Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

The Grism Lens-Amplified Survey from space (GLASS). III. A census of Lyα emission at z≳7 from HST spectroscopy

We present a census of Lyα emission at z≳7, utilizing deep near-infrared Hubble Space Telescope grism spectroscopy from the first six completed clusters of the Grism Lens-Amplified Survey from Space (GLASS). In 24/159 photometrically selected galaxies we detect emission lines consistent with Lyα in the GLASS spectra. Based on the distribution of signal-to-noise ratios and on simulations, we expect the completeness and the purity of the sample to be 40%–100% and 60%–90%, respectively. For the objects without detected emission lines we show that the observed (not corrected for lensing magnification) 1σ flux limits reach 5 × 10{sup −18} erg s{sup −1} cm{sup −2} per position angle over the full wavelength range of GLASS (0.8–1.7 μm). Based on the conditional probability of Lyα emission measured from the ground at z∼7, we would have expected 12–18 Lyα emitters. This is consistent with the number of detections, within the uncertainties, confirming the drop in Lyα emission with respect to z∼6. Deeper follow-up spectroscopy, here exemplified by Keck spectroscopy, is necessary to improve our estimates of completeness and purity and to confirm individual candidates as true Lyα emitters. These candidates include a promising source at z = 8.1. The spatial extent of Lyα in a deep stack of the most convincing Lyα emitters with 〈z〉 = 7.2 is consistent with that of the rest-frame UV continuum. Extended Lyα emission, if present, has a surface brightness below our detection limit, consistent with the properties of lower-redshift comparison samples. From the stack we estimate upper limits on rest-frame UV emission line ratios and find f{sub CIV}/f{sub Lyα}≲0.32 and f{sub CIII]}/f{sub Lyα}≲0.23, in good agreement with other values published in the literature.

79 ASTRONOMY AND ASTROPHYSICS↗

VLT FORS2 COMPARATIVE TRANSMISSION SPECTROSCOPY: DETECTION OF Na IN THE ATMOSPHERE OF WASP-39b FROM THE GROUND

We present transmission spectroscopy of the warm Saturn-mass exoplanet WASP-39b made with the Very Large Telescope FOcal Reducer and Spectrograph (FORS2) across the wavelength range 411–810 nm. The transit depth is measured with a typical precision of 240 parts per million (ppm) in wavelength bins of 10 nm on a V = 12.1 mag star. We detect the sodium absorption feature (3.2 σ ) and find evidence of potassium. The ground-based transmission spectrum is consistent with Hubble Space Telescope ( HST ) optical spectroscopy, supporting the interpretation that WASP-39b has a largely clear atmosphere. Our results demonstrate the great potential of the recently upgraded FORS2 spectrograph for optical transmission spectroscopy, with which we obtained HST -quality light curves from the ground.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SPECTRUM AND TERM ANALYSIS OF CO iii MEASURED USING FOURIER TRANSFORM AND GRATING SPECTROSCOPY

The spectrum of Co iii has been recorded in the region 1562–2564 Å (64,000 cm{sup −1}–39,000 cm{sup −1}) by Fourier transform (FT) spectroscopy, and in the region 1317–2500 Å (164,000 cm{sup −1}–40,000 cm{sup −1}) using a 10.7 m grating spectrograph with phosphor image plate detectors. The spectrum was excited in a cobalt–neon Penning discharge lamp. We classified 514 Co iii lines measured using FT spectroscopy, the strongest having wavenumber uncertainties approaching 0.004 cm{sup −1} (approximately 0.2 mÅ at 2000 Å, or 1 part in 10{sup 7}), and 240 lines measured with grating spectroscopy with uncertainties between 5 and 10 mÅ. The wavelength calibration of 790 lines of Raassen and Ortí Ortin and 87 lines from Shenstone has been revised and combined with our measurements to optimize the values of all but one of the 288 previously reported energy levels. Order of magnitude reductions in uncertainty for almost two-thirds of the 3d{sup 6}4s and almost half of the 3d{sup 6}4p revised energy levels are obtained. Ritz wavelengths have been calculated for an additional 100 forbidden lines. Eigenvector percentage compositions for the energy levels and predicted oscillator strengths have been calculated using the Cowan code.

