Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Search for BSM Astroparticles in DUNE Far Detectors for NNN24

Despite the many gravitational pieces of evidence about the existence of Dark Matter (DM), its composition remains unknown. As new approaches were demanded, a well-motivated class of models was proposed in the last decade. In this context, DUNE, currently under construction in the Sanford Underground Research Facility in the US, offers an excellent opportunity to study these models and will be able to make a possible discovery. This work presents the DUNE’s sensitivity for Boosted DM from the Sun, which is the first time of astroparticles searches in DUNE with the full simulation and reconstruction of the detector capabilities. We also discuss an early stage sensitivity analysis for cosmogenic axions in DUNE.

Peres, Leonardo S. [Rio de Janeiro Federal U.]↗

Characterization of the Hamamatsu 8-inch R14688-100 PMT

Large-scale optical neutrino and dark-matter detectors rely on large-area photomultiplier tubes (PMTs) for cost-effective light detection. The new R14688-100 8-inch PMT developed by Hamamatsu provides state-of-the-art timing resolution of around 1 ns (FWHM), which can help improve vertex reconstruction and enable Cherenkov and scintillation light separation in scintillation-based detectors. This PMT also provides excellent charge resolution, allowing for precision photoelectron counting and improved energy reconstruction. The Eos experiment is the first large-scale optical detector to utilize these PMTs. Here, in this manuscript, we present a characterization of the R14688-100 single photoelectron response, such as the transit-time spreads, the dark-rates, and the afterpulsing. The single photoelectron response measurements are performed for the 206 PMTs that will be used in Eos.

47 OTHER INSTRUMENTATION↗

Dynamic focusing of laser driven positron jets by self-generated fields

Abstract Focusing effect of laser-driven positron jets by self-generated target sheath fields has been observed for the first time experimentally and the results are supported by the computational studies. In the experiment, OMEGA EP short-pulse (0.7 ps, 500 J) irradiates mm-size gold targets with a concave back surface and reference flat-surface targets. Both targets exhibited positrons with quasi-monoenergetic energy peaks while targets with concave curvature also showed increased number of positrons at the detector. The data is consistent with hybrid-PIC simulations confirming that the time-varying electric fields driven by electrons escaping from the target significantly change the trajectories of positrons. These simulations show a small radius of curvature on the rear side increases the relative focusing effect and the positrons to electrons ratio in the escaping plasma. For the smallest radius of curvature, positron jets that are up to 10 times denser can be achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conducting Beyond the Standard Model Searches in the MicroBooNE Detector with Machine Learning

MicroBooNE is one of the three neutrino detectors that comprise the Short Baseline Neutrino program at Fermilab. It utilizes Liquid Argon Time Projection Chamber (LArTPC) technology to probe the anomalous excess of electron-like events seen by its predecessor, MiniBooNE. Additionally, it provides a rich avenue of study for Beyond the Standard Model (BSM) theories. In the GeV energy regime relevant to MicroBooNE's beam neutrino program, many such theories lead to signatures which produce electron-positron (e+e-) final-states in the detector. While photons can pair produce into e+e- pairs with negligible opening angles, BSM theories often predict e+e- pairs with a broader range of opening angles. Thus, developing a tool that can reliably measure the opening angles of e+e- events is crucial for conducting rigorous BSM studies. However, these e+e- pairs result in topologically complex showers instead of clean tracks, making non-machine learning (ML) based methods such as line-fitting unsuitable for this task. This poster discusses the effectiveness of ML, namely a graph neural network called PointNet++, in accomplishing this goal. Our studies show promising results, with a resolution for the opening angle of 5 or less.

Bhelande, Vedang Adutya [Los Alamos]↗

Very-High Dynamic Range, 10,000 Frames/Second Pixel Array Detector for Electron Microscopy

Precision and accuracy of quantitative scanning transmission electron microscopy (STEM) methods such as ptychography, and the mapping of electric, magnetic, and strain fields depend on the dose. Reasonable acquisition time requires high beam current and the ability to quantitatively detect both large and minute changes in signal. A new hybrid pixel array detector (PAD), the second-generation Electron Microscope Pixel Array Detector (EMPAD-G2), addresses this challenge by advancing the technology of a previous generation PAD, the EMPAD. The EMPAD-G2 images continuously at a frame-rates up to 10 kHz with a dynamic range that spans from low-noise detection of single electrons to electron beam currents exceeding 180 pA per pixel, even at electron energies of 300 keV. The EMPAD-G2 enables rapid collection of high-quality STEM data that simultaneously contain full diffraction information from unsaturated bright-field disks to usable Kikuchi bands and higher-order Laue zones. Test results from 80 to 300 keV are presented, as are first experimental results demonstrating ptychographic reconstructions, strain and polarization maps. We introduce a new information metric, the maximum usable imaging speed (MUIS), to identify when a detector becomes electron-starved, saturated or its pixel count is mismatched with the beam current.

