Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “unit testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

NETL Direct Air Capture Center

In 2022 Congress authorized the $25M National Energy Technology Laboratory Direct Air Capture Center. The facility will be specifically targeted at accelerating the commercialization of technologies beyond the conceptual stage which have not yet reached full pilot-scale (TRL 3 to 6). The ability to operate over a wide range of conditions will help the developers to understand how their technologies respond in different climates, from summer to winter and arid to tropical. NETL recognizes that DAC technology is still early in its evolution, and a wide variety of highly varied technologies are being explored. The Center will be designed with substantial flexibility to accommodate the rapidly evolving technological landscape. Testing systems at three scales will be included: lab-scale systems designed to examine the long-term stability of DAC materials, bench-scale module testing systems capable of probing flow dynamics, and small pilot-scale skid rooms able to test prototype DAC units under a wide variety of climate conditions. The NETL DAC Center will feature dedicated engineering, technician, scientific and logistical support for experimental system design, installation, operation of experiments, and interpretation of results for projects including but not limited to kinetics of absorption/desorption, thermal duty, and post-mortem elemental characterization to understand degradation. The NETL DAC Center projects will also have access to dedicated process modeling and analysis to evaluate the technoeconomic aspects of new technologies. NETL’s Systems Engineering and Analysis (SEA) team, the Carbon Capture Simulation Initiative (CCSI), and the Institute for the Design of Advanced Energy Systems (IDAES) are all potential collaborators with NETL’s testing partners from industry, academia, and other research institutions. NETL also has world class capabilities in device scale modeling (i.e., MFIX) that will be available to help design more efficient contactors and optimize unique internal configurations that can be realized by advanced manufacturing. The talk will cover the design and capabilities of the center, the planned availability, and feedback will be solicited from the audience on DAC testing needs.

Luebke, David↗

Accelerating commercialization of direct air capture technology

In 2022 Congress authorized the $25M National Energy Technology Laboratory Direct Air Capture Center. The facility will be specifically targeted at accelerating the commercialization of technologies beyond the conceptual stage which have not yet reached full pilot-scale (TRL 3 to 6). The ability to operate over a wide range of conditions will help the developers to understand how their technologies respond in different climates, from summer to winter and arid to tropical. NETL recognizes that DAC technology is still early in its evolution, and a wide variety of highly varied technologies are being explored. The Center will be designed with substantial flexibility to accommodate the rapidly evolving technological landscape. Testing systems at three scales will be included: lab-scale systems designed to examine the long-term stability of DAC materials, bench-scale module testing systems capable of probing flow dynamics, and small pilot-scale skid rooms able to test prototype DAC units under a wide variety of climate conditions. The NETL DAC Center will feature dedicated engineering, technician, scientific and logistical support for experimental system design, installation, operation of experiments, and interpretation of results for projects including but not limited to kinetics of absorption/desorption, thermal duty, and post-mortem elemental characterization to understand degradation. The NETL DAC Center projects will also have access to dedicated process modeling and analysis to evaluate the technoeconomic aspects of new technologies. NETL’s Systems Engineering and Analysis (SEA) team, the Carbon Capture Simulation Initiative (CCSI), and the Institute for the Design of Advanced Energy Systems (IDAES) are all potential collaborators with NETL’s testing partners from industry, academia, and other research institutions. NETL also has world class capabilities in device scale modeling (i.e., MFIX) that will be available to help design more efficient contactors and optimize unique internal configurations that can be realized by advanced manufacturing. The talk will cover the design and capabilities of the center, the planned availability, and feedback will be solicited from the audience on DAC testing needs.

