Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Cavity dynamics and particle alignment in the wake of a supersonic projectile penetrating a dusty plasma

The penetration of a projectile into a strongly coupled dusty plasma was studied in a radio-frequency discharge under microgravity conditions. A supersonic projectile produces an elongated dust-free cavity in its wake. The dynamics of the cavity is analyzed and compared with Langevin dynamics simulations. Besides a three-dimensional Mach cone structure, the simulation shows that the cavity dynamics can be subdivided into three phases: An opening phase with fixed time scale, a closing phase, whose duration is affected by the projectile speed and, finally, a phase of particle realignment in the target cloud, which persists for a long time after the closure of the cavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Asymmetric Bimodal Accelerator Cavity for Raising rf Breakdown Thresholds

We consider an axisymmetric microwave cavity for an accelerator structure whose eigenfrequency for its second lowest TM-like axisymmetric mode is twice that of the lowest such mode, and for which the fields are asymmetric along its axis. In this cavity, the peak amplitude of the rf electric field that points into either longitudinal face can be smaller than the peak field which points out. Computations show that a structure using such cavities might support an accelerating gradient about 47% greater than that for a structure using similar single-mode cavities, without an increase in breakdown probability.

43 PARTICLE ACCELERATORS↗

Evidence of high-field radio-frequency hot-spots due to trapped vortices in niobium cavities

Superconducting radio-frequency (rf) cavities made of high-purity niobium exhibit strong anomalous rf losses starting at peak surface magnetic fields of about 90-100 mT in the gigahertz range. This phenomenon is referred to as "Q-drop". Temperature maps of the cavity surface have revealed the presence of "hot-spots" in the high magnetic field region of the cavities. Several models have been proposed over the years to explain this phenomenon but there is still no experimental evidence on the mechanisms behind such hot-spots. In this work we show that at least some of the hotspots are due to trapped vortices responsible for the anomalous losses. Here we report experiments in which a local thermal gradient was applied to the hot-spot regions of a cavity in order to displace the vortices. Temperature maps measured before and after applying the thermal gradient unambiguously show that the hotspot do move and change their intensities, allowing us to determine changes in

43 PARTICLE ACCELERATORS↗

Electromagnetic design of the RF cavity beam position monitor for the LCLS.

A high-resolution X-band cavity BPM has been developed for the LCLS. A dipole mode cavity and a monopole mode reference cavity have been designed in order to achieve micron-level accuracy of the beam position. The rf properties of the BPM as well as beam interaction with the cavities will be discussed including output power and tuning. In addition, methods will be presented for improving the isolation of the output ports to differentiate between horizontal/vertical beam motion and to reject extraneous modes from affecting the output signal. The predicted simulation results will be compared to data collected from low-power experimental tests.

43 PARTICLE ACCELERATORS↗

The Advanced Photon Source pulsed deflecting cavity RF system.

The Advanced Photon Source Deflecting Cavity System for producing short X-ray pulses uses two multi-cell, S-band cavities to apply a deflecting voltage to the stored electron beam ahead of an undulator that supports a beamline utilizing picosecond X-rays. Two additional multi-cell cavities are then used to cancel out the perturbation and restore the electron beam to its nominal orbit. The pulsed rf system driving the deflecting cavities is described. Design tradeoffs are discussed with emphasis on topology considerations and digital control loops making use of sampling technology in a manner consistent with the present state of the art.

43 PARTICLE ACCELERATORS↗

Insight to the Duration of 120 °C Baking on the Performance of SRF Niobium Cavities

Low-temperature baking at 100 °C - 140 °C in ultra-high vacuum for several hours is the final cavity processing technique to achieve the highest accelerating gradient cavity by eliminating the high field Q-slope, typically on cavities made of high purity fine grain niobium and subjected to electropolishing. The temperature and duration of baking control the onset of the high field Q-slope and overall quality factor over the baseline measurements. The increase in quality factor is generally related to the reduction in the temperature-dependent surface resistance, which refers to BCS surface resistance due to the reduction in the electronic mean free path and elimination of high field Q-slope is still being actively investigated. Here, we present the results of a series of measurements on 1.3 GHz TESLA shape single-cell cavities with successive low-temperature baking at 120 °C up to 96 hours. The rf loss related to the trapping of residual magnetic field refer to flux trapping sensitivity was measured with respect to the duration of 120 °C bake.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 05: Not all geometries are equivalent for magnetic field Fano cavity tests

