Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Comparison of SOFC Cathode Microstructure Quantified using X-ray Nanotomography and Focused Ioni Beam-scanning Electron Microscopy

X-ray nanotomography and focused ion beam scanning electron microscopy (FIB-SEM) have been applied to investigate the complex 3D microstructure of solid oxide fuel cell (SOFC) electrodes at spatial resolutions of 45 nm and below. The application of near edge differential absorption for x-ray nanotomography and energy selected backscatter detection for FIB-SEM enable elemental mapping within the microstructure. Using these methods, non-destructive 3D x-ray imaging and FIB-SEM serial sectioning have been applied to compare three-dimensional elemental mapping of the LSM, YSZ, and pore phases in the SOFC cathode microstructure. The microstructural characterization of an SOFC cathode is reported based on these measurements. The results presented demonstrate the viability of x-ray nanotomography as a quantitative characterization technique and provide key insights into the SOFC cathode microstructure.

30 DIRECT ENERGY CONVERSION↗

Template-based CTA to x-ray angio rigid registration of coronary arteries in frequency domain with automatic x-ray segmentation

Purpose: A key challenge for image guided coronary interventions is accurate and absolutely robust image registration bringing together preinterventional information extracted from a three-dimensional (3D) patient scan and live interventional image information. In this paper, the authors present a novel scheme for 3D to two-dimensional (2D) rigid registration of coronary arteries extracted from preoperative image scan (3D) and a single segmented intraoperative x-ray angio frame in frequency and spatial domains for real-time angiography interventions by C-arm fluoroscopy.Methods: Most existing rigid registration approaches require a close initialization due to the abundance of local minima and high complexity of search algorithms. The authors' method eliminates this requirement by transforming the projections into translation-invariant Fourier domain for estimating the 3D pose. For 3D rotation recovery, template Digitally Reconstructed Radiographs (DRR) as candidate poses of 3D vessels of segmented computed tomography angiography are produced by rotating the camera (image intensifier) around the DICOM angle values with a specific range as in C-arm setup. The authors have compared the 3D poses of template DRRs with the segmented x-ray after equalizing the scales in three domains, namely, Fourier magnitude, Fourier phase, and Fourier polar. The best rotation pose candidate was chosen by one of the highest similarity measures returned by the methods in these domains. It has been noted in literature that frequency domain methods are robust against noise and occlusion which was also validated by the authors' results. 3D translation of the volume was then recovered by distance-map based BFGS optimization well suited to convex structure of the authors' objective function without local minima due to distance maps. A novel automatic x-ray vessel segmentation was also performed in this study.Results: Final results were evaluated in 2D projection space for patient data; and with ground truth values and landmark distances for the images acquired with a solid phantom vessel. Results validate that rotation recovery in frequency domain is robust against differences in segmentations in two modalities. Distance-map translation is successful in aligning coronary trees with highest possible overlap.Conclusions: Numerical and qualitative results show that single view rigid alignment in projection space is successful. This work can be extended with multiple views to resolve depth ambiguity and with deformable registration to account for nonrigid motion in patient data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A simple method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter

Purpose: The aim of this study was to develop a computerized method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter. Three types of graticules were included in this study: Megavoltage (MV) mechanical graticule, MV electronic portal imaging device digital graticule, and kilovoltage (kV) on-board imaging digital graticule. Methods: A metal ball bearing (BB) was imaged with MV and kV x-ray beams in a procedure similar to a Winston-Lutz test. The radiation fields, graticules, and BB were localized in eight portal images using Hough transform-based computer algorithms. The center of the BB served as a static reference point in the 3D space so that the distances between the graticule centers and the radiation field centers were calculated. The radiation isocenter was determined from the radiation field centers at different gantry angles. Results: Misalignments of MV and kV portal imaging graticules varied with the gantry or x-ray source angle as a result of mechanical imperfections of the linear accelerator and its imaging system. While the three graticules in this study were aligned to the radiation field centers and the radiation isocenter within 2.0 mm, misalignments of 1.5-2.0 mm were found at certain gantry angles. These misalignments were highly reproducible with the gantry rotation. Conclusions: A simple method was developed to quantify the alignments of portal image graticules directly against the radiation field centers or the radiation isocenter. The advantage of this method is that it does not require the BB to be placed exactly at the radiation isocenter through a precalibrated surrogating device such as room lasers or light field crosshairs. The present method is useful for radiation therapy modalities that require high-precision portal imaging such as image-guided stereotactic radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rotational Millimeter-Wave Shoe Scanner Using the Discrete Fourier Transform for Backprojection-Based Image Reconstruction

