Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “serialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Patterning via optical-saturable transformations: A review and simple simulation model

Most of the nanoscale fabrication in the semiconductor industry is based on patterning with scanning-electron beam lithography (SEBL). Although this approach is very versatile and has very high resolution, it is intrinsically a serial writing process, and therefore, relatively slow. Our group has been investigating alternative nano-fabrication techniques, adapted from ideas of saturating optical transitions such as those used in stimulated emission-depletion microscopy and related methods, and optical interference lithography. Linewidths and resolutions on the scale of a few tens of nanometers and below are highly desirable for various applications in nanotechnology. However, the spatial resolution of optical lithography is restricted by diffraction. In the past, we developed absorbance modulation to overcome this limit. This approach utilizes photochromic molecules that can be optically switched between two thermally stable states, one opaque and the other transparent. However, absorbance modulation is limited to surface (2-D) patterning. Here, we report on an alternative approach that exploits unique combinations of spectrally selective reversible and irreversible photochemical transitions to achieve deep subwavelength resolution with potential extension to 3-dimensions. This approach, which we refer to as patterning via optical-saturable transformations have the potential for massive parallelism, enabling the creation of nanostructures and devices at a speed far surpassing what is possible with SEBL. The aim of our research is to translate the success in circumventing Abbe's diffraction limit in optical microscopy to optical lithography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic force microscopy deep trench and sidewall imaging with an optical fiber probe

We report a method to measure critical dimensions of micro- and nanostructures using the atomic force microscope (AFM) with an optical fiber probe (OFP). This method is capable of scanning narrow and deep trenches due to the long and thin OFP tip, as well as imaging of steep sidewalls with unique profiling possibilities by laterally tilting the OFP without any modifications of the optical lever. A switch control scheme is developed to measure the sidewall angle by flexibly transferring feedback control between the Z- and Y-axis, for a serial scan of the horizontal surface (raster scan on XY-plane) and sidewall (raster scan on the YZ-plane), respectively. In experiments, a deep trench with tapered walls (243.5 μm deep) and a microhole (about 14.9 μm deep) have been imaged with the orthogonally aligned OFP, as well as a silicon sidewall (fabricated by deep reactive ion etching) has been characterized with the tilted OFP. Moreover, the sidewall angle of TGZ3 (AFM calibration grating) was accurately measured using the switchable scan method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A split-beam probe-pump-probe scheme for femtosecond time resolved protein X-ray crystallography

In order to exploit the femtosecond pulse duration of X-ray Free-Electron Lasers (XFEL) operating in the hard X-ray regime for ultrafast time-resolved protein crystallography experiments, critical parameters that determine the crystallographic signal-to-noise (I/σI) must be addressed. For single-crystal studies under low absorbed dose conditions, it has been shown that the intrinsic pulse intensity stability as well as mode structure and jitter of this structure, significantly affect the crystallographic signal-to-noise. Here, geometrical parameters are theoretically explored for a three-beam scheme: X-ray probe, optical pump, X-ray probe (or “probe-pump-probe”) which will allow experimental determination of the photo-induced structure factor amplitude differences, ΔF, in a ratiometric manner, thereby internally referencing the intensity noise of the XFEL source. In addition to a non-collinear split-beam geometry which separates un-pumped and pumped diffraction patterns on an area detector, applying an additional convergence angle to both beams by focusing leads to integration over mosaic blocks in the case of well-ordered stationary protein crystals. Ray-tracing X-ray diffraction simulations are performed for an example using photoactive yellow protein crystals in order to explore the geometrical design parameters which would be needed. The specifications for an X-ray split and delay instrument that implements both an offset angle and focused beams are discussed, for implementation of a probe-pump-probe scheme at the European XFEL. We discuss possible extension of single crystal studies to serial femtosecond crystallography, particularly in view of the expected X-ray damage and ablation due to the first probe pulse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High performance techniques for micro channel plate computations in photo multipliers

