Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “storage performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Hybrid electrolytes for group 2 cation-based electrochemical energy storage device

This invention relates to the field of energy storage devices, and especially electrochemical energy storage devices including electrolytes comprising an ionic liquid, one or more solvents, and one or more salts of a Group 2 element. Effects on electrochemical performance of the electrolyte of each of the components of the electrolyte were systematically determined. In addition, interactions between the electrolytes and separator films were dissected to optimize electrochemical performance of coin cell batteries.

25 ENERGY STORAGE↗

Transport Phenomena in Low Temperature Lithium-Ion Battery Electrolytes

Lithium-ion batteries face low temperature performance issues, limiting the adoption of technologies ranging from electric vehicles to stationary grid storage. This problem is thought to be exacerbated by slow transport within the electrolyte, which in turn may be influenced by ion association, solvent viscosity, and cation transference number. How these factors collectively impact low temperature transport phenomena, however, remains poorly understood. Here we show using all-atom classical molecular dynamics (MD) simulations that the dominant factor influencing low temperature transport in LP57 (1 M LiPF 6 in 3:7 ethylene carbonate (EC)/ethyl methyl carbonate (EMC)) is solvent viscosity, rather than ion aggregation or cation transference number. We find that ion association decreases with decreasing temperature, while the cation transference number is positive and roughly independent of temperature. In an effort to improve low temperature performance, we introduce γ -butyrolactone (GBL) as a low viscosity co-solvent to explore two alternative formulations: 1 M LiPF 6 in 15:15:70 EC/GBL/EMC and 3:7 GBL/EMC. While GBL reduces solution viscosity, its low dielectric constant results in increased ion pairing, yielding neither improved bulk ionic conductivity nor appreciably altered ion transport mechanisms. We expect that these results will enhance understanding of low temperature transport and inform the development of superior electrolytes.

25 ENERGY STORAGE↗

Surpassing the Organic Cathode Performance for Lithium-Ion Batteries with Robust Fluorinated Covalent Quinazoline Networks

Organic electrode materials have promising application prospects in energy storage, but issues including rapid capacity fading and poor power capacity restrict their practical applications. In this study, nanoporous fluorinated covalent quinazoline networks (F-CQNs) were constructed by condensation of fluorinated aromatic aminonitrile precursors via an ionothermal pathway. Precise control of the reaction parameters afforded F-CQN-1-600 material featuring high surface area, permanent porosity, high nitrogen content (23.49 wt %), extended π-conjugated architecture, layered structure, and bipolar combination of benzene and tricycloquinazoline. Synergy among these unique properties leads to a good performance as a cathode source for lithium-ion batteries (LIBs) in terms of high capacity (250 mA h g –1 at 0.1 A g –1 ), high rate capability (105 mA h g –1 at 5.0 A g –1 ), and impressive cycling stability (95.8% retention rate after 2000 cycles at 2.0 A g –1 together with a high Coulombic efficiency of 99.95%), surpassing most of the previous organic cathode counterparts.

25 ENERGY STORAGE↗

Site Characterization of the Highest-Priority Geologic Formations for CO2 Storage in Wyoming

