Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Fluorescence Correlation Spectroscopy with Photobleaching Correction in Slowly Diffusing Systems

Fluorescence correlation spectroscopy (FCS) is a powerful tool to quantitatively study the diffusion of fluorescently labeled molecules. It allows in principle important questions of macromolecular transport and supramolecular aggregation in living cells to be addressed. However, the crowded environment inside the cells slows diffusion and limits the reservoir of labeled molecules, causing artifacts that arise especially from photobleaching and limit the utility of FCS in these applications. We present a method to compute the time correlation function from weighted photon arrival times, which compensates computationally during the data analysis for the effect of photobleaching. We demonstrate the performance of this method using numerical simulations and experimental data from model solutions. Using this technique, we obtain correlation functions in which the effect of photobleaching has been removed and in turn recover quantitatively accurate mean-square displacements of the fluorophores, especially when deviations from an ideal Gaussian excitation volume are accounted for by using a reference calibration correlation function. This allows quantitative FCS studies of transport processes in challenging environments with substantial photobleaching like in living cells in the future.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-Ray Digital Radiography to Study Gold–Silver Nose Decorations from the Moche Tomb of the Lady of Cao

In the present study nose decorations from the tomb of the ‘Lady of Cao’, a mummified Moche woman dated around third–fourth century AD, were analyzed by a portable X-ray digital radiography (XDR) system. The Moche civilization flourished along the north coast of present-day Peru, between the Andes and the Pacific Ocean, approximately between 100 and 600 AD. The Moche were very sophisticated artisans and metal smiths, so that they are considered the finest producers of jewels and artifacts of the region. Their metalworking ability was impressively demonstrated by the excavations of the tomb of the ‘Lady of Cao’, discovered by Regulo Franco in 2005. More than 100 beautiful jewels were found in this tomb, among them about 40 nose decorations composed of a combination of gold and silver sheets. Radiographs of several of them were carried out, with the aim to evaluate the gold–silver joining process, to check the homogeneity of the alloy and to quantify the thickness of the sheets. The XDR system consisted of a mini X-ray tube and of a digital X-ray flat panel. The radiographic images of the nose decorations revealed details of the manufacturing process and of the Au–Ag junction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evidence of Superconductivity in Electrical Resistance Measurements of Hydrides Under High Pressure

In the standard van der Pauw four-probe configuration commonly used for electrical resistance measurements, including those of hydrogen-rich samples at high pressures, the application of electrical current through one pair of leads while measuring voltage difference across another pair is a fundamental practice (see the inset in Fig. 1c). In the scenario described in Ref. [5], where electrical resistance vanishes due to disconnection between current and voltage probes or due to an onset of giant magnetoresistance in parts of the sample, it is crucial to consider the implications across different probe orientations: while one orientation may indeed result in vanishing electrical resistance, a divergence of the electrical resistance towards infinity will be observed in an alternative orientation where the applied current pattern is rotated a quarter turn (see the scheme on the inset in Fig. 1c). It is imperative to acknowledge that experimental data encompassing all possible probe orientations are essential for eliminating artifacts and assessing sample homogeneity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of nuclear materials by energy dispersive x-ray fluorescence and spectral effects of alpha decay

Energy dispersive X-ray fluorescence (EDXRF) spectra collected from alpha emitters are complicated by artifacts inherent to the alpha decay process, particularly when using portable instruments. For example, {sup 239}Pu EDXRF spectra exhibit a prominent uranium L X-ray emission peak series due to sample alpha decay rather than source-induced X-ray fluorescence. A portable EDXRF instrument was used to collect spectra from plutonium, americium, and a Pu-contaminated steel sample. The plutonium sample was also analyzed by wavelength dispersive XRF to demonstrate spectral differences observed when using these very different instruments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Image fusion for neutron tomography of nuclear fuel

Image fusion, the process of combining different images together, can be useful to create a more complete picture. In this work, image fusion is applied to neutron tomography of nuclear fuel with the goal of enhancing the information obtained about the fuel. Different reconstruction methods, such as Feldkamp, Davis and Kress filtered back projection and Simultaneous Reconstruction Technique, were combined to enhance image quality. This methodology was shown to reduce noise and ring artifacts without sacrificing sharp edges, allowing for a more accurate representation of sample geometry. Technique enhancements and future applications for the neutron imaging community are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine learning models for segmentation and classification of cyanobacterial cells