Luebke, David↗

Advanced Stirling Convertor Dynamic Test Approach and Results

The U.S. Department of Energy (DOE), Lockheed Martin (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. As part of the extended operation testing of this power system, the Advanced Stirling Converters (ASC) at NASA John H. Glenn Research Center undergo a vibration test sequence intended to simulate the vibration history of an ASC used in an ASRG for a space mission. This sequence includes testing at Workmanship and Flight Acceptance levels interspersed with periods of extended operation to simulate pre and post fueling. The final step in the test sequence utilizes additional testing at Flight Acceptance levels to simulate launch. To better replicate the acceleration profile seen by an ASC incorporated into an ASRG, the input spectra used in testing the convertors was modified based on dynamic testing of the ASRG Engineering Unit ( ASRG-EU) at Lockheed Martin. This paper presents the vibration test plan for current and future ASC units, including the modified input spectra, and the results of recent tests using these spectra. The test results include data from several accelerometers mounted on the convertors as well as the piston position and output power variables.

Meer, David W.↗

Stockpile Stewardship and Nuclear Testing: A Technical Assessment

Since 1992, the United States has retained confidence in its nuclear weapon stockpile without performing any tests that produce nuclear yield. Instead, it has invested in a stockpile stewardship program (SSP) based on the same approach that was validated through fifty years of experience during the nuclear testing era. As the test moratorium continues and new information becomes available, it is both necessary and appropriate to periodically revisit the question of whether or not nuclear testing should resume. In a recent article by Dr. Mark Schneider, he asserts that the United States should return to nuclear testing to address the issues that negatively affect our country’s nuclear deterrent. A serious, technically informed evaluation of the most significant of the issues Dr. Schneider has raised is provided in this paper. The conclusion of this evaluation is that the strategy of a well-funded SSP coupled with rigorous assessments to identify if there is a specific need for a nuclear test is sound and cost-effective approach. Any decision otherwise needs to take into careful consideration all the classified SSP successes and data pertaining to the particular issues in question.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

NEAMS Thermal-Fluids Test Stand for Fluoride-Slat Cooled, High Temperature Reactor Development (Final CRADA Report)

The work performed in this CRADA resulted in significant progress toward the development of a Thermal-fluid test-stand based on NEAMS tools. Significant work has been achieved in this area with simulations performed in Nek5000 of the heat and fluid flow in twisted tube heat exchangers and various software and modeling improvements in SAM geared toward heat exchanger simulations. In particular a set of simulations of flow and heat transfer in twisted elliptical tube geometries has been performed with Nek5000. The method was validated by simulating a case at a moderate Reynolds number and relatively high Froude number. This case was demonstrated to predict a Nusselt number in excellent agreement with the applicable correlation found in literature. It was further shown that at lower Froude numbers, this agreement becomes much worse. Additional cases were then simulated with low Froude numbers for both a square and a triangular unit cell to test the effect of pitch-to-maximum diameter ratio for the purposes of future CFD modeling. The results have proven invaluable to understand the flow physics in twisted tubes and provide reference data for design. Results have been summarized in a conference article. Moreover, work in SAM has led to significant improvement of software quality, the creation of a set of benchmarks for natural circulation and other significant software improvement.

97 MATHEMATICS AND COMPUTING↗

OMC Compressor Case

This report summarizes efforts expended in the development of an all-composite compressor case. Two pre-production units have been built, one utilizing V-CAP and one utilizing AFR-700B resin systems. Both units have been rig tested at elevated temperatures well above design limit loads. This report discusses the manufacturing processes, test results, and Finite Element Analysis performed. The V-CAP unit was funded by NASA-Lewis Research Center in 1994 under contract number NAS3- 27442 for Development of an All-Composite OMC Compressor Case. This contract was followed by an Air Force study in 1996 to build and identical unit using the AFR-700B resin system in place of the V-CAP system. The second compressor case was funded under U.S. Air Force contract F33615-93-D-5326, Advanced Materials for Aerospace Structures Special Studies (AMAS3), Delivery Order 0021 entitled "Advanced Polymeric Composite Materials and Structures Technology for Advanced High Temperature Gas Turbine Engines.' Initial studies using the V-CAP resin system were undertaken in 1993 under a NASA Lewis contract (NAS3-26829). A first prototype unit was developed in a joint program between Textron-Lycoming (now Allied Signal) and Brunswick (now Lincoln Composites). This unit included composite end closures using low density, high temperature molded end closures. The units was similar in size and shape to a titanium case currently used on the PT-21 0 engine and was funded as part of the integrated High Performance Turbine Engine Technology (EHPTET) initiative of DOD and NASA.

