Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tracking errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Implementation of Material and Geometry Criticality Search in RMC Code

RMC is a continuous-energy Reactor Monte Carlo neutron and photon transport code being developed by Department of Engineering Physics at Tsinghua University, Beijing. For the use of simulation of reactor control or design of reactor with unknown material and geometry parameters, an accurate and efficient method of eigenvalue search is implemented in RMC code. The eigenvalue search focuses on two types of parameters. One is nuclide atom density, called material search, which includes the fuel density, enrichment or boron concentration. Perturbation theory of Monte Carlo Code, like differential operator method and adjoint-weighted perturbation method has been widely researched in sensitivity and uncertainty study. For material search, the perturbation algorithm needs to coupled with flexible material control block and optimized strategy. The other type of parameter is surface position, called geometry search, which includes fuel rod diameter, pitch and control rod position. MC21 iterated on surface position based on bisection method or regula-falsi method, and directly recalculated k-eff until it converged to target error interval. In this paper, the differential operator method, improved Newton-Raphson method is introduced. Based on these methods, the global material search is implemented. Then based on material search and finite method, global geometry search is implement. Finally, fuel enrichment, boron concentration and control rod position in normal PWR assembly are searched. The results show that RMC can search material and geometry parameters accurately and efficiently. In this paper, global eigenvalue search of material and geometry parameters have been implemented in RMC code. They are based on the differential operator method in Monte Carlo perturbation theory. The differential operator method samples δk/δρ{sub r}, δ{sup 2}k/δρ{sub r}{sup 2} along with k-eff estimator. Therefore it won't take up too much additional computational resource. For homogeneous material search, fission source effect has little effect of accuracy and can be ignored. The results of fuel enrichment and boron concentration searches in assembly show that improved Newton-Raphson method can iterate efficiently until k-eff is in the error interval. Based on material search and finite difference formula, the geometry parameter, like control rod axial position, can iterate until k-eff is in the error interval. However, the tiny perturbed region may not contain enough tracks to simulate. Besides, the large number density's relative change up to -1 may cause underestimation of Δk-eff, and then slope of k-x curve. This will cause non-convergence for Newton- Raphson method. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Opening the reheating box in multifield inflation

The robustness of multi-field inflation to the physics of reheating is investigated. In order to carry out this study, reheating is described in detail by means of a formalism which tracks the evolution of scalar fields and perfect fluids in interaction (the inflatons and their decay products). This framework is then used to establish the general equations of motion of the background and perturbative quantities controlling the evolution of the system during reheating. Next, these equations are solved exactly by means of a new numerical code. Moreover, new analytical techniques, allowing us to interpret and approximate these solutions, are developed. As an illustration of a physical prediction that could be affected by the micro-physics of reheating, the amplitude of non-adiabatic perturbations in double inflation is considered. It is found that ignoring the fine-structure of reheating, as usually done in the standard approach, can lead to differences as big as ~ 50%, while our semi-analytic estimates can reduce this error to ~ 10%. Finally, we conclude that, in multi-field inflation, tracking the perturbations through the details of the reheating process is important and, to achieve good precision, requires the use of numerical calculations.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical Navigation for Autonomous Approach of Small Unknown Bodies

