Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Anodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Evaluation of chemical conversion material (protective coating) exposed to space environmental conditions

This report focuses on the development of an operational Rutherford backscattering spectrometry (RBS) system and shows the application of such a system on a space environmental test. Thin films of aluminum and tantalum were deposited on diamond substrates. These films were anodized and preexposure characterization spectra obtained using RBS and total hemispherical reflectance. The samples were exposed to energetic protons then postexposure characterization spectra was obtained using the same techniques. Conclusions based on the comparison of preexposure and postexposure spectra are presented. RBS comparison spectra show no change in the metal/metal oxide interface, while the comparison reflectance data indicate change. Explanations for this reflectance change are presented in this report.

Edwards, D. L.↗

New class of Si-based superlattices - Alternating layers of crystalline Si and porous amorphous Si(1-x)Ge(x) alloys

Superlattices consisting of alternating layers of crystalline Si and porous amorphous Si(1-x)Ge(x) have been fabricated. This is accomplished by first growing a Si/Si(0.7)Ge(0.3) superlattice by molecular beam epitaxy, followed by Ar-ion milling to form mesa structures, and finally by immersion in HF:HNO3:H2O. This solution creates a porous structure similar to that created by anodic etching, and a high selectivity is observed for the conversion of the alloy layers relative to the Si layers. The degree of selectivity is found to depend on alloy-layer thickness and strain. Superlattices have been fabricated from 1-micron wide mesas with Si(0.7)Ge(0.3) layers fully converted to 5-nm thick porous amorphous material.

Fathauer, R. W.↗

ORFEUS-SPAS - The Berkeley EUV spectrometer

The Berkeley EUV spectrometer of ORFEUS-SPAS, a joint project of NASA and the BMFT, incorporates a set of four novel spherically figured, varied line-space gratings used in a geometry that is similar to that of the classic Rowland mount to span an interval of 390 and 1200 A. Two spectral detector units containing curved microchannel plates and delay-line anodes encode the arriving photons in digital format for telemetry. An additional optic directs the image of the source in the entrance aperture onto a sealed FUV detector which is used to track the source as it drifts during an observation, enabling a postflight reconstruction of the spacecraft pointing vector. This in turn makes it possible to define with precision the wavelength of each recorded photon.

Bowyer, Stuart↗

Transient current interruption mechanism in a magnetically delayed vacuum switch

The capacity of a magnetically delayed vacuum switch to conduct current depends on the density of plasma injected into the switch. Exceeding the current capacity results in the switch entering a lossy mode of operation characterized by a transient interruption of the main current (opening behavior) and a rapid increase of voltage across the vacuum gap. Streak and framing photographs of the discharge indicate that a decrease of luminosity near the middle of the gap preceeds the transition to the opening phase. The zone of low luminosity propagates toward the cathode. This evidence suggests that the mechanism causing the opening phase is erosion of the background plasma in a manner similar to that in a plasma-opening switch. The resulting ion depletion forces a space-charge-limited conduction mode. The switch inductance maintains a high discharge current even during the space-charge-limited conduction phase, thus producing high internal fields. The high accelerating voltage, in turn, produces electron and ion beams that heat the electrode surfaces. As a result of the heating, jets of electrode vapor issue from the electrodes, either cathode or anode, depending on the selection of electrode materials.

Morris, Gibson, Jr.↗

Monolithic integrated circuit charge amplifier and comparator for MAMA readout

Prototype ICs for the Solar Heliospheric Observatory's Multi-Anode Microchannel Array (MAMA) have been developed; these ICs' charge-amplifier and comparator components were then tested with a view to pulse response and noise performance. All model performance predictions have been exceeded. Electrostatic discharge protection has been included on all IC connections; device operation over temperature has been consistent with model predictions.

Cole, Edward H.↗

High-dynamic-range MCP structures

We report on the development of a new high-dynamic-range two-stage Multi-Anode Microchannel Array (MAMA) imaging tube designed for improved high count rate performance at FUV and EUV wavelengths. The new two-stage MAMA tube employs two 25-mm-diameter format MCPs placed in tandem with a small gap between the plates. The front (input) MCP is designed to be a low-gain converter plate that supports an opaque photocathode and converts the detected photons to electrons, while the second (output) MCP is of higher conductivity and thus maintains the overall gain of the multiplier at high count rates. The second MCP is mounted in proximity focus with a (224 x 960)-pixel fine-fine coincidence MAMA array for high-spatial-resolution imaging studies. The applied voltage across each MCP can be controlled independently. We report on the gain and dynamic range performance characteristics of the two-stage MAMA tube in two different configurations: first, with the output MCP having moderate conductivity (about 100 MOhm); and second, with the output MCP having very high conductivity (about 2 MOhm). These results are compared and contrasted with those of the more conventional MAMA tube configuration which employs a single high-gain curved-channel MCP.

