Standalone Hazard Evaluation and Refinement From Instrument Findings (S.H.E.R.I.F.)

The Standalone Hazard Evaluation From Instrument Findings (SHERIF) system is a set of novel algorithms and associated framework designed to support the generation of Digital Elevation Maps (DEMs) from multiple LiDAR scans and perform Hazard Detection (HD) and Safe Site Identification (SSI) with no dependencies on other onboard systems. SHERIF can employ several techniques to perform robust 3D keypoint extraction and Point Cloud registration (PCR) on disparate LiDAR scans of a planetary surface to generate a DEM which evolves over the course of a trajectory. The framework also supports a variety of Hazard Detection and Safe Site Identification algorithms which can be applied to the evolving DEM being produced. SHERIF features a robust and modular construction, allowing the user a high degree of flexibility in selecting and implementing whichever keypoint identificaiton, PCR and HD/SSI algorithms they may prefer, while maintaining the data products and sensor independence of the core SHERIF framework. SHERIF was recently evaluated via simulation and hardware-in-the-loop experimental testing at NASA Johnson Space Center.

hazard detection↗

Standalone Hazard Evaluation and Refinement From Instrument Findings (S.H.E.R.I.F.)

The Standalone Hazard Evaluation From Instrument Findings (SHERIF) system is a set of novel algorithms and associated framework designed to support the generation of Digital Elevation Maps (DEMs) from multiple LiDAR scans and perform Hazard Detection (HD) and Safe Site Identification (SSI) with no dependencies on other onboard systems. SHERIF can employ several techniques to perform robust 3D keypoint extraction and Point Cloud registration (PCR) on disparate LiDAR scans of a planetary surface to generate a DEM which evolves over the course of a trajectory. The framework also supports a variety of Hazard Detection and Safe Site Identification algorithms which can be applied to the evolving DEM being produced. SHERIF features a robust and modular construction, allowing the user a high degree of flexibility in selecting and implementing whichever keypoint identificaiton, PCR and HD/SSI algorithms they may prefer, while maintaining the data products and sensor independence of the core SHERIF framework. SHERIF was recently evaluated via simulation and hardware-in-the-loop experimental testing at NASA Johnson Space Center.

hazard detection↗

Systems, methods and tools for subterranean electrochemical characterization and enthalpy measurement in geothermal reservoirs

The present disclosure is directed to systems, methods and tools that measure ionic concentrations and downhole enthalpy of a flowing geothermal fluid in real-time at high-temperature and pressure. The systems, methods and tools include measuring the concentration of selected naturally occurring ions found in the liquid phase of the geothermal fluid throughout the wellbore using novel electrochemical sensor technologies. The change in liquid-phase ion concentration will be used to calculate the proportion of liquid to steam and allow for accurate enthalpy measurements. The techniques and technologies described here can be applied to any application of electrochemical sensing in extreme environments.

Cieslewski, Grzegorz↗

Enhanced detection of volatile organic compounds (VOCs) by caffeine modified carbon nanotube junctions

Detection of vapor phase analytes and gas molecules is primarily essential for numerous applications including medical diagnostic, environmental monitoring, chemical threat detection, food quality control, and chemical warfare agents. Here, we developed Caffeine functionalized carbon nanotubes (CNTs) random network based vapor quantum resistive sensors (vQRSs) for volatile organic compounds (VOCs) detection. The localized transmission electron microscopy (TEM) image and energy dispersive X-ray spectroscopy (EDS) confirm migration of caffeine to CNT–CNT junction (CNTj). We have recorded more than one order of magnitude higher sensitivity and unique selectivity towards selective VOCs (e.g., acetone, toluene, ethanol, methanol, etc.) with short response time (few seconds) for caffeine modified CNT junction (Caf-CNTj) vQRSs. Molecular dynamics (MD) calculations suggest that the sensitivity of the sensor is diffusion limited, with an advective contribution for ethanol. Furthermore, the designed Caf-CNTj sensors can potentially be important candidate to be a part of electronic nose used for various application such as breath analysis and food quality monitoring.