Abstract Timelapse microscopy has recently been employed to study the metabolism and physiology of cyanobacteria at the single-cell level. However, the identification of individual cells in brightfield images remains a significant challenge. Traditional intensity-based segmentation algorithms perform poorly when identifying individual cells in dense colonies due to a lack of contrast between neighboring cells. Here, we describe a newly developed software package called Cypose which uses machine learning (ML) models to solve two specific tasks: segmentation of individual cyanobacterial cells, and classification of cellular phenotypes. The segmentation models are based on the Cellpose framework, while classification is performed using a convolutional neural network named Cyclass. To our knowledge, these are the first developed ML-based models for cyanobacteria segmentation and classification. When compared to other methods, our segmentation models showed improved performance and were able to segment cells with varied morphological phenotypes, as well as differentiate between live and lysed cells. We also found that our models were robust to imaging artifacts, such as dust and cell debris. Additionally, the classification model was able to identify different cellular phenotypes using only images as input. Together, these models improve cell segmentation accuracy and enable high-throughput analysis of dense cyanobacterial colonies and filamentous cyanobacteria.

Huffine, Clair A.↗

A statistical analysis of the effects of urease pre-treatment on the measurement of the urinary metabolome by gas chromatography–mass spectrometry

Urease pre-treatment of urine has been utilized since the early 1960s to remove high levels of urea from samples prior to further processing and analysis by gas chromatography-mass spectrometry (GC-MS). Aside from the obvious depletion or elimination of urea, the effect, if any, of urease pre-treatment on the urinary metabolome has not been studied in detail. Here, we report the results of three separate but related experiments that were designed to assess possible indirect effects of urease pre-treatment on the urinary metabolome as measured by GC-MS. In total, 235 GC-MS analyses were performed and over 106 identified and 200 unidentified metabolites were quantified across the three experiments. The results showed that data from urease pre-treated samples 1) had the same or lower coefficients of variance among reproducibly detected metabolites, 2) more accurately reflected quantitative differences and the expected ratios among different urine volumes, and 3) increased the number of metabolite identifications. Altogether, we observed no negative consequences of urease pre-treatment. In contrast, urease pretreatment enhanced the ability to distinguish between volume-based and biological sample types compared to no treatment. Taken together, these results show that urease pretreatment of urine offers multiple beneficial effects that outweigh any artifacts that may be introduced to the data in urinary metabolomics analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge

Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.

47 OTHER INSTRUMENTATION↗

Archaeological Arsenical Bronzes and Equilibrium in the As-Cu System

Understanding the effects of impurities, segregation, undercooling, and solidification velocity is necessary to reconstruct prehistoric As-Cu alloy manufacturing processes and practices. Moreover, these alloys often contain a wide variety of minor and trace elements such that the binary As-Cu equilibrium phase diagram does not adequately represent arsenical bronze artifacts as-cast in ancient molds. Furthermore, the variable cooling rates present in as-cast alloys of predominantly arsenic and copper, due to the thermal properties of differing mold materials, would have had profound effects on the formation of inversely segregated arsenic. Alloys with 1 to 15 wt pct arsenic were prepared and studied using differential thermal analysis, metallography, and scanning electron microscopy with energy-dispersive X-ray spectroscopy. Equilibrium diagrams were established and the potential influence of trace elements discussed. A new liquidus curve for the equilibrium diagram in this compositional range, measuring slightly higher in temperature, was established.

36 MATERIALS SCIENCE↗

Validation of early image acquisitions following Tc-99 m sestamibi injection using a semiconductors camera of cadmium-zinc-telluride

Background: Cadmium-zinc-telluride (CZT) cameras allow to decrease significantly the acquisition time of myocardial perfusion imaging (MPI), but the duration of the examination is still long. Therefore, this study was performed to test the feasibility of early imaging following injection of Tc-99 m sestamibi using a CZT camera. Methods: Seventy patients underwent both an early and a delayed image acquisition after exercise stress test (n = 30), dipyridamole stress test (n = 20), and at rest (n = 20). After injection of Tc-99 m sestamibi, the early image acquisition started on average within 5 minutes for the exercise and rest groups, and 3 minutes 30 seconds for the dipyridamole group. Two independent observers evaluated image quality and extracardiac uptake on four-point scales. The difference between early and later images for each patient was scored on a five-point scale. Results: The image quality and extracardiac uptake of early and delayed image acquisitions were not different for the three groups (P > .05). There was no significant difference between early and delayed image acquisitions in the exercise, dipyridamole, and rest groups, respectively, in 63%, 40%, and 80% of cases. In the exercise group and rest group, a defect was only present in early MPI, respectively, in 13% and 20% of cases. A defect was only present in delayed images in 10% of cases in the exercise group and in 45% of cases in the dipyridamole group. Conclusions: There was no difference between early and later image acquisitions in terms of quality. This protocol reduces the length of the procedure for the patient. Beginning with early image acquisitions may help to overcome the artifacts that are observed at the delayed time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The high matrix acquisition technique for imaging of atherosclerotic plaque inflammation in fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography with time-of-flight: Phantom study