Slater, David C.↗

Performance characteristics of the imaging MAMA detector systems for SOHO, STIS, and FUSE/Lyman

Imaging Extreme Ultraviolet (EUV) Multi-Anode Microchannel Array (MAMA) detector systems with formats of 360 x 1024 pixels and pixel dimensions of 25 x 25 sq microns are being fabricated and tested for flight in two instruments on the ESA/NASA Solar and Heliospheric Observatory (SOHO). In addition, very-large-format (1024 x 1024)- and (2048 x 2048)-pixel Far Ultraviolet (FUV) and EUV MAMA detectors with pixel dimensions of 25 x 25 sq microns are being fabricated and tested for use in the NASA Goddard Space Flight Center's Hubble Space Telescope Imaging Spectrograph (STIS), a second-generation instrument scheduled for in-orbit installation in 1997. Finally, FUV MAMA detectors with formats of 224 x 960 pixels and pixel dimensions of 14 x 14 sq microns are being evaluated as prototypes of the detector for the prime FUV spectrograph of the Far Ultraviolet Spectroscopic Explorer (FUSE/Lyman) mission. The configurations and performance characteristics of the different detector systems are described, and the plans for further development of the Advanced Technology MAMA detector system discussed.

Timothy, J. G.↗

High resolution, two-dimensional imaging, microchannel plate detector for use on a sounding rocket experiment

We discuss a high resolution microchannel plate (MCP) imaging detector to be used in measurements of Doppler-shifted hydrogen Lyman-alpha line emission from Jupiter and the interplanetary medium. The detector is housed in a vacuum-tight stainless steel cylinder (to provide shielding from magnetic fields) with a MgF2 window. Operating at nominal voltage, the four plate configuration provides a gain of 1.2 x 10 exp 7 electrons per incident photon. The wedge-and-strip anode has two-dimensional imaging capabilities, with a resolution of 40 microns FWHM over a one centimeter diameter area. The detector has a high quantum efficiency while retaining a low background rate. A KBr photocathode is used to enhance the quantum efficiency of the bare MCPs to a value of 35 percent at Lyman-alpha.

Bush, Brett C.↗

Preliminary results from the MAMA detectors for the SOHO mission

Multi-Anode Microchannel Array (MAMA) detector systems are being fabricated and tested for use in the Solar Ultraviolet Measurements of Emitted Radiation (SUMER) and the Ultraviolet Coronagraph Spectrometer (UVCS) instruments on the ESA/NASA Solar and Heliospheric Observatory (SOHO) mission. The SOHO MAMA detector systems have formats of 360 x 1024 pixels and pixel dimensions of 25 x 25 sq microns and are optimized for operation at Extreme Ultraviolet (EUV) wavelengths between 40 and 160 nm. In this paper we report on the initial results of measurements of the performance characteristics of the first flight-configuration detector system employing the new custom Application Specific Integrated Circuits (ASICs) which are designed to improve both the dynamic range and the uniformity of response. The performance characteristics of this detector system are compared with those of earlier breadboard systems employing discrete-component electronics circuits.

Slater, David C.↗

Fabrication of luminescent porous silicon with stain etches and evidence that luminescence originates in amorphous layers

Simple immersion of Si in stain etches of HF:HNO3:H2O or NaNO2 in aqueous HF was used to produce films exhibiting luminescence in the visible similar to that of anodically-etched porous Si. All of the luminescent samples consist of amorphous porous Si in at least the near surface region. No evidence was found for small crystalline regions within these amorphous layers.

Fathauer, R. W.↗

Improved Li/TiS2 cell cycling in ether-based electrolytes with synergistic additives

Based on an extensive series of normalized full cell Li/TiS2 cycling studies, open-circuit storage tests, microcalorimetry and AC impedance studies, and chemical precedent, we propose an integrated chemical model consistent with experimental observations concerning the behavior of numerous LiAsF6/cyclic ether electrolytes. The particularly striking potency of certain additives such as 2-methylfuran and the hydroxide action resides in their ability to intercept several different adverse catalytic processes concurrently in the bulk electrolyte as well as the Li anode and TiS2 cathode.

Dominey, L. A.↗

A 250 GHz planar low noise Schottky receiver

A planar quasi-optical Schottky receiver based on the quasi-integrated horn antenna has been developed and tested over the 230-280 GHz bandwidth. The receiver consists of a planar GaAs Schottky diode placed at the feed of a dipole-probe suspended on a thin dielectric membrane in an etched-pyramidal horn cavity. The diode has a 1.21 micron anode diameter and a low parasitic capacitance due to the use of an etched surface channel. The antenna-mixer results in a measured DSB conversion loss and noise temperature at 258 GHz of 7.2 dB +/- 0.5 dB and 1310 K +/- 70 K, respectively, at room temperature. The design is compatible with SIS mixers, and the low cost of fabrication and simplicity makes it ideal for submillimeter-wave imaging arrays requiring a 10-20 percent bandwidth.