The coupling of MRI and radiation treatment systems for the application of magnetic resonance guided radiation therapy necessitates a reliable magnetic field capable Monte Carlo (MC) code. In addition to the influence of the magnetic field on dose distributions, the question of proper calibration has arisen due to the several percent variation of ion chamber and solid state detector responses in magnetic fields when compared to the 0 T case (Reynolds et al., Med Phys, 2013). In the absence of a magnetic field, EGSnrc has been shown to pass the Fano cavity test (a rigorous benchmarking tool of MC codes) at the 0.1 % level (Kawrakow, Med.Phys, 2000), and similar results should be required of magnetic field capable MC algorithms. To properly test such developing MC codes, the Fano cavity theorem has been adapted to function in a magnetic field (Bouchard et al., PMB, 2015). In this work, the Fano cavity test is applied in a slab and ion-chamber-like geometries to test the transport options of an implemented magnetic field algorithm in EGSnrc. Results show that the deviation of the MC dose from the expected Fano cavity theory value is highly sensitive to the choice of geometry, and the ion chamber geometry appears to pass the test more easily than larger slab geometries. As magnetic field MC codes begin to be used for dose simulations and correction factor calculations, care must be taken to apply the most rigorous Fano test geometries to ensure reliability of such algorithms.

60 APPLIED LIFE SCIENCES↗

A Design and New Functionality of Antiwaveguiding Vertical-Cavity Surface-Emitting Lasers for a Wavelength of 850 nm

Vertical-cavity surface-emitting lasers (VCSELs) with an aperture limited by an oxide and a resonance cavity based on GaAlAs with high Al content provide a maximum γ factor (λ/2 design) and suppression of optical power beyond the aperture. A VCSEL with two coupled cavities provides additional sharp growth of the loss of high-order lateral modes by leakage to the oxidized region and provides single-mode laser generation for an aperture diameter of up to 5 μm. Single-mode antiwaveguiding VCSELs provide ultrafast data transmission with a rate of up to 160 Gbit/s. The structure in which the active medium is placed in the lower distributed Bragg reflector and the cavity and the upper distributed Bragg reflector are dielectric, reducing the temperature shift of the radiation wavelength by a factor of 2 (to ∼0.03 nm/K).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensitive Detection of an Erbium Isotope in an Atomic Beam Using Cavity Ring-Down Spectroscopy

Here, we have applied cavity ring-down spectroscopy (CRDS) to the study of the 166Er isotope in an atomic beam. These measurements were realized with an external cavity diode laser tuned to the 400.9 nm atomic transition of erbium and a customized high-finesse ring-down optical cavity under vacuum. Erbium atomic beams of different number densities were generated in a tantalum foil micro-crucible within the cavity. Absorbance values of the 166Er isotope between 3 × 10–6 and 7 × 10–5 were measured with a best-case precision on the order of 10–6, which is remarkable when considering the extreme temperatures at which the measurements were conducted, and the short detection path which is characteristic of collimated atomic beams. Number densities of erbium atoms were inferred to be between 2 × 106 and 6 × 107 cm–3. This work demonstrates for the first time the ability of studying dilute atomic beams of refractory materials with high accuracy utilizing CRDS. In these initial studies, we used erbium as a model system, but we expect to extend the proposed approach to the measurement of isotopes of uranium and plutonium for nuclear non-proliferation applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adaptive frequency comb illumination for interferometry in the case of nested two-beam cavities