Humphrey, W. Donald↗

Fission Surface Power System Initial Concept Definition

Under the NASA Exploration Technology Development Program (ETDP) and in partnership with the Department of Energy (DOE), NASA has embarked on a project to develop Fission Surface Power (FSP) technology. The primary goals of the project are to 1) develop FSP concepts that meet expected surface power requirements at reasonable cost with added benefits over other options, 2) establish a hardwarebased technical foundation for FSP design concepts and reduce overall development risk, 3) reduce the cost uncertainties for FSP and establish greater credibility for flight system cost estimates, and 4) generate the key products to allow NASA decision-makers to consider FSP as a preferred option for flight development. The FSP project was initiated in 2006 as the Prometheus Program and the Jupiter Icy Moons Orbiter (JIMO) mission were phased-out. As a first step, NASA Headquarters commissioned the Affordable Fission Surface Power System Study to evaluate the potential for an affordable FSP development approach. With a cost-effective FSP strategy identified, the FSP team evaluated design options and selected a Preliminary Reference Concept to guide technology development. Since then, the FSP Preliminary Reference Concept has served as a point-of-departure for several NASA mission architecture studies examining the use of nuclear power and has provided the foundation for a series of "Pathfinder" hardware tests. The long-term technology goal is a Technology Demonstration Unit (TDU) integrated system test using full-scale components and a non-nuclear reactor simulator. The FSP team consists of Glenn Research Center (GRC), Marshall Space Flight Center (MSFC) and the DOE National Laboratories at Los Alamos (LANL), Idaho (INL), Oak Ridge (ORNL), and Sandia (SNL). The project is organized into two main elements: Concept Definition and Risk Reduction. Under Concept Definition, the team performs trade studies, develops analytical tools, and formulates system concepts. Under Risk Reduction the team develops hardware prototypes and conducts laboratory-based testing.

Source record↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

How does drought affect residential water demand and price elasticity?

Urban water scarcity is an important social and economic concern, particularly as the intensity, duration, and frequency of droughts is increasing in many regions. We consider whether drought induces changes to water demand and the price elasticity of demand for water that may last beyond a drought’s official end date. If drought shocks prompt long-term changes in water demand behavior, and these changes occur at broad geographic scale, they could have important implications for modeling adaptive responses to water scarcity. We assemble a novel dataset on residential water demand and pricing in the western United States to test empirically for effects of drought on water demand and price elasticity. We perform our analysis with aggregate quantity, price, and drought data, accounting for endogenous prices under increasing-block water tariffs and using both average and marginal water fees in estimating water demand functions. Results are consistent with the hypothesis that households may become less price-sensitive after exposure to drought. However, we find no systematic evidence of long-run, drought-related reductions in water demand, itself.

demand hardening↗

Temperature of maximum density and excess thermodynamics of aqueous mixtures of methanol

In this work, we present a study of representative excess thermodynamic properties of aqueous mixtures of methanol over the complete concentration range, based on extensive computer simulation calculations. In addition to test various existing united atom model potentials, we have developed a new force-field which accurately reproduces the excess thermodynamics of this system. Moreover, we have paid particular attention to the behavior of the temperature of maximum density (TMD) in dilute methanol mixtures. The presence of a temperature of maximum density is one of the essential anomalies exhibited by water. This anomalous behavior is modified in a non-monotonous fashion by the presence of fully miscible solutes that partly disrupt the hydrogen bond network of water, such as methanol (and other short chain alcohols). In order to obtain a better insight into the phenomenology of the changes in the TMD of water induced by small amounts of methanol, we have performed a new series of experimental measurements and computer simulations using various force fields. We observe that none of the force-fields tested capture the non-monotonous concentration dependence of the TMD for highly diluted methanol solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Life Testing of the Hollow Cathode Plasma Contactor for the ProSEDS Mission

