Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

LEO life tests on a 75 Ah bipolar nickel-hydrogen battery

The design, building, and testing of an actively cooled 10-cell 75-Ah bipolar nickel/hydrogen battery are discussed. During the last 1000 cycles, the battery has shown some evidence of elecrical performance degradation. In particular, EOC and EOD voltages have increased and decreased by several millivolts, respectively, and deep discharge capacities to a 1.0 V/cell average cutoff voltage have decreased.

Lenhart, S.↗

Polymer/Silicate Nanocomposites Used to Manufacture Gas Storage Tanks With Reduced Permeability

Over the past decade, there has been considerable research in the area of polymer-layered silicate nanocomposites. This research has shown that the dispersion of small amounts of an organically modified layered silicate improves the polymer strength, modulus, thermal stability, and barrier properties. There have been several reports on the dispersion of layered silicates in an epoxy matrix. Potential enhancements to the barrier properties of epoxy/silicate nanocomposites make this material attractive for low permeability tankage. Polymer matrix composites (PMCs) have several advantages for cryogenic storage tanks. They are lightweight, strong, and stiff; therefore, a smaller fraction of a vehicle's potential payload capacity is used for propellant storage. Unfortunately, the resins typically used to make PMC tanks have higher gas permeability than metals. This can lead to hydrogen loss through the body of the tank instead of just at welds and fittings. One approach to eliminate this problem is to build composite tanks with thin metal liners. However, although these tanks provide good permeability performance, they suffer from a substantial mismatch in the coefficient of thermal expansion, which can lead to failure of the bond between the liner and the body of the tank. Both problems could be addressed with polymersilicate nanocomposites, which exhibit reduced hydrogen permeability, making them potential candidates for linerless PMC tanks. Through collaboration with Northrop Grumman and Michigan State University, nanocomposite test tanks were manufactured for the NASA Glenn Research Center, and the helium permeability was measured. An organically modified silicate was prepared at Michigan State University and dispersed in an epoxy matrix (EPON 826/JeffamineD230). The epoxy/silicate nanocomposites contained either 0 or 5 wt% of the organically modified silicate. The tanks were made by filament winding carbon fibers with the nanocomposite resin. Helium permeability was measured by Northrop Grumman, showing that the leak rate/day of the nanocomposite matrix tank was approximately 80-percent less than that of the neat epoxy matrix tank.

Campbell, Sandi G.↗

TERRA/MOPITT Measurements of Tropospheric Carbon Monoxide Distributions in Support of INTEX

Interaction with the ongoing satellite measurements programs was an important goal of INTEX- A. The Terra/MOPITT instrument had been making global measurements of the tropospheric carbon monoxide (CO) distribution for 4 years, and was in a unique position to provide valuable support during the field campaign. Remote sensing of CO directly addressed the scientific questions motivating the IXTEX-A strategy and deployment, and measurement of this gas was rated as being mission critical. CO is an important trace gas in tropospheric chemistry due to its role in determining the atmospheric oxidizing capacity, as an ozone precursor, and as an indicator and tracer of both natural and anthropogenic pollution arising from incomplete combustion. The satellite perspective provided the more general temporal and spatial context to the aircraft and ground-based measurements during the subsequent scientific analysis. We proposed to build on the experience of supplying MOPITT data to previous field campaigns, such as TRACE-P. We provided expedited MOPITT data processing in near real-time, along with basic analysis of the measurements to indicate, where possible, the origin of the CO plumes that impacted the regions of flight operations and other in situ measurement activities. To ensure maximum exploitation of the satellite information, we will also had a scientist in the field to present and interpret the MOPITT data for the INTEX team, and to help ensure its utility in flight planning.