The homogeneity test of glass plates in a Fizeau interferometer is hampered by the superposition of multiple interference signals coming from the surfaces of the glass plate as well as the empty Fizeau cavity. To evaluate interferograms resulting from such nested cavities, various approaches such as the use of broadband light sources have been applied. In this paper, we propose an adaptive frequency comb interferometer to accomplish the cavity selection. An adjustable Fabry-Perot resonator is used to generate a variable frequency comb that can be matched to the length of the desired cavity. Owing to its flexibility, the number of measurements needed for the homogeneity test can be reduced to four. Furthermore, compared to approaches using a two-beam interferometer as a filter for the broadband light source, the visibility of the fringe system is considerably higher if a Fabry-Perot filter is applied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface plasmon-cavity hybrid state and its graphene modulation at THz frequencies

Fabry–Pérot (F–P) cavity and metal hole array are classic photonic devices. Integrating F–P cavity with holey metal typically enhances interfacial reflection and dampens wave transmission. In this work, a hybrid bound surface state is found within rectangular metal holes on a silicon substrate by merging an extraordinary optical transmission (EOT) mode and a high-order F–P cavity mode both spatially and spectrally. Transmission, Q-factor, and bandwidth can be enhanced significantly with respect to the classical EOT and F–P interference by simply sweeping the cavity length. This state can provide EOT properties and ten times broader EOT bandwidth well below the effective plasma frequency of the periodic metal holes, where the metal holes typically show evanescent properties and do not support EOT in theory. Furthermore, a large modulation range of 25 % and 39 % is demonstrated with various graphene patterns for the transmittance of this hybrid state at 500 and 582 GHz, respectively.

36 MATERIALS SCIENCE↗

Calibration of the ERL cavity FPC and PU couplers

The performance parameters of a superconducting cavity, notably accelerating field and quality factor, are first obtained in a cryogenic vertical test Dewar, and again after the final assembly in its cryostat. The tests involve Network Analyzer (NA) measurements in which the cavity is excited through an input coupler and the properties are obtained from the reflected signal at the input and the transmitted signal from the output coupler. The interpretation of the scattering coefficients in terms of field strength requires the knowledge of the Fundamental Power Coupler (FPC) and Pick-Up (PU) coupler strength, as expressed by their 'external' and Q{sub FPC} Q{sub PU}. The coupler strength is independent of the field level or cavity losses and thus can be determined at low levels with the scattering coefficients S{sub 11} and S{sub 21}, assuming standard 50 {Omega} terminations in the network analyzer. Also needed is the intrinsic cavity parameter, R{sub a} /Q{sub 0} {triple_bond} {l_brace}R/Q{r_brace}, a quantity independent of field or losses which must be obtained from simulation programs, such as the Microwave Studio.

43 PARTICLE ACCELERATORS↗

The Design of the Orthogonal Box Cavity

The muon collider and/or the neutrino factory require large accelerating electric field gradients immersed in large (3 to 6 T) solenoidal magnetic fields for ionization cooling of muon beams. Our original vacuum breakdown study demonstrated a loss of achievable peak accelerating gradient in solenoidal magnetic fields by a factor 2 or greater. The Muon Collaboration has developed a theory of a method to suppress high electric field breakdown in vacuum cavities needed for a Muon collider or neutrino factory. It has been shown in our studies and by others that high gradient electric field emitted electrons (dark current) are the primary cause of breakdown. A DC magnetic field orthogonal to the RF electric accelerating field prevents dark current high field emitted electrons from traveling across the accelerating gap and then will prevent breakdown. We have decided to test this theory by building a special cavity in the shape of vacuum box. Figure 1 is a simplified view of the cavity design. The design is based on an 805 MHz WR975 waveguide cavity resonating in the TE{sub 101} mode. For the TE{sub 101} mode the resonant frequency f{sub 0} is given by the relationship f{sub 0} = c[(I/a){sup 2} + (m/b){sup 2} + (n/d){sup 2}]{sup 0.5}/2 where a and d are the lengths of the base sides and b is the height of the box in MKS units and c is the velocity of light.

