Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

SU-C-210-06: Quantitative Evaluation of Dosimetric Effects Resulting From Positional Variations of Pancreatic Tumor Volumes

Purpose: The aim of this study is to quantify dosimetric effects resulting from variation in pancreatic tumor position assessed by bony anatomy and implanted fiducial markers Methods: Twelve pancreatic cancer patients were retrospectively analyzed for this study. All patients received modulated arc therapy (VMAT) treatment using fiducial-based Image Guided Radiation Therapy (IGRT) to the intact pancreas. Using daily orthogonal kV and/or Cone beam CT images, the shift needed to co-register the daily pre-treatment images to reference CT from fiducial to bone (Fid-Bone) were recorded as Left-Right (LR), Anterior-Posterior (AP) and Superior-Inferior (SI). The original VMAT plan iso-center was shifted based on KV bone matching positions at 5 evenly spaced fractions. Dose coverage of the planning target volumes (PTVs) (V100%), mean dose to liver, kidney and stomach/duodenum were assessed in the modified plans. Results: A total of 306 fractions were analyzed. The absolute fiducial-bone positional shifts were greatest in the SI direction, (AP = 2.7 ± 3.0, LR = 2.8 ± 2.8, and SI 6.3 ± 7.9 mm, mean ± SD). The V100% was significantly reduced by 13.5%, (Fid-Bone = 95.3 ± 2.0 vs. 82.3 ± 11.8%, p=0.02). This varied widely among patients (Fid-Bone V100% Range = 2–60%), where 33% of patients had a reduction in V100% of more than 10%. The impact on OARs was greatest to the liver (Fid-Bone= 14.6 vs. 16.1 Gy, 10%), and stomach, (Fid-Bone = 23.9 vx. 25.5 Gy, 7%), however was not statistically significant (p=0.10 both). Conclusion: Compared to matching by fiducial markers, matching by bony anatomy would have substantially reduced the PTV coverage by 13.5%. This reinforces the importance of online position verification based on fiducial markers. Hence, implantation of fiducial markers is strongly recommended for pancreatic cancer patients undergoing intensity modulated radiation therapy treatments.

60 APPLIED LIFE SCIENCES↗

SU-E-I-28: Introduction and Investigation of Effective Diameter Ratios as a New Patient Size Metric for Use in CT

Purpose: To introduce and investigate effective diameter ratios as a new patient metric for use in computed tomography protocol selection as a supplement to patient-specific size parameter data. Methods: The metrics of outer effective diameter and inner effective diameter were measured for 7 post-mortem subjects scanned with a standardized chest/abdomen/pelvis (CAP) protocol on a 320-slice MDCT scanner. The outer effective diameter was calculated by obtaining the anterior/posterior and lateral dimensions of the imaged anatomy at the middle of the scan range using Effective Diameter= SQRT(AP height*Lat Width). The inner effective diameter was calculated with the same equation using the AP and Lat dimensions of the anatomy excluding the adipose tissue. The ratio of outer to inner effective diameter was calculated for each subject. A relationship to BMI, weight, and CTDI conversion coefficients was investigated. Results: For the largest subject with BMI of 43.85 kg/m2 and weight of 255 lbs the diameter ratio was calculated as 1.33. For the second largest subject with BMI of 33.5 kg/m2 and weight of 192.4 lbs the diameter ratio was measured as 1.43, indicating a larger percentage of adipose tissue in the second largest subject’s anatomical composition. For the smallest subject at BMI of 17.4 kg/m2 and weight of 86 lbs a similar tissue composition was indicated as a subject with BMI of 24.2 kg/m2 and weight of 136 lbs as they had the same diameter ratios of 1.11. Conclusion: The diameter ratio proves to contain information about anatomical composition that the BMI and weight alone do not. The utility of this metric is still being examined but could prove useful for determining MDCT techniques and for giving a more in depth detail of the composition of a patient’s body habitus.