The project Site Characterization of the Highest-Priority Geologic Formations for CO2 Storage in Wyoming is one of 9 site characterization projects that were implemented as part of ARRA (American Recovery and Reinvestment Act). Data from this project was used to improve resolution of data in NATCARB in the area of study. Data related to this study has already been incorporated in NATCARB Atlas. The Wyoming Carbon Underground Storage Project (WY-CUSP) consisted of CO2 storage site characterization and evaluation, focusing on Wyoming’s most promising CO2 storage reservoirs (the Pennsylvanian Weber/Tensleep Sandstone and Mississippian Madison Limestone) and premier CO2 storage site (Rock Springs Uplift). Results from the WY-CUSP project suggest the two reservoirs could store up to 17,000 million tons of CO2. The WY-CUSP team drilled a stratigraphic test well and acquired a 3-D seismic survey covering 25 square miles of the Rock Springs Uplift site. The team retrieved 916 feet of core from the 12,810-foot-deep well, along with a complete log suite, borehole images, fluid samples, and other data. Project partners (1) provided continuous visual documentation of the core, including grain size, mineralogy, facies distribution, and porosity; (2) performed continuous permeability and velocity scans of selected reservoir intervals; and (3) chemically analyzed the fluid samples. WY-CUSP scientists integrated seismic attributes with observations from log suites, a VSP survey, core, fluid samples, and laboratory analyses, including continuous permeability scans. From these integrations, researchers constructed 3-D spatial distribution volumes of reservoir and seal properties that represent geological heterogeneity at the targeted CO2 storage site. The WY-CUSP team used this data to perform new CO2 plume migration simulations. Baker Hughes, Inc., completed a series of small-scale, in-situ water injectivity measurements. A database was formed when observations, analyses, and experiments from the stratigraphic test well were integrated. Correlation of these data allowed petrophysical parameters to be extrapolated from the test well out into the storage domain (5x5 mile 3-D seismic survey volume). This resulted in an improved, realistic understanding of performance assessments for potential CO2 storage scenarios. The WY-CUSP team worked on (1) improving CO2 storage resource estimates, (2) establishing long-term integrity and permanence of confining layers, (3) designing a profitable strategy for pressure management, and (4) evaluating the utilization of stored CO2 at the Rock Spring Uplift. Finally, Baker Hughes developed a microseismic baseline for the test site using in-bore geophones to complete field operations.

3-D seismic↗

Deep Learning for Land Cover Classification Using Only a Few Bands

There is an emerging interest in using hyperspectral data for land cover classification. The motivation behind using hyperspectral data is the notion that increasing the number of narrowband spectral channels would provide richer spectral information and thus help improve the land cover classification performance. Although hyperspectral data with hundreds of channels provide detailed spectral signatures, the curse of dimensionality might lead to degradation in the land cover classification performance. Moreover, in some practical applications, hyperspectral data may not be available due to cost, data storage, or bandwidth issues, and RGB and near infrared (NIR) could be the only image bands available for land cover classification. Light detection and ranging (LiDAR) data is another type of data to assist land cover classification especially if the land covers of interest have different heights. In this paper, we examined the performance of two Convolutional Neural Network (CNN)-based deep learning algorithms for land cover classification using only four bands (RGB+NIR) and five bands (RGB+NIR+LiDAR), where these limited number of image bands were augmented using Extended Multi-attribute Profiles (EMAP). The deep learning algorithms were applied to a well-known dataset used in the 2013 IEEE Geoscience and Remote Sensing Society (GRSS) Data Fusion Contest. With EMAP augmentation, the two deep learning algorithms were observed to achieve better land cover classification performance using only four bands as compared to that using all 144 hyperspectral bands.

58 GEOSCIENCES↗

Carbon decorated Li 3 V 2 (PO 4 ) 3 for high-rate lithium-ion batteries: Electrochemical performance and charge compensation mechanism

Fast charging and high-power delivering batteries are highly demanded in mobile electronics, electric vehicles and grid energy storage, but there are full of challenges. The star-material Li 3 V 2 (PO 4 ) 3 is demonstrated as a promising high-rate cathode material meeting the above requirements. Herein, we report the carbon decorated Li 3 V 2 (PO 4 ) 3 (LVP/C) cathode prepared via a facile method, which displays a remarkable high-rate capability and long-term cycling performance. Briefly, the prepared LVP/C delivers a high discharge capacity of 122 mAh g -1 (~93% of the theoretical capacity) at a high rate up to 20 C and a superior capacity retention of 87.1% after 1000 cycles. Importantly, by applying a combination of X-ray absorption spectroscopy and full-range mapping of resonant inelastic X-ray scattering, we clearly elucidate the structural and chemical evolutions of LVP upon various potentials and cycle numbers. Furthermore, we show unambiguous spectroscopic evidences that the evolution of the hybridization strength between V and O in LVP/C as a consequence of lithiation/delithiation is highly reversible both in the bulk and on the surface during the discharge-charge processes even over extended cycles, which should be responsible for the remarkable electrochemical performance of LVP/C. Our present study provides not only an effective synthesis strategy but also deeper insights into the surface and bulk electrochemical reaction mechanism of LVP, which should be beneficial for the further design of high-performance LVP electrode materials.