74 ATOMIC AND MOLECULAR PHYSICS↗

SCExAO and GPI Y JH band photometry and integral field spectroscopy of the young brown dwarf companion to HD 1160

Here, we present high signal-to-noise ratio, precise Y JH photometry and Y band (0.957–1.120 μm) spectroscopy of HD 1160 B, a young substellar companion discovered from the Gemini NICI Planet Finding Campaign using the Subaru Coronagraphic Extreme Adaptive Optics instrument and the Gemini Planet Imager. HD 1160 B has typical mid-M dwarf-like infrared colors and a spectral type of M5.5${}_{-0.5}^{+1.0}$, where the blue edge of our Y band spectrum rules out earlier spectral types. Atmospheric modeling suggests HD 1160 B has an effective temperature of 3000–3100 K, a surface gravity of log g = 4–4.5, a radius of 1.55 ± 0.10 R J, and a luminosity of log L/L ⊙ = –2.76 ± 0.05. Neither the primary's Hertzspring–Russell diagram position nor atmospheric modeling of HD 1160 B show evidence for a subsolar metallicity. Interpretation of the HD 1160 B spectroscopy depends on which stellar system components are used to estimate the age. Considering HD 1160 A, B and C jointly, we derive an age of 80–125 Myr, implying that HD 1160 B straddles the hydrogen-burning limit (70–90 M J ). If we consider HD 1160 A alone, younger ages (20–125 Myr) and a brown dwarf-like mass (35–90 M J ) are possible. Interferometric measurements of the primary, a precise Gaia parallax, and moderate-resolution spectroscopy can better constrain the system's age and how HD 1160 B fits within the context of (sub)stellar evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

The Disk Physical Conditions of 48 Persei Constrained by Contemporaneous Hα Spectroscopy and Interferometry

We utilize a multi-step modeling process to produce synthetic interferometric and spectroscopic observables, which are then compared to their observed counterparts. Our extensive set of interferometric observations of the Be star 48 Per, totaling 291 data points, were obtained at the Navy Precision Optical Interferometer from 2006 November 07 to 23. Our models were further constrained by comparison with contemporaneous Hα line spectroscopy obtained at the John S. Hall Telescope at the Lowell Observatory on 2006 November 1. Theoretical spectral energy distributions, SEDs, for 48 Per were confirmed by comparison with observations over a wavelength regime of 0.4–60 μm from Touhami et al. and Vieira et al. Our best-fitting combined model from Hα spectroscopy, Hα interferometry, and SED fitting has a power-law density fall off, n, of 2.3 and an initial density at the stellar surface of ρ{sub 0}=1.0×10{sup −11} g cm{sup −3} with an inclination constrained by Hα spectroscopy and interferometry of 45{sup ∘}±5{sup ∘}. The position angle for the system, measured east from north, is 114° ± 18°. Our best-fit model shows that the disk emission originates in a moderately large disk with a radius of 25 R {sub *}, which is consistent with a disk mass of approximately 5 × 10{sup 24} g or 3 × 10{sup −10} M {sub *}. Finally, we compare our results with previous studies of 48 Per by Quirrenbach et al. and find agreement, whereas our disk size does not agree with Delaa et al., based on a much smaller visibility set.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser Infrared Desorption Spectroscopy to Detect Complex Organic Molecules on Icy Planetary Surfaces

Laser Desorption-Infrared Spectroscopy (LD-IR) uses an IR laser pulse to desorb surface materials while a spectrometer measures the emission spectrum of the desorbed materials (Figure 1). In this example, laser desorption operates by having the incident laser energy absorbed by near surface material (~10 microns in depth). This desorption produces a plume that exists in an excited state at elevated temperatures. A natural analog for this phenomenon can be observed when comets approach the sun and become active and individual molecular emission spectra can be observed in the IR [1,2,3,4,5]. When this occurs in comets, the same species that initially emit radiation down to the ground state are free to absorb it, reducing the amount of detectable emission features. The nature of our technique results in absorption not occurring, because the laser pulse could easily be moved away form the initial desorption plume, and still have better spatial resolution then reflectance spectroscopy. In reflectance spectroscopy, trace components have a relatively weak signal when compared to the entire active nature of the surface. With LDIR, the emission spectrum is used to identify and analyze surface materials.

