Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “39”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Antirestenotic Effects of a Novel Polymer-Coated D-24851 Eluting Stent. Experimental Data in a Rabbit Iliac Artery Model

Experimental and clinical data suggest that stents eluting antiproliferative agents can be used for the prevention of in-stent restenosis. Here we investigate in vitro the antiproliferative and apoptotic effect of D-24851 and evaluate the safety and efficacy of D-24851-eluting polymer-coated stents in a rabbit restenosis model (n = 53). Uncoated stents (n = 6), poly (dl-lactide-co-glycolide) (PLGA)-coated stents (n = 7), and PLGA-coated stents loaded with 0.08 {+-} 0.0025 {mu}M (31 {+-} 1 {mu}g; low dose; n = 7), 0.55 {+-} 0.02 {mu}M (216 {+-} 8 {mu}g; high dose; n = 6), and 4.55 {+-} 0.1 {mu}M (1774 {+-} 39 {mu}g; extreme dose; n = 5) of D-24851 were randomly implanted in New Zealand rabbit right iliac arteries and the animals were sacrificed after 28 days for histomorphometric analysis. For the assessment of endothelial regrowth in 90 days, 12 rabbits were subjected to PLGA-coated (n = 3), low-dose (n = 3), high-dose (n = 3), and extreme-dose (n = 3) stent implantation. In vitro studies revealed that D-24851 exerts its growth inhibitory effects via inhibition of proliferation and induction of apoptosis without increasing the expression of heat shock protein-70, a cytoprotective and antiapoptotic protein. Treatment with low-dose D-24851 stents was associated with a significant reduction in neointimal area and percentage stenosis only compared with bare metal stents (38% [P = 0.029] and 35% [P = 0.003] reduction, respectively). Suboptimal healing, however, was observed in all groups of D-24851-loaded stents in 90 days in comparison with PLGA-coated stents. We conclude that low-dose D-24851-eluting polymer-coated stents significantly inhibit neointimal hyperplasia at 28 days through inhibition of proliferation and enhancement of apoptosis. In view of the suboptimal re-endothelialization, longer-term studies are needed in order to establish whether the inhibition of intimal growth is maintained.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large Renal Artery Aneurysm Treated with Guglielmi Detachable Coils: Procedural and 4-Year Follow-up Results

A large aneurysm of the left renal artery was found incidentally during abdominal ultrasound in a 39-year-old woman with no medical or family history of cardiovascular disease. Vascular pathology with a dysplastic appearance was confirmed by magnetic resonance angiography and the patient was offered transcatheter embolization. Since the position and size of the neck of the aneurysm could not be determined at angiography, detachable platinum coils were used for occlusion. The procedure was performed without complications. During a 4-year follow-up no alterations of renal function, recanalization of the aneurysm, or perfusion defects in the rest of the left renal circulation were noted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Retrievable Compared to Permanent Inferior Vena Cava Filters: A Single-Institution Experience

The purpose of this study was to review the use, safety, and efficacy of retrievable inferior vena cava (IVC) filters in their first 5 years of availability at our institution. Comparison was made with permanent filters placed in the same period. A retrospective review of IVC filter implantations was performed from September, 1999, to September, 2004, in our department. These included both retrievable and permanent filters. The Recovery nitinol and Guenther tulip filters were used as retrievable filters. The frequency of retrievable filter used was calculated. Clinical data and technical data related to filter placement were reviewed. Outcomes, including pulmonary embolism, complications associated with placement, retrieval, or indwelling, were calculated. During the study period, 604 IVC filters were placed. Of these, 97 retrievable filters (16%) were placed in 96 patients. There were 53 Recovery filter and 44 Tulip filter insertions. Subjects were 59 women and 37 men; the mean age was 52 years, with a range of from 18 to 97 years. The placement of retrievable filters increased from 2% in year 1 to 32% in year 5 of the study period. The total implantation time for the permanent group was 145,450 days, with an average of 288 days (range, 33-1811 days). For the retrievable group, the total implantation time was 21,671 days, with an average of 226 days (range, 2-1217 days). Of 29 patients who returned for filter retrieval, the filter was successfully removed in 28. There were 14 of 14 successful Tulip filter retrievals and 14 of 15 successful Recovery filter retrievals. In one patient, after an indwelling period of 39 days, a Recovery nitinol filter could not be removed secondary to a large clot burden within the filter. For the filters that were removed, the mean dwell time was 50 days for the Tulip type and 20 days for the Recovery type. Over the follow-up period there was an overall PE incidence of 1.4% for the permanent group and 1% for the retrieval group. In conclusion, there was an increase in the use of retrievable filters over the study period and an overall increase in the total number of filters implanted. The increased use of these filters appeared to be due to expanded indications predicated by their retrievability. Placement and retrieval of these filters have a low risk of complications, and retrievable filters appeared effective, as there was low rate of clinically significant pulmonary embolism associated with these filters during their indwelling time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic Yield of Computed Tomography-Guided Coaxial Core Biopsy of Undetermined Masses in the Free Retroperitoneal Space: Single-Center Experience

