Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Operational Uncrewed Aircraft Systems Development for Meteorology and Atmospheric Physics Field Campaign Report

The overarching goal of the project is to develop integrated small, unmanned aircraft systems (SUAS) capabilities for enhanced atmospheric physics measurements. This team included atmospheric scientists, meteorologists, engineers, computer scientists, geographers, and chemists necessary to evaluate the needs and develop the advanced sensing and imaging, robust autonomous navigation, enhanced data communication, and data management capabilities required to use SUAS in atmospheric physics. The flight campaigns at the Southern Great Plains (SGP) U.S. Department of Energy Atmospheric Radiation Measurement (ARM) observatory were an integrated evaluation of the systems in coordinated field tests. This enabled sensor testing, and validation of SUAS technology and integration of unmanned aircraft into the airspace. The set of experiments enabled evaluation and progression of remote UAS deployment operations with observing atmospheric sensors. Each flight test endeavor was notable for the significant lessons learned during every deployment event. Team size and roles, equipment use, aircraft instruments, meteorological instruments, and deployment logistics, were all evaluated and improved at every flight-testing day. The details of these are further discussed in the Results section.

54 ENVIRONMENTAL SCIENCES↗

Characterizing Overwater High Ozone Events in the Houston–Galveston–Brazoria Region during the 2021 GO3 and TRACER-AQ Campaigns

Photochemical modeling outputs showing high ozone concentrations over the Gulf of Mexico and Galveston Bay during ozone episodes in the Houston–Galveston–Brazoria (HGB) region have not been previously verified using in situ observations. Such data were collected systematically, for the first time, from July to October 2021 from three boats deployed for the Galveston Offshore Ozone Observations (GO3) and Tracking Aerosol Convection Interactions Experiment—Air Quality (TRACER-AQ) field campaigns. A pontoon boat and a commercial vessel operated in Galveston Bay, while another commercial vessel operated in the Gulf of Mexico offshore of Galveston. All three boats had continuously operating sampling systems that included ozone analyzers and weather stations, and the two boats operating in Galveston Bay had a ceilometer. The sampling systems operated autonomously on the two commercial boats as they traveled their daily routes. Thirty-seven ozonesondes were launched over water on forecast high ozone days in Galveston Bay and the Gulf of Mexico. During the campaigns, multiple periods of ozone exceeding 100 ppbv were observed over water in Galveston Bay and the Gulf of Mexico. These events included previously identified conditions for high ozone events in the HGB region, such as the bay/sea-breeze recirculation and postfrontal environments, as well as a localized coastal high ozone event after the passing of a tropical system (Hurricane Nicholas) that was not well forecast.

54 ENVIRONMENTAL SCIENCES↗

Optimal Long-term Operation of SOEC Systems

This presentation was delivered at the 2023 AICHE Annual Meeting. This presentation would focus on dynamic optimization of solid oxide cell systems with due consideration of chemical degradation over the cell lifetime. A multi-scale dynamic optimization algorithm is solved and found to yield superior results compared to the constant voltage or constant H2 production operation approaches.

Giridhar, Nishant↗

PNNL OS3700 Tritium Monitoring System Software and Hardware Operations Manual (Rev.2)

The Pacific Northwest National Laboratory (PNNL) OS3700 Tritium Monitoring System Software and Hardware Operations Manual describes how to install and operate the software and hardware on a personal computer operating in conjunction with the Berthold Technologies LB110 flow-through proportional counter detector system. Included are operational details for the software functions, how to read and use the dropdown menus, how to understand readings and calculations, and how to access the database tables.

54 ENVIRONMENTAL SCIENCES↗

2019 Megasun Illumination System. Modifications and Operating Procedure Updates [Slides]

The original operating procedure was nearly 20 years old, though it was on a semi-annual review schedule. Some electrical categories had changed, as well as their risk management assessments. The IWD did not reflect these updated guidelines. No injuries have been reported during nearly 20 years of operation (not a bad record), however, several abnormal conditions came to surface during our Hazard Analysis conversations. One of which included an oil based capacitor malfunction which cracked it’s housing and leaked oil within the 2001 system. Our training and qualifications were updated to reflect LANL’s current standards.

42 ENGINEERING↗

Editorial: Themed issue on data-intensive water systems management and operation

The water sector increasingly looks at intensified instrumentation, data collection and automation as tools for daily use. Still, a massive opportunity remains to fully embrace emerging methods and technologies, such as artificial intelligence, data analytics, low-cost sensor hardware, and cloud computing. Indeed, sensing and automation technology has already infiltrated many facets of society. As such, the time is ripe to evaluate the role of novel technologies for systems monitoring, diagnostics, and automation of aquatic processes and large-scale water systems. When leveraged, the water sector will do more with less.

