Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Linearity Analysis and Efficiency Testing of The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) Science Cameras for Flight

To unveil the complexity of the solar atmosphere, measurement of the magnetic field in the upper chromosphere and transition region is fundamentally important, as this is where the forces transition from plasma to magnetic field dominated. Measurements of the field are also needed to elucidate the energy transport from the lower atmospheric regions to the corona beyond. Such an advance in heliospheric knowledge became possible with the first flight of the international solar sounding rocket mission, CLASP. For the first time, linear polarization was measured in Hydrogen Lyman-Alpha at 121.60 nm in September 2015. For linear polarization measurements in this emission line, high sensitivity is required due to the relatively weak polarization signal compared to the intensity. To achieve this high sensitivity, a low-noise sensor is required with good knowledge of its characterization, including linearity. This work presents further refinement of the linearity characterization of the cameras flown in 2015. We compared the current from a photodiode in the light path to the digital response of the detectors. Pre-flight CCD linearity measurements were taken for all three flight cameras and calculations of the linear fits and residuals were performed. However, the previous calculations included a smearing pattern and a digital saturation region on the detectors which were not properly taken into account. The calculations have been adjusted and were repeated for manually chosen sub-regions on the detectors that were found not to be affected. We present a brief overview of the instrument, the calibration data and procedures, and a comparison of the old and new linearity results. The CLASP cameras will be reused for the successor mission, CLASP2, which will measure the Magnesium II h & k emission lines between 279.45 nm and 280.35 nm. The new approach will help to better prepare for and to improve the camera characterization for CLASP2.

linearit↗

Linearity Analysis and Efficiency Testing of The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) Science Cameras for Flight

To unveil the complexity of the solar atmosphere, measurement of the magnetic field in the upper chromosphere and transition region is fundamentally important, as this is where the forces transition from plasma to magnetic field dominated. Measurements of the field are also needed to elucidate the energy transport from the lower atmospheric regions to the corona beyond. Such an advance in heliospheric knowledge became possible with the first flight of the international solar sounding rocket mission, CLASP. For the first time, linear polarization was measured in Hydrogen Lyman-Alpha at 121.60 nm in September 2015. For linear polarization measurements in this emission line, high sensitivity is required due to the relatively weak polarization signal compared to the intensity. To achieve this high sensitivity, a low-noise sensor is required with good knowledge of its characterization, including linearity. This work presents further refinement of the linearity characterization of the cameras flown in 2015. We compared the current from a photodiode in the light path to the digital response of the detectors. Pre-flight CCD linearity measurements were taken for all three flight cameras and calculations of the linear fits and residuals were performed. However, the previous calculations included a smearing pattern and a digital saturation region on the detectors which were not properly taken into account. The calculations have been adjusted and were repeated for manually chosen sub-regions on the detectors that were found not to be affected. We present a brief overview of the instrument, the calibration data and procedures, and a comparison of the old and new linearity results. The CLASP cameras will be reused for the successor mission, CLASP2, which will measure the Magnesium II h & k emission lines between 279.45 nm and 280.35 nm. The new approach will help to better prepare for and to improve the camera characterization for CLASP2.

detector↗

Kepler Instrument Performance: An In-Flight Update

The Kepler Mission is designed to detect the 80 parts per million (ppm) signal from an Earth-Sun equivalent transit. Such precision requires superb instrument stability on time scales up to 2 days and systematic error removal to better than 20 ppm. The sole scientic instrument is the Photometer, a 0.95 m aperture Schmidt telescope that feeds the 94.6 million pixel CCD detector array, which contains both Science and Fine Guidance Sensor (FGS) CCDs. Since Kepler's launch in March 2009, we have been using the commissioning and science operations data to characterize the instrument and monitor its performance. We find that the in-flight detector properties of the focal plane, including bias levels, read noise, gain, linearity, saturation, FGS to Science crosstalk,and video crosstalk between Science CCDs, are essentially unchanged from their pre-launch values. Kepler'sunprecedented sensitivity and stability in space have allowed us to measure both short- and long- term effects from cosmic rays, see interactions of previously known image artifacts with starlight, and uncover several unexpected systematics that affect photometric precision. Based on these results, we expect to attain Kepler's planned photometric precision over 90% of the field of view.