State of the practice in navigation around small celestial bodies heavily relies on ground sup- port and human skill, in particular, for perception-based operations such as optical navigation and mapping. This leads to longer duration and more complex mission operations and sub- sequently higher cost. Furthermore, it imposes limitations for certain missions such as fast fly-bys or multi-agent operations. In this work, we present an autonomous navigation strat- egy suitable for approaching small unexplored bodies. During the approach, we estimate the body’s physical properties as well as the spacecraft’s relative trajectory and associated un- certainties. The autonomous navigation strategy, which is solely based on optical measure- ments, begins as soon as the body becomes resolved in the navigation camera and terminates at the start of proximity operations, when the spacecraft makes its first trajectory correction to stay in the vicinity of the body. Our strategy uses multiple image-processing algorithms: light-curve analysis for estimating the target body’s rotation rate, Shape-from-Silhouette for reconstructing the 3D shape and estimating its rotation pole, and feature tracking tailored to Small-Body images for estimating relative navigation parameters. We used the Mission Analysis, Operations, and Navigation Toolkit Environment (MONTE) developed by the Jet Propulsion Laboratory to evaluate the feasibility of this multi-phase navigation strategy using simulated images of an approach trajectory. We used the Rosetta mission data to generate photorealistic images to characterise the performance of this approach. This work is based on the assumptions that the spacecraft attitude is known, the body is a principal-axis rotator, a-priori estimates of ephemerides and scale are available, and the body is observed from a zero sun phase only during initial approach. Preliminary results show orbit determination performance that is on par with the human navigation from the Rosetta mission; albeit with a 1% bias in spacecraft-target radial distance estimate. The bias error is likely due to the robustness and accuracy of the visual tracking under dynamic lighting conditions and per- spective changes, which decrease accuracy.

Villa, Jacopo↗

Limiter-aware adaptive excitation control for hydropower generators with legacy voltage regulation systems

Hydropower units often rely on legacy excitation systems with fixed automatic voltage regulator (AVR) settings, but parameter drift, changing operating conditions, and evolving grid-service demands can degrade terminal-voltage regulation over time. This problem should be addressed because poor voltage regulation affects reactive-power support, system stability, and reliable plant operation, and replacing installed AVR and limiter logic is costly and disruptive in practice. To address this issue, this paper proposes a retrofit-friendly enhancement for hydropower generator excitation systems that combines adaptive tuning of the AVR middle lead–lag branch with a small proportional-integral correction for removing steady bias and slow drift. The adaptive laws are normalized, projection-bounded, and equipped with leakage, while adaptation is enabled only in the middle branch. Thus, the intent of the underexcitation and overexcitation limiters, as well as legacy current and rate limits, remains unchanged. Stability is analyzed under incremental performance assumptions, yielding boundedness and asymptotic tracking in the absence of saturation. The method is evaluated using real operational data from a utility-scale hydropower unit at Rocky Reach Dam, Unit C-8. Compared with the fixed AVR baseline, the proposed method reduces terminal-voltage mean squared error by about 70%, removes long periods of steady-state bias, and improves transient tracking while coexisting with limiter actions. These results show that substantial voltage-control improvement can be achieved on existing hydropower units with minimal integration effort and without replacing the installed AVR structure.

ESST5B model↗

SU-E-J-118: Verification of Intrafractional Positional Accuracy Using Ultrasound Autoscan Tracking for Prostate Cancer Treatment

Purpose: Transperineal ultrasound imaging is attractive option for imageguided radiation therapy as there is no need to implant fiducials, no extra imaging dose, and real time continuous imaging is possible during treatment. The aim of this study is to verify the tracking accuracy of a commercial ultrasound system under treatment conditions with a male pelvic phantom. Methods: A CT and ultrasound scan were acquired for the male pelvic phantom. The phantom was then placed in a treatment mimicking position on a motion platform. The axial and lateral tracking accuracy of the ultrasound system were verified using an independent optical tracking system. The tracking accuracy was evaluated by tracking the phantom position detected by the ultrasound system, and comparing it to the optical tracking system under the conditions of beam on (15 MV), beam off, poor image quality with an acoustic shadow introduced, and different phantom motion cycles (10 and 20 second periods). Additionally, the time lag between the ultrasound-detected and actual phantom motion was investigated. Results: Displacement amplitudes reported by the ultrasound system and optical system were within 0.5 mm of each other for both directions and all conditions. The ultrasound tracking performance in axial direction was better than in lateral direction. Radiation did not interfere with ultrasound tracking while image quality affected tracking accuracy. The tracking accuracy was better for periodic motion with 20 second period. The time delay between the ultrasound tracking system and the phantom motion was clinically acceptable. Conclusion: Intrafractional prostate motion is a potential source of treatment error especially in the context of emerging SBRT regimens. It is feasible to use transperineal ultrasound daily to monitor prostate motion during treatment. Our results verify the tracking accuracy of a commercial ultrasound system to be better than 1 mm under typical external beam treatment conditions.