Laser Desorption-Infrared Spectroscopy↗

A Broadband X-Ray Imaging Spectroscopy with High-Angular Resolution: the FORCE Mission

We are proposing FORCE (Focusing On Relativistic universe and Cosmic Evolution) as a future Japan-lead X-ray observatory to be launched in the mid 2020s. Hitomi (ASTRO-H) possesses a suite of sensitive instruments enabling the highest energy-resolution spectroscopy in soft X-ray band, a broadband X-ray imaging spectroscopy in soft and hard X-ray bands, and further high energy coverage up to soft gamma-ray band. FORCE is the direct successor to the broadband X-ray imaging spectroscopy aspect of Hitomi (ASTRO-H) with significantly higher angular resolution. The current design of FORCE defines energy band pass of 1-80 keV with angular resolution of <15" in half-power diameter, achieving a 10 times higher sensitivity above 10 keV compared to any previous missions with simultaneous soft X-ray coverage. Our primary scientific objective is to trace the cosmic formation history by searching for "missing black holes" in various mass-scales: "buried supermassive black holes (SMBHs)" (> 10(exp 4) Stellar Mass) residing in the center of galaxies in a cosmological distance, "intermediate-mass black holes" (10(exp 2)-(10(exp 4) Stellar Mass) acting as the possible seeds from which SMBHs grow, and "orphan stellar-mass black holes" (< 10(exp 2) Stellar Mass) without companion in our Galaxy. In addition to these missing BHs, hunting for the nature of relativistic particles at various astrophysical shocks is also in our scope, utilizing the broadband X-ray coverage with high angular-resolution. FORCE are going to open a new era in these fields. The satellite is proposed to be launched with the Epsilon vehicle that is a Japanese current solid-fuel rocket. FORCE carries three identical pairs of Super-mirror and wide-band X-ray detector. The focal length is currently planned to be 10 m. The silicon mirror with multi-layer coating is our primary choice to achieve lightweight, good angular optics. The detector is a descendant of hard X-ray imager onboard Hitomi (ASTRO-H) replacing its silicon strip detector with SOI-CMOS silicon pixel detector, allowing an extension of the low energy threshold down to 1 keV or even less.

Hard X-ray↗

Micro Raman Spectroscopy for Characterizing Molecular Contamination on Space Flight Hardware

In the field of contamination control,many unknowns exist. Often, contamination control engineers have to utilize multiple spectroscopic, macroscopic, and microscopic tools to identify contamination sources when there is a potential contamination exposure to space flight hardware. Understanding the chemical composition of the molecular contamination provides an opportunity for contamination control engineers to determine if this contamination is problematic or benign. In this study, an existing witness plate program for monitoring space flight hardware during the assembly, integration, and testing phases is coupled with micro Raman spectroscopy analysis. The main goal of this study is to determine the limitations, reproducibility, and throughput of micro Raman spectroscopy for characterizing molecular contamination. Micro Raman Spectroscopy will be an additional tool used by contamination control engineers to monitor the cleanliness of space flight hardware.

Microscope↗

Prism Assembly for Roman Space Telescope Wide Field Instrument Slit-less Spectroscopy