25 ENERGY STORAGE↗

Ethanol as a Liquid Organic Hydrogen Carrier for Seasonal Microgrid Application: Catalysis, Theory, and Engineering Feasibility

Here, we describe the benefits and challenges of a green approach to seasonal energy storage using ethanol as a liquid organic hydrogen carrier (LOHC). We evaluate the cycling efficiency of hydrogen release from ethanol (EtOH) to form ethyl acetate (EtOAc) as the spent LOHC and the subsequent regeneration of EtOH from EtOAc catalyzed by a single molecular catalyst, Ru-MACHO, at a moderate pressure of H 2 , mild reaction temperature, and high selectivity. From experimental and computational studies, we were able to minimize catalyst deactivation, regenerate the active catalyst post reactions, and establish the energy profile of the deactivation pathway relative to the on-cycle pathway catalyzed by Ru-MACHO. Based upon these findings, we performed a reactor design analysis to determine the footprint of an EtOH-based storage system to provide 85 MWh of energy by storing 5 metric tons (MT) of H 2 . We conclude that the heating and cooling required to maintain H 2 partial pressure present a significant engineering challenge for widespread deployment of this system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron Cloud Simulations for the Electron-Ion Collider in Brookhaven National Laboratory

For high-intensity circular accelerators and storage rings, if the secondary electron emission yield (SEY) of the vacuum chamber surfaces is high, an EC (Electron Cloud) could build up with the passage of the circulating beam. The presence of EC can strongly affect the beam quality, such as transverse instabilities, transverse emittance growth, and beam loss. Furthermore, the heat load from EC can exceed the available cryogenic capability. For the RHIC superconducting (SC) arc magnets, to be used for the hadron storage ring of the Electron-Ion Collider (EIC), the dynamic heat load budget is 0.5 W/m to the 4.5 K stainless steel beam pipe. This can limit the maximum beam bunches or intensity of the EIC, hence diminishing the luminosity provided by the EIC. The EC has affected the beam instability and significantly contributed to cryogenic heat load in the Large Hadron Collider (LHC). Positron storage rings for which ECs have been a critical factor in the design and performance include KEKB in Japan and EC buildup remains one of the concerns for future high-intensity accelerators design. EC considerations have driven the SuperKEKB collider design and the positron damping ring for the proposed International Linear Collider (ILC). The LHC luminosity upgrade is contingent on reducing the bunch spacing to 25 ns; at this bunch spacing, severe EC buildup has been observed. The success of the upgrade is likely contingent on limiting EC buildup. To study the EC heat load, we did some EC simulations with PyECLOUD code for the dipole, quadrupole, sextupole magnets, and the warm (drift) section of the EIC hadron storage ring. PyECLOUD is an EC simulation code developed by CERN. The code has been validated and used to study EC in the LHC, SPS, and PS. To eliminate EC buildup, the sources of electrons must be minimized. First, we will reduce the production of electrons due to residual gas ionization by specifying the maximum gas density, which requires a vacuum chamber with low electron-stimulated desorption (ESD) yields and a sufficient (preferably distributed) pumping speed. Second, we should reduce the secondary electrons with a lower secondary electron yield (SEY) material.

43 PARTICLE ACCELERATORS↗

MRCI Subtask 2.4/2.5: Regional/Subregional Analysis and Risk Assessment Final Technical Summary Report

The objective of the Midwest Regional Carbon Initiative (MRCI) project is to implement a collaborative Regional Initiative (RI) to accelerate the deployment of carbon capture, and storage (CCS) in the Midwest-Northeastern quadrant of the United States. This report is a Technical Summary report describing work performed on Tasks 2.4 (Conducting Regional/Subregional Analysis) and 2.5 (Assessing and Managing Risk) during the MRCI project. In Task 2.4, detailed numerical reservoir simulation models were developed for selected carbon storage (CS) systems identified under Task 2.1 (Battelle, 2021a) in the MRCI study area. The objective of Task 2.4 is to demonstrate a dynamic modeling methodology for evaluating the suitability of the (selected) CS systems in the MRCI region for hosting a commercial-scale storage project. In this study, CO2 injectivity was evaluated for different CS systems with an annual injection rate of 1 million metric tonnes (MMT) of CO2 considered as the minimum requirement for a commercial scale project. The objective of Task 2.5 is to assess key risks associated with storing CO2 in the different CS systems across the MRCI region and to demonstrate a method(s) for assessing these risks that may be used by developers of future CO2 storage projects in the region. The risk analysis was limited to evaluating two types of leakage risks (i.e., wellbore leakage, flow across unfractured caprock) at three modeled sites considered in Task 2.4.