60 APPLIED LIFE SCIENCES↗

Measurement of CPAS Main Parachute Rate of Descent

The Crew Exploration Vehicle Parachute Assembly System (CPAS) is being designed to land the Orion Crew Module (CM) at a safe rate of descent at splashdown. Flight test performance must be measured to a high degree of accuracy to ensure this requirement is met with the most efficient design possible. Although the design includes three CPAS Main parachutes, the requirement is that the system must not exceed 33 ft/s under two Main parachutes, should one of the Main parachutes fail. Therefore, several tests were conducted with clusters of two Mains. All of the steady-state rate of descent data are normalized to standard sea level conditions and checked against the limit. As the Orion design gains weight, the system is approaching this limit to within measurement precision. Parachute "breathing," cluster interactions, and atmospheric anomalies can cause the rate of descent to vary widely and lead to challenges in characterizing parachute terminal performance. An early test had contradictory rate of descent results from optical trajectory and Differential Global Positioning Systems (DGPS). A thorough analysis of the data sources and error propagation was conducted to determine the uncertainty in the trajectory. It was discovered that the Time Space Position Information (TSPI) from the optical tracking provided accurate position data. However, the velocity from TPSI must be computed via numerical differentiation, which is prone to large error. DGPS obtains position through pseudo-range calculations from multiple satellites and velocity through Doppler shift of the carrier frequency. Because the velocity from DGPS is a direct measurement, it is more accurate than TSPI velocity. To remedy the situation, a commercial off-the-shelf product that combines GPS and an Inertial Measurement Unit (IMU) was purchased to significantly improve rate of descent measurements. This had the added benefit of solving GPS dropouts during aircraft extraction. Statistical probability distributions for CPAS Main parachute rate of descent and drag coefficient were computed and plotted. Using test data, a terminal rate of descent at splashdown can be estimated as a function of canopy loading.

Ray, Eric S.↗

Atmospheric Limitations to Repeat-Track Radar Interferometry

In a recent mission, the Shuttle Imaging Radar (SIR-C) satellite devoted three days to repeat-track interferometry. The data was analyzed from a test site in the Mojave desert of California. Although good topography was obtained, most of the error was caused by turbulent water vapor in the lower atmosphere. Analysis of the effects of water vapor on multiple-track interferometry is given.

shuttle↗

Altimeter error sources at the 10-cm performance level

Error sources affecting the calibration and operational use of a 10 cm altimeter are examined to determine the magnitudes of current errors and the investigations necessary to reduce them to acceptable bounds. Errors considered include those affecting operational data pre-processing, and those affecting altitude bias determination, with error budgets developed for both. The most significant error sources affecting pre-processing are bias calibration, propagation corrections for the ionosphere, and measurement noise. No ionospheric models are currently validated at the required 10-25% accuracy level. The optimum smoothing to reduce the effects of measurement noise is investigated and found to be on the order of one second, based on the TASC model of geoid undulations. The 10 cm calibrations are found to be feasible only through the use of altimeter passes that are very high elevation for a tracking station which tracks very close to the time of altimeter track, such as a high elevation pass across the island of Bermuda. By far the largest error source, based on the current state-of-the-art, is the location of the island tracking station relative to mean sea level in the surrounding ocean areas.