An active 3D microwave / millimeter-wave shoe scanner was previously developed at the Pacific Northwest National Laboratory (PNNL) using two linear arrays scanned over a rectilinear aperture. The radar system chirps a frequency sweep from 10-40 GHz. These frequencies allow imaging through optically opaque material such as leather, rubber, plastics, and other dielectrics. The system was designed to detect concealed items in the soles of shoes while allowing people to leave their shoes on through a security checkpoint. To shrink the footprint of the system, a new iteration of the design has been developed that scans the two linear arrays over a circular aperture. This new footprint opens the possibility of it being installed in the floor of a cylindrical millimeter-wave body scanner. The backprojection-based multilayer dielectric image reconstruction developed at PNNL can easily handle arbitrary spatial sampling, accommodating the new rotational shoe scanner design. Commonly, the fast Fourier transform (FFT) is used to efficiently compute the range response from the data collected by the system as a preprocessing step to the backprojection algorithm. It was found that converting to range using the discrete Fourier transform (DFT) directly has some advantages over the FFT. For example, nonlinear and non-uniform frequency sweeps can easily be compensated for during the computation of the DFT and only the range bins of interest need to be computed and their spacing can be chosen arbitrarily. Because the range conversion step of the image reconstruction is the fastest part of the process there is very little speed penalty for using the DFT over the FFT and it can even increase the speed of image reconstruction when the ranges of interest are fewer than the total span that is calculated in the FFT.

Millimeter-wave imaging, microwave imaging, shoe s↗

TU-H-BRC-01: A New Fabrication Method for Secondary Skin Collimation Using 3D Scanner and 3D Printer

Purpose: Using secondary skin collimation (SSC) to protect the critical organ surrounding the tumors is always desirable for electron and/or ortho-voltage treatments. However, the time-consuming and labor-intensive fabrication processes of current method (manually fabricate the lead mask) restrict the general use of SSC. The aim of this study is to develop a new SSC fabrication method using 3D scanning and 3D printing technologies in order to largely decrease the human labor involvement and fabrication time, also improve the fabrication accuracy. Methods: First, the patient surface was scanned with a 3D scanner (Structure Sensor, Occipital, CO). The raw scan data was subsequently transferred to a 3D modeling software (Rhinoceros, Ver. 5.0, McNeel North America, Seattle, WA). The tumor contour was then digitized and shielding region was determined by clinicians in the same software. The corresponding SCC conformed to the skin surface was then automatically generated by the software with the proper shielding thickness. The shell of the SCC (with hollow inside) was consequently printed by a 3D printer (Lulzbot TAZ, Aleph Objects, CO) using plastic material. Finally, the hollow mold of SCC was filled up with a melted cerrobend alloy. Once the cerrobend alloy cooled down, the fabrication of SCC was accomplished. Results: The results indicated the proposed method can achieve a much shorter time on making a SCC compared with tradition fabrication method. The processes of making a skin contour model for patients have been eliminated with the new method. SCC created by the new method possessed better accuracy and better conformality to patient’s skin contours. Conclusion: In this study, we have demonstrated a new method for the SCC fabrication. It is anticipated that our method can be an alternative way to replace conventional manual-based methods for electron and/or ortho-voltage SCC fabrication. This research was supported by the Global Ph.D. Fellowship Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (Grant No. 2015H1A2A1034071), Republic of Korea.