MRCI,Report,Summary,Technical Challenges,dynamic m↗

Expanding the Material Search Space for Multivalent Cathodes

Multivalent batteries are an energy storage technology with the potential to surpass lithium-ion batteries; however, their performance have been limited by the low voltages and poor solid-state ionic mobility of available cathodes. A computational screening approach to identify high-performance multivalent intercalation cathodes among materials that do not contain the working ion of interest has been developed, which greatly expands the search space that can be considered for material discovery. This approach has been applied to magnesium cathodes as a proof of concept, and four resulting candidate materials [NASICON V 2 (PO 4 ) 3 , birnessite NaMn 4 O 8 , tavorite MnPO 4 F, and spinel MnO 2 ] are discussed in further detail. In examining the ion migration environment and associated Mg 2+ migration energy in these materials, local energy maxima are found to correspond with pathway positions where Mg 2+ passes through a plane of anion atoms. While previous studies have established the influence of local coordination on multivalent ion mobility, these results suggest that considering both the type of the local bonding environment and available free volume for the mobile ion along its migration pathway can be significant for improving solid-state mobility.

25 ENERGY STORAGE↗

Cyclic moisture reactivation of calcium sorbents for long duration thermochemical energy storage

The transition to a flexible and reliable energy infrastructure, using electro-thermal energy generation technologies such as geothermal, concentrated solar power, and nuclear, usually demands simultaneous advancement of thermal energy storage (TES) to support on-demand electricity generation and industrial applications while mitigating the inherent intermittency of renewable energy sources and power outages from direct energy generation. Among TES technologies, thermochemical energy storage (TCES) based on calcium looping emerges as a compelling high-power energy storage candidate due to its high reaction enthalpy, compatibility with elevated operating temperatures, and abundance of low-cost materials. However, the long-term durability of calcium-based sorbents for TCES is hindered by surface sintering and particle aggregation, leading to performance degradation over repeated thermal cycles. This study explores a moisture hydration-based strategy to regenerate a degraded calcium sorbent and mitigate performance degradation for long duration TCES. The addition of moisture transforms calcium oxide into calcium hydroxide and produces intercalation water layers, associated with a regenerated surface area and reduced calcium oxide crystallite size. Both these effects are beneficial in restoring the sorbents' reactivity for carbonization. Additionally, an optimized hydration-assisted reactivation protocol balances the recovered energy storage capacity with heating penalty required for moisture removal from hydrated samples, resulting in an enhanced energy storage capacity up to 176% compared to benchmark sorbents that undergo cycling without reactivation after 60 cycles. In conclusion, these results highlight the potential of hydration-assisted reactivation to enhance the long-term performance of TCES, providing an effective pathway to advancing electro-thermal storage technologies.

36 MATERIALS SCIENCE↗

Use of Multi-Attribute Utility Analyses to Assess Transportation Routes from ISFSIs - 20535