The Propulsive Small Expendable Deployer System (ProSEDS) mission is designed to provide an on-orbit demonstration of the electrodynamic propulsion capabilities of tethers in space. The ProSEDS experiment will be a secondary payload on a Delta 11 unmanned expendable booster. A 5-km conductive tether is attached to the Delta 11 second stage and collects current from the low Earth orbit (LEO) plasma. A hollow cathode plasma contactor emits the collected electrons from the Delta II, completing the electrical circuit with the ambient plasma. The current flowing through the tether generates thrust based on the Lorentz Force Law. The thrust will be generated opposite to the velocity vector, slowing down the spacecraft and causing it to de-orbit in approximately 14 days compared to the normal 6 months. A 10-km non-conductive tether is between the conductive tether and an endmass containing several scientific instruments. The ProSEDS mission lifetime was set at I day because most of the primary objectives can be met in that time. The extended ProSEDS mission will be for as many days as possible, until the Delta 11 second stage burns up or the tether is severed by a micrometeoroid or space debris particle. The Hollow Cathode Plasma Contactor (HCPC) unit has been designed for a 12-day mission. Because of the science requirements to measure the background ambient plasma, the HCPC must operate on a duty cycle. Later in the ProSEDS mission, the HCPC is operated in a manner to allow charging of the secondary battery. Due to the unusual operating requirements by the ProSEDS mission, a development unit of the HCPC was built for thorough testing. This developmental unit was tested for a simulated ProSEDS mission, with measurements of the ability to start and stop during the duty cycle. These tests also provided valuable data for the ProSEDS software requirements. Qualification tests of the HCPC flight hardware are also discussed.

Vaughn, Jason A.↗

Automated nuclear cloud feature extraction from film

Chemical, biological, radiological, nuclear, and explosives incidents require rapid detection and characterization for appropriate response. For a nuclear detonation, visible-light cameras may be used to locate the cloud and characterize fallout deposition when coupled with numerical models. Films from the United States’ nuclear testing era compose the only sizeable collection of imagery depicting high-yield detonations. These films offer unique insights into characteristics of flows involving scales that are difficult to replicate experimentally, and they are a valuable source of data for the validation of models for nuclear fallout transport, either as part of emergency response or forensic activities. In this work, we implement modern computer vision and machine learning techniques to identify and track the cloud automatically and subsequently determine the time dependence of some of its features. We trained a ResNet-18 image classifier on hundreds of images to categorize nuclear cloud morphology. Each category or cloud regime is determined by early cloud evolution and is associated to constitutive properties of the flow, such as distribution of vorticity. Next, we identified keypoint features using the KAZE algorithm and tracked these keypoints in the images, allowing us to determine the dimensions and velocities of the cloud across film frames. These measurements converted to real-world units provide valuable experimental data that can be used in the development and validation of nuclear cloud models. We compared the results of this method against manual cloud rise measurements from two different films. In one, our automated method accelerated the feature extraction process without sacrificing measurement accuracy.

Khristy, Joel [ORNL] (ORCID:0000000209963060)↗

Terrestrial Testing of the CapiBRIC, a Microgravity Optimized Brine Processor

Utilizing geometry based static phase separation exhibited in the radial vaned capillary drying tray, a system was conceived to recover water from brine. This technology has been named the Capillary BRIC; abbreviated CapiBRIC. The CapiBRIC utilizes a capillary drying tray within a drying chamber. Water is recovered from clean water vapor evaporating from the free surface leaving waste brine solids behind. A novel approach of optimizing the containment geometry to support passive capillary flow and static phase separation provides the opportunity for a low power system that is not as susceptible to fouling as membranes or other technologies employing physical barriers across the free brine surface to achieve phase separation in microgravity. Having been optimized for operation in microgravity, full-scale testing of the CapiBRIC as designed cannot be performed on the ground as the force of gravity would dominate over the capillary forces. However, subscale units relevant to full-scale design were used to characterize fill rates, containment stability, and interaction with a variable volume reservoir in the PSU Dryden Drop Tower (DDT) facility. PSU also using tested units scaled such that capillary forces dominated in a 1-g environment to characterize evaporation from a free-surface in 1-g upward, sideways and downward orientations. In order to augment the subscale testing performed by PSU, a full scale 1-g analogue of the CapiBRIC drying unit was initiated to help validate performance predictions regarding expected water recovery ratio, estimated processing time, and interface definitions for inlets, outlets, and internal processes, including vent gas composition. This paper describes the design, development and test of the terrestrial CapiBRIC prototypes.