60 APPLIED LIFE SCIENCES↗

SwinCell: a 3D transformer and flow-based framework for improved cell segmentation

Segmentation of three-dimensional (3D) cellular images is fundamental for studying and understanding cell structure and function. However, 3D cellular segmentation is challenging, particularly for dense cells and tissues. This challenge arises mainly from the complex contextual information within 3D images, anisotropic properties, and the sensitivity to internal cellular structures, which often lead to incorrect segmentation. In this work, we introduce SwinCell, a 3D transformer-based framework that leverages Swin-transformer to predict flow and differentiate individual cell instances. We demonstrate SwinCell’s utility in the segmentation of nuclei, colon tissue cells, and densely cultured cells. SwinCell strikes a balance between maintaining detailed local feature recognition and understanding broader contextual information. Through extensive testing with both public and in-house 3D cell imaging datasets, SwinCell shows utility in segmenting dense cells, making it a valuable tool for 3D segmentation in cellular analysis that could expedite research in cell biology and tissue engineering.

59 BASIC BIOLOGICAL SCIENCES↗

High frequency (4th order) sequence stratigraphy of Early Miocene deltaic shorelines, offshore Texas and Louisiana

Well logs and 3D seismic reflection data are integrated to image Lower Miocene depocenters of the upper Texas and westernmost Louisiana coastal and offshore areas. Although previously interpreted at a large scale (3rd order cycles), the detailed stratigraphy and depositional history of the early Miocene succession has not been fully developed. The upper lower Miocene interval from Robulus L (MFS10) to Amphistegina B (MFS9) has been further subdivided into five 4th order cycles (each 200 to 300 m thick) to provide finer scale stratigraphic detail and interpretation of depositional environments. Results of the finer scale correlations are presented in a series of sandstone percent maps. Overall, the maps display a strike-elongate (sub-parallel to the present day coastline) orientation for the sandstone bodies which thin to the southeast (basinward). Net sandstone thickness is relatively low in older cycles and increases in younger cycles suggesting an overall progradation of the deltaic system into the mapped area through time. Continued marine regression and southward movement of the shoreline are also confirmed by seismic amplitude 2 maps. After a major transgression associated with Robulus L deltaic progradation occurred under rising sea level conditions. Deltaic sediments prograded southward and sandstone brought to the upper Texas coast was distributed laterally by longshore currents to form strandplain coast lines. Maximum regression occurred during the interval MFS9_2 to MFS9_3 when a deltaic depocenter formed offshore Texas in east High Island area. However, sandstone thickness progressively decreased laterally to the east (offshore Louisiana) where more shale was present and marine processes reworked deltaic derived sandstones into shore parallel bars. There was a clear retreat of the shoreline during the youngest cycle marking the beginning of transgression associated with Amphistegina B . Detailed stratigraphic interpretation (at a 4th order scale) shows more variability in the dominant shoreline processes during early Miocene than previously thought. Recognition of sedimentary systems variability at a 4th order scale is critical for improved hydrocarbon exploration and in understanding potential future CO 2 storage in the area.

58 GEOSCIENCES↗

Direct observation of pore formation mechanisms during LPBF additive manufacturing process and high energy density laser welding

Laser powder bed fusion (LPBF) is a 3D printing technology that can print parts with complex geometries that are unachievable by conventional manufacturing technologies. However, pores formed during the printing process impair the mechanical performance of the printed parts, severely hindering their widespread application. Here, we report six pore formation mechanisms that were observed during the LPBF process. Our results in this study reconfirm three pore formation mechanisms - keyhole induced pores, pore formation from feedstock powder and pore formation along the melting boundary during laser melting from vaporization of a volatile substance or an expansion of a tiny trapped gas. We also observe three new pore formation mechanisms: (1) pore trapped by surface fluctuation, (2) pore formation due to depression zone fluctuation when the depression zone is shallow and (3) pore formation from a crack. The results presented here provide direct evidence and insight into pore formation mechanisms during the LPBF process, which may guide the development of pore elimination/mitigation approaches. Since certain laser processing conditions studied here are similar to the situations in high energy density laser welding, the results presented here also have implications for laser welding.