43 PARTICLE ACCELERATORS↗

The Design of the Parallel Box Cavity with New Radial RF Coupler Design

The design of a E/H parallel cavity has been described. It has been designed with the RF simulation program HFSS. HFSS has been very successfully been used to design and fabricate the Orthogonal E/H box cavity. The main reason for this design choice is to move the RF coupling aperture to surface of minimum electric field gradient. It is suspected that this change will remove the damaged observed in the coupling area experimentally observed in the LBL Pillbox cavity. Another reason for this change is that it corresponds to the location of the coupling aperture in a future real experimental cooling channel. Also, with this design the coupling factor to the cavity can be made adjustable externally, a very useful feature.

43 PARTICLE ACCELERATORS↗

Calculation of asymptotic and RMS kicks due to higher order modes in the 3.9-GHz cavity

FLASH plans to use a 'third harmonic' (3.9 GHz) superconducting cavity to compensate nonlinear distortions of the longitudinal phase space due to the sinusoidal curvature of the cavity voltage of the TESLA 1.3 GHz cavities. Higher order modes (HOMs) in the 3.9 GHz have a significant impact on the dynamics of the electron bunches in a long bunch train. Kicks due to dipole modes can be enhanced along the bunch train depending on the frequency and Q-value of the modes. The enhancement factor for a constant beam offset with respect to the cavity has been calculated. A simple Monte Carlo model of these effects, allowing for scatter in HOM frequencies due to manufacturing variances, has also been implemented and results for both FLASH and for an XFEL-like configuration are presented.

43 PARTICLE ACCELERATORS↗

Simulation of RF Cavity Dark Current in Presence of Helical Magnetic Field

In order to produce muon beam of high enough quality to be used for a Muon Collider, its large phase space must be cooled several orders of magnitude. This task can be accomplished by ionization cooling. Ionization cooling consists of passing a high-emittance muon beam alternately through regions of low Z material, such as liquid hydrogen, and very high accelerating RF cavities within a multi-Tesla solenoidal focusing channel. But first high power tests of RF cavity with beryllium windows in solenoidal magnetic field showed a dramatic drop in accelerating gradient due to RF breakdowns. It has been concluded that external magnetic fields parallel to RF electric field significantly modifies the performance of RF cavities. However, magnetic field in Helical Cooling Channel has a strong dipole component in addition to solenoidal one. The dipole component essentially changes electron motion in a cavity compare to pure solenoidal case, making dark current less focused at field emission sites. The simulation of dark current dynamic in HCC performed with CST Studio Suit is presented in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of dissipative regions of a N-doped superconducting radio-frequency cavity

We report radio-frequency measurements of quality factors and temperature mapping of a nitrogen doped Nb superconducting RF cavity. Cavity cutouts of hot and cold spots were studied with low temperature scanning tunneling microscopy and spectroscopy, X-ray photoelectron spectroscopy and secondary electron microscopy. Temperature mapping revealed a substantial reduction of the residual resistance upon cooling the cavity with a greater temperature gradient and hysteretic losses at the quench location, pointing to trapped vortices as the dominant source of residual surface resistance. Analysis of the tunneling spectra in the framework of a proximity effect theory shows that hot spots have a reduced pair potential and a wider distribution of the contact resistance between the Nb and the top Nb oxide. Alone, these degraded superconducting properties account for a much weaker excess dissipation as compared with the vortex contribution. Based on the correlation between the quasiparticle density of states and temperature mapping, we suggest that degraded superconducting properties may facilitate vortex nucleation or settling of trapped flux during cooling the cavity through the critical temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiments on HOM spectrum manipulation in a 1.3 GHz ILC SC cavity

Superconducting cavities with high operating Q will be installed in the Project-X, a superconducting linac, which is under development at Fermilab. Possibility of cavity design without HOM couplers considered. Rich spectrum of the beam and large number of cavities in ProjectX linac can result to resonance excitation of some high order modes with high shunt impedance. Under scope of study of High order modes damping the manipulation with HOM spectrum in cold linac is considered. Results of detuning HOM spectrum of 1.3 GHz cavities at 2K in Horizontal Test Station of Fermilab are presented. Possible explanation of the phenomena is discussed.

43 PARTICLE ACCELERATORS↗