Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACCURACY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Indirect electrochemical method for high accuracy quantification of protein adsorption on gold surfaces

We demonstrate the use of copper underpotential deposition (UPD) for measurement of the electrochemically active surface area of a protein-modified gold electrode. The kinetics of adsorption and the subsequent structural rearrangement of β-casein, as a model protein, on the surface of a gold electrode have been followed over time. The protein-free surface area was determined by measuring the charge derived from UPD copper deposition on the non-blocked surface area at different stages of adsorption. The behaviour of β-casein adsorption as a function of surface roughness and the microstructure of the gold electrode, as well as the concentration of the protein solution, are studied using this method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A study of examiner accuracy in cartridge case comparisons. Part 1: Examiner error rates

This report describes a study undertaken to estimate examiner (not laboratory) error rates for false Identifications and false Eliminations when comparing an unknown to a collection of three known cartridge cases. Volunteer active examiners with Association of Firearm and Toolmark Examiners (AFTE) membership or working in laboratories that participate in the Association of Crime Laboratory Directors (ASCLD) were provided with 15 sets of three known and one questioned cartridge cases fired from a collection of 25 new Ruger SR9 handguns. Remington 9-mm Luger (manufacturer designation L9MM3) ammunition was used and comparison sets were made up of cartridge cases fired within 100 cartridges of each other for each gun. Examiners were provided with a background survey, an answer sheet allowing for the AFTE Range of Conclusions, and return shipping materials. In addition to determining whether the known and questioned cartridge cases were fired with the same handgun, examiners were also asked to assess how many of the three knowns in each set were suitable for comparison, providing an estimated rate of how often each firearm used in the study produces useable, quality marks. The participating examiners were provided with both same-source and different-source comparison sets allowing the study to assess both error rates. Responses were received from 218 participating examiners. The overall rate of false Eliminations was estimated as 0.367% from comparisons known to be from the same firearm but reported as Eliminations. The overall rate of false Identifications was estimated as 1.01% from comparisons known to be from different firearms but reported as Identifications. The rates are not uniform across the sample population with a few examiners providing most of the false Identification responses. Rates of poor-quality mark production varied across the 25 sample handguns; those rates were 2.3% (±1.4%). Both false Elimination and false Identification rates are comparable to or lower than the rate of production of poor-quality marks by the firearms used in this study.

99 GENERAL AND MISCELLANEOUS↗

A study of examiner accuracy in cartridge case comparisons. Part 2: Examiner use of the AFTE range of conclusions

Here, this report describes an analysis of how examiners used the Association of Firearm and Toolmark Examiners (AFTE) Range of Conclusions in a controlled study undertaken to estimate examiner error rates in comparing cartridge cases. Results of the error rate analysis are reported in [1]; this paper focuses on a broader analysis of how the entire collection of classification categories, especially those in the Inconclusive range, were used by the participating examiners. Volunteer active examiners with AFTE membership or working in laboratories that participate in Association of Crime Laboratory Directors (ASCLD) were provided with 15 sets of three known and one questioned cartridge cases fired from a collection of 25 new Ruger SR9 handguns. Remington 9-mm Luger (manufacturer designation L9MM3) ammunition was used and comparison sets were made up of cartridge cases fired within 100 cartridges of each other for each gun. Examiners were provided with a background survey, an answer sheet allowing for the AFTE Range of Conclusions, and return shipping materials. The participating examiners were provided with both same-source and different-source comparison sets allowing the study to assess both error rates. Responses were received from 218 participating examiners. The overall rate of false-negatives was estimated as 0.367 % from comparisons known to be from the same firearm but reported as eliminations. The overall rate of false-positives was estimated as 1.01 % from comparisons known to be from different firearms but reported as identifications. In the case of true different-source examinations, it is clear that the three Inconclusive categories and the Elimination category are not used consistently by all examiners. We identify five different apparent patterns of use of the AFTE Range of Conclusions scale, and discuss possible reasons for and implications of these differences.