54 ENVIRONMENTAL SCIENCES↗

Electrification Futures Study: Operational Analysis of U.S. Power Systems with Increased Electrification and Demand-Side Flexibility

This report provides a high-resolution U.S. national-scale power systems assessment of scenarios with widespread electrification using detailed grid simulations. We find that high electrification scenarios envisioned in the Electrification Futures Study can be operated at the hourly level to meet future increased levels of electrified demand and, under the most aggressive cases, with up to 66% of generation from wind and solar technologies. The analysis also examines the value of flexibility from demand by supporting system operability under high electrification and high renewable systems. Demand-side flexibility—especially flexibility from newly electrified loads—is found to enhance the operational efficiency by reducing VRE curtailment and increasing utilization of generators with lower operating costs. It can also enhance the ability of electrification to decarbonize the energy sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bio-project “derisking” through development of systematic methodologies and frameworks for risk assessment

One of the primary hindrances to producing a viable, sustainable domestic biomass industry for renewable biofuels, bio-products and bio-power is the lack of understanding and quantification of the risks associated with both the biomass supply chain and preprocessing and conversion technologies. Currently a consistent method for assessing, comparing, and quantifying risks in biomass supply chains does not exist, creating a major investment barrier to bioenergy projects in the U.S. The lack of a standardized approach has resulted in bioenergy stakeholders independently using inconsistent approaches and evaluation criteria, leading to unreliable and incomparable assessments of risks and financing barriers to bio-project development. Along with the challenges of inconsistent risk assessment for supply chain risk, technology specific risks based on variability in biomass properties are not fully understood and can pose significant unforeseen challenges for bioenergy projects. In many cases these properties have not yet been identified and the impacts on the proposed technology and products unquantified. This is particularly challenging for emerging preprocessing and conversion technologies. Without a firm understanding of the preprocessing/conversion technology-specific critical properties, the risk of a proposed bio-project cannot be fully evaluated. To address inconsistent risk evaluation in the biomass supply chain supporting project financing, a Biomass Supply Chain Risk Standards (BSCRS) framework was developed. The BSCRS framework includes a comprehensive list of known and perceived risks (Risk Indicators) to the supply chain developed through 100’s of interviews with bioenergy industry experts spanning from feedstock growers and suppliers to representatives from the financial sector. These risks have been organized into a manageable hierarchy of Risk Categories and Risk Factors that can be practically assessed. This BSCRS framework also provides mitigation strategies for multiple Risk Indicators from best available industry practices and research findings. Additionally, a risk quantification methodology for each Risk Factor, Risk Category, and the bio-project as a whole was developed to enable capital markets to assess feedstock risk more efficiently and more accurately. Multiple case studies representing existing bio-projects have been used to evaluate and verify the BSCRS framework and scoring methodology. To address technological risk along with the supply chain risk captured in the developed BSCRS framework, this work also focuses on development of a systematic criticality assessment tool using well-accepted, quantitative risk analysis methods to evaluate bioenergy feedstock critical properties impacting system unit operations. The proposed Failure Mode and Effect Analysis (FMEA) approach uses a team of subject area experts (SAEs) for each targeted unit operation within a system. Collectively, the team will develop and use a quantitative scoring system to assess the material attributes, process parameters, and quality attributes for key unit operations that have already been identified. The FMEA process generates Risk Priority Numbers (RPNs) for the various failures and predominant causes for each material/process unit/product combination resulting in a semi-quantitative, standardized methodology for assessing technological risk and biomass properties contributing to that risk.

09 BIOMASS FUELS↗

Multi-objective Decisions on Integrated Energy Systems Planning and Operation for Industrial Combined Heat and Power Supply

Unlike the power sector—which can transmit electricity over long distances via established grids—the industrial sector poses a unique challenge due to its geographically concentrated large-scale heat processes. Enhancing energy security in such industrial parks provides a dual benefit: reduced exposure to volatile fossil fuel prices and improved economic viability, largely driven by economies of scale in energy supply and distribution. This study presents a comprehensive technoeconomic analysis of a nuclear energy hub, employing a mechanism-focused approach to evaluate uncertainties in operational strategies and capacity optimization. Load profiles from three major energy intesive industries—chemical, refinery, and steelmaking—are examined, each presenting unique challenges and opportunities for nuclear energy integration. We adopt a multi-objective optimization framework, converting multiple objectives into a single objective function through the e-constraint method. The findings highlight clear trade-offs between system conditions and varying levels of energy independence. Overall, this analysis is granular enough to address industry-specific concerns yet sufficiently generalizable to provide actionable insights into the feasibility of nuclear-based clean heat solutions for the industrial sector.