60 APPLIED LIFE SCIENCES↗

SU-E-J-33: Comparison Between Soft Tissue Alignment and Bony Alignment for Pancreatic Cancer Radiotherapy

Purpose An IGRT modality for pancreatic cancer treatment with dose escalation at our institution is in-room daily CT imaging. The purpose of this study is to assess the difference between soft tissue alignment and bony alignment for pancreatic tumor localization. Methods Eighteen patients with pancreatic tumors who underwent IMRT treatment with an inspiration breath-hold technique between July 2012 and February 2015 are included in this study. Prior to each treatment, a CT scan was acquired. The CT image guidance started with auto-alignment to either the bony anatomy (vertebral bodies) or fiducials (for the six patients with the stent in/near the tumor) and then, when necessary, manual adjustments were made based on soft tissue alignment using clinical software (CT-Assisted Targeting system). The difference between soft tissue alignment and bony/fiducial alignment was evaluated. Results Of all 380 treatments, manual adjustment was made in 225 treatments, ranging from 11% (3 treatments out of 28) to 96% (27 treatments out of 28) per patient. The mean of the difference between soft tissue alignment and bony/fiducial alignment per patient ranged from −3.6 to 0.3 mm, −1.5 to 2.8 mm, and −3.3 to 3.4 mm in the AP, SI, and RL directions, respectively. The maximum difference over all treatments was −9.5, −14.6, and −14.6 mm in the AP, SI, and RL directions, respectively. Conclusion About 60% of the time, manual adjustment based on soft tissue alignment was required. The extent of manual adjustment was usually small but varied significantly from patient to patient. The ultimate goal of the IGRT modality using daily CT imaging is not to fully cover the target but to spare organs-at-risk as much as possible to avoid them moving into higher dose gradients than accepted in the treatment plan. To this end, manual adjustment based on soft tissue alignment is critically important.

60 APPLIED LIFE SCIENCES↗

SU-E-T-191: Commissioning and Dosimetric Characteristics of Elekta Agility for Total Skin Electron Beam (TSEB) Therapy

Purpose The purpose of this work is to publish beam data from Elekta Synergy(R) linear accelerators with Agility(TM) MLC for total skin electron beam (TSEB) therapy using the HDRE1 (High Dose Rate Electron 6MeV) energy. Method & Materials The optimal gantry angles for TSEB were determined using ion chamber measurements along a vertical profile at 450cm SSD. After gantry angles were chosen, field uniformity was measured over the entire treatment area. Uniformity was measured with and without the patient support device, allowing the dosimetric effect of the support device to be determined. Beam output and PDD were measured at the calibration point (450cm SSD) for a dual beam using a parallel plate chamber in solid water. These measurements were repeated with the chamber and phantom rotated about the patient isocenter at various angles, in order to measure the contribution from oblique beams. This technique provides a precise measurement of the treatment skin dose (TSD). Lastly, ion chamber measurements were verified by film and diodes. Results The optimal gantry angle for 450 cm SSD was determined to be 90±16°. This achieved uniformity better than 96% on the vertical axis, and 92% along the horizontal axis. HDRE1 was calibrated to deliver 10 cGy/MU at standard geometry (100 cm SSD, 1.2 cm depth). Thus at TSEB geometry (450 cm SSD, 0.1 cm depth) the output of the AP dual field was measured to be 0.35 cGy/MU. The TSD of a 20 cm radius cylinder for six (equally, 60° spaced) dual fields was measured to be 1.19 cGy/MU. Percent Depth Dose data for the AP dual field and TSD are shown in Figure 2. Conclusion This paper provides a modern procedure for commissioning TSEB therapy on a linear accelerator, and clinical beam data for the Elekta Synergy(R) with Agility(TM) MLC.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-I-03: Preliminary Study of Size-Specific Dose Estimates in Adult Abdomenal CT Examinations in Taiwan