36 MATERIALS SCIENCE↗

Mulan: a part-per-million measurement of the muon lifetime and determination of the Fermi constant

The part-per-million measurement of the positive muon lifetime and determination of the Fermi constant by the MuLan experiment at the Paul Scherrer Institute is reviewed. The experiment used an innovative, time-structured, surface muon beam and a near-4 \pi π , finely-segmented, plastic scintillator positron detector. Two in-vacuum muon stopping targets were used: a ferromagnetic foil with a large internal magnetic field, and a quartz crystal in a moderate external magnetic field. The experiment acquired a dataset of 1.6 \times 10^{12} 1.6 × 10 12 positive muon decays and obtained a muon lifetime \tau_{\mu} = 2\, 196\, 980.3(2.2) τ μ = 2 196 980.3 ( 2.2 ) ~ps (1.0~ppm) and Fermi constant G _F = 1.166\, 378\, 7(6) \times 10^{-5} F = 1.166 378 7 ( 6 ) × 10 − 5 GeV ^{-2} − 2 (0.5~ppm). The thirty-fold improvement in \tau_{\mu} τ μ has proven valuable for precision measurements in nuclear muon capture and the commensurate improvement in G _F F has proven valuable for precision tests of the standard model.

Carey, Rebecca↗

Identification and mitigation of memory block timing issue in ITk ABCStar during ASIC production

The ABCStar is a mixed-signal front-end readout ASIC for the strips sensor portion of the ATLAS ITk detector being developed as part of the High-Luminosity LHC upgrade. In pre-production testing, a subtle design flaw was uncovered in the ABCStar that was reducing wafer yields in some manufactured lots from the expected 90% to as low as 2%. The root cause was determined to be a timing issue in the logic synthesized to control previously silicon proven memory blocks re-used for this ASIC. The solutions proposed included manufacturing process changes by the wafer foundry, changes to the operating parameters for the ABCStar in the detector, and the possibility that a redesign might be required. The two mitigation efforts were undertaken in parallel, with the process modification route a less desirable solution since already manufactured wafers would need to be scrapped in favour of the new ones. Based on a knowledge of the existing process, and testing done on the worst performing wafers, it was proposed that raising the core operating voltage of the ABCStar from 1.20V to 1.25V could address the timing issue by sufficiently speeding up its transistors. An extensive testing program that included the effects of temperature and radiation expected over the lifetime of the ITk detector was conducted to validate that approach. Those tests and studies proved that even the worst performing wafers would have yields over 80% with the 1.25V core voltage, and neither the modified process nor redesign would be required for ensuring reliable operation of the ITk. Based on testing, a further timing mitigation was implemented to provide an additional margin of reliability by increasing the duty cycle of the clock to the ABCStar. Testing of all ABCStar wafers has been completed and the production of the detector modules using these ASICs is now well underway as a result of the efforts detailed herein.

FOS: Physical sciences↗

Deep learning at the edge enables real-time streaming ptychographic imaging

Abstract Coherent imaging techniques provide an unparalleled multi-scale view of materials across scientific and technological fields, from structural materials to quantum devices, from integrated circuits to biological cells. Driven by the construction of brighter sources and high-rate detectors, coherent imaging methods like ptychography are poised to revolutionize nanoscale materials characterization. However, these advancements are accompanied by significant increase in data and compute needs, which precludes real-time imaging, feedback and decision-making capabilities with conventional approaches. Here, we demonstrate a workflow that leverages artificial intelligence at the edge and high-performance computing to enable real-time inversion on X-ray ptychography data streamed directly from a detector at up to 2 kHz. The proposed AI-enabled workflow eliminates the oversampling constraints, allowing low-dose imaging using orders of magnitude less data than required by traditional methods.