CCD↗

Realization of a Faster, Cheaper, Better Star Tracker for the New Millennium

The first Danish satellite, إrsted, will be launched in August of 1997. The scientific objective of إrsted is to perform a precision mapping of the Earth's magnetic field. Attitude data for the payload and the satellite are provided by the Advanced Stellar Compass (ASC) star tracker. The ASC consists of a CCD star camera and a capable microprocessor which operates by comparing the star image frames taken by the camera to its internal star catalogs.

star↗

Spatial Acquisition in the Presence of Satellite Vibrations for Free Space Optical Communication Link

Laser communication systems offer distinct advantages over radio frequency based systems for near earth and particularly for deep space communicaiton links. Some of the advantages are smaller size, lower power requirements and higher data rates. However, laser beam widths are very narrow and require more precise pointing, acquisition and tracking (PAT) compared to RF communication sytems. In addition to imprecise knowledge of relative position and complex relative motion between the spacecrafts, the problem of pointing and acquisition is complicated by vibrations present in the spacecraft. This paper analyzes the impact of satellite vibration on acquisition time and acquisition probability for a charge coupled device (CCD) based acquisition scheme.

laser↗

Scintillator Efficiency Study with MeV X-Rays

We have investigated scintillator efficiency for MeV radiographic imaging. This paper discusses the modeled detection efficiency and measured brightness of a number of scintillator materials. An optical imaging camera records images of scintillator emission excited by a pulsed x-ray machine. The efficiency of various thicknesses of monolithic LYSO:Ce (cerium-doped lutetium yttrium orthosilicate) are being studied to understand brightness and resolution trade-offs compared with a range of micro-columnar CsI:Tl (thallium-doped cesium iodide) scintillator screens. The micro-columnar scintillator structure apparently provides an optical gain mechanism that results in brighter signals from thinner samples. The trade-offs for brightness versus resolution in monolithic scintillators is straightforward. For higher-energy x-rays, thicker materials generally produce brighter signal due to x-ray absorption and the optical emission properties of the material. However, as scintillator thickness is increased, detector blur begins to dominate imaging system resolution due to the volume image generated in the scintillator thickness and the depth of field of the imaging system. We employ a telecentric optical relay lens to image the scintillator onto a recording CCD camera. The telecentric lens helps provide sharp focus through thicker-volume emitting scintillators. Stray light from scintillator emission can also affect the image scene contrast. We have applied an optical light scatter model to the imaging system to minimize scatter sources and maximize scene contrasts.

scintillator, radiography, CCD camera, hard x-ray,↗

Functional Requirements for the WEIS Toolset to Enable Controls Co-Design of Floating Offshore Wind Turbines: Preprint

The goal of the new Wind Energy with Integrated Servo-control (WEIS) toolset under development is to provide the offshore wind industry and research communities with an open-source, user-friendly, and flexible tool to enable true Controls Co-Design (CCD) of the physical design of a floating offshore wind turbine (FOWT) together with the controller. WEIS will utilize a multifidelity library of models built upon the foundations of WISDEM and OpenFAST (formerly known as FAST). This paper presents the WEIS development plan, including the functional requirements of WEIS (including improvements to WISDEM and OpenFAST) together with associated rationale for their establishment, and a qualitative description of the modeling approaches that will be implemented to address these functional requirements. The development of WEIS is a project under the Aerodynamic Turbines, Lighter and Afloat, with Nautical Technologies and Integrated Servo-control (ATLANTIS) program funded by the U.S. Department of Energy (DOE) Advanced Research Projects Agency - Energy (ARPA-E).