Background: Motion artifact and partial volume effect caused underestimation of coronary plaque inflammation. This study evaluated the high matrix acquisition technique using time-of-flight (TOF) positron emission tomography/computed tomography for imaging of atherosclerotic plaque inflammation with fluorine-18 fluorodeoxyglucose in small and moving phantoms. Methods and Results: All images were reconstructed using a conventional algorithm without TOF (4 × 4 × 4 mm{sup 3} voxel size) and a high matrix algorithm with TOF (2 × 2 × 2 mm{sup 3} voxel size). Microsphere phantoms of 10, 7.9, 6.2, 5.0, and 4.0 mm diameters were acquired in 3-dimensional list-mode for 30 minutes. A heart phantom mimicking cardiac motion consisted of a hot spot simulating a plaque (φ 4 mm, φ 2 mm) on the outside of the left ventricle. In the microsphere and heart phantom study, visual discrimination, maximum activity, and target-to-background ratio using the high matrix algorithm with TOF were better than those using the conventional algorithm without TOF. Conclusion: The high matrix algorithm with TOF improves detection of small targets in phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical performance of Rb-82 myocardial perfusion PET and Tc-99m-based SPECT in patients with extreme obesity

Background: We evaluated the performance of stress imaging with technetium-99m-labeled tetrofosmin single-photon emission computed tomography (SPECT) and rubidium-82 positron emission tomography (PET) in patients with extreme obesity, defined as body mass index ≥40 kg/m{sup 2}. Methods: We identified patients with extreme obesity who underwent angiography in our center and either stress SPECT or PET within the previous six months. Cohorts of patients with extreme obesity and a <5% pretest likelihood of CAD who underwent SPECT (N = 25) or PET (N = 25) were also included. Results: In total, 108 patients who underwent SPECT (N = 57) or PET (N = 51) were identified. Scan interpretation was classified as definitely normal or abnormal in 83.3% of PET and 60.5% of SPECT scans, respectively (P < .01). PET demonstrated higher diagnostic accuracy and normalcy rate. PET was found to have higher specificity for the pooled cohort. Similar findings were observed using stenosis cut-offs of ≥50% and ≥70%. Conclusions: In patients with extreme obesity, PET enabled more definitive scan interpretation with less artifact compared to SPECT. PET provided higher diagnostic accuracy and specificity in the detection of obstructive coronary artery disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advances in imaging instrumentation for nuclear cardiology

Advances in imaging instrumentation and technology have greatly contributed to nuclear cardiology. Dedicated cardiac SPECT cameras incorporating novel, highly efficient detector, collimator, and system designs have emerged with the expansion of nuclear cardiology. Solid-state radiation detectors incorporating cadmium zinc telluride, which directly convert radiation to electrical signals and yield improved energy resolution and spatial resolution and enhanced count sensitivity geometries, are increasingly gaining favor as the detector of choice for application in dedicated cardiac SPECT systems. Additionally, hybrid imaging systems in which SPECT and PET are combined with X-ray CT are currently widely used, with PET/MRI hybrid systems having also been recently introduced. The improved quantitative SPECT/CT has the potential to measure the absolute quantification of myocardial blood flow and flow reserve. Rapid development of silicon photomultipliers leads to enhancement in PET image quality and count rates. In addition, the reduction of emission–transmission mismatch artifacts via application of accurate time-of-flight information, and cardiac motion de-blurring aided by anatomical images, are emerging techniques for further improvement of cardiac PET. This article reviews recent advances such as these in nuclear cardiology imaging instrumentation and technology, and the corresponding diagnostic benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prevalence and variability in reporting of clinically actionable incidental findings on attenuation-correction CT scans in a veteran population