36 MATERIALS SCIENCE↗

Search for Higgs Portal Scalars and Heavy Neutral Leptons Decaying in the MicroBooNE Detector

This thesis presents a search for Higgs Portal Scalars (HPS) and Heavy Neutral Leptons (HNL) decaying in the MicroBooNE liquid argon time projection chamber (LArTPC). The measurement was performed using data collected in-time with the Neutrino at the Main Injector (NuMI) beam with a total exposure corresponding to 7.01x10^20 protons on target. Mono-energetic HPS and HNL would be produced from kaons decaying at rest in the NuMI hadron absorber, before travelling ~100 m to the MicroBooNE detector where they decay. A single selection and search strategy is used to target decays of HPS to muon-muon pairs and HNL to muon-pion pairs. The results are expressed as limits, at the 90% confidence level, on the mixing angles that control the rates of production and decay for each new particle. For the HNL model, upper limits are set on the mixing parameter |U\mu4|^2 in the range [12.9 x 10^-8, 0.54 x 10^-8] for HNL with masses in the region 246 - 385 MeV. For the HPS model, limits on the scalar-Higgs mixing angle \theta^2 are set, excluding a region with a lower boundary between [31.3 x 10^-9, 1.09 x 10^-9] and an upper boundary between [2.50 x 10^-5, 5.05 x 10^-9] for scalars with a mass of 212-275 MeV. These results set the first constraints in this region of parameter space from a dedicated experimental search for HPS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cherenkov Gamma Ray Detectors on High-Energy-Density Systems

Cherenkov gamma ray detectors are a valuable diagnostic technique for HED systems. Inertial confinement fusion is working towards high gain ignition. Gamma rays from ICF systems can help inform the degradation mechanisms preventing ignition: Carbon ablator is not being degraded, unlike the DT fuel; carbon γ timing can estimate shell energy during bangtime and may suggest hot spot cooling rate; and Cherenkov detectors are also used for high spatial and temporal resolution ICF mix studies on OMEGA. Cherenkov systems also inform energy spectrum of radiographic sources: ARC laser and Mercury pulsed power machine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vertex-finding and reconstruction of contained two-track neutrino events in the MicroBooNE detector

In this work, we describe algorithms developed to isolate and accurately reconstruct two-track events that are contained within the MicroBooNE detector. This method is optimized to reconstruct two tracks of lengths longer than 5cm. This code has applications to searches for neutrino oscillations and measurements of cross sections using quasi-elastic-like charged current events. The algorithms we discuss will be applicable to all detectors running in Fermilab's Short Baseline Neutrino program (SBN), and to any future liquid argon time projection chamber (LArTPC) experiment with beam energies ~ 1 GeV. The algorithms are publicly available on a GITHUB repository. This reconstruction offers a complementary and independent alternative to the Pandora reconstruction package currently in use in LArTPC experiments, and provides similar reconstruction performance for two-track events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Readout for Calorimetry at Future Colliders: A Snowmass 2021 White Paper

Calorimeters will provide critical measurements at future collider detectors. As the traditional challenge of high dynamic range, high precision, and high readout rates for signal amplitudes is compounded by increasing granularity and precision timing the readout systems will become increasingly complex. This white paper reviews the challenges and opportunities in calorimeter readout at future collider detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Topological background discrimination in the PandaX-III neutrinoless double beta decay experiment

The PandaX-III experiment plans to search for neutrinoless double beta decay (0ν ββ ) of 136 Xe in the China JinPing underground Laboratory (CJPL). The experiment will use a high pressure gaseous time projection chamber (TPC) to register both the energy and the electron track topology of an event. This article is devoted to demonstrate our particular detector setup capabilities for the identification of 0ν ββ and the consequent background reduction. As software tool we use REST, a framework developed for the reconstruction and simulation of TPC-based detector systems. We study the potential for background reduction by introducing appropriate parameters based on the properties of 0ν ββ events. We exploit for the first time not only the energy density of the electron track-ends, but also the electron scattering angles produced by an electron near the end of its trajectory. To implement this, we have added new algorithms for detector signal and track processing inside REST. Their assessment shows that background can be reduced by about 7 orders of magnitude while keeping 0ν ββ efficiency above 20% for the PandaX-III baseline readout scheme, a two-dimensional 3 mm pitch stripped readout. More generally, we use the potential of REST to handle 2D/3D data to assess the impact on signal-to-background significance at different detector granularities, and to validate the PandaX-III baseline choice. Finally, we demonstrate the additional potential to discriminate surface background events generated at the readout plane in the absence of to, by making use of event parameters related with the diffusion of electrons.