Sargusingh, Miriam J.↗

A two-stage optical fusion framework for wildfire severity mapping across the conterminous United States

Accurate wildfire severity mapping (WSM) is essential for post-fire recovery planning, erosion risk assessment, ecosystem monitoring, and disaster risk reduction. Although Landsat and Sentinel optical imagery have been widely used for burn severity assessment, the added value of fusing multiple optical sensors has not been sufficiently quantified across diverse fire events, particularly since the launch of Landsat-9. This study evaluates whether multisensor optical fusion improves wildfire severity mapping relative to single-sensor baselines using Sentinel-2, Landsat-8, and Landsat-9 imagery across 40 wildfire events in the conterminous United States. We tested a two-stage fusion framework that combines feature-level fusion with pixel-level dimensionality reduction. First, feature-level fused datasets were created through early fusion by combining standardized post-fire bands from each sensor into a single predictor stack. Both raw reflectance bands and pairwise spectral transforms were retained to capture within- and cross-sensor spectral interactions. Second, Linear Discriminant Analysis was applied to both single-sensor and fused datasets to produce comparable low-dimensional feature spaces. Six machine-learning classifiers were then used to benchmark model performance with repeated spatially buffered train–test splits. Results show that Landsat-9 was the strongest single-sensor baseline. Among the fusion strategies, Sentinel-2 + Landsat-9 produced the most consistent improvement and reduced performance variability. Landscape-condition analysis further showed that this fusion was most beneficial in shrubland-dominated and high-terrain fires, where it achieved the highest overall mean accuracy and the fewest failures. In contrast, its benefits were less reliable in evergreen forests, mixed vegetation, and low- to moderate-elevation terrain. In operational settings, the Sentinel-2 + Landsat-9 configuration offers a practical solution for post-fire recovery planning, erosion-risk assessment, watershed management, and ecological monitoring when field observations are available and timely satellite-based information is needed.

Landsat↗

CRADA 376 Final Report Development of Protective Coatings for 1 kW Hot Zone

Pacific Northwest National Laboratory (PNNL) has extensive experience in the development, fabrication, and evaluation of surface treatments and protective coatings for metallic solid oxide fuel cell (SOFC) components. For example, modified (Mn,Co)3O4 spinel coatings and coating/metal interfaces have been shown to substantially improve oxidation resistance, electrical performance, and oxide scale adhesion of ferritic stainless steel interconnects in planar SOFC stacks. At the time of the establishment of this CRADA, Protonex Technology Corporation had been working in the field of SOFC development for over 12 years and had demonstrated more than 250 thermal cycles with a less than 15 minutes start time and more than 2000 hours of continuous operation on a 250W tubular solid oxide hot zone module as part of a program for the Office of the Secretary of Defense (OSD). An industrial version of the military system, denoted P200i, had been developed that was launched at the 2015 Fuel Cell Expo in Tokyo. Feedback during beta testing of this unit was very positive. However, Protonex recognized that to transition from military markets, the commercial system would require longer life time and higher power. Leveraging their novel thermal management strategy from the tubular hot zone that allowed for rapid and repeated thermal cycling, Protonex developed a planar 1kW module aimed at the industrial and commercial market. However, more robust interconnect coatings were needed to bring the system into the 1000+ hour life time requested by customers. Therefore, PNNL’s experience and technology were engaged to enable the 1kw system to transition from military applications to commercial and industrial applications. In this CRADA, PNNL teamed with Protonex to leverage PNNL’s expertise in protective coating techniques for solid oxide fuel cell (SOFC) applications. As the first step in the collaboration, protective spinel coatings were fabricated at PNNL onto ten AISI 440 stainless steel bus bars provided by Protonex. A precursor slurry containing spinel powder was applied to the steel surfaces via an ultrasonic spray process. The coated bars were then subjected to a reducing atmosphere heat treatment (i.e., heated to 850°C at 3°C/min in a hydrogen atmosphere and held at that temperature for five hours). Five of the bars were left in this reduced condition; the other five bars were subjected to an oxidizing heat treatment (i.e., heated to 1000°C at 3°C/min in air and held at that temperature for one hour). The bars were then sent to Protonex for testing. Subsequently, Protonex decided to discontinue their SOFC development activities, so they had no further interest in continuing the collaboration with PNNL, and the CRADA activities were terminated.

