Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONFINEMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Note: Light output enhanced fast response and low afterglow {sup 6}Li glass scintillator as potential down-scattered neutron diagnostics for inertial confinement fusion

The characteristics of an APLF80+3Ce scintillator are presented. Its sufficiently fast decay profile, low afterglow, and an improved light output compared to the recently developed APLF80+3Pr, were experimentally demonstrated. This scintillator material holds promise for applications in neutron imaging diagnostics at the energy regions of 0.27 MeV of DD fusion down-scattered neutron peak at the world's largest inertial confinement fusion facilities such as the National Ignition Facility and the Laser Megajoule.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosing inertial confinement fusion gamma ray physics (invited)

The gamma reaction history (GRH) diagnostic is a multichannel, time-resolved, energy-thresholded {gamma}-ray spectrometer that provides a high-bandwidth, direct-measurement of fusion reaction history in inertial confinement fusion implosion experiments. 16.75 MeV deuterium+tritium (DT) fusion {gamma}-rays, with a branching ratio of the order of 10{sup -5}{gamma}/(14 MeV n), are detected to determine fundamental burn parameters, such as nuclear bang time and burn width, critical to achieving ignition at the National Ignition Facility. During the tritium/hydrogen/deuterium ignition tuning campaign, an additional {gamma}-ray line at 19.8 MeV, produced by hydrogen+tritium fusion with a branching ratio of unity, will increase the available {gamma}-ray signal and may allow measurement of reacting fuel composition or ion temperature. Ablator areal density measurements with the GRH are also made possible by detection of 4.43 MeV {gamma}-rays produced by inelastic scatter of DT fusion neutrons on {sup 12}C nuclei in the ablating plastic capsule material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Longitudinal Confinement of an Intense Beam Using Induction Focusing

Induction focusing is successfully used to confine a space-charge dominated beam for over 11.52 km, or more than 1000 turns in a 3.66 m-diameter ring with the periodic application of longitudinal fields to overcome the defocusing space-charge forces.

43 PARTICLE ACCELERATORS↗

Quantum confinement effects on charge-transfer between PbS quantum dots and 4-mercaptopyridine

We obtain the surface enhanced Raman spectra of 4-mercaptopyridine on lead sulfide (PbS) quantum dots as a function of nanoparticle size and excitation wavelength. The nanoparticle radii are selected to be less than the exciton Bohr radius of PbS, enabling the observation of quantum confinement effects on the spectrum. We utilize the variation of nontotally symmetric modes of both b{sub 1} and b{sub 2} symmetry as compared to the totally symmetric a{sub 1} modes to measure the degree of charge-transfer between the molecule and quantum dot. We find both size dependent and wavelength dependent resonances in the range of these measurements, and attribute them to charge-transfer resonances which are responsible for the Raman enhancement.

36 MATERIALS SCIENCE↗

Thermometry based on phonon confinement effect in nanoparticles

Raman spectra of TiO{sub 2} nanoparticles (NPs) have a very strong finite-size dependency due to the phonon confinement effect. This provides a convenient way to characterize NPs size by simply using Raman spectroscopy. Together with fast grain growth kinetics and high stability under high temperature and pressure, these NPs have the potential to forensically retain the complete thermal history (temperature and time) of an event that they went through. Here, we demonstrate that both temperature and time can be determined simultaneously by using these thermosensors in the range of 400-700 deg. C and 5-60 s, assuming that the temperature is constant (a step-function approximation to a thermal spike) during a thermal event.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Panel discussion: What don't we know about confinement?