The purpose of this study was to evaluate the diagnostic yield of core biopsy in coaxial technique under guidance of computed tomography (CT) for retroperitoneal masses. We performed a retrospective analysis of CT-guided coaxial core biopsies of undetermined masses in the non-organ-bound retroperitoneal space in 49 patients. In 37 cases a 15-G guidance needle with a 16-G semiautomated core biopsy system, and in 12 cases a 16-G guidance needle with an 18-G biopsy system, was used. All biopsies were technically successful. A small hematoma was seen in one case, but no relevant complication occurred. With the coaxial technique, up to 4 specimens were obtained from each lesion (mean, 2.8). Diagnostic accuracy in differentiation between malignant and benign diseases was 95.9%. A specific histological diagnosis could be established in 39 of 42 malignant lesions (92.9%). Correct subtyping of malignant lymphoma according to the WHO classification was possible in 87.0%. Benign lesions were correctly identified in seven cases, although a specific diagnosis could only be made in conjunction with clinical and radiological information. In conclusion, CT-guided coaxial core biopsy provides safe and accurate diagnosis of retroperitoneal masses. A specific histological diagnosis, which is essential for choosing the appropriate therapy, could be established in most cases of malignancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anatomical Variations of the Popliteal Artery and its Tibial Branches: Analysis in 1242 Extremities

The purpose of this study was to analyze the variations in branching of the popliteal artery by reviewing femoral arteriograms. Between 2004 and 2006, digital subtraction angiographies of both lower extremities were performed in 621 patients. We reviewed these 1242 arteriograms retrospectively in order to analyze the branching pattern of the popliteal artery. Of the 1242 extremities, 1108 extremities (89.2%) had normal branching pattern of the popliteal artery. The remaining 134 extremities (10.8%; 65 right, 69 left) in 105 patients (66 men, 39 women; 76 unilateral, 29 bilateral) showed seven variant branching patterns: hypoplastic or aplastic posterior tibial artery (PT) (n = 63, 5.1%); hypoplastic or aplastic anterior tibial artery (AT) (n = 21, 1.7%); trifurcation (n = 19, 1.5%); high origin of AT (n = 15, 1.2%); hypoplastic or aplastic PT and AT (n = 10, 0.8%); high origin of PT (n = 5, 0.4%); and anterior tibioperoneal trunk (n = 1, 0.1%). When the branching pattern of the popliteal artery is normal in one extremity, there is a 13% probability the other side will be a variant pattern. When the branching pattern is variant in one extremity, there is a 28% probability the opposite side will also contain a variation. Variations in branching of the popliteal artery are not uncommon. Awareness of these variations is important for evaluation of the lower extremity arteriograms and has clinical implications for vascular surgeons and interventional radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of Centerline of Flow Measurement for Sizing of the Zenith AAA Endovascular Graft and Predictive Factor for Risk of Inadequate Sizing