42 ENGINEERING↗

TU-G-204-04: A Unified Strategy for Bi-Factorial Optimization of Radiation Dose and Contrast Dose in CT Imaging

Purpose: To substantiate the interdependency of contrast dose, radiation dose, and image quality in CT towards the patient- specific optimization of the imaging protocols Methods: The study deployed two phantom platforms. A variable sized (12, 18, 23, 30, 37 cm) phantom (Mercury-3.0) containing an iodinated insert (8.5 mgI/ml) was imaged on a representative CT scanner at multiple CTDI values (0.7–22.6 mGy). The contrast and noise were measured from the reconstructed images for each phantom diameter. Linearly related to iodine-concentration, contrast-to-noise ratio (CNR), were calculated for 16 iodine-concentration levels (0–8.5 mgI/ml). The analysis was extended to a recently developed suit of 58 virtual human models (5D XCAT) with added contrast dynamics. Emulating a contrast-enhanced abdominal image procedure and targeting a peak-enhancement in aorta, each XCAT phantom was “imaged” using a simulation platform (CatSim, GE). 3D surfaces for each patient/size established the relationship between iodine-concentration, dose, and CNR. The ratios of change in iodine-concentration versus dose (IDR) to yield a constant change in CNR were calculated for each patient size. Results: Mercury phantom results show the image-quality size- dependence on CTDI and IC levels. For desired image-quality values, the iso-contour-lines reflect the trade off between contrast-material and radiation doses. For a fixed iodine-concentration (4 mgI/mL), the IDR values for low (1.4 mGy) and high (11.5 mGy) dose levels were 1.02, 1.07, 1.19, 1.65, 1.54, and 3.14, 3.12, 3.52, 3.76, 4.06, respectively across five sizes. The simulation data from XCAT models confirmed the empirical results from Mercury phantom. Conclusion: The iodine-concentration, image quality, and radiation dose are interdependent. The understanding of the relationships between iodine-concentration, image quality, and radiation dose will allow for a more comprehensive optimization of CT imaging devices and techniques, providing the methodology to balance iodine-concentration and dose based on patient’s attributes.

60 APPLIED LIFE SCIENCES↗

Arms Down Cone Beam CT Hepatic Angiography Performance Assessment: Vascular Imaging Quality and Imaging Artifacts

IntroductionThe practice of positioning patients’ arms above the head during catheter-injected hepatic arterial phase cone beam CT (A-CBCT) imaging has been inherited from standard CT imaging due to image quality concerns, but interrupts workflow and extends procedure time. We sought to assess A-CBCT image quality and artifacts with arms extended above the head versus down by the side.MethodsWe performed an IRB approved retrospective evaluation of reformatted and 3D-volume rendered images from 91 consecutive A-CBCTs (43 arms up, 48 arms down) acquired during hepatic tumor arterial embolization procedures. Two interventional radiologists reviewed all A-CBCT imaging and assigned vessel visualization scores (VVS) from 1 to 5, ranging from non-diagnostic to optimal visualization. Streak artifacts across axial images were rated from 1 to 3 based on resulting image quality (none to significant). Presence of respiratory or cardiac motion during acquisition, body mass index and radiation dose area product (DAP) were also recorded and analyzed. Univariate and multivariate analyses were used to assess the impact of arm position on VVS and imaging artifacts.ResultsVVS were not significantly associated with arm position during A-CBCT imaging. One reader reported more streak artifacts across axial images in the arms down group (p = 0.005). DAP was not statistically different between the groups (23.9 Gy cm{sup 2} [6.1–73.4] arms up, 26.1 Gy cm{sup 2} [4.2–102.6] arms down, p = 0.54).ConclusionA-CBCT angiography performed with the arms above the head is not superior for clinically relevant hepatic vascular visualization compared to imaging performed with the arms by the patient’s side.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-18C-03: X-Ray Scatter Correction in Breast CT: Advances and Patient Testing

