Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Visible emission spectra of thermographic phosphors under x-ray excitation

Thermographic phosphors have been employed for temperature sensing in challenging environments, such as on surfaces or within solid samples exposed to dynamic heating, because of the high temporal and spatial resolution that can be achieved using this approach. Typically, UV light sources are employed to induce temperature-sensitive spectral responses from the phosphors. However, it would be beneficial to explore x-rays as an alternate excitation source to facilitate simultaneous x-ray imaging of material deformation and temperature of heated samples and to reduce UV absorption within solid samples being investigated. Here, the phosphors BaMgAl 10 O 17 :Eu (BAM), Y 2 SiO 5 :Ce, YAG:Dy, La 2 O 2 S:Eu, ZnGa 2 O 4 :Mn, Mg 3 F 2 GeO 4 :Mn, Gd 2 O 2 S:Tb, and ZnO were excited using incident synchrotron x-ray radiation. These materials were chosen to include conventional thermographic phosphors as well as x-ray scintillators (with crossover between these two categories). X-ray-induced thermographic behavior was explored through the measurement of visible spectral response with varying temperature. The incident x-rays were observed to excite the same electronic energy level transitions in these phosphors as UV excitation. Similar shifts in the spectral response of BAM, Y 2 SiO 5 :Ce, YAG:Dy, La 2 O 2 S:Eu, ZnGa 2 O 4 :Mn, Mg 3 F 2 GeO 4 :Mn, and Gd 2 O 2 S:Tb were observed when compared to their response to UV excitation found in literature. Some phosphors were observed to thermally quench in the temperature ranges tested here, while the response from others did not rise above background noise levels. This may be attributed to the increased probability of non-radiative energy release from these phosphors due to the high energy of the incident x-rays. These results indicate that x-rays can serve as a viable excitation source for phosphor thermometry.

42 ENGINEERING↗

Roadmap on nanoscale magnetic resonance imaging

Abstract The field of nanoscale magnetic resonance imaging (NanoMRI) was started 30 years ago. It was motivated by the desire to image single molecules and molecular assemblies, such as proteins and virus particles, with near-atomic spatial resolution and on a length scale of 100 nm. Over the years, the NanoMRI field has also expanded to include the goal of useful high-resolution nuclear magnetic resonance (NMR) spectroscopy of molecules under ambient conditions, including samples up to the micron-scale. The realization of these goals requires the development of spin detection techniques that are many orders of magnitude more sensitive than conventional NMR and MRI, capable of detecting and controlling nanoscale ensembles of spins. Over the years, a number of different technical approaches to NanoMRI have emerged, each possessing a distinct set of capabilities for basic and applied areas of science. The goal of this roadmap article is to report the current state of the art in NanoMRI technologies, outline the areas where they are poised to have impact, identify the challenges that lie ahead, and propose methods to meet these challenges. This roadmap also shows how developments in NanoMRI techniques can lead to breakthroughs in emerging quantum science and technology applications.

Budakian, Raffi↗

Effects of head modeling errors on the spatial frequency representation of MEG

Abstract Objectives. We aim to investigate the effects of head model inaccuracies on signal and source reconstruction accuracies for various sensor array distances to the head. This allows for the assessment of the importance of head modeling for next-generation magnetoencephalography (MEG) sensors, optically-pumped magnetometers (OPM). Approach. A 1-shell boundary element method (BEM) spherical head model with 642 vertices of radius 9 cm and conductivity of 0.33 S m −1 was defined. The vertices were then randomly perturbed radially up to 2%, 4%, 6%, 8% and 10% of the radius. For each head perturbation case, the forward signal was calculated for dipolar sources located at 2 cm, 4 cm, 6 cm and 8 cm from the origin (center of the sphere), and for a 324 sensor array located at 10 cm to 15 cm from the origin. Equivalent current dipole (ECD) source localization was performed for each of these forward signals. The signal for each perturbed spherical head case was then analyzed in the spatial frequency domain, and the signal and ECD errors were quantified relative to the unperturbed case. Main results. In the noiseless and high signal-to-noise ratio (SNR) case of approximately ≥6 dB, inaccuracies in our spherical BEM head conductor models lead to increased signal and ECD inaccuracies when sensor arrays are placed closer to the head. This is true especially in the case of deep and superficial sources. In the noisy case however, the higher SNR for closer sensor arrays allows for an improved ECD fit and outweighs the effects of head geometry inaccuracies. Significance. OPMs may be placed directly on the head, as opposed to the more commonly used superconducting quantum interference device sensors which must be placed a few centimeters away from the head. OPMs thus allow for signals of higher spatial resolution to be captured, resulting in potentially more accurate source localizations. Our results suggest that an increased emphasis on accurate head modeling for OPMs may be necessary to fully realize its improved source localization potential.

