Unveiling dark brown carbon: The hidden light-absorbing aerosols from biomass burning
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Recent Findings from Audits, New Technology Data Reviews a) Disabled Chip Burn-ins A recent audit for a QML device discovered that the chip was disabled during the static burn-in, thus it was not drawing any current. Recommendation: For new SMDs add a statement within the burn-in paragraphs stating that the parts shall be kept in their enabled state during the burn-in. b) Class Q 160-hr/125oC Burn-in This is being interpreted as a static burn-in (even for CMOS technology). Recommendation: Provide clarification in MIL-STD-883, Test Method 5004. c) At Frequency (Dynamic) Burn-ins Test equipment limitation is being cited for not doing burn-ins at the application frequency. Recommendation: The burn-in task group to discuss and provide guidance. When the SMD says that the part can be used at 200 MHz, then doing burn-in at 6 MHz (cited as burn-in equipment limitation frequency) is not going to be meaningful! d) Two Static Burn-ins Some manufacturers are doing electrical testing between the two static burn-ins, whereas others do electricals after completing both static burn-ins. Recommendation: Provide clarification in MIL-STD-883, Test Method 5004. e) Thermal Imaging For a device with hot spots, the thermal resistance, junction-to-case, would be much higher than the guidelines given in MIL-STD-1835. One of the suppliers used thermal imaging to find hot spots on the die. Recommendation: Assign a task group to evaluate the effectiveness of thermal imaging at the product development stage.
The objectives of this program were to establish the feasibility of metallized/liquid oxygen monopropellants and select the best monopropellant formulation for continued study. The metal powders mixed with the liquid oxygen were aluminum/magnesium (80/20), silicon and iron (Iron was only tested for burning properties). The formulations were first evaluated on whether they detonated when ignited or burned. The formulations only burned when ignited. The viscosity for the formulations ranged from 900 cps to 100 cps at shear rates up to 300 seconds(sup -1). Two percent (by weight) of Cab-O-Sil was added to the aluminum and aluminum/magnesium formulations for gelling while the silicon formulation used three percent. Within a seven hour period, settling was suggested only in the 29 percent aluminum and 29 percent aluminum/magnesium formulations. The monopropellants were burned in a cylinder submerged in a liquid nitrogen bath. Experimental data at ambient pressure indicated that the monopropellants were extinguished when the flame front reached regions submerged under the liquid nitrogen. The burn rate increased dramatically when burned in a cylinder enclosure with less heat sink available to the monopropellant. The test results were inconclusive as to whether the increased burn rate was due to the lower heat sink capacity or the small amount of pressure (2 psi) generated during the burning of the monopropellant. The burning of the aluminum and aluminum/magnesium resulted in a brilliant white flame similar to that of an arc welder. These monopropellants burned in a pulsating manner with the aluminum/magnesium appearing to have less pulsating combustion. The silicon monopropellant burned with an orange glow. No sparks or energetic burning was apparent as with the aluminum or aluminum/magnesium.
A series of low gravity, aircraft-based, experiments was conducted to investigate the combustion of supported thermoplastic polymer spheres under varying ambient conditions. The three types of thermoplastic investigated were polymethylmethacrylate (PMMA), polypropylene (PP). and polystyrene (PS). Spheres with diameters ranging from 2 mm to 6.35 mm were tested. The total initial pressure varied from 0.05 MPa to 0. 15 MPa whereas the ambient oxygen concentration varied from 19 % to 30 % (by volume). The ignition system consisted of a pair of retractable energized coils. Two CCD cameras recorded the burning histories of the spheres. The video sequences revealed a number of dynamic events including bubbling and sputtering, as well as soot shell formation and break-up during combustion of the spheres at reduced gravity. The ejection of combusting material from the burning spheres represents a fire hazard that must be considered at reduced gravity. The ejection process was found to be sensitive to polymer type. All average burning rates were measured to increase with initial sphere diameter and oxygen concentration, whereas the initial pressure had little effect. The three thermoplastic types exhibited different burning characteristics. For the same initial conditions, the burning rate of PP was slower than PMMA, whereas the burning rate of PS was comparable to PMMA. The transient diameter of the burning thermoplastic exhibited two distinct periods: an initial period (enduring approximately half of the total burn duration) when the diameter remained approximately constant, and a final period when the square of the diameter linearly decreased with time. A simple homogeneous two-phase model was developed to understand the changing diameter of the burning sphere. Its value is based on a competition between diameter reduction due to mass loss from burning and sputtering, and diameter expansion due to the processes of swelling (density decrease with heating) and bubble growth. The model relies on empirical parameters for input, such as the burning rate and the duration of the initial and final burning periods.