Purpose: To further develop and perform patient testing of an x-ray scatter correction algorithm for dedicated breast computed tomography (BCT). Methods: A previously proposed algorithm for x-ray scatter signal reduction in BCT imaging was modified and tested with a phantom and on patients. A wireless electronic positioner system was designed and added to the BCT system that positions a tungsten plate in and out of the x-ray beam. The interpolation used by the algorithm was replaced with a radial basis function-based algorithm, with automated exclusion of non-valid sampled points due to patient motion or other factors. A 3D adaptive noise reduction filter was also introduced to reduce the impact of scatter quantum noise post-reconstruction. The impact on image quality of the improved algorithm was evaluated using a breast phantom and seven patient breasts, using quantitative metrics such signal difference (SD) and signal difference-to-noise ratios (SDNR) and qualitatively using image profiles. Results: The improvements in the algorithm resulted in a more robust interpolation step, with no introduction of image artifacts, especially at the imaged object boundaries, which was an issue in the previous implementation. Qualitative evaluation of the reconstructed slices and corresponding profiles show excellent homogeneity of both the background and the higher density features throughout the whole imaged object, as well as increased accuracy in the Hounsfield Units (HU) values of the tissues. Profiles also demonstrate substantial increase in both SD and SDNR between glandular and adipose regions compared to both the uncorrected and system-corrected images. Conclusion: The improved scatter correction algorithm can be reliably used during patient BCT acquisitions with no introduction of artifacts, resulting in substantial improvement in image quality. Its impact on actual clinical performance needs to be evaluated in the future. Research Agreement, Koning Corp., Hologic Inc., Barco Corp Consultant Agreement, Fujifilm Medical Systems.

60 APPLIED LIFE SCIENCES↗

A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization

Purpose: This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopaedic surgery, and rheumatology. Methods: The scanner design incorporated a host of clinical requirements (e.g., ability to scan the weight-bearing knee in a natural stance) and was guided by theoretical and experimental analysis of image quality and dose. Such criteria identified the following basic scanner components and system configuration: a flat-panel detector (FPD, Varian 3030+, 0.194 mm pixels); and a low-power, fixed anode x-ray source with 0.5 mm focal spot (SourceRay XRS-125-7K-P, 0.875 kW) mounted on a retractable C-arm allowing for two scanning orientations with the capability for side entry, viz. a standing configuration for imaging of weight-bearing lower extremities and a sitting configuration for imaging of tensioned upper extremity and unloaded lower extremity. Theoretical modeling employed cascaded systems analysis of modulation transfer function (MTF) and detective quantum efficiency (DQE) computed as a function of system geometry, kVp and filtration, dose, source power, etc. Physical experimentation utilized an imaging bench simulating the scanner geometry for verification of theoretical results and investigation of other factors, such as antiscatter grid selection and 3D image quality in phantom and cadaver, including qualitative comparison to conventional CT. Results: Theoretical modeling and benchtop experimentation confirmed the basic suitability of the FPD and x-ray source mentioned above. Clinical requirements combined with analysis of MTF and DQE yielded the following system geometry: a {approx}55 cm source-to-detector distance; 1.3 magnification; a 20 cm diameter bore (20 x 20 x 20 cm{sup 3} field of view); total acquisition arc of {approx}240 deg. The system MTF declines to 50% at {approx}1.3 mm{sup -1} and to 10% at {approx}2.7 mm{sup -1}, consistent with sub-millimeter spatial resolution. Analysis of DQE suggested a nominal technique of 90 kVp (+0.3 mm Cu added filtration) to provide high imaging performance from {approx}500 projections at less than {approx}0.5 kW power, implying {approx}6.4 mGy (0.064 mSv) for low-dose protocols and {approx}15 mGy (0.15 mSv) for high-quality protocols. The experimental studies show improved image uniformity and contrast-to-noise ratio (without increase in dose) through incorporation of a custom 10:1 GR antiscatter grid. Cadaver images demonstrate exquisite bone detail, visualization of articular morphology, and soft-tissue visibility comparable to diagnostic CT (10-20 HU contrast resolution). Conclusions: The results indicate that the proposed system will deliver volumetric images of the extremities with soft-tissue contrast resolution comparable to diagnostic CT and improved spatial resolution at potentially reduced dose. Cascaded systems analysis provided a useful basis for system design and optimization without costly repeated experimentation. A combined process of design specification, image quality analysis, clinical feedback, and revision yielded a prototype that is now awaiting clinical pilot studies. Potential advantages of the proposed system include reduced space and cost, imaging of load-bearing extremities, and combined volumetric imaging with real-time fluoroscopy and digital radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-62: Three-Dimensional Dosimetric Gamma Analysis for Impacts of Tissue Inhomogeneity Using Monte Carlo Simulation in Intracavitary Brachytheray for Cervix Carcinoma