Yeo, Wan-Jin (ORCID:0000000241417123)↗

Rapid retrieval of first-order spatiotemporal distortions for ultrashort laser pulses

High-intensity, ultrashort laser sources are a foundational pillar for High-Energy-Density (HED) physics, and as the repetition-rates of these systems increase, diagnostics must be developed to match their data collection speed. Characterization of any spatiotemporal distortions in the laser pulse is necessary in order to standardize results across facilities. Here, we have previously developed a laser diagnostic called Spatially and Temporally Resolved Intensity and Phase Evaluation Device: Full Information from a Single Hologram, or STRIPED FISH, to measure the full spatiotemporal laser electric field on a single shot. In order to provide rapid feedback, we here adapt the STRIPED FISH retrieval algorithm, which typically has computation times of up to 30 minutes due to the high spatial resolution of the device and its retrieval of the complete four-dimensional pulse field, to distill the key electric field quantities into a handful of scalars for rapid assessment of the pulse's first order distortions. Here, our new, rapid non-iterative retrieval algorithm is validated with simulated and experimental data, and it provides, within seconds, the same first-order information as given by the full analysis. This algorithm is suitable for on-shot assessment of spatiotemporal distortions and can be adapted to assess high repetition-rate laser quality in HED experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density limits as disruption forecasters for spherical tokamaks

Fusion power output from spherical tokamaks would benefit from increased confined plasma density, but there exists a limit on the density before confinement is lost and the plasma current is disrupted. This density limit has long been characterized by a simple, global Greenwald limit proportional to the plasma current and inversely proportional to the cross sectional area of the plasma. It is shown that in the database of discharges from the National Spherical Tokamak Experiment (NSTX) and Mega Ampere Spherical Tokamak (MAST) spherical tokamaks, the likelihood of disruption does increase above the Greenwald limit, and especially in the plasma current rampdown phase. The physics of the density limit has been recently theoretically explored through local criteria. Several of these are tested using the disruption event characterization and forecasting (DECAF TM ) code for their potential effectiveness as disruption warning signals. For a limited set of NSTX discharges, a local island power balance criteria was found to be less reliable, presently, than the Greenwald limit. For this work, an empirical critical edge line density and a boundary turbulent transport limit were both tested for MAST-U, which has an electron density profile measurement with high spatial resolution in the outer part of the plasma. Both were found to have similar dependencies on key plasma parameters. In a limited set of MAST-U discharges that appear to disrupt due to rising density at values under the Greenwald limit, crossing of the boundary turbulent transport limit occurred close to the time of disruption. Finally, these limits were evaluated for their potential use in real-time, and it was found that with the necessary real-time inputs and with refinement through further testing, these limits could be implemented in a real-time disruption forecasting system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bayesian inference of electron density and ion temperature profiles from neutral beam and halo Balmer- α emission at Wendelstein 7-X

By employing Bayesian inference techniques, the full electron density profile from the plasma core to the edge of Wendelstein 7-X (W7-X) is inferred solely from neutral hydrogen beam and halo Balmer- α (H α ) emission data. The halo is a cloud of neutrals forming in the vicinity of the injected neutral beam due to multiple charge exchange reactions. W7-X is equipped with several neutral hydrogen beam heating sources and an H α spectroscopy system that views these sources from different angles and penetration depths in the plasma. As the beam and halo emission form complex spectra for each spatial point that are non-linearly dependent on the plasma density profile and other parameters, a complete model from the neutral beam injection and halo formation through to the spectroscopic measurements is required. The model is used here to infer electron density profiles for a range of common W7-X plasma scenarios. The inferred profiles show good agreement with profiles determined by the Thomson scattering and interferometry diagnostics across a broad range of absolute densities without any changes to the input or fitting parameters. The time evolution of the density profile in a discharge with continuous core density peaking is successfully reconstructed, demonstrating sufficient spatial resolution to infer strongly shaped profiles. Furthermore, it is shown as a proof of concept that the model is also able to infer the main ion temperature profile using the same data set.