99 GENERAL AND MISCELLANEOUS↗

Assessment of human nuclear and mitochondrial DNA qPCR assays for quantification accuracy utilizing NIST SRM 2372a

In forensic DNA casework, a highly accurate real-time quantitative polymerase chain reaction (qPCR) assay is recommended per the Scientific Working Group on DNA Analysis Methods (SWGDAM) (SWGDAM Validation Guidelines for DNA Analysis Methods [1]) to determine whether a DNA sample is of sufficient quantity and robust quality to move forward with downstream short tandem repeats (STR) or sequencing analyses. Most of these assays rely on a standard curve, referred to herein and traditionally as absolute qPCR, in which an unknown is compared, relative to that curve. However, one fundamental issue with absolute qPCR is the quantifiable concentration of commercial assay standards can vary depending on (1) origin, i.e., whether from a cell line or a human subject, (2) supplier, (3) lot number, (4) shipping method, etc. In 2018, the National Institute for Standards and Technology (NIST) released a human DNA standard reference material for evaluating qPCR quantification standards, Standard Reference Material (SRM) 2372a, Romsos et al. (2018) [2] which contains three well-characterized human genomic DNA samples: Component A) a single male1 donor, Component B) a single female 1 donor, and Component C) a 1:3 male 2 :female 2 donor, each with certification data for nDNA and informational mitochondrial DNA(mtDNA)/nuclear DNA (nDNA) ratio data. The SRM 2372a was used to assess four qPCR assays: (1) Quantifiler Trio (Thermo Fisher Scientific, Waltham, MA) for nDNA quantification, (2) NovaQUANT (EMD Millipore Corporation, San Diego, CA) for nDNA and mtDNA quantification, (3) a custom duplex mtDNA assay, and (4) a custom triplex mtDNA assay. Additionally, extracts from eighteen (18) skeletal remains were tested with the latter three assays for concordance of DNA concentration and with assays (2) and (3), for the degradation state. Our assessment revealed that an accurate, efficient, and reproducible qPCR assay is dependent on (1) the quality and reliability of the DNA standard, (2) the qPCR chemistry, and (3) the specific primers, and probes (if applicable), used in an assay. Finally, our findings indicate qPCR assays may not always quantify as expected and that performance of each lot should be verified using a well-characterized DNA standard such as the NIST SRM 2372a and adjusted if warranted.

59 BASIC BIOLOGICAL SCIENCES↗

Using in-situ strain measurements to evaluate the accuracy of stress estimation procedures from fracture injection/shut-in tests

Fracture injection/shut-in tests are commonly used to measure the state of stress. Injection creates a hydraulic fracture (or in some cases, opens a preexisting fracture), and then the pressure after shut-in is monitored to identify fracture closure. Different interpretation procedures have been proposed for estimating closure, and the procedures sometimes yield significantly different results. In this study, direct, in-situ strain measurements are used to observe fracture reopening and closure. The tests were performed as part of the EGS Collab project, a mesoscale project performed at 1.25 and 1.5 km depth at the Sanford Underground Research Facility. The tests were instrumented with the SIMFIP tool, a double-packer probe with a high-resolution three-dimensional borehole displacement sensor. The measurements provide a direct observation of the fracture closure signature, enabling a high-fidelity estimate of the fracture closure stress (ie, the normal stress on the fracture). In two of the four tests, injection created an opening mode fracture, and so the closure stress can be interpreted as the minimum principal stress. In the other two tests, injection probably opened preexisting natural fractures, and so the closure stress can be interpreted as the normal stress on the fractures. The strain measurements are compared against different proposed methods for estimating closure stress from pressure transients. The shut-in transients are analyzed with two techniques that are widely used in the field of petroleum engineering – the ‘tangent’ method and the ‘compliance’ method. In three of the four tests, the tangent method significantly underestimates the closure stress. The compliance method is reasonably accurate in all four tests. Closure stress is also interpreted using two other commonly-used methods – ‘first deviation from linearity’ and the method of Hayashi and Haimson. In comparison with the SIMFIP data, these methods tend to overestimate the closure stress, evidently because they identify closure from early-time transient effects, such as near-wellbore tortuosity. In two of the tests, microseismic imaging provides an independent estimate of the size of the fracture created by injection. When combined with a simple mass balance calculation, the SIMFIP stress measurements yield predictions of fracture size that are reasonably consistent with the estimates from microseismic. In conclusion, the calculations imply an apparent fracture toughness 2-3x higher than typical laboratory-derived values.