Edwards, D. P.↗

Data Center Waste Heat as an Emerging Urban Thermal Hazard: First Field Measurements of Neighborhood-Scale Air Temperature Impacts

Data centers are among the fastest-growing sources of concentrated anthropogenic heat in urban environments. Despite heat flux densities that exceed peak solar irradiance by a factor of 2–6, their thermal impacts on adjacent communities have never been directly measured or reported in the peer-reviewed literature. This short communication addresses that gap by presenting the first vehicle-based traverse measurements of air temperature in residential neighborhoods downwind of operational data centers. Five traverses at four facilities in the Phoenix, Arizona metropolitan area, ranging from a 36 MW single-building data center in Mesa to a 169 MW colocation campus in Chandler, reveal downwind air temperature warming as high as 2.2 °C, with average downwind air temperatures 0.7–0.9 °C warmer than corresponding upwind areas. Thermal signatures were detectable at distances up to 500 m from facility perimeters. The 36 MW Mesa facility rejects waste heat equivalent to the electricity consumption of approximately 40,000 households, while the 169 MW Chandler campus is equivalent to over 180,000 households, both concentrated into footprints smaller than a single residential subdivision. With U.S. data center capacity projected to more than double by 2030, these findings establish data center anthropogenic waste heat as a previously undocumented urban thermal hazard demanding attention from the data center and urban planning communities.

Phoenix↗

U.S. energy sector impacts of technology innovation, fuel price, and electric sector CO2 policy: Results from the EMF 32 model intercomparison study

We study the impact of fuel prices, technology innovation, and a CO2 emissions reduction policy on both the electric power and end-use sectors by comparing outputs from four U.S. energy-economic models through the year 2050. Achieving innovation goals decreases CO2 emissions in all models, regardless of natural gas price, due to increased energy efficiency and low-carbon generation becoming more cost competitive. For the models that include domestic natural gas markets, achieving innovation goals lowers wholesale electricity prices, but this effect diminishes as projected natural gas prices increase. Higher natural gas prices lead to higher wholesale electricity prices but fewer coal capacity retirements. A CO2 electric power sector emissions cap influences electric sector evolution under reference technology assumptions but has little to no incremental influence when added to innovation goals. Long-term, meeting innovation goals achieves a generation mix with similar CO2 emissions compared to the CO2 policy but with smaller increases to wholesale electricity prices. In the short-term, the relative effect on wholesale prices differs by model. Finally, higher natural gas prices, achieving innovation goals, and the combination of the two, increases the amount of renewable generation that is cost-effective to build and operate while slowing the growth of natural-gas fired generation, which is the predominant generation type in 2050 under reference conditions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Making Coal Relevant for Small Scale Applications: Modular Gasification for Syngas/Engine CHP Applications in Challenging Environments