forward modeling↗

Development and preliminary results of 270 GHz microwave forward scattering diagnostic system on the experimental advanced superconducting tokamak (EAST)

To measure localized (intermediate, high) poloidal wavenumber electron density fluctuations, a tangential millimeter-wave collective scattering system has been designed and successfully developed on the experimental advanced superconducting tokamak (EAST). This innovative system employs a 270 GHz mm-wave probe beam, emitted from the mid-plane of Port K and directed towards Port P after passing through a combination of two in-vessel mirrors. Here these two ports are located on the EAST device’s midplane and are 110° apart. The downward scattered signals pass through two in-vessel mirrors, and exit through the P window. The received multi-channel separated scattering signals are arranged along the poloidal direction. This optical arrangement makes the monitored turbulent wave number is poloidal dominant and up to 40 cm −1 . The tangential microwave scattering scheme enables this diagnostic to monitor local density fluctuations, with typically a radial spatial resolution △ R = 5 cm, and a wavenumber resolution of △ k = 0.4 cm −1 . The scattering system underwent comprehensive laboratory testing in 2023, with installation finalized in 2024. The system features steerable launch and receiver optics, allowing remote control to position the scattering volume from normalized radius ρ –0 to the pedestal region on a shot-by-shot basis. Effective experimental data, characterized by distinct off-center spectral peaks, have been successfully obtained in neutral beam-heated plasmas on EAST. The beam tracing forward modeling has been employed for experimental data interpretation. The advanced millimeter-wave scattering system provides fluctuation measurement capability from ion temperature gradient to electron temperature gradient scale on low field side. Preliminary experimental density fluctuation data have been successfully obtained in neutral beam-heated plasmas on EAST. The localized measurement will be used for kinetic turbulence transport numerical simulation validation.

high-k collective scattering↗

XFEL imaging techniques for high energy density and inertial fusion energy research at HED-HiBEF

The imaging platform developed at the High Energy Density-Helmholtz International Beamline for Extreme Fields (HED-HiBEF) instrument at the European X-ray Free Electron Laser (XFEL) and its applications to HED and fusion related research are presented. The platform combines the XFEL beam with the high-intensity short-pulse laser ReLaX and the high-energy nanosecond-pulse laser DiPOLE-100X. The spatial resolution is better than 500 nm and the temporal resolution of the order of 50 fs. The influence of the XFEL source in the x-ray imaging method is discussed. Free-propagation x-ray phase contrast imaging and Talbot-Lau imaging setups are shown. We show examples of blast waves and converging cylindrical shocks in aluminum, resonant absorption measurements of specific charged states in copper with ReLaX and planar shocks in polystyrene material generated by DiPOLE-100X. For the first time, we show the application of Talbot-Lau interferometry to convergent cylindrical shocks as well as resonant absorption processes. We also discuss the possibilities introduced by combining this imaging platform with a kJ-class laser.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatio-temporal electric field distributions in an atmospheric plasma jet impinging on a microchannel array surface

The electric field distribution in the ionization waves (IWs) propagating over a microchannel array dielectric surface, with the channels either empty or filled with distilled water, is measured by ps electric field induced second harmonic generation. The surface IW is initiated by the atmospheric pressure N 2 –Ar plasma jet impinging on the surface vertically and powered by ns pulse discharge bursts. The results show that the electric field inside the microchannels, specifically its horizontal component, is enhanced by up to a factor of 2. The field enhancement region is localized within the channels. The vertical electric field inside the channels lags in time compared to the field measured at the ridges, indicating the transient reversal of the IW propagation direction across the channels (toward the jet). This is consistent with the phase-locked plasma emission images and confirmed by the kinetic modeling predictions, which show that the IW ‘jumps’ over the empty channels and propagates into the channels only after the jump between the adjacent ridges. When the channels are filled with water, the wave speed increases by up to 50%, due to the higher effective dielectric constant of the surface. No evidence of a significant electric field enhancement near the dielectric surface (ceramic or water) has been detected, within the spatial resolution of the present diagnostic, ~100 μ m.