The participants in this discussion session of the QCHS 9 meeting were each asked the following question: ''What would be the most useful piece of information that you could obtain, by whatever means, that would advance your own program, and/or our general understanding of confinement?'' This proceedings contains a brief summary of each panel member's contribution to the discussion, provided by the panel members themselves.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Confinement and deconfinement for any gauge group from dyons viewpoint

Basing on a semiclassical picture of dyons, we present a nonperturbative model of a pure Yang-Mills theory at any temperatures, for an arbitrary simple gauge group. We argue that at low temperatures dyons drive the Yang-Mills system for all groups to a phase where the 'eigenphases' of the Polyakov line are, as a vector, proportional to the Weyl vector being the half sum of positive roots. For most gauge groups it means confinement, in particular for 'quarks' in any N-ality nonzero representation of the SU(N) gauge group. At a critical temperature there is a 1st order phase transition for all groups (except SU(2) where the transition is 2nd order), characterized by a jump of Polyakov lines, irrespectively of whether the gauge group has a nontrivial center, or not.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A relativistic quark model with infrared confinement and the tetraquark state

We explore the consequences of treating the X(3872) meson as a tetraquark bound state. As dynamical framework we employ a relativistic constituent quark model which includes infrared confinement in an effective way. We calculate the decay widths of the observed channels X{yields}J/{psi}+2{pi}(3{pi}) and X{yields}D-bar{sup 0}+D{sup 0}+{pi}{sup 0} via the intermediate off-shell states X{yields}J/{psi}+{rho}({omega}) and X{yields}D-bar+D*. For reasonable values of the size parameter {Lambda}{sub X} of the X(3872) we find consistency with the available experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charge transfer, lattice distortion, and quantum confinement effects in Pd, Cu, and Pd-Cu nanoparticles; size and alloying induced modifications in binding energy

In this letter, effect of size and alloying on the core and valence band shifts of Pd, Cu, and Pd-Cu alloy nanoparticles has been studied. It has been shown that the sign and magnitude of the binding energy shifts is determined by the contributions of different effects; with quantum confinement and lattice distortion effects overlapping for size induced shifts in case of core levels and lattice distortion and charge transfer effects overlapping for alloying induced shifts at smaller sizes. These results are important for understanding gas molecule-solid surface interaction in metal and alloy nanoparticles in terms of valance band positions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Kinetic simulations of stimulated Raman backscattering and related processes for the shock-ignition approach to inertial confinement fusion

A detailed description of stimulated Raman backscattering and related processes for the purpose of inertial confinement fusion requires multi-dimensional kinetic simulations of a full speckle in a high-temperature, large-scale, inhomogeneous plasma. In particular for the shock-ignition scheme operating at high laser intensities, kinetic aspects are predominant. High- (I{lambda}{sub o}{sup 2}{approx}5x10{sup 15}W{mu}m{sup 2}/cm{sup 2}) as well as low-intensity (I{lambda}{sub o}{sup 2}{approx}10{sup 15}W{mu}m{sup 2}/cm{sup 2}) cases show the predominance of collisionless, collective processes for the interaction. While the two-plasmon decay instability and the cavitation scenario are hardly affected by intensity variation, inflationary Raman backscattering proves to be very sensitive. Brillouin backscattering evolves on longer time scales and dominates the reflectivities, although it is sensitive to the intensity. Filamentation and self-focusing do occur for all cases but on time scales too long to affect Raman backscattering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of surface currents in plasma confinement

During plasma instabilities, ''surface currents'' can flow at the interface between the plasma and the surrounding vacuum, and in most cases, they are a harmless symptom of the instability that is causing them. Large instabilities can lead to ''disruptions,'' an abrupt termination of the plasma with the potential to damage the machine in which it is contained. For disruptions, the correct calculation of surface currents is thought to be essential for modelling disruptions properly. Recently, however, there has been debate and disagreement about the correct way to calculate surface currents. The purpose of this paper is to clarify as simply as possible the role of surface currents for plasma confinement and to show that a commonly used representation for surface currents {sigma}-vector with {sigma}-vector={nabla}I and n-vector, I a scalar function, and n-vector the unit normal to the plasma surface, is only appropriate for the calculation of surface currents that are in magnetohydrodynamic equilibrium. Fortunately, this is the situation thought to be of most relevance for disruption calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time evolution of filamentation and self-generated fields in the coronae of directly driven inertial-confinement fusion capsules