Recent record-breaking wildfire seasons in California prompt an investigation into the climate patterns that typically precede anomalous summer burned forest area. Using burned-area data from the U.S. Forest Service’s Monitoring Trends in Burn Severity (MTBS) product and climate data from the fifth major global reanalysis produced by the European Centre for Medium-Range Weather Forecasts (ERA5) over 1984–2018, relationships between the interannual variability of antecedent climate anomalies and July California burned area are spatially and temporally characterized. Lag correlations show that antecedent high vapor pressure deficit (VPD), high temperatures, frequent extreme high temperature days, low precipitation, high subsidence, high geopotential height, low soil moisture, and low snowpack and snowmelt anomalies all correlate significantly with July California burned area as far back as the January before the fire season. Seasonal regression maps indicate that a global midlatitude atmospheric wave train in late winter is associated with anomalous July California burned area. July 2018, a year with especially high burned area, was to some extent consistent with the general patterns revealed by the regressions: low winter precipitation and high spring VPD preceded the extreme burned area. However, geopotential height anomaly patterns were distinct from those in the regressions. Extreme July heat likely contributed to the extent of the fires ignited that month, even though extreme July temperatures do not historically significantly correlate with July burned area. While the 2018 antecedent climate conditions were typical of a high-burned-area year, they were not extreme, demonstrating the likely limits of statistical prediction of extreme fire seasons and the need for individual case studies of extreme years.
Flammability experiments on silicone samples were conducted in anticipation of the Spacecraft Fire Experiment (Saffire). The sample geometry was chosen to match the NASA 6001 Test 1 specification, namely 5 cm wide by 30 cm tall. Four thicknesses of silicone (0.25, 0.36, 0.61 and 1.00 mm) were examined. Tests included traditional upward buoyant flame spread using Test 1 procedures, downward opposed flow flame spread, horizontal and angled flame spread, forced flow upward and downward flame spread. In addition to these configurations, upward and downward tests were also conducted in a chamber with varying oxygen concentrations. In the upward buoyant flame spread tests, the flame generally did not burn the entire sample. As thickness was increased, the flame spread distance decreased before flame extinguishment. For the thickest sample, ignition could not be achieved. In the downward tests, the two thinnest samples permitted the flame to burn the entire sample, but the spread rate was lower compared to the corresponding upward values. The other two thicknesses could not be ignited in the downward configuration. The increased flammability for downward spreading flames relative to upward ones is uncommon. The two thinnest samples also burned completely in the horizontal configuration, as well as at angles up to 75 degrees from the horizontal. The upward and downward flammability behavior was compared in atmospheres of varying oxygen concentration to determine a maximum oxygen concentration for each configuration. Upward tests in air with an added forced flow were more flammable. Complementary analyses using SEM and TGA techniques suggest the importance of the silica layer formed on the burned sample surface. As silicone burns upward, silica deposits downstream •If the silicone is ignited in the downward configuration, it burns the entire length of the sample •Burning upward at an angle increases the burn length in some cases possibly due to less silica deposition •Forced flow in the upward burning case increases flammability, likely due to an increase in convective flow preventing silica from depositing •Samples in upward configuration burning under forced flow self extinguish after forced flow is removed