Purpose: This study was to investigate size-specific dose estimates (SSDE) for routine adult abdominal CT examinations in Taiwan. Methods: A national survey was conducted in Taiwan in 2014 to investigate SSDEs for routine adult abdominal CT examinations. The hospitals involved in this study provided CT images of their typical patients. The CT image in the level of the middle liver was selected to record the corresponding tube current, slice mAs or effective mAs. The image was also used to estimate the dimensions of patient as measuring the lengths in the anterior to posterior (AP) and lateral (LAT) directions. The effective diameter was then calculated from AP and LAT, and used to look up conversion factors in the AAPM 204 report. The volume CTDI (CTDIvol) for each CT unit was measured on sites using a 32-cm cylindrical standard dose phantom and a calibrated pencil-type ionization chamber. Individual patient’s SSDEs were then calculated from the corresponding SSDE conversion factor and the CTDIvol. Results: The study cohort included 111 CT units. The ratio of turning on automatic tube current modulation (ATCM) or not is 88:23. Effective diameters are 258.7±25.1 mm (167–366 mm). 99.3% of typical patients selected by each hospital have smaller effective diameter than the 32-cm dosimetry phantom. Adult abdomenal SSDE is 17.5 ± 8.8 mGy (1.9-58 mGy). The SSDE seems to decrease as the effective diameter increases as the ATCM turns off, and independent with the effective diameter as the ATCM turns on. Conclusion: The SSDE for typical patients in Taiwan was investigated. We continue to complete this investigation in 2015 to include more valid data to establish SSDE reference level in Taiwan. This study was financially supported by the Atomic Energy Council in Taiwan.

60 APPLIED LIFE SCIENCES↗

Realistic respiratory motion margins for external beam partial breast irradiation

Purpose: Respiratory margins for partial breast irradiation (PBI) have been largely based on geometric observations, which may overestimate the margin required for dosimetric coverage. In this study, dosimetric population-based respiratory margins and margin formulas for external beam partial breast irradiation are determined. Methods: Volunteer respiratory data and anterior–posterior (AP) dose profiles from clinical treatment plans of 28 3D conformal radiotherapy (3DCRT) PBI patient plans were used to determine population-based respiratory margins. The peak-to-peak amplitudes (A) of realistic respiratory motion data from healthy volunteers were scaled from A = 1 to 10 mm to create respiratory motion probability density functions. Dose profiles were convolved with the respiratory probability density functions to produce blurred dose profiles accounting for respiratory motion. The required margins were found by measuring the distance between the simulated treatment and original dose profiles at the 95% isodose level. Results: The symmetric dosimetric respiratory margins to cover 90%, 95%, and 100% of the simulated treatment population were 1.5, 2, and 4 mm, respectively. With patient set up at end exhale, the required margins were larger in the anterior direction than the posterior. For respiratory amplitudes less than 5 mm, the population-based margins can be expressed as a fraction of the extent of respiratory motion. The derived formulas in the anterior/posterior directions for 90%, 95%, and 100% simulated population coverage were 0.45A/0.25A, 0.50A/0.30A, and 0.70A/0.40A. The differences in formulas for different population coverage criteria demonstrate that respiratory trace shape and baseline drift characteristics affect individual respiratory margins even for the same average peak-to-peak amplitude. Conclusions: A methodology for determining population-based respiratory margins using real respiratory motion patterns and dose profiles in the AP direction was described. It was found that the currently used respiratory margin of 5 mm in partial breast irradiation may be overly conservative for many 3DCRT PBI patients. Amplitude alone was found to be insufficient to determine patient-specific margins: individual respiratory trace shape and baseline drift both contributed to the dosimetric target coverage. With respiratory coaching, individualized respiratory margins smaller than the full extent of motion could reduce planning target volumes while ensuring adequate coverage under respiratory motion.