30 DIRECT ENERGY CONVERSION↗

Testing of graphite thermal neutron scattering law data in support of treat neutronic analysis

The Transient Reactor Test Facility (TREAT) has historically provided the capability for transient fuel performance and safety testing in the United States. The operation of this facility was suspended in 1994. However, in recent years preparations for the restart of TREAT were initiated. TREAT is a graphite moderated and air cooled reactor. Its core is composed of a 19 x 19 array of fuel assemblies that contain UO{sub 2} (HEU) fuel particles dispersed in a graphite matrix, along with reflector assemblies filled with graphite only. Each fuel assembly is 8 feet tall with a fueled region that is 4 feet tall and upper and lower regions of graphite that are 2 feet tall. In addition, a 2 feet thick radial graphite reflector region is present. Finally, a 5 feet thick concrete biological shield surrounds the core. Previous work showed that the graphite thermal scattering cross sections can introduce variations exceeding 2000 pcm in the predicted eigenvalue of the TREAT core. Recognizing that the graphite in the assembly (and thereby the core) is a porous mixture of crystalline and amorphous carbon (with a lower density in comparison to ideal crystalline graphite), it becomes clear that TREAT specific thermal neutron scattering cross section libraries will be needed (at all temperatures of interest) for use within neutronic codes seeking to simulate TREAT. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Off-line Tests of the DM1200 Thermal Catalytic Oxidation (TCO) Unit (Final Report)

The River Protection Project-Waste Treatment Plant (RPP-WTP) Low-Activity Waste (LAW) and High-Level Waste (HLW) feed streams are listed for a variety of hazardous organic compounds. The permitting basis for the WTP systems may necessitate the demonstration of minimum Destruction/Removal Efficiencies (DREs) of such species from any released emissions of up to 99.99%. Results from a previous study on the fate of hazardous organics in the melter itself indicated, not only that DREs for selected test compounds approached 99.99% only at extreme melter conditions, but also that organic compounds not originally present in the feed were actually produced in the melter, In order to ensure that the required DREs for hazardous organics are met, Thermal Catalytic Oxidation (TCO) units were therefore added to both the HLW and LAW off-gas treatment systems, The extent to which these species can be destroyed or removed in the TCO units is therefore an important issue in the design and permitting of the LAW and HLW off-gas treatment systems. A further consideration is that it would be desirable, if possible, to be able to achieve all of the required DRE across the TCO alone. If that is not the case, the DRE would be distributed across several unit operations, which may then become subject to additional operational constraints that may reduce process flexibility. Compliance with the DRE requirements on the basis of the TCO unit alone is also an approach that lends itself to periodic confirmation during operations, since the TCO is located at the back-end of the off-gas treatment system where radioactivity levels are lowest.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrective Action Decision Document/Corrective Action Plan for Corrective Action Unit 414: Clean Slate III Plutonium Dispersion (TTR) Tonopah Test Range, Nevada, Revision 1

This Corrective Action Decision Document/Corrective Action Plan provides the rationale and supporting information for the selection and implementation of corrective actions at Corrective Action Unit (CAU) 414, Clean Slate III Plutonium Dispersion (TTR). This document has been developed in accordance with the Federal Facility Agreement and Consent Order. CAU 414 is located on the Tonopah Test Range and includes one corrective action site, TA-23-03CS, Pu Contaminated Soil.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