This Front-End Engineering Design (FEED) study is funded by the US Department of Energy (DOE), and managed by the National Energy Technology Laboratory (NETL) through a Cooperative Agreement awarded to the University of Alaska Fairbanks (UAF) to perform a technical and cost study for the design and installation of a Hamilton-Maurer International (HMI) gasifier for generating a clean syngas for firing in reciprocating engines. An existing diesel engine generator (DEG) and a commercially available spark ignition engine are used to generate electricity with the low-Btu syngas. Other than the HMI gasifier, only commercially available technologies were assumed for this study. An important objective of this design study was to estimate capital and operating costs of small modular coal and coal/biomass fired generating units to provide wind regulation services. Although this study is based on retrofitting an existing coal fired power plant with the HMI gasifier, sufficient data was developed to characterize greenfield units. The original concept was to provide clean syngas and tars/oils from the gasification process to the existing Colt-Pielstick PC2.6B diesel engine generator (9.6 MWe) installed at the UAF Atkinson Power Plant. The intent was to convert the diesel engine to operate in a dual fuel mode, firing both syngas and tars/oils. As the project progressed, Fairbanks Morse Engine (FME), current licensee for the Colt-Pielstick engine line, was not able to develop a modification package for the engine to allow for syngas firing. Although this type of modification is available for firing natural gas, the capability does not extend to syngas. Western Energy Systems, distributor for Innio Jenbacher, was able to offer the Jenbacher Model JMS620 engine. After review of available options, the project team selected a design configuration using two Jenbacher engines rated at 1965 kWe each to fire the syngas, with the oils/tars directed to the Colt Pielstick diesel to be blended with ultra-low sulfur diesel oil (ULSD). The Jenbacher engines are expected to operate at continuous base load, with some load-following ability, while the existing diesel engine will operate in grid support service, with loads varying from a nominal 25% to 100%. An annual capacity factor for the diesel engine is projected to be between 50% and 60%. The overall gasifier and gas clean-up system is sized to produce enough syngas to adequately fuel three Jenbacher Engines for a nominal power output of 5.9 MWe, but this study assumes that only two Jenbacher engines will be installed due to space constraints in the Atkinson Power Plant, and because of expected air emission permit limitations. There is still potential that the excess syngas capacity equivalent to about 2 MWe could be used as supplemental fuel for the DEG. The exhaust from the Jenbacher engines is passed through heat recovery units to generate low pressure steam, thereby providing a significant portion of the steam required for operating the gasifier. The overall performance of the HMI gasifier/engine configuration is summarized as follows: 1) Overall electric efficiency, Jenbacher and diesel engines, based on gasifier fuel production (syngas and pyrolysis liquids) is 35.2% LHV, 2) Overall cogenerating efficiency (electricity plus steam), based on gasifier fuel production (syngas and pyrolysis liquids) is 54.8% LHV, 3) Overall electric efficiency, Jenbacher and diesel engines, based on coal input, is 29.6% LHV, and 4) Overall cogenerating efficiency, electricity plus steam, based on coal input is 46.0%. This project is estimated to have a Bare Erected Cost (BEC) of $\$$ 33.4 million and a Total Plant Cost (TPC) of $\$$ 45.7 million. Based on the original scope, sending both the clean syngas and the oils and tars to the existing diesel engine, the BEC and TPC values would have been $\$$ 23.3 million and $\$$ 32.1 million, respectively. A variable Cost of Electricity (COE) is calculated to reflect only those costs that will be incurred by incremental operation of the system for the HMI gasifier/Jenbacher engine combination. Operation of the diesel engine is determined separately. The variable COE values are: Case 1: 100% Usibelli Coal: (a) HMI gasifier/Jenbacher Engines -- 8.3 cents/kWh; (b) Diesel Engine -- 20.2 cents/kWh, and Case 2: 80% Usibelli Coal + 20% wood chips (proportion based on Btu input, LHV basis): (a) HMI Gasifier/Jenbacher -- 13.7 cents/kWh; (b) Diesel Engine -- 20.2 cents/kWh. The incremental cost of operating the gasifier/Jenbacher system increases with co-firing of wood chips due to the high cost of this material, over five times as costly as Usibelli coal delivered to the Atkinson Power building. The diesel cost is constant as the oils and tars are priced at the same value as the ULSD for the purposes of fueling the diesel engine. Section 8 of this report provides details of the O&M costs. The overall power system is configured to be modular and scalable to provide a wide range of generating capacity using the same components. This allows for reduction in cost, risk, schedule time to engineer and construct, and provides some degree of repeatability for air permitting.

01 COAL, LIGNITE, AND PEAT↗

An indium-based microporous metal–organic framework with unique three-way rod-shaped secondary building units for efficient methane and hydrogen storage

A novel microporous indium-based MOF material with unique 3-way rod-shaped secondary building units (SBUs), UTSA-22, was reported and exhibited high methane (CH 4 ) and hydrogen (H 2 ) storage. At 298 K and 65 bar, the total CH 4 volumetric uptake of UTSA-22 is 174 cm 3 (STP) cm -3 . Moreover, UTSA-22 shows a high CH 4 working capacity of 146 cm 3 (STP) cm -3 in a pressure range of 5–65 bar at 298 K. Additionally, UTSA-22 shows a high H 2 gravimetric storage capacity (1.2 wt%) at 298 K and 100 bar.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microgrid Controller Design, Implementation, and Deployment: A Journey from Conception to Implementation at the Philadelphia Navy Yard

The Philadelphia Navy Yard is a fast-evolving community microgrid, currently home to over 150 companies and four Navy activity centers occupying nearly 7 million ft2 of buildings in which approximately 12,000 people are employed. The Navy Yard (TNY) is a national center of excellence for energy research, education, and commercialization, focused specifically on community microgrid design and development. TNY microgrid is equipped with the most cost-effective and sustainable means for meeting electric capacity and energy needs through renewable resources, energy efficiency, and distribution grid infrastructure. This article briefly describes how the community microgrid was conceived and planned to produce a great success story of microgrid implementation and the details of the design, development, and implementation of the TNY microgrid controller.