The purpose of this study was to evaluate the accuracy of centerline of flow (CLF) measurement for precise sizing of the Zenith AAA endovascular graft (Zenith) and to identify predictive factors of risk of inadequate endograft sizing. We analyzed 42 consecutive patients treated using the Zenith with pre- and postoperative multidetector CT between 2001 and 2007. Endograft sizing was retrospectively performed using CLF on a three-dimensional workstation. The following parameters were investigated: (a) change in distance from lowest renal artery to hypogastric artery between CLF on preoperative CT (CLFp) and CLF of graft path on postoperative CT (CLFg); (b) supposed success rate of adequate endograft length selection; and (c) predictive factors for significant alteration (>10 mm) between CLFp and CLFg. Median change in distance from lowest renal artery to hypogastric artery was 4 mm. CLFg was >10 mm shorter than CLFp in 10 of 84 limbs (12%). Multivariate analysis demonstrated tortuosity index (TI) of infrarenal abdominal aorta (p = 0.019), aneurysm diameter (p = 0.035), and ipsilateral side of the main body insertion (p = 0.042) as predictive factors of significant alteration between CLFp and CLFg. Adequate endograft length selection was achieved in 39 of 42 cases (93%). All three inadequate endograft length selections were associated with tortuous aorta (TI > 20 mm). In conclusion, distance calculations based on CLF measurement provided accurate length selection of the Zenith in the majority of cases. TI, aneurysm diameter, and ipsilateral side were predictive factors for significant alteration. The CLF and aortic measurements including the TI may allow for improved sizing for Zenith placements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Rhenium-188, Gemcitabine, and 5-Fluorouracil on Cholangiocellular Carcinoma Cells: An In Vitro Study

The purpose of this study was to compare the beneficial effects of radioactive stents and radioactive stents plus additional chemotherapy in the palliative treatment of cholangiocellular carcinomas. Cholangiocellular carcinoma cells (TFK-1 cells) were treated either with 8 Gy (RTB group) or 16 Gy (RTA group) {sup 188}Re or with {sup 188}Re irradiation (8 Gy) combined with either gemcitabine (8 Gy/Gem) or 5-fluorouracil (8 Gy/5-FU) at a dosage of 20 {mu}g/ml medium for 4 days and subsequently compared with an untreated control group. Proliferation kinetics were assessed on days 4, 7, 11, 18, 25, and 32. Colony formation assays were performed on days 7, 18, and 32 and cell cycle distribution was examined on days 4, 7, 11, 15, 25, and 39. Cell proliferation kinetics showed the lowest cell numbers in the 8 Gy/5-FU group (control, 15,390,000; RTA group, 8,394,000; RTB group, 5,609,000; 8 Gy/Gem group, 423,000; and 8 Gy/5-FU group, 297,667). In contrast, clonogenic activity on day 32 was lower in the 8 Gy/Gem group (control, 29.3 colonies; RTB group, 23.1 colonies; 8 Gy/5-FU group, 21.5 colonies; 8 Gy/Gem, 3.3 colonies; and even augmented in the RTA group, with 37.7 colonies). Cell cycle distribution showed similar curves for all groups on slightly different levels except for the 8 Gy/5-FU group, which showed a relatively augmented percentage of cells on day 7 in the G2 M cycle phase and on day 4 in the S phase. In conclusion, irradiation (8 Gy) with {sup 188}Re administered, e.g., via coated stents, combined with Gem could be a valid option for the treatment of CCCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

One Year Clinical Outcomes of Renal Artery Stenting: The Results of ODORI Registry