25 - ENERGY STORAGE↗

Conservation Voltage Reduction (CVR) via Two-Timescale Control in Unbalanced Power Distribution Systems

Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.

optimal control, distributed generation, fluctuati↗

Megawatt upgrade of NuMI target system

Fermilab operates the world’s highest power neutrino target system, called the Neutrinos at the Main Injector (NuMI) to provide intense neutrino flux to the NuMI Off-axis $\nu_{\mu}$ Appearance (NOvA) near and far neutrino detectors to reveal mysterious property of neutrinos. We report a progress of the NuMI beam power upgrade plan at Fermilab to transport a 1-Mega Watt (MW) proton beam to the high power neutrino target. The latest beam power record is 870 kW in Fall 2021.

Yonehara, Katsuya↗

Development of an accelerator-based neutron source to prototype Mo-99 production, Part II: A liquid LBE loop under a high vacuum

To provide US domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. Part I of this work discusses the design of a liquid lead–bismuth eutectic (LBE) windowless target for an accelerator-based neutron source development. Part II discusses how to couple this windowless target to an accelerator operating at an ultra-high vacuum and the subcritical UTA cooled by water at room temperature. Due to the windowless design of the target, the liquid LBE flow shares an ultra-high vacuum (<1.3 × 10 -7 Pa or 10 -9 Torr) space with the accelerator. As a result of this shared vacuum space, the LBE system must operate at a high vacuum (10 -3 ~10 -6 Pa or 10 -5 ~10 -8 Torr). A magnetic rotary motion feedthrough unit utilizes magnetic fluid to allow rotation of the pump while maintaining a high vacuum environment. Prior to testing the LBE system under vacuum, a pump curve measurement is performed to estimate flowrate in the system. This measurement also generates data on orifice loss coefficients, which are compared to correlations in literature. The second experiment investigates vacuum level in the LBE system during operation. High vacuum is maintained (10 -3 ~10 -5 Pa or 10 -5 ~10 -7 Torr) during system operation, and a residual gas analyzer (RGA) scan shows that partial pressures of residual gases in the LBE system lower over the duration of LBE system operations. The third experiment investigates the gravity driven liquid LBE flowing out of the target chamber in the return line, which is partially full. If the liquid LBE is not drained quickly enough, flooding in the target chamber could occur. The coefficient n in the Manning equation is found to be around 0.008 s/m 1/3 . The last experiment performed is a demonstration that a vacuum jacket could provide sufficient thermal insulation to allow coupling between 300 °C LBE loop and a water tank at room temperature. In conclusion, the results from these experiments have influenced the development of the neutron source for the future commercial scale Mo-99 production system.

43 PARTICLE ACCELERATORS↗

Controlling distributed energy resources via deep reinforcement learning for load flexibility and energy efficiency

Behind-the-meter distributed energy resources (DERs), including building solar photovoltaic (PV) technology and electric battery storage, are increasingly being considered as solutions to support carbon reduction goals and increase grid reliability and resiliency. However, dynamic control of these resources in concert with traditional building loads, to effect efficiency and demand flexibility, is not yet commonplace in commercial control products. Traditional rule-based control algorithms do not offer integrated closed-loop control to optimize across systems, and most often, PV and battery systems are operated for energy arbitrage and demand charge management, and not for the provision of grid services. More advanced control approaches, such as MPC control have not been widely adopted in industry because they require significant expertise to develop and deploy. Recent advances in deep reinforcement learning (DRL) offer a promising option to optimize the operation of DER systems and building loads with reduced setup effort. However, there are limited studies that evaluate the efficacy of these methods to control multiple building subsystems simultaneously. Additionally, most of the research has been conducted in simulated environments as opposed to real buildings. This paper proposes a DRL approach that uses a deep deterministic policy gradient algorithm for integrated control of HVAC and electric battery storage systems in the presence of on-site PV generation. The DRL algorithm, trained on synthetic data, was deployed in a physical test building and evaluated against a baseline that uses the current best-in-class rule-based control strategies. Performance in delivering energy efficiency, load shift, and load shed was tested using price-based signals. The results showed that the DRL-based controller can produce cost savings of up to 39.6% as compared to the baseline controller, while maintaining similar thermal comfort in the building. The project team has also integrated the simulation components developed during this work as an OpenAIGym environment and made it publicly available so that prospective DRL researchers can leverage this environment to evaluate alternate DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