Martin, C. F.↗

Technical Note: Millimeter precision in ultrasound based patient positioning: Experimental quantification of inherent technical limitations

Purpose: To identify the relevant technical sources of error of a system based on three-dimensional ultrasound (3D US) for patient positioning in external beam radiotherapy. To quantify these sources of error in a controlled laboratory setting. To estimate the resulting end-to-end geometric precision of the intramodality protocol. Methods: Two identical free-hand 3D US systems at both the planning-CT and the treatment room were calibrated to the laboratory frame of reference. Every step of the calibration chain was repeated multiple times to estimate its contribution to overall systematic and random error. Optimal margins were computed given the identified and quantified systematic and random errors. Results: In descending order of magnitude, the identified and quantified sources of error were: alignment of calibration phantom to laser marks 0.78 mm, alignment of lasers in treatment vs planning room 0.51 mm, calibration and tracking of 3D US probe 0.49 mm, alignment of stereoscopic infrared camera to calibration phantom 0.03 mm. Under ideal laboratory conditions, these errors are expected to limit ultrasound-based positioning to an accuracy of 1.05 mm radially. Conclusions: The investigated 3D ultrasound system achieves an intramodal accuracy of about 1 mm radially in a controlled laboratory setting. The identified systematic and random errors require an optimal clinical tumor volume to planning target volume margin of about 3 mm. These inherent technical limitations do not prevent clinical use, including hypofractionation or stereotactic body radiation therapy.

60 APPLIED LIFE SCIENCES↗

Time determination for spacecraft users of the Navstar Global Positioning System /GPS/

Global Positioning System (GPS) navigation is performed by time measurements. A description is presented of a two body model of spacecraft motion. Orbit determination is the process of inferring the position, velocity, and clock offset of the user from measurements made of the user motion in the Newtonian coordinate system. To illustrate the effect of clock errors and the accuracy with which the user spacecraft time and orbit may be determined, a low-earth-orbit spacecraft (Seasat) as tracked by six Phase I GPS space vehicles is considered. The obtained results indicate that in the absence of unmodeled dynamic parameter errors clock biases may be determined to the nanosecond level. There is, however, a high correlation between the clock bias and the uncertainty in the gravitational parameter GM, i.e., the product of the universal gravitational constant and the total mass of the earth. It is, therefore, not possible to determine clock bias to better than 25 nanosecond accuracy in the presence of a gravitational error of one part per million.

Grenchik, T. J.↗

On-Track Measurement of Road Load Changes in Two Close-Following Vehicles: Methods and Results

As emerging automated vehicle technology is making advances in safety and reliability, engineers are also exploring improvements in energy efficiency with this new paradigm. Powertrain efficiency receives due attention, but also impactful is finding ways to reduce driving losses in coordinated-driving scenarios. Efforts focused on simulation to quantify road load improvements require a sufficient amount of background validation work to support them. This study uses a practical approach to directly quantify road load changes by testing the coordinated driving of two vehicles on a test track at various speeds (64, 88, 113 km/h) and vehicle time gaps (0.3 to 1.3 s). Axle torque sensors were used to directly measure the load required to maintain steady-state speeds while following a lead vehicle at various gap distances. Through trial and error, test methods were developed that appear to provide satisfactory results, considering the challenges of track testing under real-world conditions (wind, weather, temperature changes, etc.). We found that total road load was reduced by about 10-12% at an optimum gap time of 0.25 to 0.4 s. Challenges that were encountered included less repeatability of load measurements at short gap distances and powertrain mode switching (from a hybrid vehicle) that rendered the 88-km/h results less useful. This study will provide the framework for further investigations on coordinated-driving road load using track testing methods.

Duoba, Michael↗

Demonstration of an AI-driven workflow for dynamic x-ray spectroscopy

X-ray absorption near edge structure (XANES) spectroscopy is a powerful technique for characterizing the chemical state and symmetry of individual elements within materials, but requires collecting data at many energy points which can be time-consuming. While adaptive sampling methods exist for efficiently collecting spectroscopic data, they often lack domain-specific knowledge about the structure of XANES spectra. Here we demonstrate a knowledge-injected Bayesian optimization approach for adaptive XANES data collection that incorporates understanding of spectral features like absorption edges and pre-edge peaks. We show this method accurately reconstructs the absorption edge of XANES spectra using only 15–20% of the measurement points typically needed for conventional sampling, while maintaining the ability to determine the x-ray energy of the sharp peak after the absorption edge with errors less than 0.03 eV, the absorption edge with errors less than 0.1 eV; and overall root-mean-square errors less than 0.005 compared to traditionally sampled spectra. Our experiments on battery materials and catalysts demonstrate the method’s effectiveness for both static and dynamic XANES measurements, improving data collection efficiency and enabling better time resolution for tracking chemical changes. This approach advances the degree of automation in XANES experiments, reducing the common errors of under- or over-sampling points near the absorption edge and enabling dynamic experiments that require high temporal resolution or limited measurement time.