Time-gated radiography with monoenergetic 15-MeV protons, 3-MeV protons, and 4-MeV alpha particles has revealed a rich and complex evolution of electromagnetic field structures in and around imploding, directly driven inertial-confinement fusion (ICF) targets at the OMEGA laser facility. Plastic-shell capsules and solid plastic spheres were imaged during and after irradiation with ICF-relevant laser drive (up to 6 x 10{sup 14} W/cm{sup 2}). Radial filaments appeared while the laser was on; they filled, and were frozen into, the out-flowing corona, persisting until well after the end of the laser drive. Data from specially designed experiments indicate that the filaments were not generated by two-plasmon-decay instabilities or by Rayleigh-Taylor instabilities associated with shell acceleration. Before the onset of visible filamentation, quasi-spherical field structures appeared outside the capsule in the images in a form that suggests outgoing shells of net positive charge. We conjecture that these discrete shells are related to multiple peaks seen previously in the spectra of protons ablated from the targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sheared-flow induced confinement transition in a linear magnetized plasma

A magnetized plasma cylinder (12 cm in diameter) is induced by an annular shape obstacle at the Large Plasma Device [W. Gekelman, H. Pfister, Z. Lucky, J. Bamber, D. Leneman, and J. Maggs, Rev. Sci. Instrum. 62, 2875 (1991)]. Sheared azimuthal flow is driven at the edge of the plasma cylinder through edge biasing. Strong fluctuations of density and potential ({delta}n/n{approx}e{delta}{phi}/kT{sub e}{approx}0.5) are observed at the plasma edge, accompanied by a large density gradient (L{sub n}={nabla}lnn{sup -1}{approx}2cm) and shearing rate ({gamma}{approx}300kHz). Edge turbulence and cross-field transport are modified by changing the bias voltage (V{sub bias}) on the obstacle and the axial magnetic field (B{sub z}) strength. In cases with low V{sub bias} and large B{sub z}, improved plasma confinement is observed, along with steeper edge density gradients. The radially sheared flow induced by ExB drift dramatically changes the cross-phase between density and potential fluctuations, which causes the wave-induced particle flux to reverse its direction across the shear layer. In cases with higher bias voltage or smaller B{sub z}, large radial transport and rapid depletion of the central plasma density are observed. Two-dimensional cross-correlation measurement shows that a mode with azimuthal mode number m=1 and large radial correlation length dominates the outward transport in these cases. Linear analysis based on a two-fluid Braginskii model suggests that the fluctuations are driven by both density gradient (drift wave like) and flow shear (Kelvin-Helmholtz like) at the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collection of solid and gaseous samples to diagnose inertial confinement fusion implosions

Collection of representative samples of debris following inertial confinement fusion implosions in order to diagnose implosion conditions and efficacy is a challenging endeavor because of the unique conditions within the target chamber such as unconverted laser light, intense pulse of x-rays, physical chunks of debris, and other ablative effects. We present collection of gas samples following an implosion for the first time. High collection fractions for noble gases were achieved. We also present collection of solid debris samples on flat plate collectors. Geometrical collection efficiencies for Au hohlraum material were achieved and collection of capsule debris (Be and Cu) was also observed. Asymmetric debris distributions were observed for Au and Be samples. Collection of Be capsule debris was higher for solid collectors viewing the capsule through the laser entrance hole in the hohlraum than for solid collectors viewing the capsule around the waist of the hohlraum. Collection of Au hohlraum material showed the opposite pattern: more Au debris was collected around the waist than through the laser entrance hole. The solid debris collectors were not optimized for minimal Cu backgrounds, which limited the conclusions about the symmetry of the Cu debris. The quality of the data limited conclusions on chemical fractionation effects within the burning, expanding, and then cooling plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the large neutron imaging system for inertial confinement fusion experiments