Following the first Nuclear Thermal Propulsion (NTP) system test, also known as DRACO, the next NTP system to be developed would be the 1st Generation NTP system. An analysis was conducted to determine the performance of different vehicle configurations utilizing hydrogen (H-NTP), ammonia (A-NTP), and methane (M-NTP) as propellants launched onboard commercial launch vehicles. This was enabled by a quasi-steady-state power balance engine model and vehicle component physics that sized the vehicle system using Master Equipment List (MEL) parameters. The analysis considered configuration cases outlined by a matrix of different mission classes and vehicle configurations that covered the design space of the 1st Generation NTP system to explore various propellant options, engine architectures, and mission scopes. Four mission classes were evaluated which included single burn missions performing maneuvers having a ΔV of 1 km/s and 2.5 km/s followed by 2-burn and 4-burn missions that aimed to exhaust the launch vehicles volume or mass limitations. In all cases, the NTP systems with the lowest thrust class had the longest burn time of which A-NTP and M-NTP systems provided the longest and shortest burn times depending on the launch vehicle used while H-NTP systems tended to cluster together in the middle. Longer burn times could be useful as a testing platform to increase the time for data accumulation. Across the multi-burn cases, H-NTP systems were found to be volume limited while A-NTP and M-NTP systems were mass limited. Both single burn missions showed that A-NTP configurations provided the lowest dry mass given that ammonia had the highest density with comparable performance to M-NTP systems and no requirement for cryocoolers. The results showed that beyond the propellant selection type, the launch vehicle selection, which included Starship, New Glenn, Vulcan, Falcon 9 (recoverable), and Falcon Heavy (recoverable), was a primary driving factor in the test vehicle’s capabilities. Trends were determined based on a set of dimensionless parameters that included the mass ratio of inert mass to initial wetted mass, ratio of specific impulse to burn time, and a dimensionless engine parameter (ratio of impulse to engine momentum). These relationships found the “knees-in-the-curves” that could be a significant point of reference for the designer as they indicate a change in the trend which is located at a specific impulse to burn time ratio of 1, a mass ratio of 0.6, and an engine performance parameter of 4. This study did not attempt to make a recommendation rather provide the tools for the reader to select their own configuration based on their needs.
Following the first Nuclear Thermal Propulsion (NTP) system test, also known as DRACO, the next NTP system to be developed would be the 1st Generation NTP system. An analysis was conducted to determine the performance of different vehicle configurations utilizing hydrogen (H-NTP), ammonia (A-NTP), and methane (M-NTP) as propellants launched onboard commercial launch vehicles. This was enabled by a quasi-steady-state power balance engine model and vehicle component physics that sized the vehicle system using Master Equipment List (MEL) parameters. The analysis considered configuration cases outlined by a matrix of different mission classes and vehicle configurations that covered the design space of the 1st Generation NTP system to explore various propellant options, engine architectures, and mission scopes. Four mission classes were evaluated which included single burn missions performing maneuvers having a ΔV of 1 km/s and 2.5 km/s followed by 2-burn and 4-burn missions that aimed to exhaust the launch vehicles volume or mass limitations. In all cases, the NTP systems with the lowest thrust class had the longest burn time of which A-NTP and M-NTP systems provided the longest and shortest burn times depending on the launch vehicle used while H-NTP systems tended to cluster together in the middle. Longer burn times could be useful as a testing platform to increase the time for data accumulation. Across the multi-burn cases, H-NTP systems were found to be volume limited while A-NTP and M-NTP systems were mass limited. Both single burn missions showed that A-NTP configurations provided the lowest dry mass given that ammonia had the highest density with comparable performance to M-NTP systems and no requirement for cryocoolers. The results showed that beyond the propellant selection type, the launch vehicle selection, which included Starship, New Glenn, Vulcan, Falcon 9 (recoverable), and Falcon Heavy (recoverable), was a primary driving factor in the test vehicle’s capabilities. Trends were determined based on a set of dimensionless parameters that included the mass ratio of inert mass to initial wetted mass, ratio of specific impulse to burn time, and a dimensionless engine parameter (ratio of impulse to engine momentum). These relationships found the “knees-in-the-curves” that could be a significant point of reference for the designer as they indicate a change in the trend which is located at a specific impulse to burn time ratio of 1, a mass ratio of 0.6, and an engine performance parameter of 4. This study did not attempt to make a recommendation rather provide the tools for the reader to select their own configuration based on their needs.