With two consolidated interim storage facilities for used nuclear fuel (UNF) having applied for storage licenses, there is the potential need to transport UNF in the U.S. from shutdown reactor sites to complete the site cleanup and from operating reactor sites who may be running out of storage options (e.g., spent fuel pools are nearly full and dry storage facilities are reaching licensed capacity). At some of the shutdown reactor sites, only the independent spent fuel storage installation (ISFSI) exists and often there remains a degraded transportation infrastructure for performing shipments from these sites. At other sites (e.g., operating reactor plants), the existing transportation infrastructure on the site is unchanged and sufficient for moving UNF, but the environment around the route may have changed (e.g., what was once a rural setting has transformed into a more urban setting) and/or local stakeholders want their input taken into consideration in UNF transportation activities. So, although preliminary evaluations have been performed to identify viable modes of transport from these sites using rail, barge, and/or heavy haul truck, if multiple options exist for moving the UNF from the site (e.g., multiple truck routes or a truck and a barge route both exist) then an evaluation that takes input from multiple stakeholders should be considered to identified the preference (e.g., ranking) of routes from a site. Orano has supported the development of several studies examining the viable routes for removing UNF from some of these sites and has utilized a multi-attribute utility analysis (MUA) to establish a ranking of routes and associated modes to move the UNF from the ISFSIs to a Class I rail carrier. The ultimate result from the MUA is a list(s) of the most to the least favored/preferred routes from the site. This paper provides an overview of the MUA methodology and provides an example of its application to a site with a shutdown reactor. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of 10+ hour energy storage with Φ1" laboratory size solid oxide iron–air batteries

Long duration electricity storage (LDES) with 10+ hour cycle duration is an economically competitive strategy to accelerate the penetration of renewable energy into the utility market. Unfortunately, none of the available energy storage technologies can meet the LDES requirements in terms of duration and cost. The newly emerged solid-oxide iron–air batteries (SOIABs) with energy-dense solid iron as an energy storage material have inherent advantages for LDES applications. Herein, we report for the first time the LDES capability of SOIABs even at a laboratory scale. We show that SOIABs with an Ir-catalyzed Fe-bed can achieve excellent energy density (625 W h kg –1 ), long cycle duration (12.5 h) and high round-trip efficiency (~90%) under LDES-related working conditions. Finally, given the excellent low-rate performance and the use of earth-abundant, low-cost Fe as an energy storage material, we conclude that the SOIAB is a well-suited battery technology for LDES applications.

25 ENERGY STORAGE↗

Draft Summary Report on Irradiated Fuel Handling and Management for LOTUS

The National Reactor Innovation Center (NRIC) has conceptualized the design of the Laboratory for Operation and Testing in the United States (LOTUS) test bed to provide the United States Department of Energy (DOE) with the infrastructure necessary to make advanced reactor designs available for commercial developers. LOTUS will provide a test bed to developers with the capabilities of supporting a wide range of experiment design possibilities. Upon completion of the developers’ operations and experiments within the test bed, the irradiated fuel, reactor components, and other experiment materials must be removed. Idaho National Laboratory (INL) possesses significant capabilities for radioactive material handling such as casks, carts, and forklifts. However, given the unique environment presented by the NRIC-LOTUS test bed, located inside the Zero Power Physics Reactor (ZPPR) Perimeter Intrusion Detection and Assessment System (PIDAS) area at the Materials and Fuels Complex (MFC) and the complexity of novel removal activities of recently operated reactor experiments through the new proposed access tunnel. The efficacy was not apparent for existing equipment to provide all the needed capability. To bridge the potential gaps in cask designs, storage, and transportation, NRIC requested the development of trade studies for the transfer, handling, and storage requirements of irradiated fuel salts and other radioactive materials. NRIC directed Boston Government Services, LLC (BGS) to perform the trade studies and develop a report analyzing alternatives. In addition to the BGS reports, the Idaho National Lab’s (INL), provided by the first potential user’s Advanced Reactor Development (ARD) team, prepared a feasibility study for the storage of specific irradiated fuel within the existing ZPPR vault.This summary report is intended to present the trade studies, options, and alternatives that were investigated. The maturity level of LOTUS, the reactor, fuel salt containers, gloveboxes, and reactor testing campaign and concept of operations were not at a level sufficient to base critical decisions on. This report is not intended to present a final recommendation. The final recommendations for fuel storage location, transport, handling equipment, and operations will be made in FY 2024 and will be based on known materials, test campaign requirements, funding, and final analysis of the fuel and equipment to be used.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Room Temperature to 150 °C Lithium Metal Batteries Enabled by a Rigid Molecular Ionic Composite Electrolyte