Uluski, R.↗

Solar Deployment System (SolarDS) Model: Documentation and Sample Results

The Solar Deployment System (SolarDS) model is a bottom-up, market penetration model that simulates the potential adoption of photovoltaics (PV) on residential and commercial rooftops in the continental United States through 2030. NREL developed SolarDS to examine the market competitiveness of PV based on regional solar resources, capital costs, electricity prices, utility rate structures, and federal and local incentives. The model uses the projected financial performance of PV systems to simulate PV adoption for building types and regions then aggregates adoption to state and national levels. The main components of SolarDS include a PV performance simulator, a PV annual revenue calculator, a PV financial performance calculator, a PV market share calculator, and a regional aggregator. The model simulates a variety of installed PV capacity for a range of user-specified input parameters. PV market penetration levels from 15 to 193 GW by 2030 were simulated in preliminary model runs. SolarDS results are primarily driven by three model assumptions: (1) future PV cost reductions, (2) the maximum PV market share assumed for systems with given financial performance, and (3) PV financing parameters and policy-driven assumptions, such as the possible future cost of carbon emissions.

14 SOLAR ENERGY↗

The impact of carbonation on bulk and ITZ porosity in microconcrete materials with fly ash replacement

Scanning electron microscopy was used to evaluate the porosity patterns found in microconcrete materials to better understand the gaseous diffusion pathways and reaction of CO{sub 2} within the bulk cement paste and interfacial transition zone (ITZ) of microconcrete materials containing different fly ash replacement types. Image segmentation was applied to evaluate the porosity as a function of distance from an exposed surface in the bulk cement paste and from aggregate boundaries in the ITZ in both carbonated and non-carbonated microconcrete materials. The ITZ region remained more porous compared to the bulk cement paste for all microconcrete types after carbonation despite a change in the porosity profile across the ITZ region. Results indicate that both the carbonation reaction capacity and porosity before carbonation impact the decrease in porosity observed as a result of carbonation in the ITZ and bulk cement paste regions.

36 MATERIALS SCIENCE↗

Secondary Pollutants from Ozone Reaction with Ventilation Filters and Degradation of Filter Media Additives

Prior research suggests that chemical processes taking place on the surface of particle filters employed in buildings may lead to the formation of harmful secondary byproducts. We investigated ozone reactions with fiberglass, polyester, cotton/polyester and polyolefin filter media, as well as hydrolysis of filter media additives. Studies were carried out on unused media, and on filters that were installed for 3 months in buildings at two different locations in the San Francisco Bay Area. Specimens from each filter media were exposed to {approx}150 ppbv ozone in a flow tube under a constant flow of dry or humidified air (50percent RH). Ozone breakthrough was recorded for each sample over periods of {approx}1000 min; the ozone uptake rate was calculated for an initial transient period and for steady-state conditions. While ozone uptake was observed in all cases, we did not observe significant differences in the uptake rate and capacity for the various types of filter media tested. Most experiments were performed at an airflow rate of 1.3 L/min (face velocity = 0.013 m/s), and a few tests were also run at higher rates (8 to 10 L/min). Formaldehyde and acetaldehyde, two oxidation byproducts, were quantified downstream of each sample. Those aldehydes (m/z 31 and 45) and other volatile byproducts (m/z 57, 59, 61 and 101) were also detected in real-time using Proton-Transfer Reaction - Mass Spectrometry (PTR-MS). Low-ppbv byproduct emissions were consistently higher under humidified air than under dry conditions, and were higher when the filters were loaded with particles, as compared with unused filters. No significant differences were observed when ozone reacted over various types of filter media. Fiberglass filters heavily coated with impaction oil (tackifier) showed higher formaldehyde emissions than other samples. Those emissions were particularly high in the case of used filters, and were observed even in the absence of ozone, suggesting that hydrolysis of additives, rather than ozonolysis, is the main formaldehyde source in those filters. Emission rates of formaldehyde and acetaldehyde were not found to be large enough to substantially increase indoor concentrations in typical building scenarios. Nevertheless, ozone reactions on HVAC filters cannot be ignored as a source of low levels of indoor irritants.

