the calculation of the zero-field splitting for the excited triplet state of the G-center defect as the structure is linearly interpolated from the A-configuration to the B-configuration, showing a sudden increase in the magnitude of the D zz component of the zero-field-splitting tensor. By performing projections onto the local orbital states of the defect, we analyze this transition in terms of the symmetry and bonding character of the G-center defect, which sheds light on its potential application as a spin-photon interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