The Roman Space Telescope (RST) is a three mirror anastigmat design with a 2.4 m primary mirror. RST will be based in L2 orbit, from where it will provide science information on exoplanets and dark energy using the Coronagraph Instrument (CGI) and Wide Field Instrument (WFI). The WFI features a 300 megapixel near-infrared detector array which provides a field of view 100 times larger than that of Hubble Space Telescope. The Prism Assembly is a small add-on instrument to the Roman Space Telescope’s Wide Field Instrument (WFI), installed in a slot in WFI’s element wheel. The Prism assembly has a passband from 0.75 µm to 1.8 µm, enabling a survey of redshifts in the range 0.2 to 1.7 µm. It provides low resolution slit-less spectroscopy with a spectral resolution R > 70 for all wavelengths, and R < 170 for λ > 0.8 µm across the full field. The Prism Assembly has the potential to provide more supernova spectra than ground-based spectroscopy during the mission lifetime. Being a late add-on to the RST mission, the Prism Assembly has had restrictions on size, weight and geometry, and a challenging schedule, which has dictated much of the implementation. Despite these challenges, the Prism Assembly is a pocket-sized high-performance spectrographic element, implemented as a refractive, all-spherical optical design using only two elements, one S-TIH-1 glass and one CaF2. This presentation will give an overview of the Prism Assembly, from design and implementation, through alignment, test and calibration. (100 words): The Roman Space Telescope is a three mirror anastigmat design with a 2.4 m primary mirror, which will provide science information on dark energy and exoplanets. The Prism Assembly is a small add-on instrument to the telescope’s Wide Field Instrument, enabling low resolution slit-less spectroscopy with a spectral resolution 70 < R < 170 across the full field from λ= 0.75 µm to 1.8 µm. The Prism Assembly is a refractive, all-spherical optical design using a glass and a CaF2 element. This presentation will give an overview of the Prism Assembly, from design and implementation, through alignment, test and calibration.

Space Instrumentation↗

Study of Coronal Heating in Solar Active Regions Using Wide-Field Imaging Spectroscopy: Hinode EIS Slot Observations

Understanding the frequency of heating events that keep the coronal plasma at several million Kelvin above the photospheric temperature of~ 6000K, is one of the most important problems in solar astrophysics. Spectroscopic observations of the Sun in the extreme ultraviolet (EUV) indicate that the coronal plasma reaches temperatures from 1 to 5 MK in active regions. It is also established that temperature in active regions can vary strongly with time and, moreover, contain sub-regions that evolve and develop separately. Tracking the spatio-temporal evolution of temperature requires continuous observation of the entire active region via imaging and spectroscopy. Traditional slit imaging spectroscopy probes plasma heating in solar active regions through observations of diagnostic emission lines and the resulting data are spectrally pure. Here, imaging is performed through rastering process, which severely limits co-temporal observations and often can be slow to miss events that evolve at other portions of the active region. In contrast, wide-field imaging spectroscopy offer simultaneous coverage of a large field of view as well as obtain spectral information in the same direction. This data suffers from spatial-spectral confusion, and are called spectroheliograms. Using the state-of-the-art inversion techniques that are developed recently, now spectroheliogram data can be unfolded to yield spectrally pure maps of large fields over long duration of observations. We use wide slit data, usually referred as ‘slot’, from the EUV Imaging Spectrometer (EIS) onboard Hinode satellite, focusing on active region observations. Here, we present our study of coronal heating in an active region using a long duration Hinode EIS slot observation.

Active region heating↗

2010 GRC VIBRATIONAL SPECTROSCOPY AUGUST 1 - AUGUST 6, 2010

The Vibrational Spectroscopy conference focuses on using vibrational spectroscopy to probe structure and dynamics of molecules in gases, liquids, and at interfaces. The conference explores the wide range of state-of-the-art techniques based on vibrational motion. These techniques span the fields of time-domain, high-resolution frequency-domain, spatially-resolved, nonlinear and multidimensional spectroscopies. The conference highlights the application of these techniques in chemistry, materials, biology, and medicine. The theory of molecular vibrational motion and its connection to spectroscopic signatures and chemical reaction dynamics is the third major theme of the meeting. The goal is to bring together a collection of researchers who share common interests and who will gain from discussing work at the forefront of several connected areas. The intent is to emphasize the insights and understanding that studies of vibrations provide about a variety of molecular systems ranging from small polyatomic molecules to large biomolecules and nanomaterials.

59 BASIC BIOLOGICAL SCIENCES↗

Vibrational spectroscopy of HNS degradation.