Majorana↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX) [Slides]

Post measurement synchronization of noise signals allowed for the investigation of previously unseen correlations. Noise of gamma, thermal and fast neutron signals performed similarly in estimating the prompt neutron decay constant at various subcritical states. The CPSD amplitude terms displayed different magnitudes. The neutron-based amplitudes suffered more from changes in detector efficiency as the number of fuel rods in the system increased. The time lag between 3 He tubes is observable using the CPSD phase angle and agreed with a simplified diffusion estimation.

3He detectors↗

Data-driven Detection and Early Prediction of Thermoacoustic Instability in a Multi-nozzle Combustor

Thermoacoustic instability (TAI) is a critical issue in modern lean-burn gas-turbine combustors, which is induced by a strong coupling between the resonant combustor acoustics and fluctuations in the heat release rate. This instability may lead to high-amplitude pressure waves that generate undesirable noise levels as well as fatigue stresses in mechanical structures of the combustor. The intense pressure fluctuations due to TAI may also cause large flow perturbations and possibly flow reversal that may lead to flame oscillations, flame liftoff, and even flame blow-out. Hence, there is a strong need for exercising control actions in a timely fashion to mitigate the TAI phenomena. Anomaly detection is an essential prerequisite to the design of a good controller and such a detector must be able to reliably predict a forthcoming TAI. To detect and predict the onset of a TAI from an ensemble of pressure time series, this paper investigates three data-driven methods: Fast Fourier transform (FFT), symbolic time series analysis (STSA), and hidden Markov modeling (HMM). The main focus of the paper is to make a comparative evaluation of these three anomaly detection methods for classification of the current regime of operation into stable and unstable categories as well as for real-time identification of precursors to impending instabilities with short-length time series of measured variables (e.g., pressure oscillations). Finally, the results, generated on experimental data from a multi-nozzle combustor apparatus, have been compared to evaluate the performance of FFT, STSA, and HMM methods for TAI analysis.

42 ENGINEERING↗

Observation of radon mitigation in MicroBooNE by a liquid argon filtration system

We report the MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq 222 Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trapping mechanism, MicroBooNE data supports a radon reduction factor of greater than 97% or 99.999%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the 222 Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Event reconstruction in a liquid xenon Time Projection Chamber with an optically-open field cage

nEXO is a proposed tonne-scale neutrinoless double beta decay (0νββ) experiment using liquid 136 Xe (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe (“skin” LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. Here, in this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the γ-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Then, background from 222 Rn dissolved in the skin LXe can be efficiently rejected by tagging the α decay in the 214 Bi- 214 Po chain in the skin LXe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time event reconstruction for Nuclear Physics Experiments using Artificial Intelligence

Charged track reconstruction is a critical task in nuclear physics experiments, enabling the identification and analysis of particles produced in high-energy collisions. Machine learning (ML) has emerged as a powerful tool for this purpose, addressing the challenges posed by complex detector geometries, high event multiplicities, and noisy data. Traditional methods rely on pattern recognition algorithms like the Kalman filter, but ML techniques, such as neural networks, graph neural networks (GNNs), and recurrent neural networks (RNNs), offer improved accuracy and scalability. By learning from simulated and real detector data, ML models can identify and classify tracks, predict trajectories, and handle ambiguities caused by overlapping or missing hits. Moreover, ML-based approaches can process data in near-real-time, enhancing the efficiency of experiments at large-scale facilities like the Large Hadron Collider (LHC) and Jefferson Lab (JLAB). As detector technologies and computational resources evolve, ML-driven charged track reconstruction continues to push the boundaries of precision and discovery in nuclear physics. In these proceedings, we highlight advancements in charged track identification leveraging Artificial Intelligence within the CLAS12 detector, achieving a notable enhancement in experimental statistics compared to traditional methods. Additionally, we showcase real-time event reconstruction capabilities, including the inference of charged particle properties, such as momentum, direction, and species identification, at speeds matching data acquisition rates. These innovations enable the extraction of physics observables directly from the experiment in real-time.

Gavalian, Gagik (ORCID:0000000267385457)↗