27 ARPA - Advanced Research Projects Agency-Energy↗

F and N Rich Solid Electrolyte for Stable All-Solid-State Battery

We report the instability of sulfide solid electrolytes to Li anode and high-voltage LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) cathodes limits the cyclic performance of all-solid-state lithium battery (ASSLB). Herein, the stability of Li 6 PS 5 Cl against Li anode is enhanced by mixing a small amount (0.32 wt%) of CuF 2 -LiNO 3 (CL) into Li 6 PS 5 Cl electrolyte layer to in-situ form a mixed-conductive-lithiophobic and self-healing LiF-Li 3 N-Cu solid electrolyte interphase (SEI) at Li 6 PS 5 Cl-CL/Li interface. The critical current density (CCD) of Li 6 PS 5 Cl-CuF 2 -LiNO 3 increases to 1.4 mA cm –2 /1.4 mAh cm –2 at room temperature, which is much higher than that of pristine Li 6 PS 5 Cl (0.4 mA cm –2 /0.4 mAh cm –2 ) even though mixing 0.32 wt% CL into Li 6 PS 5 Cl slightly reduces the ionic conductivity from 2.9 × 10 –3 to 1.5 × 10 –3 S cm –1 . The compatibility of Li 6 PS 5 Cl-CL electrolyte to single-crystalline NMC811 (S-NMC811) is further enhanced by adding a small amount (0.02 wt%) of AlF 3 into Li 6 PS 5 Cl-CL forming Li 6 PS 5 Cl-CuF 2- LiNO 3 -AlF 3 (Li 6 >PS 5 Cl-CLA) as a cathode electrolyte and by doing Cl – on S-NMC811 (Cl@S-NMC811) surface. The Cl@S-NMC811-Li 6 PS 5 Cl-CLA|Li 6 PS 5 Cl-CL|Li cells with areal capacity of 2.55 mAh cm -2 achieve a capacity retention of 69.4% after 100 cycles at 1C (1C = 200 mAh g -1 ). Adding a small amount of SEI and cathode/electrolyte interphase (CEI) former into the sulfide electrolytes with minimal reduction (48.3%) of ionic conductivity is an effective method to enhance the performance of ASSLB.

36 MATERIALS SCIENCE↗

Understanding the Role of Borohydride Doping in Electrochemical Stability of Argyrodite Li 6 PS 5 Cl Solid‐State Electrolyte

This work elucidates the mechanism by which lithium borohydride (LiBH 4 ) doping into argyrodite-type Li 6 PS 5 Cl (LBH-LPSCl) solid-state electrolyte (SSE) enhances electrochemical stability. State-of-the-art electrochemical performance is achieved with 5 wt% borohydride. Symmetric cells achieve critical current density (CCD) of 7.3 mA cm −2 , versus 2.6 mA cm −2 for baseline-LPSCl. All solid-state batteries (ASSBs) employing lithium metal and NMC811 cathode are stable over 400 cycles at 0.5C, with capacity retention of 83%. An anode-free ASSB (AF-ASSB) is stable over 600 cycles, with capacity loss of 0.04% per cycle. 5LBH-LPSCl allows for enhanced low temperature operation, down to −14 °C. Yet the difference in electrolytes’ bulk microstructures and hardnesses are minimal, while ionic conductivity is incrementally improved (≈50%). Theoretical modeling indicates limited effect of substitution on thermodynamic stability of PS 4 3- units, which decompose when contacting Li. Instead, enhanced electrochemical stability is site-specific kinetic effect: In situ electrodeposition experiments using X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (TOF-SIMS) reveal tri-layer SEI based predominately on Li 3 P/LiBH 4 /Li 2 S that blocks electrons while facilitating ion transport. This SEI manifests reduced interface resistance and accelerated nucleation and growth of metallic Li. With baseline-LPSCl the SEI based on Li 3 P/Li 2 S is substantially thicker, generating localized stresses that promote interfacial cracking while cycling.