Monte Carlo - MC methods, requiring heavy computations of large data volume, can be used to predict the amplitude distribution and variance of outputted electron charge in Micro Channel Plates - MCPs, which are fed with primary emitted electrons in their inputs. The concept of parallel and serial combination of separate stages of such stochastic processes, which can be applied in MCP systems and simulated using MC computations, has recently proposed and shown interesting theorems and results. Separating the electron multiplication procedures, occurring in the channels of MCP systems, into sub-procedures, which are similar in nature and occur either in parallel or in consecutive manners, is equivalent to splitting the relevant stochastic system calculations into smaller ones, which can be performed concurrently and/or sequentially. In this way, calculations similar in nature, can be executed only once, thus, eliminating a great percentage of heavy computations. However, when designing and implementing the calculation inferences of the derived theorems using High Performance Computation - HPC techniques, the overall computation cost can further and significantly be reduced. In this paper, the hardware mappings of the relevant theorem inferences onto parallel computing architectures, resulting in circuits of computing blocks for calculation purposes of MCP system stochastic processes, are investigated. Each of the designed and implemented computing circuits corresponds to a theorem inference or to a combination of inferences. The parallelism of the proposed circuits consists of both the concurrent functioning of all the system blocks and of the simultaneous operation of each block, which is processing pieces of data, for many parts of the whole circuit in which it belongs. All the circuits are designed and tested using Altera Quartus II environment and can be implemented as chips, which can be incorporated in computing devices to assist Monte Carlo computations for the estimation of different MCP electron multiplication system performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flux tube train model for local turbulence simulation of toroidal plasmas

A new simulation method for local turbulence in toroidal plasmas is developed by extending the conventional idea of the flux tube model. In the new approach, a train of flux tubes is employed, where flux tube simulation boxes are serially connected at each end along a field line so as to preserve a symmetry of the local gyrokinetic equations for image modes in an axisymmetric torus. Validity of the flux tube train model is confirmed against the toroidal ion temperature gradient turbulence for a case with a long parallel correlation of fluctuations, demonstrating numerical advantages over the conventional method in the time step size and the symmetry-preserving property.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determining the size and concentration dependence of gold nanoparticles in vitro cytotoxicity (IC{sub 50}) test using WST-1 assay

Gold nanoparticles (AuNPs) received a great deal of attention for biomedical applications, especially in diagnostic imaging and therapeutics. Even though AuNPs have potential benefits in biomedical applications, the impact of AuNPs on human and environmental health still remains unclear. The use of AuNPs which is a high-atomic-number materials, provide advantages in terms of radiation dose enhancement. However, before this can become a clinical reality, cytotoxicity of the AuNPs has to be carefully evaluated. Cytotoxicity test is a rapid, standardized test that is very sensitive to determine whether the nanoparticles produced are harmful or benign on cellular components. In this work the size and concentration dependence of AuNPs cytotoxicity in breast cancer cell lines (MCF-7) are tested by using WST-1 assay. The sizes of AuNPs tested were 13 nm, 50 nm, and 70 nm. The cells were seeded in the 96-well plate and were treated with different concentrations of AuNPs by serial dilution for each size of AuNPs. The high concentration of AuNPs exhibit lower cell viability compared to low concentration of AuNPs. We quantified the toxicity of AuNPs in MCF-7 cell lines by determining the IC{sub 50} values in WST-1 assays. The IC{sub 50} values (inhibitory concentrations that effected 50% growth inhibition) of 50 nm AuNPs is lower than 13 nm and 70 nm AuNPs. Mean that, 50nm AuNPs are more toxic to the MCF-7 cells compared to smaller and larger sizes AuNPs. The presented results clearly indicate that the cytotoxicity of AuNPs depend not only on the concentration, but also the size of the nanoparticles.

60 APPLIED LIFE SCIENCES↗

A new development on measurement and control software of SANS BATAN spectrometer (SMARTer) in Serpong, Indonesia

In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card) for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic damage in S atoms in a native protein crystal induced by an intense X-ray free-electron laser pulse

Current hard X-ray free-electron laser (XFEL) sources can deliver doses to biological macromolecules well exceeding 1 GGy, in timescales of a few tens of femtoseconds. During the pulse, photoionization can reach the point of saturation in which certain atomic species in the sample lose most of their electrons. This electronic radiation damage causes the atomic scattering factors to change, affecting, in particular, the heavy atoms, due to their higher photoabsorption cross sections. Here, it is shown that experimental serial femtosecond crystallography data collected with an extremely bright XFEL source exhibit a reduction of the effective scattering power of the sulfur atoms in a native protein. Quantitative methods are developed to retrieve information on the effective ionization of the damaged atomic species from experimental data, and the implications of utilizing new phasing methods which can take advantage of this localized radiation damage are discussed.