58 GEOSCIENCES↗

High accuracy in-situ direct gas analysis of Li-ion batteries

Cycling of lithium-ion batteries containing Ni-rich NMC cathodes at high voltage involves intense gas generation. From the safety standpoint, it is critical to understand how different gas species respond to changes of upper cut-off voltages. In this manuscript, we introduce a novel experimental set up for real-time analysis of gas generation in prismatic pouch cells. In a typical experiment, a lithium-ion pouch cell is directly connected to a quadruple mass spectrometer by glass capillary. Pressure difference helps move the generated gases to the mass spectrometer column for full analysis. The gaseous species are probed during both formation cycle and aging cycles in Li-ion pouch cells comprising NMC811 cathode and graphite anode. The gases are generated upon the creation of the solid electrolyte interphase on graphite during the first formation charge. Besides ethylene gas, C 2 H 4 , whose occurrence is related to the decomposition of ethylene carbonate, a minor solvent decomposition happened at a lower voltage is demonstrated to be associated with residue water on the electrode. For aging cycles, three upper cut-off voltages have been selected to investigate the gas evolution behavior upon charging to 4.2, 4.4 and 4.6 V. Higher upper cut-off voltages do not affect the amount of O 2 measured as a part of the generated oxygen could have reacted with electrolytes. Quite similar and low amounts of O 2 remain in the cells upon charging to the selected cut-off voltages. On the other hand, the generation of CO 2 has been found to be very sensitive to upper cut-off voltage. During similar aging cycles, 6167 nmol $g_{NMC}^{-1}$ of CO 2 is generated at 4.6 V, versus 1650 nmol $g_{NMC}^{-1}$ of CO 2 at 4.4 V, versus 91 nmol $g_{NMC}^{-1}$ of CO 2 at 4.2 V.

25 ENERGY STORAGE↗

Achieving geometric accuracy in FFT-based micromechanical models using conformal grid

Owing to its efficiency, simplicity and robustness, the FFT-based method has become the standard for computation of mechanical fields in a heterogeneous periodic unit cell. One of the main disadvantages of the FFT-based method is the inaccurate representation of the initial microstructure on a regular grid of voxels, which can be alleviated through the use of distorted initial grids. Here, in this paper, a method for generation of distorted initial grids conforming to the microstructural features (e.g. straight/curved boundaries) is proposed. The method determines the positions of the grid nodes in the initial configuration by solving a system of springs connecting the nodes. Microstructures consisting of layers, Voronoi tessellation and circular/spherical inclusions are considered, and mechanical fields simulated using the FFT-based method. It is found that distorted initial grids, conforming to the microstructural features, lead to more accurate mechanical fields in comparison to the corresponding non-distorted initial grid solution. The effect of initial grid distortion on the convergence of the FFT-based method is analyzed and discussed.

36 MATERIALS SCIENCE↗

Enhancing the accuracy and generality of the Debye–Grüneisen Model: Optimizing the volume dependence for accurate predictions across varied compositions

In this work, we have introduced an optimized Debye-Grüneisen model that revolutionizes the determination of the Debye temperature and Grüneisen parameters. Unlike conventional methods, our model requires only the 0 K energy volume data for a material as input, eliminating the need to determine the bulk modulus and its pressure derivative, which often pose challenges due to numerical uncertainties. This unique feature sets our model apart from existing approaches and streamlines the process, enabling accurate predictions of thermal expansion behavior across various materials. To demonstrate its effectiveness, we showcase its excellent agreement with measured coefficients of thermal expansion (CTE) for the nickel-cobalt-chromium-aluminum-yttrium (Ni-Co-Cr-Al-Y) bond-coating system. Additionally, we apply our approach by conducting a high-throughput search for potential bond-coating materials among 90,000 compositions within the aluminum-cobalt-chromium-iron-nickel (Al-Co-Cr-Fe-Ni) system. From this extensive search, four compositions are synthesized, and the measured CTE values agree very well with theoretical predictions, hence validating our approach. In conclusion, the current optimized Debye-Grüneisen model combined with Density Functional Theory (DFT)-based thermodynamic database enables reliable and efficient high-throughput calculations of CTE of of a material without expensive phonon calculations.

Bond coating materials↗