Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “utilization plan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Slow Solar Wind Connection Science during Solar Orbiter's First Close Perihelion Passage

The Slow Solar Wind Connection Solar Orbiter Observing Plan (Slow Wind SOOP) was developed to utilize the extensive suite of remote-sensing and in situ instruments on board the ESA/NASA Solar Orbiter mission to answer significant outstanding questions regarding the origin and formation of the slow solar wind. The Slow Wind SOOP was designed to link remote-sensing and in situ measurements of slow wind originating at open–closed magnetic field boundaries. The SOOP ran just prior to Solar Orbiter's first close perihelion passage during two remote-sensing windows (RSW1 and RSW2) between 2022 March 3–6 and 2022 March 17–22, while Solar Orbiter was at respective heliocentric distances of 0.55–0.51 and 0.38–0.34 au from the Sun. Coordinated observation campaigns were also conducted by Hinode and IRIS. The magnetic connectivity tool was used, along with low-latency in situ data and full-disk remote-sensing observations, to guide the target pointing of Solar Orbiter. Solar Orbiter targeted an active region complex during RSW1, the boundary of a coronal hole, and the periphery of a decayed active region during RSW2. Postobservation analysis using the magnetic connectivity tool, along with in situ measurements from MAG and SWA/PAS, showed that slow solar wind originating from two out of three of the target regions arrived at the spacecraft with velocities between ∼210 and 600 km s −1 . The Slow Wind SOOP, despite presenting many challenges, was very successful, providing a blueprint for planning future observation campaigns that rely on the magnetic connectivity of Solar Orbiter.

Slow solar wind↗

Application of Magnetic Resonance Imaging and Three-Dimensional Treatment Planning in the Treatment of Orbital Lymphoma

Radiotherapy for lymphoma of the orbit must be individualized for each patient and clinical setting. Most techniques focus on optimizing the dose to the tumor while sparing the lens. This study describes a technique utilizing magnetic resonance imaging (MRI) and three dimensional (3D) planning in the treatment of orbital lymphoma. A patient presented with an intermediate grade lymphoma of the right orbit. The prescribed tumor dose was 4050 cGy in 18 fractions. Three D planning was carried out and tumor volumes, retina, and lens were subsequently outlined. Dose calculations including dose volume histograms of the target, retina, and lens were then performed. Part of the retina was outside of the treatment volume while 50% of the retina received 90% or more of the prescribed dose. The patient was clinically NED when last seen 2 years following therapy with no treatment-related morbidity. Patients with lymphomas of the orbit can be optimally treated using MRI based 3D treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Lessons Learned from the Clean Energy to Communities (C2C) Peer-Learning Cohort Evaluating and Prioritizing Municipal Buildings for Energy Efficiency and Decarbonization Investment

The National Renewable Energy Laboratory (NREL), with support from World Resources Institute (WRI), designed and led a six-month peer-learning cohort from January through July 2024 on "Enhancing Resilience at Critical Facilities through Solar, Storage, and Microgrids" as part of the U.S Department of Energy's Clean Energy to Communities (nrel.gov/c2c) (C2C) program. Representatives from 15 municipalities, municipal utilities, colleges, and Tribes from across the United States participated in monthly workshops covering best practices for planning and deploying local resilience projects. This document shares key takeaways, lessons learned, and resources from the cohort.

buildings↗

Capabilities Development: From International Space Station and the Moon to Mars

The President of the United States, in signing Space Policy Directive-1, directed the NASA Administrator “to lead an innovative and sustainable program of exploration with commercial and international partners to enable human expansion across the solar system and to bring back to Earth new knowledge and opportunities. Beginning with missions beyond low-Earth orbit (LEO), the United States will lead the return of humans to the Moon for long-term exploration and utilization, followed by human missions to Mars and other destinations.” NASA is charged to land American astronauts on the lunar South Pole in 2024 and to continue a campaign of sustainable lunar surface exploration in order to develop necessary technologies and capabilities to enable initial human missions to Mars. NASA’s lunar surface exploration plans are part of a continuum of activities utilizing platforms in low Earth orbit (LEO), cislunar space, and the lunar surface to demonstrate advanced technologies, advance operations concepts, and develop countermeasures to lessen the impacts of the space environment and long duration exposure on the crew working in space. NASA is using a capability-driven approach to identify critical gaps to be addressed as part of a focused program to reduce risk for future deep space exploration missions building to eventual human missions to the surface of Mars. Teams of discipline experts from across NASA identify capability gaps between the current state of the art and the needs of proposed exploration missions and develop integrated strategies and roadmaps for filling those gaps. These inputs include assessment of platform needs for demonstration and testing of new capabilities. Generally, the International Space Station (ISS) and Gateway are needed for demonstration of capabilities for Mars transit, while Lunar surface activities focus on development of capabilities and operational protocols for Mars surface. This paper discusses the activities required to advance critical exploration capabilities, focusing on selection of demonstration and test location based upon the unique environments and characteristics of the ISS, Gateway, and potential lunar surface assets. The optimal strategy will be a combination of ISS/LEO, Gateway, and lunar surface testing; however, not all capabilities require a deep space exploration missions.