Purpose: The aim of this study was to investigate the impacts of tissue inhomogeneity on dose distributions using a three-dimensional (3D) gamma analysis in cervical intracavitary brachytherapy using Monte Carlo (MC) simulations. Methods: MC simulations for comparison of dose calculations were performed in a water phantom and a series of CT images of a cervical cancer patient (stage: Ib; age: 27) by employing a MC code, Particle and Heavy Ion Transport Code System (PHIT) version 2.73. The {sup 192}Ir source was set at fifteen dwell positions, according to clinical practice, in an applicator consisting of a tandem and two ovoids. Dosimetric comparisons were performed for the dose distributions in the water phantom and CT images by using gamma index image and gamma pass rate (%). The gamma index is the minimum Euclidean distance between two 3D spatial dose distributions of the water phantom and CT images in a same space. The gamma pass rates (%) indicate the percentage of agreement points, which mean that two dose distributions are similar, within an acceptance criteria (3 mm/3%). The volumes of physical and clinical interests for the gamma analysis were a whole calculated volume and a region larger than t% of a dose (close to a target), respectively. Results: The gamma pass rates were 77.1% for a whole calculated volume and 92.1% for a region within 1% dose region. The differences of 7.7% to 22.9 % between two dose distributions in the water phantom and CT images were found around the applicator region and near the target. Conclusion: This work revealed the large difference on the dose distributions near the target in the presence of the tissue inhomogeneity. Therefore, the tissue inhomogeneity should be corrected in the dose calculation for clinical treatment.

60 APPLIED LIFE SCIENCES↗

STEREOSCOPIC POLAR PLUME RECONSTRUCTIONS FROM STEREO/SECCHI IMAGES

We present stereoscopic reconstructions of the location and inclination of polar plumes of two data sets based on the two simultaneously recorded images taken by the EUVI telescopes in the SECCHI instrument package onboard the Solar TErrestrial RElations Observatory spacecraft. The 10 plumes investigated show a superradial expansion in the coronal hole in three dimensions (3D) which is consistent with the two-dimensional results. Their deviations from the local meridian planes are rather small with an average of 6.{sup 0}47. By comparing the reconstructed plumes with a dipole field with its axis along the solar rotation axis, it is found that plumes are inclined more horizontally than the dipole field. The lower the latitude is, the larger is the deviation from the dipole field. The relationship between plumes and bright points has been investigated and they are not always associated. For the first data set, based on the 3D height of plumes and the electron density derived from SUMER/SOHO Si VIII line pair, we found that electron densities along the plumes decrease with height above the solar surface. The temperature obtained from the density scale height is 1.6-1.8 times larger than the temperature obtained from Mg IX line ratios. We attribute this discrepancy to a deviation of the electron and the ion temperatures. Finally, we have found that the outflow speeds studied in the O VI line in the plumes corrected by the angle between the line of sight and the plume orientation are quite small with a maximum of 10 km s{sup -1}. It is unlikely that plumes are a dominant contributor to the fast solar wind.