Background: Myocardial perfusion imaging (MPI) often employs attenuation-correction computed tomography (CTAC) to reduce attenuation artifacts and improve specificity. While there is no specific guideline on how they should be reported, incidental noncardiac findings identified on these scans may be clinically significant. The prevalence of these findings in veterans is not currently known. In addition, variability in reporting these findings may depend on the interpreting physician’s specialty. Methods: To guide future decision-making, CTACs in veterans referred for MPI were prospectively evaluated in a quality-control project for a set of prespecified actionable incidental findings by cardiologists and a radiologist. Results: On the 771 scans performed over eight months, 285 incidental noncardiac findings were identified by the interpreting cardiologists and 378 were identified by the interpreting radiologist. Pulmonary nodules were the most common occurring in 20% of studies read by the radiologist. Interreader agreements between cardiologists and the radiologist were poor for pulmonary nodules ≥ 10 mm and hiatal hernias; fair for pulmonary nodules < 10 mm, extracardiac masses, and aortic aneurysms; and moderate for pleural plaques. Conclusion: Incidental noncardiac findings on CTACs are common in our veteran population. Overall interobserver agreement in identifying these findings between cardiologists and radiologists is fair. Specific guidelines are needed on how CTACs should be read and reported.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Location-Specific Microstructure Characterization Within AM Bench 2022 Nickel Alloy 718 3D Builds

Abstract The Additive Manufacturing Benchmark Test Series (AM Bench) is a broad effort to produce rigorous measurement datasets for validating AM computer simulations across the range of processing, structure, and properties, for many additive manufacturing (AM) build methods and material classes. Here, the microstructures of nickel alloy 718 AM Bench 2022 test artifacts produced using laser-based powder bed fusion (PBF-LB), in both as-built and fully heat-treated conditions, are examined. Cross sections are primarily characterized using large area scanning electron microscopy (SEM) electron backscatter diffraction (EBSD) and example analyses of the crystallographic textures are described. These data are part of a large set of in situ and ex situ measurements from both three-dimensional builds and laser tracks on bare plates. All the measurement data are available online with download links at www.nist.gov/ambench .

Levine, L. E. (ORCID:0000000334484229)↗

Effect of artificial viscosity on shocked particle-laden flows for staggered grid Lagrangian methods

Abstract Shocked particle-laden flows are important to many natural and industrial processes. When simulating these systems, artificial viscosity is often required to prevent numerical artifacts, such as ringing, from arising in the pressure and density fields. The linear and quadratic coefficients of the artificial viscosity determine the amount of smoothing that occurs in these fields. For particle-laden flows, however, many of the fluid–particle interaction forces, for example, the pressure gradient force and unsteady forces, depend on gradients in the fluid fields. Furthermore, while the shock passes over a particle, these forces can be more dominant than drag. This means that the artificial viscosity coefficients affect how a particle and fluid interact when simulating shocked particle systems. Here this effect is investigated for isolated particles and for a particle curtain using a staggered grid Lagrangian approach. The artificial viscosity coefficients have a significant impact on the maximum force that a fluid imparts to a particle, which is important for determining whether a particle will break up in response to the shock. Furthermore, it is found that the density ratio between the particle and the fluid is important in determining whether the artificial viscosity coefficients have a significant impact on the particle’s motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shock wave perturbation decay in granular materials

A technique in which the evolution of a perturbation in a shock wave front is monitored as it travels through a sample is applied to granular materials. Although the approach was originally conceived as a way to measure the viscosity of the sample, here it is utilized as a means to probe the deviatoric strength of the material. Initial results for a tungsten carbide powder are presented that demonstrate the approach is viable. Simulations of the experiments using continuum and mesoscale modeling approaches are used to better understand the experiments. The best agreement with the limited experimental data is obtained for the mesoscale model, which has previously been shown to give good agreement with planar impact results. The continuum simulations indicate that the decay of the perturbation is controlled by material strength but is insensitive to the compaction response. Other sensitivities are assessed using the two modeling approaches. The simulations indicate that the configuration used in the preliminary experiments suffers from certain artifacts and should be modified to remove them. As a result, the limitations of the current instrumentation are discussed, and possible approaches to improve it are suggested.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A New Workflow of X-ray CT Image Processing and Data Analysis of Structural Features in Rock Using Open-Source Software

X-ray computed tomography (CT) images of rock specimens often contain artifacts which must be corrected before scientific analyses are performed. Here, we present a new workflow of automated image processing to utilize poor-quality X-ray CT scan images. The workflow runs on the open-source image analysis software and efficiently separates desired features from low-contrast scanned images. The new workflow is a two-step technique using contrast enhancement and automated feature segmentation to generate noise-free binary images. The results of binary images using the proposed workflow and using a conventional thresholding technique are analyzed to show the quality of the proposed method. The paper also presents a workflow of estimating the structural geometries of features in two and three dimensions. The results of the structural feature analyses and computational time were compared between the open-source (ImageJ) and commercial image analysis software (Bruker Computed Tomography Analyzer). The commercial software was more computationally efficient, but the task-specific macros in open-source software enabled the user-desired automation in image processing and data extraction of desired structural features of comparable quality.

47 OTHER INSTRUMENTATION↗