Inertial confinement fusion (ICF) requires a high resolution ({approx}10 {mu}m) neutron imaging system to observe deuterium and tritium (DT) core implosion asymmetries. A new large (150 mm entrance diameter: scaled for Laser MegaJoule [P. A. Holstein, F. Chaland, C. Charpin, J. M. Dufour, H. Dumont, J. Giorla, L. Hallo, S. Laffite, G. Malinie, Y. Saillard, G. Schurtz, M. Vandenboomgaerde, and F. Wagon, Laser and Particle Beams 17, 403 (1999)]) neutron imaging detector has been developed for such ICF experiments. The detector has been fully characterized using a linear accelerator and a {sup 60}Co {gamma}-ray source. A penumbral aperture was used to observe DT-gas-filled target implosions performed on the OMEGA laser facility. [T. R. Boehly, D. L. Brown, R. S. Craxton, R. L. Keck, J. P. Knauer, J. H. Kelly, T. J. Kessler, S. A. Kumpan, S. J. Loucks, S. A. Letzring, F. J. Marshall, R. L. McCrory, S. F. B. Morse, W. Seka, J. M. Soures, and C. P. Verdon, Opt. Commun. 133, 495 (1997)] Neutron core images of 14 MeV with a resolution of 15 {mu}m were obtained and are compared to x-ray images of comparable resolution.

43 PARTICLE ACCELERATORS↗

D-T gamma-to-neutron branching ratio determined from inertial confinement fusion plasmas

A new deuterium-tritium (D-T) fusion gamma-to-neutron branching ratio [{sup 3}H(d,{gamma}){sup 5}He/{sup 3}H(d,n){sup 4}He] value of (4.2 {+-} 2.0) Multiplication-Sign 10{sup -5} was recently reported by this group [Y. Kim et al. Phys. Rev. C (submitted)]. This measurement, conducted at the OMEGA laser facility located at the University of Rochester, was made for the first time using inertial confinement fusion (ICF) plasmas. Neutron-induced backgrounds are significantly reduced in these experiments as compared to traditional beam-target accelerator-based experiments due to the short pulse nature of ICF implosions and the use of gas Cherenkov {gamma}-ray detectors with fast temporal responses and inherent energy thresholds. It is expected that this ICF-based measurement will help resolve the large and long-standing inconsistencies in previously reported accelerator-based values, which vary by a factor of approximately 30. The reported value at ICF conditions was determined by averaging the results of two methods: (1) a direct measurement of ICF D-T {gamma}-ray and neutron emissions using absolutely calibrated detectors and (2) a separate cross-calibration against the better known D-{sup 3}He gamma-to-proton branching ratio [{sup 3}He(d, {gamma}){sup 5}Li/{sup 3}He(d,p){sup 4}He]. Here we include a detailed explanation of these results, and introduce as a corroborative method an in-situ{gamma}-ray detector calibration using neutron-induced {gamma}-rays. Also, by extending the established techniques to two additional series of implosions with significantly different ion temperatures, we test the branching ratio dependence on ion temperature. The data show a D-T branching ratio is nearly constant over the temperature range 2-9 keV. These studies motivate further investigation into the {sup 5}He and {sup 5}Li systems resulting from D-T and D-{sup 3}He fusion, respectively, and result in improved ICF {gamma}-ray reaction history diagnosis at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in compact proton spectrometers for inertial-confinement fusion and plasma nuclear science

Compact wedge-range-filter proton spectrometers cover proton energies {approx}3-20 MeV. They have been used at the OMEGA laser facility for more than a decade for measuring spectra of primary D{sup 3}He protons in D{sup 3}He implosions, secondary D{sup 3}He protons in DD implosions, and ablator protons in DT implosions; they are now being used also at the National Ignition Facility. The spectra are used to determine proton yields, shell areal density at shock-bang time and compression-bang time, fuel areal density, and implosion symmetry. There have been changes in fabrication and in analysis algorithms, resulting in a wider energy range, better accuracy and precision, and better robustness for survivability with indirect-drive inertial-confinement-fusion experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