99 GENERAL AND MISCELLANEOUS↗

Toward 2D and 3D imaging of magnetic nanoparticles using EPR measurements

Purpose: Magnetic nanoparticles (MNPs) are an important asset in many biomedical applications. An effective working of these applications requires an accurate knowledge of the spatial MNP distribution. A promising, noninvasive, and sensitive technique to visualize MNP distributions in vivo is electron paramagnetic resonance (EPR). Currently only 1D MNP distributions can be reconstructed. In this paper, the authors propose extending 1D EPR toward 2D and 3D using computer simulations to allow accurate imaging of MNP distributions. Methods: To find the MNP distribution belonging to EPR measurements, an inverse problem needs to be solved. The solution of this inverse problem highly depends on the stability of the inverse problem. The authors adapt 1D EPR imaging to realize the imaging of multidimensional MNP distributions. Furthermore, the authors introduce partial volume excitation in which only parts of the volume are imaged to increase stability of the inverse solution and to speed up the measurements. The authors simulate EPR measurements of different 2D and 3D MNP distributions and solve the inverse problem. The stability is evaluated by calculating the condition measure and by comparing the actual MNP distribution to the reconstructed MNP distribution. Based on these simulations, the authors define requirements for the EPR system to cope with the added dimensions. Moreover, the authors investigate how EPR measurements should be conducted to improve the stability of the associated inverse problem and to increase reconstruction quality. Results: The approach used in 1D EPR can only be employed for the reconstruction of small volumes in 2D and 3D EPRs due to numerical instability of the inverse solution. The authors performed EPR measurements of increasing cylindrical volumes and evaluated the condition measure. This showed that a reduction of the inherent symmetry in the EPR methodology is necessary. By reducing the symmetry of the EPR setup, quantitative images of larger volumes can be obtained. The authors found that, by selectively exciting parts of the volume, the authors could increase the reconstruction quality even further while reducing the amount of measurements. Additionally, the inverse solution of this activation method degrades slower for increasing volumes. Finally, the methodology was applied to noisy EPR measurements: using the reduced EPR setup’s symmetry and the partial activation method, an increase in reconstruction quality of ≈80% can be seen with a speedup of the measurements with 10%. Conclusions: Applying the aforementioned requirements to the EPR setup and stabilizing the EPR measurements showed a tremendous increase in noise robustness, thereby making EPR a valuable method for quantitative imaging of multidimensional MNP distributions.

60 APPLIED LIFE SCIENCES↗

DEEPEN 3D PFA Weights for Exploration Datasets in Magmatic Environments

DEEPEN stands for DE-risking Exploration of geothermal Plays in magmatic ENvironments. As part of the development of the DEEPEN 3D play fairway analysis (PFA) methodology for magmatic plays (conventional hydrothermal, superhot EGS, and supercritical), weights needed to be developed for use in the weighted sum of the different favorability index models produced from geoscientific exploration datasets. This GDR submission includes those weights. The weighting was done using two different approaches: one based on expert opinions, and one based on statistical learning. The weights are intended to describe how useful a particular exploration method is for imaging each component of each play type. They may be adjusted based on the characteristics of the resource under investigation, knowledge of the quality of the dataset, or simply to reduce the impact a single dataset has on the resulting outputs. Within the DEEPEN PFA, separate sets of weights are produced for each component of each play type, since exploration methods hold different levels of importance for detecting each play component, within each play type. The weights for conventional hydrothermal systems were based on the average of the normalized weights used in the DOE-funded PFA projects that were focused on magmatic plays. This decision was made because conventional hydrothermal plays are already well-studied and understood, and therefore it is logical to use existing weights where possible. In contrast, a true PFA has never been applied to superhot EGS or supercritical plays, meaning that exploration methods have never been weighted in terms of their utility in imaging the components of these plays. To produce weights for superhot EGS and supercritical plays, two different approaches were used: one based on expert opinion and the analytical hierarchy process (AHP), and another using a statistical approach based on principal component analysis (PCA). The weights are intended to provide standardized sets of weights for each play type in all magmatic geothermal systems. Two different approaches were used to investigate whether a more data-centric approach might allow new insights into the datasets, and also to analyze how different weighting approaches impact the outcomes. The expert/AHP approach involved using an online tool (https://bpmsg.com/ahp/) with built-in forms to make pairwise comparisons which are used to rank exploration methods against one-another. The inputs are then combined in a quantitative way, ultimately producing a set of consensus-based weights. To minimize the burden on each individual participant, the forms were completed in group discussions. While the group setting means that there is potential for some opinions to outweigh others, it also provides a venue for conversation to take place, in theory leading the group to a more robust consensus then what can be achieved on an individual basis. This exercise was done with two separate groups: one consisting of U.S.-based experts, and one consisting of Iceland-based experts in magmatic geothermal systems. The two sets of weights were then averaged to produce what we will from here on refer to as the "expert opinion-based weights," or "expert weights" for short. While expert opinions allow us to include more nuanced information in the weights, expert opinions are subject to human bias. Data-centric or statistical approaches help to overcome these potential human biases by focusing on and drawing conclusions from the data alone. More information on this approach along with the dataset used to produce the statistical weights may be found in the linked dataset below.