Boggs, Kathleen Gallagher↗

An overview of large wind turbine tests by electric utilities

A summary of recent plants and experiences on current large wind turbine (WT) tests being conducted by electric utilities is provided. The test programs discussed do not include federal research and development (R&D) programs, many of which are also being conducted in conjunction with electric utilities. The information presented is being assembled in a project, funded by the Electric Power Research Institute (EPRI), the objective of which is to provide electric utilities with timely summaries of test performance on key large wind turbines. A summary of key tests, test instrumentation, and recent results and plans is given. During the past year, many of the utility test programs initiated have encountered test difficulties that required specific WT design changes. However, test results to date continue to indicate that long-term machine performance and cost-effectiveness are achievable.

Vachon, W. A.↗

TU-AB-201-01: A Comprehensive Planning Comparison Study Between a Novel Direction Modulated Brachytherapy Tandem Applicator and Conventional T&R Applicator for Image Guided Cervical Cancer Brachytherapy

Purpose: To demonstrate that utilization of a novel, intensity modulation capable, direction modulated brachytherapy (DMBT) tandem applicator can improve plan quality compared with conventional T&R applicator during an image guided cervical cancer brachytherapy. Methods: 45 cervical cancer patients treated with PDR brachytherapy were reviewed. Of them, a) 27 were treated using T&R only, b) 9 were treated using T&R with needles attached to the ring, and c) the remaining 9 were treated using T&R with needles attached to the ring (AN) as well as additional free-hand-loaded needles (FN). The DMBT tandem design has 6 peripheral holes of 1.3-mm diameter, grooved along a nonmagnetic tungsten alloy rod, enclosed in a plastic sheath with total 6.0-mm diameter. An in-house-coded inverse planning system was used for planning DMBT and T&R cases. All typical clinical constraints including OAR dose limits, dwell times, and loading patterns were respected. For the DMBT and T&R applicators, the plans were optimized with the same conventional ring in place, but repeatedly planned with and without AN/FN needles. All generated plans were normalized to the same D90 of the clinically treated plans. Results: For the plans in category a), DMBT generally outperformed T&R with average reduction in D2cc of −2.39%, −5.21%, and −2.69% for bladder, rectum, and sigmoid, respectively. For the plans in category b) and c), DMBT generally outperformed T&R if the same needles in AN/FN were utilized in both cases with average reduction in D2cc of −1.82%, −3.40%, and −6.04%, respectively. For the cases where the needles were not utilized for both applicators, an average D2cc reduction of −7.45%, −7.61%, and 17.47% were observed, respectively. Conclusions: Under the same clinical conditions, with/without needles, the DMBT applicator tends to generate more favorable plans compared with the conventional T&R applicator, and hence, is a promising technology.

60 APPLIED LIFE SCIENCES↗

The past, present, and future of peaking thermal power plants in the United States

Today's power systems rely on "peaker plants" to reliably serve load during peak demand periods. In this study we consider the present competitiveness of different peaking options, how much and what kinds of plants have provided U.S. peaking capacity, and potential future peaking fleet compositions. We explore how capital intensity impacts the breakeven capacity factor between two potential resources: combustion turbines (CTs) and combined cycle plants (CCs). CTs outcompete CCs below 12%-17% annual capacity factor at today's prices, but can shift with changes to fuel or start costs. Historically, gas CTs and petroleum steam plants most closely fit the role of peakers. Peaking capacity could grow from approximately 280 GW today to 460-770 GW in 2050 composed of a wider range of resources. We conclude by discussing implications of this shift, with a focus on the potential planning considerations for shifting to a greater utilization of CCs for peaking needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The impact of market design and clean energy incentives on strategic generation investments and resource adequacy in low-carbon electricity markets

Well-designed electricity markets play a crucial role in maintaining reliable electric power systems, which are critical in modern society. Here, this study examines the impact of different electricity market designs and clean energy incentive schemes on supporting renewable energy integration and achieving clean energy goals. To this end, we utilize a game-theoretical generation expansion planning model where generation companies make investment and retirement decisions to maximize their expected profit. The model is structured as an equilibrium problem with equilibrium constraints (EPEC) and solved using a diagonalization approach combined with progressive hedging. We analyze three types of electricity market designs: an energy-only market, a capacity market, and a clean energy market, and consider a wide range of market parameters resulting in 14 total scenarios. Wind and solar capacity comprise the majority of new investments in all considered scenarios, but the resultant system planning reserve margin (PRM) can differ significantly depending on market parameters. We also find that profit-driven investments lead to lower PRMs than a traditional system cost minimization approach. These individual scenario results further demonstrate how different market designs and clean energy incentive schemes may influence investor decision-making and impact resource adequacy throughout the clean energy transition.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Decay Dose Shielding Analysis with Hybrid Unstructured Mesh/Constructive Solid Geometry Monte Carlo Calculation and ADVANTG Acceleration