Bayesian optimization↗

Remote Distributed Vibration Sensing Through Opaque Media Using Permanent Magnets

Vibration sensing is critical for a variety of applications from structural fatigue monitoring to understanding the modes of airplane wings. In particular, remote sensing techniques are needed for measuring the vibrations of multiple points simultaneously, assessing vibrations inside opaque metal vessels, and sensing through smoke clouds and other optically challenging environments. Here, in this paper, we propose a method which measures high-frequency displacements remotely using changes in the magnetic field generated by permanent magnets. We leverage the unique nature of vibration tracking and use a calibrated local model technique developed specifically to improve the frequency-domain estimation accuracy. The results show that two-dimensional local models surpass the dipole model in tracking high-frequency motions. A theoretical basis for understanding the effects of electronic noise and error due to correlated variables is generated in order to predict the performance of experiments prior to implementation. Simultaneous measurements of up to three independent vibrating components are shown. The relative accuracy of the magnet-based displacement tracking with respect to the video tracking ranges from 40 to 190 μm when the maximum displacements approach ±5 mm and when sensor-to-magnet distances vary from 25 to 36 mm. Finally, vibration sensing inside an opaque metal vessel and mode shape changes due to damage on an aluminum beam are also studied using the wireless permanent-magnet vibration sensing scheme.

42 ENGINEERING↗

Two novel automatic frequency tracking loops

Two automatic-frequency-control (AFC) loops are introduced and analyzed in detail. The algorithms are generalizations of the well known cross-product AFC loop with improved performance. The first estimator uses running overlapping discrete Fourier transforms to create a discriminator curve proportional to the frequency estimation error, whereas the second one preprocesses the received data and then uses an extended Kalman filter to estimate the input frequency. The algorithms are tested by computer simulations in a highly dynamic environment at low carrier/noise ratio (CNR). The algorithms are suboptimum tracking schemes with a larger frequency-error variance compared to an optimum strategy, but they offer simplicity of mechanization and a CNR with a very low operating threshold.

Aguirre, Sergio↗

WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration

Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded as it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration framework that is clinically valuable and requires no specialized equipment.

60 APPLIED LIFE SCIENCES↗

Level B/C software ground navigation program. Delta-T processor

The Delta-T Processor (DTP) computes the instantaneous downtrack error in a specified orbiter onboard navigation state vector recovered via downlink telemetry. The downtrack error, expressed in units of time, is computed based on current incoming Earth based range and Doppler navigation tracking data and the ground selected onboard navigation state vector. The computed time difference when used to modify the timetag of the vector used for onboard navigation reduces the instantaneous downtrack error in this vector to within the threshold of the DTP, the input data, and the onboard software. This threshold is currently estimated to be approximately 2 to 4 nautical miles. The DTP is not restricted to using only onboard vectors. Any vector, either input via the manual entry device or accessible via the vector administration table, may be used. The DTP does not require that both data types be available.

Source record↗

CATS-based Agents That Err

This report describes preliminary research on intelligent agents that make errors. Such agents are crucial to the development of novel agent-based techniques for assessing system safety. The agents extend an agent architecture derived from the Crew Activity Tracking System that has been used as the basis for air traffic controller agents. The report first reviews several error taxonomies. Next, it presents an overview of the air traffic controller agents, then details several mechanisms for causing the agents to err in realistic ways. The report presents a performance assessment of the error-generating agents, and identifies directions for further research. The research was supported by the System-Wide Accident Prevention element of the FAA/NASA Aviation Safety Program.

Callantine, Todd J.↗