60 APPLIED LIFE SCIENCES↗

SU-F-I-47: Optimizing Protocols for Image Quality and Dose in Abdominal CT of Large Patients

Purpose: Newer CT scanners are able to use scout views to adjust mA throughout the scan in order to achieve a given noise level. However, given constraints of radiologist preferences for kVp and rotation time, it may not be possible to achieve an acceptable noise level for large patients. A study was initiated to determine for which patients kVp and/or rotation time should be changed in order to achieve acceptable image quality. Methods: Patient scans were reviewed on two new Emergency Department scanners (Philips iCT) to identify patients over a large range of sizes. These iCTs were set with a limit of 500 mA to safeguard against a failure that might cause a CT scan to be (incorrectly) obtained at too-high mA. Scout views of these scans were assessed for both AP and LAT patient width and AP and LAT standard deviation in an ROI over the liver. Effective diameter and product of the scout standard deviations over the liver were both studied as possible metrics for identifying patients who would need kVp and/or rotation time changed. The mA used for the liver in the CT was compared to these metrics for those patients whose CT scans showed acceptable image quality. Results: Both effective diameter and product of the scout standard deviations over the liver result in similar predictions for which patients will require the kVp and/or rotation time to be changed to achieve an optimal combination of image quality and dose. Conclusion: Two mechanisms for CT technologists to determine based on scout characteristics what kVp, mA limit, and rotation time to use when DoseRight with our physicians’ preferred kVp and rotation time will not yield adequate image quality are described.

60 APPLIED LIFE SCIENCES↗

SU-F-T-396: Impact of Shoulder Deformation for Head and Neck VMAT

Purpose: For head and neck VMAT (HN-VMAT), variations of position and deformation of patient’s shoulders is a concern to affect inaccuracy of dose distribution. It has been reported that the setup error of the shoulders was variable from 5 mm – 1 cm. The beams of the HN-VMAT pass through the shoulders. We assessed the impact of shoulder deformation to dose distribution for HN-VMAT. Methods: One HN-VMAT plan was generated using a patient’s CT. The patient’s CT was deformed using ImSimQA (Oncology Systems Limited, Shrewsbury, Shropshire, UK) to generate several patterns of the shoulders’ deformations when the right and left humeral heads were shifted with 3, 6, and 15 mm in the superior and inferior directions (SI), 3, 5, and 15 mm in the anterior and posterior directions (AP), and 5 and 15 mm in the right or left direction (LR). DVH comparison was performed in the different deformation patterns. The dosimetric parameters of D95% for CTV70Gy, CTV60Gy and CTV54Gy and dmax for Spinal cord were also measured. Gamma index evaluation (Criteria: 3%/2mm) was performed to exhibit clinically tolerable area in the comparison. Results: DVH comparison shows similar for all structures. As the comparison for the dosimetric parameters, the variations of D95% in the LR and AP were within 1%. There were larger variations in the SI than those in the other directions, however were within 1.5%. In gamma index evaluation, the small spots with higher gamma index values were appeared when the shift was 6 mm, however the pass ratio was 99.13%. Conclusion: HN-VMAT should be robust for shoulder deformation and geometric accuracy within 6 mm from patient’s setup and image-guided radiotherapy may be clinically acceptable for target dose coverage or normal tissue dose sparing.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-02: A New Intra-Fractional Prostate Motion Tracking Method in Volumetric Modulated Arc Therapy (VMAT) Via 2D/3D Registration