54 ENVIRONMENTAL SCIENCES↗

Data transfer for STAR grid jobs

The Solenoidal Tracker at RHIC (STAR) is a multipurpose experiment at the Relativistic Heavy Ion Collider (RHIC) with the primary goal to study the formation and properties of the quark-gluon plasma. STAR is an international collaboration of member institutions and laboratories from around the world. Yearly data-taking period produces PBytes of raw data collected by the experiment. STAR primarily uses its dedicated facility at BNL to process this data, but has routinely leveraged distributed systems, both high throughput (HTC) and high performance (HPC) computing clusters, to significantly augment the processing capacity available to the experiment. The ability to automate the efficient transfer of large data sets on reliable, scalable, and secure infrastructure is critical for any large-scale distributed processing campaign. For more than a decade, STAR computing has relied upon GridFTP with its x509-based authentication to build such data transfer systems and integrate them into its larger production workflow. The end of support by the community for both GridFTP and the x509 standard requires STAR to investigate other approaches to meet its distributed processing needs. In this study we investigate two multi-purpose data distribution systems, Globus.org and XRootD, as alternatives to GridFTP. We compare both their performance and the ease by which each service is integrated into the type of secure and automated data transfer systems STAR has previously built using GridFTP. The presented approach and study may be applicable to other distributed data processing use cases beyond STAR.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The status of LILW disposal facility construction in Korea

In this paper, we discuss the experiences during the construction of the first LILW disposal facility in South Korea. In December 2005, the South Korean Government designated Gyeongju-city as a host city of Low- and Intermediate-Level Radioactive Waste(LILW) disposal site through local referendums held in regions whose local governments had applied to host disposal facility in accordance with the site selection procedures. The LILW disposal facility is being constructed in Bongilri, Yangbuk-myeon, Gyeongju. The official name of the disposal facility is called 'Wolsong Low and Intermediate Level Radioactive Waste Disposal Center (LILW Disposal Center)'. It can dispose of 800,000 drums of radioactive wastes in a site of 2,100,000 square meters. At the first stage, LILW repository of underground silo type with disposal capacity of 100,000 drums is under construction expected to be completed by June of 2014. The Wolsong Low and Intermediate Level Radioactive Waste Disposal Center consists of surface facilities and underground facilities. The surface facilities include a reception and inspection facility, an interim storage facility, a radioactive waste treatment building, and supporting facilities such as main control center, equipment and maintenance shop. The underground facilities consist of a construction tunnel for transport of construction equipment and materials, an operation tunnel for transport of radioactive waste, an entrance shaft for workers, and six silos for final disposal of radioactive waste. As of Dec. 2012, the overall project progress rate is 93.8%. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comprehensive Economic Coal Transition in South Asia

Many countries are considering accelerating their coal transition. A coal transition refers to an energy sector’s shift from a reliance on coal toward an energy mix largely based on cleaner fuels and renewable energy sources. Such a transition is not just related to greenhouse gas emissions, but also encompasses a range of benefits, recognizing that global energy costs and options are changing. Since 2015, proposed new coal power capacity has dropped by three-quarters globally, leaving only a few countries that develop coal-fired power plants at scale (Littlecott et al., 2021). Historic steps were taken at the United Nations Climate Change 26th Conference of Parties (COP26) in Glasgow, as countries pledged to stop new coal builds, end international coal financing, phase down and phase out unabated coal use, and transition to clean energy. In South Asia, there have been several indicators suggesting that countries may be open to moving toward a coal transition. For example, the number of coal power plants under development across South Asia has decreased by 87% since 2015 (Littlecott et al., 2021). However, the challenges of assuring a just transition are substantial. Because coal plays a critical role in the energy and economic systems in South Asia, especially India, moving away from coal means realizing a broader country-wide economic and social transition. A comprehensive, integrated transition strategy for each state is thus needed urgently. This report briefly reviews the current trends and policies on coal in South Asian countries, develops a framework for a comprehensive economic coal transition, and assesses the opportunities and challenges of the transition in key countries. Several important findings emerge from the analysis. First, a coal transition can support overall economic growth and stability. Financial advantages to a well-planned coal transition include mitigating the risk of stranded assets and taking advantage of low-cost renewables. As a global coal transition proceeds, funds are being diverted from new unabated coal power plants, and utilization rates are declining. The likelihood that coal assets will become stranded is increasing, and the potential for future losses therefore increases as well. Second, coal imports in South Asia are rising. Of the coal consumed in Bangladesh, India, Nepal, and Sri Lanka, 32% is imported; this number increases to 94% when excluding India (International Energy Agency [IEA], 2021d). This illustrates a serious energy security risk. One example is the recent increase in coal prices in South Asia, to be discussed in Section 2.2.1. A diverse energy portfolio that incorporates local renewable energy can provide resilience in the face of changing commodity prices and availability. Third, the social benefits of a coal transition include positive health impacts and broader economic improvements in job creation, although assuring a just transition may be a challenge. Phasing out or phasing down coal can significantly reduce air pollutant emissions and therefore minimize associated premature mortality and improve life expectancy. Additional societal benefits of a coal transition include the high economy-wide potential for job creation, although it creates challenges in terms of reintegration and resettlement for coal miners and their communities.