argyrodite↗

Reactive Carbide‐Based Synthesis and Microstructure of NASICON Sodium Metal All Solid‐State Electrolyte

Reactive carbide precursor-based synthesis of NASICON-type NZSP (Na 1+x Zr 2 Si x P 3-x O 12 ) solid-state electrolyte (SSE) is demonstrated, in contrast to the established oxide-based approach. Exothermic decomposition of ZrC and SiC in air homogenizes microstructure, yielding 98% compact density after conventional sintering at 1200 °C. Quantitative stereology demonstrates that significant microstructural differences are present. Compacts of carbide-derived Carb-NZSP are 98% dense with a secondary zirconium oxide (ZrO 2 ) volume fraction of 0.2% ± 0.3%, versus 93% dense and 3% ± 1% for oxide-derived baseline. For Carb-NZSP, the secondary glassy phosphate phase is agglomerated, while for baseline, it is dispersed and percolated. Electrochemical testing combined with post-mortem analysis demonstrates how microstructural control of secondary phases is critical for dendrite suppression: Carb-NZSP critical current density (CCD) is 3.1 ± 0.8 mA cm −2 at 0.1 mAh cm −2 , versus 1.0 ± 0.7 mA cm −2 at 0.1 mAh cm −2 . Cryogenic focused ion beam (cryo-FIB) analysis demonstrates that in both materials, the porous 2D sheet-like sodium metal dendrites propagate around and subsume NZSP grains, likely following a path enriched with glassy phase and with porosity. Dendrites also flow around isolated zirconia particles. Phase field simulation reveals deflection of dendrites by mechanically tough zirconia, while brittle glassy phase accelerates dendrite growth, especially when finely distributed.

36 MATERIALS SCIENCE↗

Interface Design for High‐Performance All‐Solid‐State Lithium Batteries

All‐solid‐state batteries suffer from high interface resistance and lithium dendrite growth leading to low Li plating/stripping Coulombic efficiency (CE) of <90% and low critical current density at high capacity. Here, in this work, both challenges are simultaneously addressed and the Li plating/stripping CE is significantly increased to 99.6% at 0.2 mA cm −2 /0.2 mAh cm −2 , and critical current density (CCD) of > 3.0 mA cm −2 /3.0 mAh cm −2 by inserting a mixed ionic‐electronic conductive (MIEC) and lithiophobic LiF‐C‐Li 3 N‐Bi nanocomposite interlayer between Li 6 PS 5 Cl electrolyte and Li anode. The highly lithiophobic LiF‐C‐Li 3 N‐Bi interlayer with high ionic conductivity (10 −5 S cm −1 ) and low electronic conductivity (3.4×10 −7 S cm −1 ) enables Li to plate on the current collector (CC) surface rather than on Li 6 PS 5 Cl surface avoiding Li 6 PS 5 Cl electrolyte reduction. During initial Li plating on CC, Li penetrates into porous LiF‐C‐Li 3 N‐Bi interlayer and lithiates Bi nanoparticles into Li 3 Bi. The lithiophilic Li 3 Bi and Li 3 N nanoparticles in LiF‐C‐Li 3 N‐Li 3 Bi sub‐interlayer will move to CC along with plated Li, forming LiF‐C/Li 3 N‐Li 3 Bi lithiophobic/lithiophilic sublayer during the following Li stripping. This interlayer enables Co 0.1 Fe 0.9 S 2 /Li 6 PS 5 Cl/Li cell with an areal capacity of 1.4 mAh cm −2 to achieve a cycle life of >850 cycles at 150 mA g −1 . The lithiophobic/lithiophilic interlayer enables solid‐state metal batteries to simultaneously achieve high energy and long cycle life.