Purpose: Intra-fractional prostate motion leads uncertainty on delivered dose in radiotherapy and may cause significant dose deviation from the planned dose distribution. This is especially a concern in scenarios with a high dose per fraction and hence a long delivery time, e.g. stereotactic body radiotherapy. Knowledge about intra-fractional prostate motion is valuable to address this problem, e.g. by reconstructing delivered dose and performing adaptation. This study proposes a new approach to determine intra-fractional prostate motion in VMAT via 2D/3D maker registration. Methods: At our institution, each patient has three markers implanted in the prostate. During treatment delivery, kV triggered images were taken every three seconds to acquire 2D projection of 3D anatomy at the direction orthogonal to the therapeutic beam. Projected marker locations were identified on each projection image using template matching with geometric constraints. 3D prostate translation and rotation for each triggered image were obtained by solving an optimization problem, such that the calculated marker locations match the measured ones. Inter-image motion smoothness was employed as a constraint. We tested this method in simulation studies with five realistic prostate motion trajectories acquired via Calypso and in real phantom experiments. Results: For the simulation case, the motion range for these patients was 0.5∼6.0 mm. Root mean square (RMS) error of calculated motion along left-right (LR), anterior-posterior (AP) and cranial-caudal (CC) directions were 0.26mm, 0.36mm, and 0.016mm, respectively. The motion range in the phantom study along LR, AP, and CC directions were 15mm, 20mm and 10mm. The mean RMS errors along these directions were 1.99mm, 1.37mm and 0.22mm. Conclusion: A new prostate motion tracking algorithm based on kV triggered images has been developed and validated. Clinically acceptable accuracy has been achieved.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-06: Evaluation of Interfractional and Intrafractional Tumor Motion in Stereotactic Liver Radiotherapy, Based On Four-Dimensional Cone-Beam Computed Tomography Using Fiducial Markers

Purpose: The purpose of this study was to evaluate the interfractional and intrafractional motion of liver tumors in stereotactic body radiation therapy (SBRT), based on four-dimensional cone-beam computed tomography using fiducial markers. (4D-CBCT). Methods: Seven patients with liver tumors were treated by SBRT with abdominal compression (AC) in five fractions with image guidance based on 4D-CBCT. The 4D-CBCT studies were performed to determine the individualized internal margin for the planning simulation. The interfractional and intrafractional changes of liver tumor motion for all patients was measured, based on the planning simulation 4D-CBCT, pre-SBRT 4D-CBCT, and post-SBRT 4D-CBCT. The interfractional motion change was calculated from the difference in liver tumor amplitude on pre-SBRT 4D-CBCT relative to that of the planning simulation 4D-CBCT for each fraction. The intrafractional motion change was calculated from the difference between the liver tumor amplitudes of the pre- and post-SBRT 4D-CBCT for each fraction. Significant interfractional and intrafractional changes in liver tumor motion were defined as a change ≥3 mm. Statistical analysis was performed using the Pearson correlation. Results: The values of the mean amplitude of liver tumor, as indicated by planning simulation 4D-CBCT, were 1.6 ± 0.8 mm, 1.6 ± 0.9 mm, and 4.9 ± 2.2 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively. Pearson correlation coefficients between the liver tumor amplitudes, based on planning simulation 4D-CBCT, and pre-SBRT 4D-CBCT during fraction treatment in the LR, AP, and SI directions were 0.6, 0.7, and 0.8, respectively. Interfractional and intrafractional motion changes of ≥3 mm occurred in 23% and 3% of treatment fractions, respectively. Conclusion: The interfractional and intrafractional changes of liver tumor motion were small in most patients who received liver SBRT with AC. In addition, planning simulation 4D-CBCT was useful for representing liver tumor movement in patients undergoing SBRT. This work was supported by JSPS KAKENHI Grant Number 26861004.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-14: Assessment of Inter- and Intra-Fractional Motion for Extremity Soft Tissue Sarcoma Patients by Using In-House Real-Time Optical Image-Based Monitoring System