Following the first Nuclear Thermal Propulsion (NTP) system test, also known as DRACO, the next NTP system to be developed would be the 1st Generation NTP system. An analysis was conducted to determine the performance of different vehicle configurations utilizing hydrogen (H-NTP), ammonia (A-NTP), and methane (M-NTP) as propellants launched onboard commercial launch vehicles. This was enabled by a quasi-steady-state power balance engine model and vehicle component physics that sized the vehicle system using Master Equipment List (MEL) parameters. The analysis considered configuration cases outlined by a matrix of different mission classes and vehicle configurations that covered the design space of the 1st Generation NTP system to explore various propellant options, engine architectures, and mission scopes. Four mission classes were evaluated which included single burn missions performing maneuvers having a ΔV of 1 km/s and 2.5 km/s followed by 2-burn and 4-burn missions that aimed to exhaust the launch vehicles volume or mass limitations. In all cases, the NTP systems with the lowest thrust class had the longest burn time of which A-NTP and M-NTP systems provided the longest and shortest burn times depending on the launch vehicle used while H-NTP systems tended to cluster together in the middle. Longer burn times could be useful as a testing platform to increase the time for data accumulation. Across the multi-burn cases, H-NTP systems were found to be volume limited while A-NTP and M-NTP systems were mass limited. Both single burn missions showed that A-NTP configurations provided the lowest dry mass given that ammonia had the highest density with comparable performance to M-NTP systems and no requirement for cryocoolers. The results showed that beyond the propellant selection type, the launch vehicle selection, which included Starship, New Glenn, Vulcan, Falcon 9 (recoverable), and Falcon Heavy (recoverable), was a primary driving factor in the test vehicle’s capabilities. Trends were determined based on a set of dimensionless parameters that included the mass ratio of inert mass to initial wetted mass, ratio of specific impulse to burn time, and a dimensionless engine parameter (ratio of impulse to engine momentum). These relationships found the “knees-in-the-curves” that could be a significant point of reference for the designer as they indicate a change in the trend which is located at a specific impulse to burn time ratio of 1, a mass ratio of 0.6, and an engine performance parameter of 4. This study did not attempt to make a recommendation rather provide the tools for the reader to select their own configuration based on their needs.
The tritium aspects of the DT fuel cycle embody some of the most challenging feasibility and attractiveness issues in the development of fusion systems. The review and analyses in this paper provide important information to understand and quantify these challenges and to define the phase space of plasma physics and fusion technology parameters and features that must guide a serious R&D in the world fusion program. We focus in particular on components, issues and R&D necessary to satisfy three 'principal requirements': (1) achieving tritium self-sufficiency within the fusion system, (2) providing a tritium inventory for the initial start-up of a fusion facility, and (3) managing the safety and biological hazards of tritium. A primary conclusion is that the physics and technology state-of-the-art will not enable DEMO and future power plants to satisfy these principal requirements. We quantify goals and define specific areas and ideas for physics and technology R&D to meet these requirements. A powerful fuel cycle dynamics model was developed to calculate time-dependent tritium inventories and flow rates in all parts and components of the fuel cycle for different ranges of parameters and physics and technology conditions. Dynamics modeling analyses show that the key parameters affecting tritium inventories, tritium start-up inventory, and tritium self-sufficiency are the tritium burn fraction in the plasma (f b ), fueling efficiency (η f ), processing time of plasma exhaust in the inner fuel cycle (t p ), reactor availability factor (AF), reserve time (tr) which determines the reserve tritium inventory needed in the storage system in order to keep the plant operational for time t r in case of any malfunction of any part of the tritium processing system, and the doubling time (t d ). Results show that η f f b > 2% and processing time of 1–4 h are required to achieve tritium self-sufficiency with reasonable confidence. For η f f b = 2% and processing time of 4 h, the tritium start-up inventory required for a 3 GW fusion reactor is ~11 kg, while it is <5 kg if η f f b = 5% and the processing time is 1 h. To achieve these stringent requirements, a serious R&D program in physics and technology is necessary. The EU-DEMO direct internal recycling concept that carries fuel directly from the plasma exhaust gas to the fueling systems without going through the isotope separation system reduces the overall processing time and tritium inventories and has positive effects on the required tritium breeding ratio (TBR R ). A significant finding is the strong dependence of tritium self-sufficiency on the reactor availability factor. Simulations show that tritium self-sufficiency is: impossible if AF < 10% for any η f f b , possible if AF > 30% and 1% ≤ η f f b ≤ 2%, and achievable with reasonable confidence if AF > 50% and η f f b > 2%. These results are