Hexanitrostilbene (HNS) is a widely used explosive, due in part to its high thermal stability. Degradation of HNS is known to occur through UV, chemical exposure, and heat exposure, which can lead to reduced performance of the material. Common methods of testing for HNS degradation include wet chemical and surface area testing of the material itself, and performance testing of devices that use HNS. The commonly used chemical tests, such as volatility, conductivity and contaminant trapping provide information on contaminants rather than the chemical stability of the HNS itself. Additionally, these tests are destructive in nature. As an alternative to these methods, we have been exploring the use of vibrational spectroscopy as a means of monitoring HNS degradation non-destructively. In particular, infrared (IR) spectroscopy lends itself well to non-destructive analysis. Molecular variations in the material can be identified and compared to pure samples. The utility of IR spectroscopy was evaluated using pressed pellets of HNS exposed to DETA (diethylaminetriamine). Amines are known to degrade HNS, with the proposed product being a {sigma}-adduct. We have followed these changes as a function of time using various IR sampling techniques including photoacoustic and attenuated total reflectance (ATR).

99 GENERAL AND MISCELLANEOUS↗

Alternative Sample Preparation of Soils for Gamma Spectroscopy

Standard laboratory procedures for preparation of soil samples for analysis by gamma spectroscopy typically utilize drying and grinding. Drying of soil samples can be accomplished using an oven for 8 to 16 hours or by air for several days or weeks. Dried samples are then sieved and / or ground to facilitate homogenization. The sample preparation process for soils adds significant time for analysis by gamma spectroscopy as the actual analysis is normally on the order of 1 hour or less. An alternative approach has been developed that significantly reduces sample preparation time for soil samples and that provides comparable results to those obtained by the standard method. The alternative approach utilizes a moisture analyzer to determine the percent moisture in each individual sample, which takes 15 to 45 minutes for each sample. The actual weight of the sample is then corrected by the percent moisture in order to report the results on the equivalent dry weight. This is especially important for samples that are for decision making associated with field activities where time is of the essence. This alternative sample preparation approach provides fast and efficient sample preparation of soils for gamma spectroscopy without reducing data quality or imparting bias. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extreme Spectroscopy: In situ nuclear materials behavior from optical data

In the nuclear industry, materials are regularly exposed to high temperature or/and irradiation and a better knowledge and understanding of their behavior under such extreme conditions is a key-point for improvements and further developments. Nowadays, Raman spectroscopy begins to be well known as a promising technique in the post mortem and remote characterization of nuclear materials exposed to extreme conditions. On this topic, at ANIMMA 2013 conference, we have presented some results about its implementation in the study of model or real nuclear fuel. However, the strength of Raman spectroscopy as in situ characterization tool is mainly its ability to be implemented remotely through optical fibers. Aware of this, implementation of other optical techniques can be considered in order to gain information not only on the structural dynamics of materials but also on the electronic charge carrier populations. In this paper, we propose to present our last advances in Raman characterization of nuclear materials and enlarge to the in situ use of complementary optical spectroscopies. Emphasis will be made on the information that can be gained to the behavior of the model fuel depleted UO{sub 2} under extreme conditions of high temperature and ionic irradiation: - In Situ Raman identification of the radiolysis alteration products of UO{sub 2} in contact with water under ionic irradiation. - In Situ Raman recording of the damaged dynamic of UO{sub 2} under inert atmosphere. - In Situ Raman and photo-luminescence study of virgin and damaged UO2 at high temperature. - In Situ study of electronic charge carriers' behavior in U{sub x}Th{sub 1-x}O{sub 2} solid solutions by mean of Iono- and Thermo- luminescence under and post- ionic irradiation. (authors)

36 MATERIALS SCIENCE↗

Raman Spectroscopy and Microscopy of Individual Cells andCellular Components

Raman spectroscopy provides the unique opportunity to non-destructively analyze chemical concentrations on the submicron length scale in individual cells without the need for optical labels. This enables the rapid assessment of cellular biochemistry inside living cells, and it allows for their continuous analysis to determine cellular response to external events. Here, we review recent developments in the analysis of single cells, subcellular compartments, and chemical imaging based on Raman spectroscopic techniques. Spontaneous Raman spectroscopy provides for the full spectral assessment of cellular biochemistry, while coherent Raman techniques, such as coherent anti-Stokes Raman scattering is primarily used as an imaging tool comparable to confocal fluorescence microscopy. These techniques are complemented by surface-enhanced Raman spectroscopy, which provides higher sensitivity and local specificity, and also extends the techniques to chemical indicators, i.e. pH sensing. We review the strengths and weaknesses of each technique, demonstrate some of their applications and discuss their potential for future research in cell biology and biomedicine.