Purpose: This study aimed to assess inter- and intra-fractional motion for extremity Soft Tissue Sarcoma (STS) patients, by using in-house real-time optical image-based monitoring system (ROIMS) with infra-red (IR) external markers. Methods: Inter- and intra-fractional motions for five extremity (1 upper, 4 lower) STS patients received postoperative 3D conformal radiotherapy (3D-CRT) were measured by registering the image acquired by ROIMS with the planning CT image (REG-ROIMS). To compare with the X-ray image-based monitoring, pre- and post-treatment cone beam computed tomography (CBCT) scans were performed once per week and registered with planning CT image as well (REG-CBCT). If the CBCT scan is not feasible due to the large couch shift, AP and LR on-board imager (OBI) images were acquired. The comparison was done by calculating mutual information (MI) of those registered images. Results: The standard deviation (SD) of the inter-fractional motion was 2.6 mm LR, 2.8 mm SI, and 2.0 mm AP, and the SD of the intra-fractional motion was 1.4 mm, 2.1 mm, and 1.3 mm in each axis, respectively. The SD of rotational inter-fractional motion was 0.6° pitch, 0.9° yaw, and 0.8° roll and the SD of rotational intra-fractional motion was 0.4° pitch, 0.9° yaw, and 0.7° roll. The derived averaged MI values were 0.83, 0.92 for REG-CBCT without rotation and REG-ROIMS with rotation, respectively. Conclusion: The in-house real-time optical image-based monitoring system was implemented clinically and confirmed the feasibility to assess inter- and intra-fractional motion for extremity STS patients while the daily basis and real-time CBCT scan is not feasible in clinic.

60 APPLIED LIFE SCIENCES↗

TU-FG-209-12: Treatment Site and View Recognition in X-Ray Images with Hierarchical Multiclass Recognition Models

Purpose: To investigate an approach of automatically recognizing anatomical sites and imaging views (the orientation of the image acquisition) in 2D X-ray images. Methods: A hierarchical (binary tree) multiclass recognition model was developed to recognize the treatment sites and views in x-ray images. From top to bottom of the tree, the treatment sites are grouped hierarchically from more general to more specific. Each node in the hierarchical model was designed to assign images to one of two categories of anatomical sites. The binary image classification function of each node in the hierarchical model is implemented by using a PCA transformation and a support vector machine (SVM) model. The optimal PCA transformation matrices and SVM models are obtained by learning from a set of sample images. Alternatives of the hierarchical model were developed to support three scenarios of site recognition that may happen in radiotherapy clinics, including two or one X-ray images with or without view information. The performance of the approach was tested with images of 120 patients from six treatment sites – brain, head-neck, breast, lung, abdomen and pelvis – with 20 patients per site and two views (AP and RT) per patient. Results: Given two images in known orthogonal views (AP and RT), the hierarchical model achieved a 99% average F1 score to recognize the six sites. Site specific view recognition models have 100 percent accuracy. The computation time to process a new patient case (preprocessing, site and view recognition) is 0.02 seconds. Conclusion: The proposed hierarchical model of site and view recognition is effective and computationally efficient. It could be useful to automatically and independently confirm the treatment sites and views in daily setup x-ray 2D images. It could also be applied to guide subsequent image processing tasks, e.g. site and view dependent contrast enhancement and image registration. The senior author received research grants from ViewRay Inc. and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Demonstrating Cross-Facility Data Processing at Scale with Laue Microdiffraction

In February and April 2023 live, at-scale data processing demonstrations were conducted between the Advanced Photon Source (APS), a synchrotron light source, and the Argonne Leadership Computing Facility (ALCF). These tests were run as part of a novel beamline technique: coded aperture laue micro-diffraction. This technique requires a significant amount of compute to decode appeture patterns embedded in the detector stream. An autonomous system was able to send data to ALCF during an experiment, utilize 50 nodes of the Polaris supercomputer to process 6-12 hour scans, and return the data back to the APS within 12-15 minutes behind the detector. With scan points arriving every 72 seconds, the system kept up with the beamline, potentially enabling in-experiment analysis. The data processing system utilizes Globus infrastructure and an on-demand queue to dynamically acquire nodes on Polaris. The underlying reconstruction algorithms were parallelized via MPI and accelerated with custom CUDA kernels.