of particular concern in light of the low availability factor predicted for the near-term plasma-based experimental facilities (e.g. FNSF, VNS, CTF), and can have repercussions on tritium economy in DEMO reactors as well, unless significant advancements in RAMI are made. There is a linear dependency between the tritium start-up inventory and the fusion power. The required tritium start-up inventory for a fusion facility of 100 MW fusion power is as small as 1 kg. Since fusion power plants will have large powers for better economics, it is important to maintain a 'reserve' tritium inventory in the tritium storage system to continue to fuel the plasma and avoid plant shutdown in case of malfunctions of some parts of the tritium processing lines. But our results show that a reserve time as short as 24 h leads to unacceptable reserve and start-up inventory requirements. Therefore, high reliability and fast maintainability of all components in the fuel cycle are necessary in order to avoid the need for storing reserve tritium inventory sufficient for continued fusion facility operation for more than a few hours. The physics aspects of plasma fueling, tritium burn fraction, and particle and power exhaust are highly interrelated and complex, and predictions for DEMO and power reactors are highly uncertain because of lack of experiments with burning plasma. Fueling by pellet injection on the high field side of tokamak has evolved to be the preferred method to fuel a burning plasma. Extrapolation from the DIII-D penetration scaling shows fueling efficiency expected in DEMO to be <25%, but such extrapolations are highly uncertain. The fueling efficiency of gas in a reactor relevant regime is expected to be extremely poor and not very useful for getting tritium into the core plasma efficiently. Gas fueling will nonetheless be useful for feedback control of the divertor operating parameters. Extensive modeling has been carried out to predict burn fraction, fueling requirements, and fueling efficiency for ITER, DEMO, and beyond. The fueling rate required to operate Q = 10 ITER plasmas in order to provide the required core fueling, helium exhaust and radiative divertor plasma conditions for acceptable divertor power loads was calculated. If this fueling is performed with a 50–50 DT mix, the tritium burn fraction in ITER would be ~0.36%, which is too low to satisfy the self-sufficiency conditions derived from the dynamics modeling for fusion reactors. Extrapolation to DEMO using this approach would also yield similarly low burn fraction. Extensive analysis presented shows that specific features of edge neutral dynamics in ITER and fusion reactors, which are different from present experiments, open possibilities for optimization of tritium fueling and thus to improve the burn fraction. Using only tritium in pellet fueling of the plasma core, and only deuterium for edge density, divertor power load and ELM control results in significant increase of the burn fraction to 1.8–3.6%. These estimates are performed with physics models whose results cannot be fully validated for ITER and DEMO plasma conditions since these cannot be achieved in present tokamak experiments. Thus, several uncertainties remain regarding particle transport and scenario requirements in ITER and DEMO. The safety standard requirements for protection of the public and release guidelines for tritium have been reviewed. General safety approaches including minimizing tritium inventories, reducing tritium permeation through materials, and decontaminating material for waste disposal have been suggested.
Abstract Post-fire harvest (PFH) is a forest management practice designed to salvage value from burned timber, mitigate safety hazards from dead trees, reduce long-term fuels, and prepare sites for replanting. Despite public controversy and extensive ecological research, little is known about how much PFH occurs on private and public lands in the U.S. Pacific West, or how practices changed with shifting forest policy and increasing area burned over the last three decades. We mapped PFH across 2.2M burned hectares in California, Oregon, and Washington between 1986-2017 and used time series intervention analysis to compare trends in area, rate (% of burned area harvested), and mean patch size between private (0.5M ha) and federal (1.6M ha) forest land and across a gradient of burn severity. Harvest rates varied by ownership (4.9% federal, 18.6% private, 8.0% overall), and practices evolved and diverged over the study period. PFH area and rate declined across all ownerships in the mid-1990s during a period of reduced fire activity. As area burned increased between the early 2000s and late 2010s, PFH area rebounded and surpassed late-1980s levels, while rates remained relatively low. On federal lands, PFH practices shifted in the early-to-mid 1990s towards lower rates (10.3% to 3.8%) and smaller patches (6.0 to 3.3 ha), following policy changes and increased litigation. PFH rates on federal lands decreased at all levels of burn severity, with the largest decreases (6.2% to 1.2%) in forests with low tree mortality (i.e. fire refugia). Conversely, private PFH rates and mean patch sizes more than doubled in forests burned at very low-to-moderate severity. Our results highlight how PFH practices have shifted with policy, socio-economic pressure, and increasing area burned over 31 years in the Pacific West. A similar area of post-fire harvest is now dispersed over larger fires, with practices diverging substantially between ownerships.