plasmas and liquids↗

Evaluation of predictive correlation between flux expulsion and grain growth for superconducting radio frequency cavities

Abstract A series of experiments were carried out in an effort to develop a simple method for predicting the magnetic flux expulsion behavior of high purity niobium used to fabricate superconducting radio frequency (SRF) cavities. Using conventional metallographic characterizations in conjunction with high spatial resolution electron backscattered diffraction-orientation imaging microscopy, we find that the flux expulsion behavior of 1.3 GHz single cell SRF Nb cavities is significantly associated with the grain growth of the Nb material during heat treatment. Most of the Nb grains rapidly grew during 900 °C heat treatment, and were likely full-recrystallized with 1000 °C HT. When compared to the magnetic flux expulsion ratio ( B sc / B nc ) at Δ T = 5 K, the flux expulsion efficiency of the cavities increases with the increase of grain size. Most interestingly, 900 °C HT shows a roughly linear trend that suggests that this criterion could be used to predict the appropriate heat treatment temperature for sufficient flux expulsion behavior in SRF-grade Nb. This result can be used to see if flux expulsion can be predicted by examining the materials coming from Nb vendors, prior to cavity fabrication.

43 PARTICLE ACCELERATORS↗

Single-trial classification of evoked responses to auditory tones using OPM- and SQUID-MEG

Abstract Objective. Optically pumped magnetometers (OPMs) are emerging as a near-room-temperature alternative to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). In contrast to SQUIDs, OPMs can be placed in a close proximity to subject’s scalp potentially increasing the signal-to-noise ratio and spatial resolution of MEG. However, experimental demonstrations of these suggested benefits are still scarce. Here, to compare a 24-channel OPM-MEG system to a commercial whole-head SQUID system in a data-driven way, we quantified their performance in classifying single-trial evoked responses. Approach. We measured evoked responses to three auditory tones in six participants using both OPM- and SQUID-MEG systems. We performed pairwise temporal classification of the single-trial responses with linear discriminant analysis as well as multiclass classification with both EEGNet convolutional neural network and xDAWN decoding. Main results. OPMs provided higher classification accuracies than SQUIDs having a similar coverage of the left hemisphere of the participant. However, the SQUID sensors covering the whole helmet had classification scores larger than those of OPMs for two of the tone pairs, demonstrating the benefits of a whole-head measurement. Significance. The results demonstrate that the current OPM-MEG system provides high-quality data about the brain with room for improvement for high bandwidth non-invasive brain–computer interfacing.

Iivanainen, Joonas (ORCID:0000000160344604)↗

Spectroscopic measurement of increases in hydrogen molecular rotational temperature with plasma-facing surface temperature and due to collisional-radiative processes in tokamaks

Abstract Spatially resolved rotational temperature of ground state hydrogen molecules desorbed from plasma-facing surface was measured in QUEST, LTX-β, and DIII-D tokamaks, and the increases of the rotational temperature with the surface temperature and due to collisional-radiative processes in the plasmas were evaluated. The increase due to collisional-radiative processes was calculated by solving rate equations considering electron and proton collisional excitation and deexcitation and spontaneous emission. The calculation results suggest a high sensitivity for the rotational temperature to electron and proton densities, but a negligible sensitivity to the electron, proton, and surface temperatures. In the three tokamaks with different plasma parameters and plasma-facing surface materials, the spatial profile of the rotational temperature was estimated using Fulcher-α emission lines (600–608 nm). In QUEST, the spatial profile of the rotational temperature was estimated from spatially resolved spectra. In the other tokamaks, the rotational temperature was evaluated assuming a single point emission with a location determined from the Fulcher-α emission profile as measured with a filtered camera. In metal-walled devices QUEST and LTX-β, the rotational temperature increased with the surface temperature, and the calculated collisional-radiative increase is consistent with measured increase assuming that the rotational temperature at the surface is approximately 500–600 K higher than the surface temperature. In DIII-D with carbon walls, a larger collisional-radiative increase than the other tokamaks was observed because of the higher density leading to a large difference from the calculated increase compared to the other smaller tokamaks. Measurement of the Fulcher-α emission profile with higher spatial resolution in DIII-D may reduce the difference and reveal the effect of the surface temperature on the rotational temperature. These results show the increases in the rotational temperature with the surface temperature and due to the collisional-radiative processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Augmented signal processing in Liquid Argon Time Projection Chambers with a deep neural network