Galli, L.↗

Fabrication and characterization of tunnel barriers in a multi-walled carbon nanotube formed by argon atom beam irradiation

We have evaluated tunnel barriers formed in multi-walled carbon nanotubes (MWNTs) by an Ar atom beam irradiation method and applied the technique to fabricate coupled double quantum dots. The two-terminal resistance of the individual MWNTs was increased owing to local damage caused by the Ar beam irradiation. The temperature dependence of the current through a single barrier suggested two different contributions to its Arrhenius plot, i.e., formed by direct tunneling through the barrier and by thermal activation over the barrier. The height of the formed barriers was estimated. The fabrication technique was used to produce coupled double quantum dots with serially formed triple barriers on a MWNT. The current measured at 1.5 K as a function of two side-gate voltages resulted in a honeycomb-like charge stability diagram, which confirmed the formation of the double dots. The characteristic parameters of the double quantum dots were calculated, and the feasibility of the technique is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microfluidic sorting of protein nanocrystals by size for X-ray free-electron laser diffraction

The advent and application of the X-ray free-electron laser (XFEL) has uncovered the structures of proteins that could not previously be solved using traditional crystallography. While this new technology is powerful, optimization of the process is still needed to improve data quality and analysis efficiency. One area is sample heterogeneity, where variations in crystal size (among other factors) lead to the requirement of large data sets (and thus 10–100 mg of protein) for determining accurate structure factors. To decrease sample dispersity, we developed a high-throughput microfluidic sorter operating on the principle of dielectrophoresis, whereby polydisperse particles can be transported into various fluid streams for size fractionation. Using this microsorter, we isolated several milliliters of photosystem I nanocrystal fractions ranging from 200 to 600 nm in size as characterized by dynamic light scattering, nanoparticle tracking, and electron microscopy. Sorted nanocrystals were delivered in a liquid jet via the gas dynamic virtual nozzle into the path of the XFEL at the Linac Coherent Light Source. We obtained diffraction to ∼4 Å resolution, indicating that the small crystals were not damaged by the sorting process. We also observed the shape transforms of photosystem I nanocrystals, demonstrating that our device can optimize data collection for the shape transform-based phasing method. Using simulations, we show that narrow crystal size distributions can significantly improve merged data quality in serial crystallography. From this proof-of-concept work, we expect that the automated size-sorting of protein crystals will become an important step for sample production by reducing the amount of protein needed for a high quality final structure and the development of novel phasing methods that exploit inter-Bragg reflection intensities or use variations in beam intensity for radiation damage-induced phasing. This method will also permit an analysis of the dependence of crystal quality on crystal size.

36 MATERIALS SCIENCE↗

Webcam autofocus mechanism used as a delay line for the characterization of femtosecond pulses

In this work, we present an electromagnetic focusing mechanism (EFM), from a commercial webcam, implemented as a delay line of a femtosecond laser pulse characterization system. The characterization system consists on a second order autocorrelator based on a two-photon-absorption detection. The results presented here were performed for two different home-made femtosecond oscillators: Ti:sapph @ 820 nm and highly chirped pulses generated with an Erbium Doped Fiber @ 1550 nm. The EFM applied as a delay line represents an excellent alternative due its performance in terms of stability, resolution, and long scan range up to 3 ps. Due its low power consumption, the device can be connected through the Universal Serial Bus (USB) port. Details of components, schematics of electronic controls, and detection systems are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional multimodal imaging and analysis of biphasic microstructure in a Ti–Ni–Sn thermoelectric material

The three-dimensional microstructure of levitation melted TiNi{sub 1.20}Sn has been characterized using the TriBeam system, a scanning electron microscope equipped with a femtosecond laser for rapid serial sectioning, to map the character of interfaces. By incorporating both chemical data (energy dispersive x-ray spectroscopy) and crystallographic data (electron backscatter diffraction), the grain structure and phase morphology were analyzed in a 155 μm × 178 μm × 210 μm volume and were seen to be decoupled. The predominant phases present in the material, half-Heusler TiNiSn, and full-Heusler TiNi{sub 2}Sn have a percolated structure. The distribution of coherent interfaces and high-angle interfaces has been measured quantitatively.