15 GEOTHERMAL ENERGY↗

TH-A-19A-01: An Open Source Software for Proton Treatment Planning in Heterogeneous Medium

Purpose: Due to its success in Radiation Oncology during the last decade, interest in proton therapy is on the rise. Unfortunately, despite the global enthusiasm in the field, there is presently no free, multiplatform and customizable Treatment Planning System (TPS) providing proton dose distributions in heterogenous medium. This restricts substantially the progress of clinical research for groups without access to a commercial Proton TPS. The latest implementation of our pencil beam dose calculation algorithm for proton beams within the 3D Slicer open-source environment fulfills all the conditions described above. Methods: The core dose calculation algorithm is based on the Hong algorithm (1), which was upgraded with the Kanematsu theory describing the evolution of the lateral scattering of proton beamlets in heterogeneous medium. This algorithm deals with both mono-energetic beams and Spread Out Bragg Peak (SOBP). In order to be user-friendly, we provide a graphical user interface implemented with the Qt libraries, and visualization with the 3D Slicer medical image analysis software. Two different pencil beam algorithms were developed, and the clinical proton beam line at our facility was modeled. Results: The dose distributions provided by our algorithms were compared to dose distributions coming from both commercialized XiO TPS and literature (dose measurements, GEANT4 and MCNPx) and turned out to be in a good agreement, with maximum dose discrepancies of 5% in homogeneous phantoms and 10% in heterogeneous phantoms. The algorithm of SOBP creation from an optimized weigthing of mono-energetic beams results in flat SOBP. Conclusion: We hope that our efforts in implementing this new, open-source proton TPS will help the research groups to have a free access to a useful, reliable proton dose calculation software.(1) L. Hong et al., A pencil beam algorithm for proton dose calculations, Phys. Med. Biol. 41 (1996) 1305–1330. This project is paid for by NCI/MGH Federal share as a research grant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery

The authors developed a fast and accurate two-dimensional (2D)-three-dimensional (3D) image registration method to perform precise initial patient setup and frequent detection and correction for patient movement during image-guided cranial radiosurgery treatment. In this method, an approximate geometric relationship is first established to decompose a 3D rigid transformation in the 3D patient coordinate into in-plane transformations and out-of-plane rotations in two orthogonal 2D projections. Digitally reconstructed radiographs are generated offline from a preoperative computed tomography volume prior to treatment and used as the reference for patient position. A multiphase framework is designed to register the digitally reconstructed radiographs with the x-ray images periodically acquired during patient setup and treatment. The registration in each projection is performed independently; the results in the two projections are then combined and converted to a 3D rigid transformation by 2D-3D geometric backprojection. The in-plane transformation and the out-of-plane rotation are estimated using different search methods, including multiresolution matching, steepest descent minimization, and one-dimensional search. Two similarity measures, optimized pattern intensity and sum of squared difference, are applied at different registration phases to optimize accuracy and computation speed. Various experiments on an anthropomorphic head-and-neck phantom showed that, using fiducial registration as a gold standard, the registration errors were 0.33{+-}0.16 mm (s.d.) in overall translation and 0.29 deg. {+-}0.11 deg. (s.d.) in overall rotation. The total targeting errors were 0.34{+-}0.16 mm (s.d.), 0.40{+-}0.2 mm (s.d.), and 0.51{+-}0.26 mm (s.d.) for the targets at the distances of 2, 6, and 10 cm from the rotation center, respectively. The computation time was less than 3 s on a computer with an Intel Pentium 3.0 GHz dual processor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