The Liquid Argon Time Projection Chamber (LArTPC) is an advanced neutrino detector technology widely used in recent and upcoming accelerator neutrino experiments. It features a low energy threshold and high spatial resolution that allow for comprehensive reconstruction of event topologies. In current-generation LArTPCs, the recorded data consist of digitized waveforms on wires produced by induced signal on wires of drifting ionization electrons, which can also be viewed as two-dimensional (2D) (time versus wire) projection images of charged-particle trajectories. For such an imaging detector, one critical step is the signal processing that reconstructs the original charge projections from the recorded 2D images. For the first time, we introduce a deep neural network in LArTPC signal processing to improve the signal region of interest detection. By combining domain knowledge (e.g., matching information from multiple wire planes) and deep learning, this method shows significant improvements over traditional methods. This work details the method, software tools, and performance evaluated with realistic detector simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon track reconstruction in a segmented bolometric array using multi-objective optimization

Recent advances in segmented solid-state detector arrays for rare-event searches have allowed the technology to approach the ton-scale in detector mass and the scale of meters in size. Often focused around searches for neutrinoless double-beta decay or direct dark matter detection, such experiments also have the capability to search for exotic particles that leave track-like signatures across their volume. However, the segmented nature of such detector arrays often sets the spatial resolution and makes the problem of reconstructing track-like paths non-trivial. Here, in this paper, we present an algorithm that improves reconstruction of track-like events in segmented detectors using multi-objective optimization — a computational technique that optimizes more than one cost function at a time without specifying a quantitative weighting between them. Such a technique allows the reconstruction of tracks through a detector and the determination of path-lengths through individual elements. When combined with the reconstructed energy depositions in each element this allows for a calculation of the stopping power of track-like particles and opens the door to searches for particles with abnormal stopping power like monopoles or lightly-ionizing particles (LIPs). Results are presented which evaluate the precision of the reconstruction tools as they currently stand against Monte Carlo generated data. The algorithm is presented in the context of the CUORE experiment, but has applications to other segmented calorimeter detectors.

47 OTHER INSTRUMENTATION↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 μm and 32 ps resolutions from strips of 1 cm length and 500 μm pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.

47 OTHER INSTRUMENTATION↗

The co-located arrangement of ECEI and MIR microwave imaging diagnostics on EAST tokamak

The co-located configuration of Passive Electron Cyclotron Emission Imaging (ECEI) and active Microwave Imaging Reflectometry (MIR) diagnostics systems has been successfully implemented on the EAST fusion reactor. These advanced 2D microwave diagnostic tools offer 10–20 mm poloidal spatial resolution through large aperture quasi optics. This arrangement not only optimizes the utilization of limited observation windows but also facilitates concurrent measurements of plasma density and electron temperature at specific toroidal positions. Furthermore, this co-located setup holds great promise for enhancing research into electron heat transport and other pivotal plasma phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The DUNE Far Detector Vertical Drift Technology. Technical Design Report

DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise. In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered. This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.

47 OTHER INSTRUMENTATION↗

High energy particle detection with large area superconducting microwire array

We present the first detailed study of an 8-channel2×2 mm$^{2}$ WSi superconducting microwire single photondetector (SMSPD) array exposed to 120 GeV proton beam and 8 GeVelectron and pion beam at the Fermilab Test Beam Facility. TheSMSPD detection efficiency was measured for the first time forprotons, electrons, and pions, enabled by the use of a silicontracking telescope that provided precise spatial resolution of30 μm for 120 GeV protons and 130 μm for 8 GeVelectrons and pions. The result demonstrated consistent detectionefficiency across pixels and at different bias currents. Timeresolution of 1.15 ns was measured for the first time for SMSPDwith proton, electron, and pions, enabled by the use of an MCP-PMTwhich provided a ps-level reference time stamp. The resultspresented is the first step towards developing SMSPD array systemsoptimized for high energy particle detection and identification forfuture accelerator-based experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