36 MATERIALS SCIENCE↗

Diagnosing x-ray power and energy of tungsten wire array z-pinch with a flat spectral response x-ray diode

Fast z-pinch is a very efficient way of converting electromagnetic energy to radiation. With an 8-10 MA current on primary test stand facility, about 1 MJ electromagnetic energy is delivered to vacuum chamber, which heats z-pinch plasma to radiate soft x-ray. To develop a pulsed high power x-ray source, we studied the applicability of diagnosing x-ray power from tungsten wire array z-pinch with a flat spectral response x-ray diode (FSR-XRD). The detector was originally developed to diagnose radiation of a hohlraum in SG-III prototype laser facility. It utilized a gold cathode XRD and a specially configured compound gold filter to yield a nearly flat spectral response in photon energy range of 0.1-4 keV. In practice, it was critical to avoid surface contamination of gold cathode. It is illustrated that an exposure of an XRD to multiple shots caused a significant change of response. Thus, in diagnosing x-ray power and energy, we used each XRD in only one shot after calibration. In a shot serial, output of FSR-XRD was compared with output of a nickel bolometer. In these shots, the outputs agreed with each other within their uncertainties which were about 12% for FSR-XRD and about 15% for bolometer. Moreover, the ratios between the FSR-XRD and the bolometer among different shots were explored. In 8 shots, the standard deviation of the ratio was 6%. It is comparable to XRD response change of 7%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel process for production of spherical PBT powders and their processing behavior during laser beam melting

Additive manufacturing processes like laser beam melting of polymers are established for production of prototypes and individualized parts. The transfer to other areas of application and to serial production is currently hindered by the limited availability of polymer powders with good processability. Within this contribution a novel process route for the production of spherical polymer micron-sized particles of good flowability has been established and applied to produce polybutylene terephthalate (PBT) powders. Moreover, the applicability of the PBT powders in selective laser beam melting and the dependencies of process parameters on device properties will be outlined. First, polymer micro particles are produced by a novel wet grinding method. To improve the flowability the produced particles the particle shape is optimized by rounding in a heated downer reactor. A further improvement of flowability of the cohesive spherical PBT particles is realized by dry coating. An improvement of flowability by a factor of about 5 is achieved by subsequent rounding of the comminution product and dry-coating as proven by tensile strength measurements of the powders. The produced PBT powders were characterized with respect to their processability. Therefore thermal, rheological, optical and bulk properties were analyzed. Based on these investigations a range of processing parameters was derived. Parameter studies on thin layers, produced in a selective laser melting system, were conducted. Hence appropriate parameters for processing the PBT powders by laser beam melting, like building chamber temperature, scan speed and laser power have been identified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study on efficiency of time computation in x-ray imaging simulation base on Monte Carlo algorithm using graphics processing unit

Monte Carlo (MC) is one of the powerful techniques for simulation in x-ray imaging. MC method can simulate the radiation transport within matter with high accuracy and provides a natural way to simulate radiation transport in complex systems. One of the codes based on MC algorithm that are widely used for radiographic images simulation is MC-GPU, a codes developed by Andrea Basal. This study was aimed to investigate the time computation of x-ray imaging simulation in GPU (Graphics Processing Unit) compared to a standard CPU (Central Processing Unit). Furthermore, the effect of physical parameters to the quality of radiographic images and the comparison of image quality resulted from simulation in the GPU and CPU are evaluated in this paper. The simulations were run in CPU which was simulated in serial condition, and in two GPU with 384 cores and 2304 cores. In simulation using GPU, each cores calculates one photon, so, a large number of photon were calculated simultaneously. Results show that the time simulations on GPU were significantly accelerated compared to CPU. The simulations on the 2304 core of GPU were performed about 64 -114 times faster than on CPU, while the simulation on the 384 core of GPU were performed about 20 – 31 times faster than in a single core of CPU. Another result shows that optimum quality of images from the simulation was gained at the history start from 10{sup 8} and the energy from 60 Kev to 90 Kev. Analyzed by statistical approach, the quality of GPU and CPU images are relatively the same.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconfigurable quadruple quantum dots in a silicon nanowire transistor