The safety, efficacy and long term clinical benefits of renal artery revascularization by stenting are still a matter of debate. The aim of our study was to define the safety and efficacy of renal artery stenting with the Tsunami peripheral stent (Terumo Corporation, Tokyo, Japan). The ODORI was a prospective, multicentre registry which enrolled 251 consecutive patients, (276 renal arteries) in 36 centres across Europe. The primary endpoint was acute procedural success defined as <30% residual stenosis after stent placement. Secondary endpoints included major adverse events, blood pressure control, serum creatinine level, and target lesion revascularization (TLR) at 6 and 12 months. Patients were 70 {+-} 10 years old, 59% were male, 33% had diabetes, and 96% hypertension. The main indications for renal stent implantation were hypertension in 83% and renal salvage in 39%. Direct stent implantation was performed in 76% of the cases. Acute success rate was 100% with residual stenosis of 2.5 {+-} 5.4%. Systolic/diastolic blood pressure decreased from a mean of 171/89 at baseline to 142/78 mmHg at 6 months (p < 0.0001 vs. baseline), and 141/80 mmHg at 12 months (p < 0.0001 vs. baseline). Mean serum creatinine concentration did not change significantly in the total population. However, there was significant improvement in the highest tercile (from 283 {mu}mol/l at baseline to 205 and 209 {mu}mol/l at 6 and 12 months respectively). At 12-months, rates of restenosis and TLR were 6.6 and 0.8% respectively. The 12 month cumulative rate of all major clinical adverse events was 6.4% while the rate of device or procedure related events was 2.4%. In hypertensive patients with atherosclerotic renal artery stenosis Tsunami peripheral balloon-expandable stent provides a safe revascularization strategy, with a potential beneficial impact on hypertension control and renal function in the highest risk patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of a Perforation of the Vena Caval Wall Caused by the Retrieval of a Gunther Tulip Filter After Long-Term Implantation

Symptomatic penetration of the inferior vena cava (IVC) wall reportedly occurs in 0.3% of patients in whom a filter has been implanted, and it causes injury to the adjacent structures (Bogue et al. in Pediatr Radiol 39(10):1110-1113, 1; Brzezinski et al. in Burns 32(5):640-643, 2). We succeeded in the endovascular repair of perforation of the IVC wall occurring during the retrieval of a penetrated Gunther tulip vena cava filter (Cook, Bjaeverskov, Denmark) after long-term implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uterine Artery Embolization for Leiomyomata: Optimization of the Radiation Dose to the Patient Using a Flat-Panel Detector Angiographic Suite

The purpose of this study was to assess the ability of low-dose/low-frame fluoroscopy/angiography with a flat-panel detector angiographic suite to reduce the dose delivered to patients during uterine fibroid embolization (UFE). A two-step prospective dosimetric study was conducted, with a flat-panel detector angiography suite (Siemens Axiom Artis) integrating automatic exposure control (AEC), during 20 consecutive UFEs. Patient dosimetry was performed using calibrated thermoluminescent dosimeters placed on the lower posterior pelvis skin. The first step (10 patients; group A) consisted in UFE (bilateral embolization, calibrated microspheres) performed using the following parameters: standard fluoroscopy (15 pulses/s) and angiography (3 frames/s). The second step (next consecutive 10 patients; group B) used low-dose/low-frame fluoroscopy (7.5 pulses/s for catheterization and 3 pulses/s for embolization) and angiography (1 frame/s). We also recorded the total dose-area product (DAP) delivered to the patient and the fluoroscopy time as reported by the manufacturer's dosimetry report. The mean peak skin dose decreased from 2.4 {+-} 1.3 to 0.4 {+-} 0.3 Gy (P = 0.001) for groups A and B, respectively. The DAP values decreased from 43,113 {+-} 27,207 {mu}Gy m{sup 2} for group A to 9,515 {+-} 4,520 {mu}Gy m{sup 2} for group B (P = 0.003). The dose to ovaries and uterus decreased from 378 {+-} 238 mGy (group A) to 83 {+-} 41 mGy (group B) and from 388 {+-} 246 mGy (group A) to 85 {+-} 39 mGy (group B), respectively. Effective doses decreased from 112 {+-} 71 mSv (group A) to 24 {+-} 12 mSv (group B) (P = 0.003). In conclusion, the use of low-dose/low-frame fluoroscopy/angiography, based on a good understanding of the AEC system and also on the technique during uterine fibroid embolization, allows a significant decrease in the dose exposure to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovenous Laser Ablation of the Small Saphenous Vein Sparing the Saphenopopliteal Junction