Prince, Michael↗

High-Energy X-Ray Diffraction Analysis Tool

The functionality of heRXD includes the following: distance and angular calibration and viewing flat-panel detector images used for X-ray diffraction; image (polar) rebinning or "caking"; line position fitting in powder diffraction images; image segmentation or "blob finding"; crystal orentation indesing; and lattice vector refinement. These functionalities encompass a critical set analyzing teh data for high-energy diffraction measurements that are currently performed at synchrotron sources such as the Advanced Photon Source (APS). The software design modular and open source under LGPL. The intent is to provide a common framework and graphical user interface that has the ability to utillize internal as well as external subroutines to provide various optins for performing the fuctionalities listed above. The software will initially be deployed at several national user facilities--including APS, ALS, and CHESS--and then made available for download using a hosting service such as sourceforge.

Source record↗

Coral Life History and Symbiosis: functional genomic resources for two reef building Caribbean corals, Acropora palmata and Montastraea faveolata

Scleractinian corals are the foundation of reef ecosystems in tropical marine environments. Their great success is due to interactions with endosymbiotic dinoflagellates (Symbiodinium spp.), with which they are obligately symbiotic. To develop a foundation for studying coral biology and coral symbiosis, we have constructed a set of cDNA libraries and generated and annotated ESTs from two species of corals, Acropora palmata and Montastraea faveolata. Here we generated 14,588 (Ap) and 3,854 (Mf) high quality ESTs from five life history/symbiosis stages (spawned eggs, early-stage planula larvae, late-stage planula larvae either infected with symbionts or uninfected, and adult coral). The ESTs assembled into a set of primarily stage-specific clusters, producing 4,980 (Ap), and 1,732 (Mf) unigenes. The egg stage library, relative to the other developmental stages, was enriched in genes functioning in cell division and proliferation, transcription, signal transduction, and regulation of protein function. Fifteen unigenes were identified as candidate symbiosis-related genes as they were expressed in all libraries constructed from the symbiotic stages and were absent from all of the non symbiotic stages. These include several DNA interacting proteins, and one highly expressed unigene (containing 17 cDNAs) with no significant protein-coding region. A significant number of unigenes (25) encode potential pattern recognition receptors (lectins, scavenger receptors, and others), as well as genes that may function in signaling pathways involved in innate immune responses (toll-like signaling, NFkB p105, and MAP kinases). Comparison between the A. palmata and an A. millepora EST dataset identified ferritin as a highly expressed gene in both datasets that appears to be undergoing adaptive evolution. Five unigenes appear to be restricted to the Scleractinia, as they had no homology to any sequences in the nr databases nor to the non-scleractinian cnidarians Nematostella vectensis and Hydra magnipapillata. In conclusion, partial sequencing of 5 cDNA libraries each for A. palmata and M. faveolata has produced a rich set of candidate genes (4,980 genes from A. palmata, and 1,732 genes from M. faveolata) that we can use as a starting point for examining the life history and symbiosis of these two species, as well as to further expand the dataset of cnidarian genes for comparative genomics and evolutionary studies.

58 GEOSCIENCES↗

A Novel Dimeric Inhibitor Targeting Beta2GPI in Beta2GPI/Antibody Complexes Implicated in Antiphospholipid Syndrome

Background: b2GPI is a major antigen for autoantibodies associated with antiphospholipid syndrome (APS), an autoimmune disease characterized by thrombosis and recurrent pregnancy loss. Only the dimeric form of b2GPI generated by anti-b2GPI antibodies is pathologically important, in contrast to monomeric b2GPI which is abundant in plasma. Principal Findings: We created a dimeric inhibitor, A1-A1, to selectively target b2GPI in b2GPI/antibody complexes. To make this inhibitor, we isolated the first ligand-binding module from ApoER2 (A1) and connected two A1 modules with a flexible linker. A1-A1 interferes with two pathologically important interactions in APS, the binding of b2GPI/antibody complexes with anionic phospholipids and ApoER2. We compared the efficiency of A1-A1 to monomeric A1 for inhibition of the binding of b2GPI/antibody complexes to anionic phospholipids. We tested the inhibition of b2GPI present in human serum, b2GPI purified from human plasma and the individual domain V of b2GPI. We demonstrated that when b2GPI/antibody complexes are formed, A1-A1 is much more effective than A1 in inhibition of the binding of b2GPI to cardiolipin, regardless of the source of b2GPI. Similarly, A1-A1 strongly inhibits the binding of dimerized domain V of b2GPI to cardiolipin compared to the monomeric A1 inhibitor. In the absence of anti-b2GPI antibodies, both A1-A1 and A1 only weakly inhibit the binding of pathologically inactive monomeric b2GPI to cardiolipin. Conclusions: Our results suggest that the approach of using a dimeric inhibitor to block b2GPI in the pathological multivalent b2GPI/antibody complexes holds significant promise. The novel inhibitor A1-A1 may be a starting point in the development of an effective therapeutic for antiphospholipid syndrome.