Molecular ionic composites (MICs), made from ionic liquids and a rigid-rod polymer poly(2,2'-disulfonyl-4,4'-benzidine terephthalamide) (PBDT), are a new type of rigid gel electrolyte that combine fast ion transport with high thermal stability and mechanical strength. In this work, a MIC electrolyte membrane is prepared that is composed of PBDT, lithium bis(trifluoromethylsulfonyl)imide (LiTFSI), and 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide (Pyr 14 TFSI) in a mass ratio of 10:10:80. The ionic conductivity at 25 °C is 0.56 mS cm –1 with no added flammable/volatile components. Although the polymer content is only 10 wt%, this MIC membrane is rigid with a tensile modulus of 410 MPa at room temperature. The MIC membrane remains stable and rigid at 200 °C with the shear storage modulus (G') only slightly decreasing by 35%. Li/MIC/LiFePO 4 cells demonstrate stable cycling performance over a wide temperature range from 23 to 150 °C. The specific discharge capacity at 100 and 150 °C at 1 C rate exceeds 160 mAh g –1 . The discharge capacity retention is 99% after 50 cycles at 150 °C. Furthermore, this stable battery performance shows that this low polymer content MIC membrane qualifies for use as a solid electrolyte in lithium metal batteries operating over a wide temperature range.

25 ENERGY STORAGE↗

SolarAPP+ Performance Review (2024 Data)

The Solar Automated Permit Processing Plus (SolarAPP+) platform is an online portal to facilitate and expedite rooftop solar photovoltaic (PV) and battery storage permitting processes. SolarAPP+ allows PV contractors to upload system specifications, have that information automatically reviewed for code compliance, and receive instant approval for code-compliant systems, reducing authority having jurisdiction (AHJ) staff time needed for review. SolarAPP+ also provides inspection checklists to verify installation practices and adherence to approved designs. This report is part of an ongoing series of reviews of SolarAPP+ performance. Consistent with previous performance reviews, we summarize SolarAPP+ adoption trends to date and compare various metrics for PV systems permitted through SolarAPP+ versus systems permitted through traditional AHJ permitting processes. As of the end of 2024, 799 AHJs had expressed interest in the platform, with 264 fully adopting (215) or piloting (49) the platform. In 2024, 861 installers submitted 37,393 permits through the SolarAPP+ platform, including 27,375 permits for PV+storage systems. SolarAPP+ permits accounted for around 43% of all permits issued in all participating AHJs, and more than 60% of all permits in several participating AHJs. We compare permitting timelines through SolarAPP+ to traditional AHJ permitting processes to assess the platform's performance. Consistent with previous SolarAPP+ performance reviews, we find that permitting timelines are significantly shorter for SolarAPP+ projects. Based on median timelines, a typical SolarAPP+ project is permitted and inspected 12 business days sooner than traditional projects. We estimate that automatic SolarAPP+ permitting saved around 18,400 hours of AHJ staff time in 2024. Finally, we estimate that SolarAPP+ eliminated over 100,000 business days in permitting-related delays in 2024.

14 SOLAR ENERGY↗

Parametric Study to Assess Technical Prospect Feasibility for Offshore CO 2 Storage

This report is a white paper on the parametric study to assess technical prospect feasibility for CO 2 storage with and without CO 2 -EOR. The SECARB Offshore GOM team reviewed key parameters that previous modeling experience suggests have the largest impact on CO 2 plume size and CO 2 -EOR performance (SSEB, 2019) These parameters include tectonic impacts (reservoir dip and fault block size), reservoir properties (permeability) and development strategies (well field payout, waterflood, and CO 2 flooding strategies). These parameters are further evaluated in this study in order to identify upper and lower boundary conditions for the parametric values. The boundary conditions are needed to set constraints for key parameters when performing modeling assessments. Understanding the key parametric values for the GOM will facilitate locating successful offshore carbon capture utilization and storage (CCUS) projects in terms of plume size, CO 2 stored and, in the case of EOR, oil recovery. Importantly, this white paper focuses on both technical factors (geologic and engineering), but does not address economic, commercial, or stakeholder considerations. The report is organized into four sections and includes a review of the datasets used to define the parameter ranges, the results of a full-physics reservoir simulation, a summary of a reduced order modeling approach to evaluate the impact of the study parameters, and, finally, a discussion of the work that will occur during the next phase of the project.

02 PETROLEUM↗