42 ENGINEERING↗

Vacuum space charge effect in laser-based solid-state photoemission spectroscopy

We report a systematic measurement of the space charge effect observed in the few-ps laser pulse regime in laser-based solid-state photoemission spectroscopy experiments. The broadening and the shift of a gold Fermi edge as a function of spot size, laser power, and emission angle are characterized for pulse lengths of 6 ps and 6 eV photon energy. The results are used as a benchmark for an N-body numerical simulation and are compared to different regimes used in photoemission spectroscopy. These results provide an important reference for the design of time and angle-resolved photoemission spectroscopy setups and next-generation light sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The electronic structure of the CuRh{sub 1-x}Mg{sub x}O{sub 2} thermoelectric materials: An X-ray photoelectron spectroscopy study

A detailed X-ray photoelectron spectroscopy study has been performed for the CuRh{sub 1-x}Mg{sub x}O{sub 2} (x=0, 0.04 and 0.10) series for a better understanding of the role of the Mg{sup 2+} substitution on the electrical properties and the value of the Seebeck coefficient. This study is based on an analysis of different compounds such as Rh{sub 2}O{sub 3}, Sr{sub 2}RhO{sub 4} and CuCrO{sub 2} in order to characterize different oxidation states (Rh{sup 3+} and Rh{sup 4+} in octahedral oxygen environment and Cu{sup +} in a dumbbell O-Cu-O coordination). The Cu2p signal of copper in the non-doped compounds CuCrO{sub 2} and CuRhO{sub 2} reveals different electronic structures. An evolution of the Cu2p core signal with the increase of Mg{sup 2+} content in the CuRh{sub 1-x}Mg{sub x}O{sub 2} is highlighted by XPS. The differences observed, especially for the Cu2p core peaks are discussed for the non-doped compounds CuCrO{sub 2} and CuRhO{sub 2} as for the CuRh{sub 1-x}Mg{sub x}O{sub 2} series upon Mg{sup 2+} substitution. - Graphical Abstract: The role of the Mg substitution in the CuRh{sub 1-x}Mg{sub x}O{sub 2} as a function of x (x=0, 0.04 and 0.1) has been investigated by following the evolution of the Cu2p spectra obtained by X-ray photoelectron spectroscopy. The filled peaks are assigned to main peak A and A{sub sat} satellites, the hatched peaks to main peak B and B{sub sat} satellites. Highlights: > XPS investigations on CuRh{sub 1-x}Mg{sub x}O{sub 2} (x=0-0.04-0.1) delafossites. > Influence of magnesium doping on to the electrical properties and the electronic structures. > Copper cation keeps two oxidation states Cu{sup +}/Cu{sup 2+} in the CuRh{sub 1-x}Mg{sub x}O{sub 2} (x=0-0.4-0.1) with an increase of the Cu{sup 2+}/Cu ratio with the x value. > Cu layer seems to contribute to complex electrical transport in such delafossites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects and thermal stability of hydrogen microwave plasma treatment on tetrahedral amorphous carbon films by in situ ultraviolet photoelectron spectroscopy

This paper reports a comprehensive experimental study on the effects of hydrogen microwave plasma treatment on nonhydrogenated high sp{sup 3} content tetrahedral amorphous carbon (ta-C) film. In this study, a surface C-H dipole layer was first observed by high resolution electron energy loss spectroscopy, showing the presence of C-H bonding states. This resulted in the enhancement of electron field emission of the plasma treated films by largely lowering the turn-on field. Thermal stability tests using in situ ultraviolet photoelectron spectroscopy confirm that the C-H dipole layer not only reduces the work function of the films, it is extremely stable in both ambient and vacuum conditions and can sustain up to 600 deg. C annealing in vacuum. Atomic force microscopy studies also show minimal modifications to the surface morphology, leading to the conclusion that the C-H dipole layer is responsible for lowering the work function. This has improved the electron emission properties which can lead to potential applications such as electron emission displays.

36 MATERIALS SCIENCE↗