The author has identified the following significant results. Considerable regrowth of vegetation was observed between August 1977 and August 1978, both in the field and through analysis of LANDSAT near infrared digital data. The spectral reflectances in the burned areas were found to increase with the age of the burn in a one year period due to vegetation regrowth. Regrowth was particularly evident in the lightly burned portions of the burned area. Image analysis techniques using the AOIPS system permitted delineation of burn severity categories. The conditions and type of ground cover prior to the fire influenced the severity of burning, as did the direction of the winds while the burning was in progress as determined from field and LANDSAT observations. More severe burning was induced by winds blowing in the northeastern and southeastern portions of the burned area.
Investigations into droplet interactions date back to Rex et al. Recently, Annamalai and Ryan and Annamalai published extensive reviews of droplet array and cloud combustion studies. The authors studied the change in the burning rate constant, k, (relative to that of the single droplet) that results from interactions. Under certain conditions, there exists a separation distance where the droplet lifetime reaches a minimum, or average burning rate constant is a maximum . Additionally, since inter-droplet separation distance, L, increases relative to the droplet size, D, as the burning proceeds, the burning rate is not constant throughout the burn, but changes continuously with time. Only Law and co-workers and Mikami et al. studied interactions under conditions where buoyant forces were negligible. Comparing their results with existing theory, Law and co-workers found that theory over predicted the persistency and intensity of droplet interactions. The droplet interactions also depended on the initial array configuration as well as the instantaneous array configuration. They also concluded that droplet heating was retarded due to interactions and that the burning process did not follow the "D-squared" law. Mikami et al. studied the combustion of a two-droplet array of heptane burning in air at one atm pressure in microgravity. They showed that the instantaneous burning rate constant increases throughout the droplet lifetime, even for a single droplet. Also, the burn time of the array reached a minimum at a critical inter-droplet spacing. In this article, we examine droplet interactions in normal and microgravity environments. The microgravity experiments were in the NASA GRC 2.2 and 5.2 second drop towers, and the JAMIC (Japan Microgravity Center) 10 second drop tower. Special emphasis is directed to combustion under conditions that yield finite extinction diameters, and to determine how droplet interactions affect the extinction process.
A major portion of the energy produced in the world today comes from the burning of liquid hydrocarbon fuels in the form of droplets. Understanding the fundamental physical processes involved in droplet combustion is not only important in energy production but also in propulsion, in the mitigation of combustion-generated pollution, and in the control of the fire hazards associated with handling liquid combustibles. Microgravity makes spherically symmetric combustion possible, allowing investigators to easily validate their droplet models without the complicating effects of gravity. The Fiber-Supported Droplet Combustion (FSDC-2) investigation was conducted in the Microgravity Glovebox facility of the shuttles' Spacelab during the reflight of the Microgravity Science Laboratory (MSL- 1R) on STS-94 in July 1997. FSDC-2 studied fundamental phenomena related to liquid fuel droplet combustion in air. Pure fuels and mixtures of fuels were burned as isolated single and duo droplets with and without forced air convection. FSDC-2 is sponsored by the NASA Lewis Research Center, whose researchers are working in cooperation with several investigators from industry and academia. The rate at which a droplet burns is important in many commercial applications. The classical theory of droplet burning assumes that, for an isolated, spherically symmetric, single-fuel droplet, the gas-phase combustion processes are much faster than the droplet surface regression rate and that the liquid phase is at a uniform temperature equal to the boiling point. Recent, more advanced models predict that both the liquid and gas phases are unsteady during a substantial portion of the droplet's burning history, thus affecting the instantaneous and average burning rates, and that flame radiation is a dominant mechanism that can extinguish flames in a microgravity environment. FSDC-2 has provided well-defined, symmetric droplet burning data including radiative emissions to validate these theoretical models for heptane, decane, ethanol, and methanol fuels. Since most commercial combustion systems burn droplets in a convective environment, data were obtained without and with convective flow over the burning droplet (see the following photos).