To assess outcomes after endovenous laser ablation (EVLA) of the small saphenous vein (SSV). Retrospective review was performed of all consecutive EVLA procedures performed over a 39-month period at three neighboring vein practices for symptomatic, duplex ultrasound-proven incompetence of the SSV. EVLA was performed under ultrasound guidance with an 810- or 980-nm diode laser in continuous mode using the pullback method while sparing the deep, most cephalad segment of the SSV near the saphenopopliteal junction. Follow-up after EVLA included patient symptoms, physical examination, and duplex ultrasound. Pretreatment variables were similar across all three practices. EVLA was performed to treat 67 incompetent SSVs in 63 patients (86% women; mean age and 95% confidence interval, 50 {+-} 3 years; range, 20-82 years). Average energy delivered was 92 J/cm. Immediate technical success and occlusion of the treated vein at 1-2 weeks was 100%. Imaging follow-up length was 243 {+-} 65 days (range, 3-893 days). Clinical follow-up (243 {+-} 66 days) showed symptomatic improvement in 66 (99%) of 67 patients; one patient had recanalization with recurrent reflux by ultrasound (2%). Complications included one case of paresthesias lasting beyond 1 month of follow-up (2%) and three cases of superficial phlebitis (4%), but no deep vein thrombosis, skin burns, or other complications. Although ablation involved only the superficial portion of the SSV and spared its deep segment in the popliteal fossa, SSV occlusion typically extended up to the saphenopopliteal junction or to a gastrocnemial collateral, without popliteal vein involvement. EVLA of the SSV is safe and effective when the saphenopopliteal junction and popliteal fossa are avoided. This approach may help reduce the risk of paresthesias or other complications while maintaining low recanalization rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Standard Pushable Coils with Fibered Interlock Detachable Coils

The purpose of this study was compare embolization of the gastroduodenal artery (GDA) using standard pushable coils with the Interlock detachable coil (IDC), a novel fibered mechanically detachable long microcoil, in patients scheduled for selective internal radiotherapy (SIRT). Fifty patients (31 male and 19 female; median age 66.6 {+-} 8.1 years) were prospectively randomized for embolization using either standard coils or IDCs. Procedure time, radiation dose, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography were recorded. The procedures differed significantly in time (14:32 {+-} 5:56 min for standard coils vs. 2:13 {+-} 1:04 min for IDCs; p < 0.001); radiation dose for coil deployment (2479 {+-} 1237 cGycm Superscript-Two for standard coils vs. 275 {+-} 268 cGycm Superscript-Two for IDCs; p < 0.001); and vessel occlusion (17:18 {+-} 6:39 min for standard coils vs. 11:19 {+-} 7:54 min for IDCs; p = 0.002). A mean of 6.2 {+-} 1.8 coils (n = 27) were used in the standard coil group, and 1.3 {+-} 0.9 coils (p < 0.0001) were used in the IDC group (n = 23) because additional pushable coils were required to achieve GDA occlusion in 4 patients. In 2 patients, the IDC could not be deployed through a Soft-VU catheter. One standard coil dislodged in the hepatic artery and was retrieved. Vessel reperfusion was noted in only 1 patient in the standard coil group. Controlled embolization of the GDA with fibered IDCs was achieved more rapidly than with pushable coils. However, vessel occlusion may not be obtained using a single device only, and the use of sharply angled guiding catheters hampered coil pushability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of BMSs with SES for Symptomatic Intracranial Disease of the Middle Cerebral Artery Stenosis