01 COAL, LIGNITE, AND PEAT↗

Greenhouse Gas Life Cycle Emissions Assessment Model (GLEAM) Model Documentation

The Greenhouse gas Life cycle Emissions Assessment Model (GLEAM) estimates life cycle greenhouse gas emissions from future scenarios of electricity generation considering a wide range of generation technologies. Building on the National Laboratory of the Rockies longstanding effort to quantify life cycle emissions by electricity generation technology under the LCA Harmonization Project, GLEAM streamlines the process of estimating cumulative greenhouse gas emissions on a life cycle basis. Given a set of inputs regarding annual installed and decommissioned generation capacity, as well as generation, GLEAM estimates the carbon dioxide equivalent emissions by year. The model also offers optional modules to decompose carbon dioxide equivalent emissions into constituent greenhouse gases (e.g., carbon dioxide, methane, and nitrous oxide) as well as estimate hydrogen leakage from relevant technologies. The results from GLEAM can be used to inform future electricity planning scenarios as well as investment or regulatory decisions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Demand Management: Concepts and Procedures

This report provides a comprehensive description of the Integrated Demand Management concept. Motivation: NASA’s Integrated Demand Management (IDM) research explores the idea that, under certain conditions, time-based flow management (TBFM) arrival operations can benefit from the coordinated use of a strategic traffic management initiative (TMI) to “precondition” the inbound demand. The research was motivated by the observation that TBFM was usually turned off during convective weather, even in facilities where it was routinely used. Our hypothesis was that strategic adjustments to the inbound traffic so that it provided a better match to the off-nominal changes in capacity observed during these conditions could enable TBFM scheduling to continue to provide effective support for arrival traffic management. Concept: IDM proposes that a TMI (e.g., a Collaborative Trajectory Options Program, or CTOP) be used to adjust the rate and/or geographic distribution across flows of the traffic inbound to a high-demand, TBFM-managed airport before that traffic reaches the TBFM planning horizon. After this strategic preconditioning, TBFM can then tactically fine-tune the demand to deliver a well-managed, orderly feed to the destination airport. Coordinated use of these two flow management capabilities is intended to improve system performance in terms of: • Equity of ground delay assignment, avoiding excessive ground delay for TBFM-scheduled departures, without penalizing longer flights; • Throughput, by distributing traffic to maximize use of available capacity; • Predictability for operators, providing advance notice about the impact on individual flights; • Increased flexibility, supporting operator mitigation strategies such as slot swapping or trajectory options; • Efficiency of flight operations, using ground delay more effectively and reducing airborne delay. The operational description in this document highlights how the IDM concept builds upon already existing tools and procedures, and also indicates where tool enhancements could facilitate conduct of IDM operations. However, enhanced tools are not a requirement for concept introduction. In fact, initial deployment that focused on training procedures and rationale for coordinated use of TFMS and TBFM, without changes to existing tools, might be a simpler way to introduce and to familiarize traffic managers with the idea of preconditioning. The concept and procedures described in this document can hopefully provide useful guidance for introduction of IDM into field operations..

IDM↗