We present a reconfigurable metal-oxide-semiconductor multi-gate transistor that can host a quadruple quantum dot in silicon. The device consists of an industrial quadruple-gate silicon nanowire field-effect transistor. Exploiting the corner effect, we study the versatility of the structure in the single quantum dot and the serial double quantum dot regimes and extract the relevant capacitance parameters. We address the fabrication variability of the quadruple-gate approach which, paired with improved silicon fabrication techniques, makes the corner state quantum dot approach a promising candidate for a scalable quantum information architecture.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NSLS-II biomedical beamlines for micro-crystallography, FMX, and for highly automated crystallography, AMX: New opportunities for advanced data collection

We present the final design of the x-ray optics and experimental stations of two macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source-II. The microfocusing FMX beamline will deliver a flux of ∼5×10{sup 12} ph/s at 1 Å into a 1 – 20 µm spot, its flux density surpassing current MX beamlines by up to two orders of magnitude. It covers an energy range from 5 – 30 keV. The highly automated AMX beamline is optimized for high throughput, with beam sizes from 4 – 100 µm, an energy range of 5 – 18 keV and a flux at 1 Å of ∼10{sup 13} ph/s. A focus in designing the beamlines lay on achieving high beam stability, for example by implementing a horizontal bounce double crystal monochromator at FMX. A combination of compound refractive lenses and bimorph mirror optics at FMX supports rapid beam size changes. Central components of the in-house developed experimental stations are horizontal axis goniometers with a target sphere of confusion of 100 nm, piezo-slits for dynamic beam size changes during diffraction experiments, dedicated secondary goniometers for data collection from specimen in crystallization plates, and next generation pixel array detectors. FMX and AMX will support a broad range of biomedical structure determination methods from serial crystallography on micron-sized crystals, to structure determination of complexes in large unit cells, to rapid sample screening and room temperature data collection of crystals in trays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Theoretical and experimental study of the dynamic response of absorber-based, micro-scale, oscillatory probes for contact sensing applications

This paper presents two models for predicting the frequency response of micro-scale oscillatory probes. These probes are manufactured by attaching a thin fiber to the free end of one tine of a quartz tuning fork oscillator. In these studies, the attached fibers were either 75 μm diameter tungsten or 7 μm diameter carbon with lengths ranging from around 1 to 15 mm. The oscillators used in these studies were commercial 32.7 kHz quartz tuning forks. The first theoretical model considers lateral vibration of two beams serially connected and provides a characteristic equation from which the roots (eigenvalues) are extracted to determine the natural frequencies of the probe. A second, lumped model approximation is used to derive an approximate frequency response function for prediction of tine displacements as a function of a modal force excitation corresponding to the first mode of the tine in the absence of a fiber. These models are used to evaluate the effect of changes in both length and diameter of the attached fibers. Theoretical values of the natural frequencies of different modes show an asymptotic relationship with the length and a linear relationship with the diameter of the attached fiber. Similar results are observed from experiment, one with a tungsten probe having an initial fiber length of 14.11 mm incrementally etched down to 0.83 mm, and another tungsten probe of length 8.16 mm incrementally etched in diameter, in both cases using chronocoulometry to determine incremental volumetric material removal. The lumped model is used to provide a frequency response again reveals poles and zeros that are consistent with experimental measurements. Finite element analysis shows mode shapes similar to experimental microscope observations of the resonating carbon probes. This model provides a means of interpreting measured responses in terms of the relative motion of the tine and attached fibers. Of particular relevance is that, when a “zero” is observed in the response of the tine, one mode of the fiber is matched to the tine frequency and is acting as an absorber. This represents an optimal condition for contact sensing and for transferring energy to the fiber for fluid mixing, touch sensing, and surface modification applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