Here, the target segments of the Oak Ridge National Laboratory Second Target Station (STS) neutron production facility become highly activated due to spallation reactions or nuclei transmutation by primary protons and emitted neutrons. Once the target segments are removed from their location within the core vessel, decay dose rates must be accurately quantified to determine the shielding configurations of remote-handling tools and transport casks and to aid in planning maintenance activities. For this analysis, we utilized a hybrid unstructured mesh (UM)/constructive solid geometry approach for calculating spallation products and neutron fluxes, activation calculations using the AARE package that includes the CINDER2008 activation code to calculate the decay photon source at different cooling times, and the ADVANTG code to accelerate the final decay photon transport calculation. Both Type 316 stainless steel (SS-316) and lead were investigated as candidates for shielding materials. The decay photon transport calculation through the thick SS-316 or lead shields exhibited between 25 and 30 orders-of-magnitude attenuations in the radial direction, depending on the shield. Such a difficult shielding calculation required advanced variance reduction. ADVANTG has some missing features, which limits its usability in spallation neutron source applications. It does not support volumetric sources created for MCNP6.2 UM capability. An approximate source was created for this problem. Not only was this approximate source needed for running the ADVANTG calculation to generate the weight windows, but also it was essential to develop source biasing (SB) parameters that were crucial for dramatically accelerating the decay photon transport in this problem. With this approximate source, the analysis was completed in a very reasonable computational time, and the design of the STS remote-handling equipment was finalized. This paper compares the efficiency of Monte Carlo simulations with different weight window and SB parameters calculated using different approximate ADVANTG calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Techno-Economic Analysis of BEVs with Fast Charging Infrastructure: Preprint

Battery electric vehicles (BEVs) offer the potential to reduce both oil imports and greenhouse gas emissions, but high upfront costs, battery-limited vehicle range, and concern over high battery replacement costs may discourage many potential purchasers. One proposed solution is to employ a subscription model under which a service provider assumes ownership of the battery while providing access to vast fast charging infrastructure. Thus, high upfront and subsequent battery replacement costs are replaced by a predictable monthly fee, and battery-limited range is replaced by a larger infrastructure-limited range. Assessing the costs and benefits of such a proposal are complicated by many factors, including customer drive patterns, the amount of required infrastructure, and battery life. Herein the National Renewable Energy Laboratory applies its Battery Ownership Model to address these challenges and compare the economics and utility of a BEV fast charging service plan to a traditional direct ownership option. In single vehicle households, where such a service is most valuable, we find that operating a BEV under a fast charge service plan can be more cost-effective than direct ownership of a BEV, but it is rarely more cost-effective than direct ownership of a conventional vehicle.

25 ENERGY STORAGE↗

TH-AB-BRB-00: Research Opportunities with Digital Linear Accelerators

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-01: Trajectory Modulated Arc Therapy: Application to Partial Breast Irradiation

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-02: ET-Reloaded

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-03: 4n Radiotherapy

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-04: Quality Assurance for Advanced Digital Linac Implementations

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-05: Using a Research Real-Time Control Interface to Go Beyond Dynamic MLC Tracking

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

GRAF-Plan for Vietnam

Evaluates the reserve requirements for power system balancing areas based on variability and uncertainty of load as well as wind and solar generation scenarios. The tool uses minute‐by‐minute site‐specific generation and load information, as well as information from generation and load forecasting algorithms used in the balancing areas. The Balancing‐Plan Tool can be used directly by utility planners and operators to aid in the integration of intermittent renewable resources. The tool provides reserve requirements of various kinds, such as day‐ahead, load following and regulation, as well as estimates the capacity of the generation fleet to provide the require reserves.

Campbell, Allison↗

Impact Mapping for Geospatial Reasoning and Decision Making

Objective The reported study evaluated a novel approach to aiding geospatial reasoning and decision making. Background Impact mapping aims to alleviate the cognitive demands of geospatial tasks in part by externalizing data in the form of an integrated decision surface. This is achieved by aggregating data across multiple sources of information and visualizing their combined utility rather than objective measurements or individual utility. Previous research has shown that geospatial decisions improve when aided in this manner, but it remains unknown if dynamic decision making, often plagued by fatigue and anchoring bias, would benefit similarly. Method The experiment implemented a systematic manipulation of the presence of a composite impact map and the number of attributes present in a two-stage disaster relief, resource allocation task to investigate when and how impact mapping is beneficial or deleterious to decision makers. Results The presence of the composite impact map increased the utility of selected sites, increased re-planning decisions, reduced information display views, and reduced workload. Generally, the effect of the composite impact map was greater when participants were asked to evaluate more attributes. Conclusion Composite impact maps appear to improve repeated geospatial reasoning and minimize anchoring bias because they alleviate the cognitive demands otherwise necessary to interpret and maintain information from multiple attributes. Application Data visualization techniques, such as impact mapping, can improve repeated geospatial decision making in environments that include high cognitive demand.

Illingworth, David A.↗