This study was designed to compare the clinical and angiographic outcomes of patients with symptomatic atherosclerotic middle cerebral artery stenosis treated with balloon-mounted stents (BMS) and self-expandable Wingspan system (SES). We reviewed the 69 consecutive stent placement procedures for symptomatic atherosclerotic stenosis ({>=}70) in M1 segment of middle cerebral artery in 67 patients in 3 years. According to the stent types, the patients were classed as BMS and SES groups. The demographic characteristics, conventional risk factors of ischemic stroke, degree of stenosis, periprocedural complications, stent types, and clinical and angiographic outcomes were analyzed. There were 39 patients in the BMS group and 28 patients in the SES group. The demographic characteristics, conventional risk factors, and periprocedural complications were similar but different in residual stenosis after stenting in both groups (5.9% {+-} 9.9% vs. 14.4% {+-} 14.6%; P = 0.01). For the overall cohort, the rate of stroke or death and restenosis was 10.9% (7/66) and 24.5% (14/57), respectively. The frequency of restenosis was higher in the SES group than in the BMS group (log-rank, P = 0.04; crude hazard ratio = 3.03; 95% confidence interval (CI), 1.01-9.15; P = 0.049; and adjusted hazard ratio = 3.61; 95% CI, 1.06-12.27; P = 0.04); however, there was no difference in clinical outcomes (log-rank, P = 0.51; crude hazard ratio = 1.66; 95% CI, 0.36-7.61; P = 0.51; and adjusted hazard ratio = 0.59; 95% CI, 0.04-7.89; P = 0.69). The corrected degree of restenosis was higher in the SES than the BMS group. The prevalence of restenosis was higher in the SES than the BMS group, but the perioperative complications and follow-up clinical outcomes had no significant difference.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57-93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 {+-} 13 (SD) min (range 24-78). The average follow-up time interval was 103 days (range 7-812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sustained Growth of the Ex Vivo Ablation Zones' Critical Short Axis Using Gas-cooled Radiofrequency Applicators

Purpose: To evaluate the ablation zones created with a gas-cooled bipolar radiofrequency applicator performed on ex vivo bovine liver tissue. Materials and Methods: A total of 320 ablations with an internally gas-cooled bipolar radiofrequency applicator were performed on fresh ex vivo bovine liver tissue, varying the ablation time (5, 10, 15, and 20 min), power (20, 30, 40, and 50 W), and gas pressure of the CO{sub 2} used for cooling (585, 600, 615, 630, 645 psi), leading to a total of 80 different parameter combinations. Size and shape of the white coagulation zone were assessed. Results: The largest complete ablation zone was achieved after 20 min of implementing 50 W and 645 psi, resulting in a short axis of mean 46 {+-} 1 mm and a long axis of 56 {+-} 2 mm (mean {+-} standard deviation). Short-axis diameters increased between 5 and 20 min of ablation time at 585 psi (increase of the short axis was 45% at 30 W, 29% at 40 W, and 39% at 50 W). This increase was larger at 645 psi (113% at 30 W, 67% at 40 W, and 70% at 50 W). Macroscopic assessment and NADH (nicotinamide adenine dinucleotide) staining revealed incompletely ablated tissue along the needle track in 18 parameter combinations including low-power settings (20 and 30 W) and different cooling levels and ablation times. Conclusion: Gas-cooled radiofrequency applicators increase the short-axis diameter of coagulation in an ex vivo setting if appropriate parameters are selected.

60 APPLIED LIFE SCIENCES↗

Embolization of Hepatic Arterial Branches to Simplify Hepatic Blood Flow Before Yttrium 90 Radioembolization: A Useful Technique in the Presence of Challenging Anatomy