59 BASIC BIOLOGICAL SCIENCES↗

Mechanisms of QT prolongation by buprenorphine cannot be explained by direct hERG channel block

Buprenorphine is a μ-opioid receptor (MOR) partial agonist used to manage pain and addiction. QT C prolongation that crosses the 10 msec threshold of regulatory concern was observed at a supratherapeutic dose in two thorough QT studies for the transdermal buprenorphine product BUTRANS®. Because QT C prolongation can be associated with Torsades de Pointes (TdP), a rare but potentially fatal ventricular arrhythmia, these results have led to further investigation of the electrophysiological effects of buprenorphine. Drug-induced QT C prolongation and TdP are most commonly caused by acute inhibition of hERG current (I hERG ) that contribute to the repolarizing phase of the ventricular action potentials (APs). Concomitant inhibition of inward late Na + (I NaL ) and/or L-type Ca 2+ (I CaL ) current can offer some protection against proarrhythmia. Therefore, we characterized the effects of buprenorphine and its major metabolite norbuprenorphine on cardiac hERG, Ca 2+ , and Na + ion channels, as well as cardiac APs. For comparison, methadone, a MOR agonist associated with QT C prolongation and high TdP risk, and naltrexone and naloxone, two opioid receptor antagonists, were also studied. Whole cell recordings were performed at 37°C on cells stably expressing hERG, Ca V 1.2, and Na V 1.5 proteins. Microelectrode array (MEA) recordings were made on human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs). The results showed that buprenorphine, norbuprenorphine, naltrexone, and naloxone had no effect on I hERG , I CaL , I NaL , and peak Na + current (I NaP ) at clinically relevant concentrations. In contrast, methadone inhibited I hERG , I CaL , and I NaL . Experiments on iPSC-CMs showed a lack of effect for buprenorphine, norbuprenorphine, naltrexone, and naloxone, and delayed repolarization for methadone at clinically relevant concentrations. The mechanism of QT C prolongation is opioid moiety-specific. This remains undefined for buprenorphine, while for methadone it involves direct hERG channel block. There is no evidence that buprenorphine use is associated with TdP. Whether this lack of TdP risk can be generalized to other drugs with QT C prolongation not mediated by acute hERG channel block warrants further study.

59 BASIC BIOLOGICAL SCIENCES↗

High-Charge Injector for on-Axis Injection Into A High-Performance Storage Ring Light Source

Next-generation, high-performance storage ring light sources based on multibend achromat optics will require on-axis injection because of the extremely small dynamic aperture. Injectors will need to supply full-current bunch replacement in the ring with high single-bunch charge for swap-out. For upgrades of existing light sources, such as the Advanced Photon Source Upgrade (APS-U), it is economical to retain the existing injector infrastructure and make appropriate improvements. The challenges to these improvements include achieving high single-bunch charge in the presence of instabilities, beam loading, charge stability and reliability. In this paper, we discuss the rationale for the injector upgrades chosen for APS-U, as well as backup and potential alternate schemes. To date, we have achieved single-bunch charge from the injectors that doubles the original design value, and have a goal to achieve about three times the original design value.

43 PARTICLE ACCELERATORS↗