The nuclear rates for reactions involving 12 C and 16 O are key to computing the energy release and nucleosynthesis evolution of massive stars during their advanced burning phases. Ultimately, these burning rates shape the stellar structure and evolution and influence the nature of the compact objects produced at the end of the stellar life. We explore the implications of new nuclear reaction rates from both experimental and theoretical studies for 12 C(α, γ) 16 O, 12 C+ 12 C, 12 C+ 16 O, and 16 O+ 16 O reactions for massive stars. Our goal is to investigate how the chemical structure and nucleosynthesis evolve from the He-exhaustion stage to the O-burning phase and how these processes influence the ultimate stellar fate. We computed rotating and non-rotating models for stars of different masses at solar metallicity. We used the stellar evolution code GENEC, which includes a large network of nuclear reactions and isotopes involved in advanced phases, as well as updated rates for 12 C(α,γ) 16 O. For the three fusion reactions involving 12 C and 16 O, we considered new rates following a data-driven fusion suppression scenario (hereafter HIN(RES)) and new theoretical rates obtained with time-dependent Hartree-Fock (TDHF) calculations. The updated 12 C(α, γ) 16 O rates mainly impact the chemical structure evolution changing the 12 C/ 16 O ratio at He-exhaustion and have little effect on the CO core mass. This variation in the 12 C/ 16 O ratio is in some cases critical for predicting the final fate of the model, which is very sensitive to 12 C abundance, and in particular the 20 M ⊙ remnant may change from a black hole to a neutron star. The He-burning (C-burning) lifetime is also decreased (increased) by about −2% (+15%). The combined new rates for 12 C+ 12 C and 16 O+ 16 O fusion reactions according to the HIN(RES) model lead to shorter C- and O-burning lifetimes by ≈ − 10%, and −50%, respectively, and shift the ignition conditions to higher temperatures and densities. In contrast, the theoretical TDHF rates primarily affect C-burning, increasing its duration by about 30% and lowering the ignition temperature. These changes modify the chemical structure of the core, the size and duration of C-burning shells, and hence their compactness. They also impact the central and shell nucleosynthesis (by ±1 dex and by factors of ±2–10, respectively), while 12 C+ 16 O reaction rates variations remain the least important.
Understanding thermal stress in tropical forests has taken on new urgency in light of accelerating climate change and expansion of deforestation and forest degradation. Degraded tropical forests in particular may be approaching critical temperature thresholds even more rapidly than intact forests, with implications for tree survival and ecosystem recovery. We investigate thermal stress in degraded tropical forests within the Brazilian Amazon Arc of Deforestation. Using land surface temperature data from the ECOsystem Spaceborne Thermal Radiometer Experiment on the international Space Station (ECOSTRESS), we compared canopy temperatures of intact, selectively logged, and burned forests in Feliz Natal, Mato Grosso, Brazil. Upper canopy temperatures in previously burned forests were 4.1% higher (mean = 36.5 °C) and 50.9% more variable compared to intact and logged forests, which showed remarkably similar temperature distributions (means of 34.9 °C and 35.1 °C, respectively). Modeled leaf temperature distributions based on canopy temperature measurements from one of the warmest days in a 2 year dry season record indicated that 87% of leaves in the warmest burned forest patches exceeded the temperature threshold where respiration surpasses photosynthesis, compared to approximately 72%–74% in intact and logged forests, respectively, in the same time period. After controlling for environmental factors, burned forests were predicted to be 2.6 °C warmer on average [1.39 °C–3.96 °C, 95% credible interval] than intact forests across a 5–40 m canopy height range. Burned forests showed modest thermal recovery over time, with temperatures decreasing by approximately 1.2 °C over a 30 year recovery period. In contrast, logged forests showed minimal thermal differences from intact forests (−0.353 on average, [−1.125–0.274, 95% credible interval]) and negligible change (0.15 °C) over the same timeframe. While the absolute probabilities of exceeding damaging thermal thresholds remain low across all forest types under current climate conditions, the probability of leaves exceeding temperatures that cause permanent leaf damage was ten times higher in burned forests, with implications for the future of burned forest regeneration in water-limited regions of the Amazon basin. In particular, the combination of higher mean temperatures, greater temperature variability, and more frequent exposure to damaging thermal thresholds implies that burned tropical forests will experience substantially higher mortality rates and slower biomass recovery compared to intact and selectively logged forests, especially in water-limited regions where trees cannot rely on evaporative cooling to moderate canopy temperatures.