Purpose: In the presence of variant hepatic arterial anatomy, obtaining whole-liver coverage with yttrium 90 (Y90) radioembolization may be challenging. The purpose of this study was to determine whether a technique whereby variant hepatic arterial branches are embolized and then Y90 is administered selectively into one remaining hepatic arterial branch results in whole-liver coverage and effective therapy. A retrospective comparison of treatment response was made between a group of patients who underwent this technique before Y90 administration and a group of patients who received standard Y90 administration as a single dose into the proper hepatic artery or in divided doses into the immediate hepatic artery branches. The rest of the workup and treatment were identical in both groups, including routine embolization of potential nonhepatic, nontarget vessels (e.g., the gastroduodenal artery). Methods: A total of 32 patients (mean age 56.9 years, range 39-77 years) treated with Y90 between June 2004 and March 2008 were analyzed. The primary malignancy was colorectal in 29, breast in 2, and cholangiocarcinoma in 1. Group 1 comprised 20 patients who had no alterations to their hepatic arterial supply. Group 2 comprised 12 cases who had undergone prior embolization of hepatic arterial branches before administration of Y90. The response to treatment was assessed by comparing standardized uptake value (SUV) on the pre- and postprocedure fludeoxyglucose positron emission tomographic studies of representative lesions within the right and left lobes of the liver. Results: In group 1, significant response (P < 0.001) was seen among right lobe lesions but not among left lobe lesions (P = 0.549). In group 2, there was a significant response among both right (P = 0.028) and left (P = 0.014) lobe lesions. No difference was found in the response of right lobe lesions (P = 0.726) between groups 1 and 2; a significantly greater response was found in group 2 compared to group 1 (P = 0.004) for left lobe lesions. Conclusion: Selective Y90 radioembolization after manipulation of hepatic arterial blood supply leads to an even distribution within the entire liver. When variations in hepatic arterial anatomy exist, this technique allows effective whole-liver radioembolization therapy from a single selective arterial injection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Biliary Cast Syndrome After Orthotopic Liver Transplantation: Comparison of Mechanical Versus Hydraulic Rheolytic Cast Extraction

Purpose: Biliary cast syndrome (BCS) is the presence of casts within the intrahepatic or extrahepatic biliary system after orthotopic liver transplantation. Our work compares two percutaneous methods for BCS treatment: the mechanical cast-extraction technique (MCE) versus the hydraulic cast-extraction (HCE) technique using a rheolytic system. Materials and Methods: A total of 24 patients were included in the study. Six patients were referred for HCE, and 18 patients were treated with MCE. A statistically significant larger number of sessions was required in the MCE group (21.0, range 11 to 72 sessions) (p = 0.033). Results: Median therapy duration was shorter in the HCE group at 2.4 months (range 2 to 5) compared with 6.7 months (range 3 to 39) in the MCE group (p < 0.001). Both patient acceptance was better and costs for total therapy were 40% less in the HCE group. No significant differences where found concerning clinical and biochemical improvement or graft and patient survival. Conclusion: The use of the hydraulic rheolytic system decreased total therapy time, thereby decreasing the induced inflammation time of the biliary tree. A significant benefit of HCE has been observed in our patients when we compare our results with those of MCE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Radiofrequency Ablation of Lung Cancer on Pulmonary Function

Purpose: The purpose of this study was to evaluate altered pulmonary function retrospectively after RFA. Methods: This retrospective study comprised 41 ablation sessions for 39 patients (22 men and 17 women; mean age, 64.8 years). Vital capacity (VC) and forced expiratory volume in 1 s (FEV{sub 1}) at 1 and 3 months after RFA were compared with the baseline (i.e., values before RFA). To evaluate the factors that influenced impaired pulmonary function, univariate analysis was performed by using multiple variables. If two or more variables were indicated as statistically significant by univariate analysis, these variables were subjected to multivariate analysis to identify independent factors. Results: The mean VC and FEV{sub 1} before RFA and 1 and 3 months after RFA were 3.04 and 2.24 l, 2.79 and 2.11 l, and 2.85 and 2.13 l, respectively. The values at 1 and 3 months were significantly lower than the baseline. Severe pleuritis after RFA was identified as the independent factor influencing impaired VC at 1 month (P = 0.003). For impaired FEV{sub 1} at 1 month, only severe pleuritis (P = 0.01) was statistically significant by univariate analysis. At 3 months, severe pleuritis (VC, P = 0.019; FEV{sub 1}, P = 0.003) and an ablated parenchymal volume {>=}20 cm{sup 3} (VC, P = 0.047; FEV{sub 1}, P = 0.038) were independent factors for impaired VC and FEV{sub 1}. Conclusions: Pulmonary function decreased after RFA. RFA-induced severe pleuritis and ablation of a large volume of marginal parenchyma were associated with impaired pulmonary function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