Ali-Ahmad, Walid Y.↗

Intensity distribution of the X-ray source for the AXAF VETA-I mirror test

Intensity distribution measurements of the X-ray source for the AXAF VETA-I mirror test are reported. During the VETA-I test, microscope pictures were taken for each used anode immediately after it was brought out of the source chamber. The source sizes and the intensity distribution structures are shown. They are compared and shown to agree with the results from pinhole camera measurements. It is demonstrated that under operating conditions characteristic of the VETA-I test, all the source sizes have an FWHM of less than 0.45 mm. For a source of this size at 528 m away, the angular size to VETA is less than 0.17 arcsec, which is small compared to the on-ground VETA angular resolution. These results were crucial for VETA data analysis and for obtaining the on-ground and predicted in-orbit VETA point response function.

Zhao, Ping↗

Correcting X-ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters, correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗

Steady state composition with low Fe(2+) concentrations for efficient O2 production by 'magma' electrolysis of lunar soils

Parameters are estimated for a hypothetical, well stirred, continuous-feed electrolytic cell that converts 20 percent of a lunar soil feedstock to O2 gas, 26 percent to Fe-Si metal, 13 percent to spinel, and 41 percent to slag. Advantages of a molten Fe-Si cathode for trapping metal on reduction, a relatively conductive steady-state composition in equilibrium with spinel (a proposed container material), and close electrodes (less than 1 cm cathode-anode distance) are discussed. To produce 1 ton of O2, about 6 MHW of energy are required for the electrolysis and IR heating within the melt, and another about 6 MHW may be introduced as waste heat through internal resistance of the electrodes. Thus, to produce 1 ton of O2 per 24 hours, about 0.5 MW of power delivered to the cell would be required.

Haskin, Larry A.↗

Electrochemical impedance spectroscopy of lithium-titanium disulfide rechargeable cells

The two-terminal alternating current impedance of Li/TiS2 rechargeable cells was studied as a function of frequency, state-of-charge, and extended cycling. Analysis based on a plausible equivalent circuit model for the Li/TiS2 cell leads to evaluation of kinetic parameters for the various physicochemical processes occurring at the electrode/electrolyte interfaces. To investigate the causes of cell degradation during extended cycling, the parameters evaluated for cells cycled 5 times were compared with the parameters of cells cycled over 600 times. The findings are that the combined ohmic resistance of the electrolyte and electrodes suffers a tenfold increase after extended cycling, while the charge-transfer resistance and diffusional impedance at the TiS2/electrolyte interface are not significantIy affected. The results reflect the morphological change and increase in area of the anode due to cycling. The study also shows that overdischarge of a cathode-limited cell causes a decrease in the diffusion coefficient of the lithium ion in the cathode.

Narayanan, S. R.↗

Extraction of oxygen from the Mars atmosphere using glow-discharge and permeation techniques

Oxygen can be extracted from carbon dioxide via thermal dissociation at elevated temperatures. However, temperatures in excess of 1000 K are needed to effect significant levels of dissociation. The experiments reported here have examined the feasibility of using a glow-discharge in low-pressure carbon dioxide to produce increased atomic oxygen yields at lower temperatures (on the order of 800 K). The experiments have shown that when silver membranes are used simultaneously as anodes for the glow discharge and as permeable membranes for oxygen separation, oxygen yields which are comparable to the permeation rates for pure oxygen, can be produced. Since the silver membrane can be employed as the electrode interface between Mars atmosphere and a stabilized-zirconia electrochemical pump, glow-discharge enhancement can be considered as a complementary technology which can be used with the zirconia-based oxygen extraction systems described previously by others. Not only can glow-discharge be used to increase oxygen yields at lowered temperatures, but it can also be considered as a possible way to avoid filtration and compression of Mars atmosphere, since the glow-discharge can be sustained in Mars ambient pressures.

Wu, Dongchuan↗

Free-Flow Open-Chamber Electrophoresis

Free-flow open-chamber electrophoresis variant of free-flow electrophoresis performed in chamber with open ends and in which velocity of electro-osmotic flow adjusted equal to and opposite mean electrophoretic velocity of sample. Particles having electrophoretic mobilities greater than mean mobility of sample particles move toward cathode, those with mobilities less move toward anode. Technique applied to separation of components of mixtures of biologically important substances. Sensitivity enhanced by use of tapered chamber.

Sharnez, Rizwan↗