25 ENERGY STORAGE↗

High-Throughput Screening of Catalytic H 2 Production

Hydrogenases, ferredoxins, and ferredoxin-NADP + reductases (FNR) are redox proteins that mediate electron metabolism in vivo, and are also potential components for biological H 2 production technologies. A high-throughput H 2 production assay device (H 2 PAD) is presented that enables simultaneous evaluation of 96 individual H 2 production reactions to identify components that improve performance. Using a CCD camera and image analysis software, H 2 PAD senses the chemo-optical response of Pd/WO 3 thin films to the H 2 produced. H 2 PAD-enabled discovery of hydrogenase and FNR mutants that enhance biological H 2 production is reported. From a library of 10 080 randomly mutated Clostridium pasteurianum [FeFe] hydrogenases, we found a mutant with nearly 3-fold higher H 2 production specific activity. From a library of 400 semi-randomly mutated Oryza sativa FNR, the top hit enabled a 60 % increase in NADPH-driven H 2 production rates. H 2 PAD can also facilitate elucidation of fundamental biochemical mechanisms within these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reduced‐cost sparsity‐exploiting algorithm for solving coupled‐cluster equations

We present an algorithm for reducing the computational work involved in coupled‐cluster (CC) calculations by sparsifying the amplitude correction within a CC amplitude update procedure. We provide a theoretical justification for this approach, which is based on the convergence theory of inexact Newton iterations. We demonstrate by numerical examples that, in the simplest case of the CCD equations, we can sparsify the amplitude correction by setting, on average, roughly 90% nonzero elements to zeros without a major effect on the convergence of the inexact Newton iterations.

Brabec, Jiri↗

Conformational flexibility of BECN1: Essential to its key role in autophagy and beyond: BECN1 Structure and Mechanism

BECN1 (Beclin 1), a highly conserved eukaryotic protein, is a key regulator of autophagy, a cellular homeostasis pathway, and also participates in vacuolar protein sorting, endocytic trafficking, and apoptosis. BECN1 is important for embryonic development, the innate immune response, tumor suppression, and protection against neurodegenerative disorders, diabetes, and heart disease. BECN1 mediates autophagy as a core component of the class III phosphatidylinositol 3-kinase complexes. However, the exact mechanism by which it regulates the activity of these complexes, or mediates its other diverse functions is unclear. BECN1 interacts with several diverse protein partners, perhaps serving as a scaffold or interaction hub for autophagy. Based on extensive structural, biophysical and bioinformatics analyses, BECN1 consists of an intrinsically disordered region (IDR), which includes a BH3 homology domain (BH3D); a flexible helical domain (FHD); a coiled-coil domain (CCD); and a β-α-repeated autophagy-specific domain (BARAD). Each of these BECN1 domains mediates multiple diverse interactions that involve concomitant conformational changes. Thus, BECN1 conformational flexibility likely plays a key role in facilitating diverse protein interactions. Further, BECN1 conformation and interactions are also modulated by numerous post-translational modifications. A better structure-based understanding of the interplay between different BECN1 conformational and binding states, and the impact of post-translational modifications will be essential to elucidating the mechanism of its multiple biological roles.

59 BASIC BIOLOGICAL SCIENCES↗

An approach to characterizing spatial aspects of image system blur

Quantitative X-ray radiographic imaging systems that utilize a charged couple device (CCD) camera connected to a thick, monolithic scintillator can exhibit blur that varies spatially across the field of view, especially for thick scintillators used in pulse-power radiography of dynamically compressed objects. Here, a three-point approach to estimating and accounting for this effect is demonstrated by (a) using a local estimation technique to measure the effect of blurring a calibration object at key locations across the field of view, (b) combining each of the local estimates into a spatially varying blurring function via partitions of unity interpolation, and (c) resolving the effects of that blur on the image by solving an ill-posed inverse problem using a spatially varying regularization term. The technique is demonstrated on synthetic examples and actual radiographs collected at the Naval Research Laboratory’s (NRL)Mercury pulsed power facility.

97 MATHEMATICS AND COMPUTING↗