36 MATERIALS SCIENCE↗

Investigation of High Temperature Silica Based Fiber Optic Materials (Final Report)

This report summarizes technical progress during the program “Investigation of High Temperature Silica Based Fiber Optic Materials”, performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The objective of this program was to investigate and characterize the performance of commercially available optical fibers at elevated temperatures in replicated fuel gas streams. It also includes performing a comprehensive study of the interactions with the chemical constituents with respect to structural, optical, and mechanical stability and developing design strategies to assure reliable performance of deployed optical fibers and sensors. In the eight quarters of the project, work was done to complete the database of test results and findings for the creation of an optical fiber selection guide for high temperature applications. It is anticipated that this design tool will provide the scientific community with the information necessary to deploy sensing systems with the most robust and reliable fused silica optical fibers. Standard telecommunications grade germanium doped single and multimode fibers have been shown to perform reliably up to temperatures of 1100°C in non-hydrogen environments and/or properly designed sensor applications. Pure silica core single mode and low OH, large core step index multimode fibers, which have also shown to perform reliability up to temperatures of 1000ºC, are recommended for hydrogen and moist environments.

36 MATERIALS SCIENCE↗

Wireless Temperature Sensing Method Using no Electrical Connections

A wireless temperature sensor includes an electrical conductor and a material spaced apart from the conductor and located within one or more of the responding electric field and responding magnetic field of the conductor. The conductor is electrically unconnected and is shaped for storage of an electric field and a magnetic field. In the presence of a time-varying magnetic field, the conductor resonates to generate harmonic electric and magnetic field responses, each of which has a frequency associated therewith. The material is selected such that it experiences changes in one of dielectric properties and magnetic permeability properties in the presence of a temperature change. Shifts from the sensor's baseline frequency response indicate that the material has experienced a temperature change.

Woodard, Stanley E.↗

Real-time and Autonomous Water Quality Monitoring System Based on Remotely Operated Vehicle

Existing water quality monitoring systems near hydropower facilities are limited by the lack of mobility of the sensors’ carrier platform. Most systems use a buoy, a mounting fixture attached to a solid structure, or a human worker, which significantly limits the selection of the sampling sites and poses safety risks during data collection and equipment maintenance. To improve on this technology, we developed an autonomous water quality monitoring system that can operate in dangerous water environments near hydropower facilities for water sampling at multiple locations. The goal is to enable safe, timely, and comprehensive water-quality data collection; maximize power generation revenue with improved operational control; and reduce Federal Energy Regulatory Commission and state water quality monitoring costs for compliance. The system incorporates a remotely operated vehicle as the mobile monitoring platform, a dissolved oxygen sensor for monitoring water quality, a tether management system for automatically winding the tether, a solar mobile docking platform for suppling power to the ROV, and a web-based graphical user interface for data post-processing and visualization. In addition, preliminary field research are presented to demonstrate the system capabilities.

Salalila, Aljon L.↗

Advances in PFAS Monitoring and Remediation Using a Functionalized Material Approach - 20080

The growing global concerns about the effects to public health from human exposure to per- and polyfluoroalkyl substances (PFAS) motivates the development of strategies for reliable monitoring of PFAS in environmental streams, as well as for their rapid, effective removal if detected. For the continuous PFAS monitoring, an inexpensive, field-deployable, in situ sensor is urgently needed; yet the prevalent in situ techniques often struggle to strike a balance between the practical sensitivity and selectivity demands of the real world. Similarly, for effective PFAS removal, strategies for their fast, selective, and quantitative capture are desired, yet the present commercially available sorbents are unable to meet the requirements of rapid, quantitative capture of all PFAS components, and are notably inefficient in removing the more toxic smaller chains. To address these twin challenges, Pacific Northwest National Laboratory is developing strategies for improved detection and remediation of PFAS. For the rapid, selective, quantitative removal of PFAS from environmental streams, the strategy relies on designing capture probes with exclusively tailored electronic and spatial affinities for the PFAS that are able to selectively capture them from environmental streams. For the in situ detection and quantification of PFAS in complex, multicomponent matrices such as groundwater, the approach relies on the targeted capture of specific PFAS by these PFAS-specific capture probes immobilized on a platform. The platform acts as an electrode to directly measure PFAS concentration through a proportional change in electrical response upon their capture. A combination of optimization of platform design and incorporation of additional, sensitive detection modalities have allowed us to achieve detection limits as low as 0.5 ng/L for detection of PFAS compounds (compared to the 70 ng/L Health Advisory Limit of the U.S. Environmental Protection Agency). (authors)

47 OTHER INSTRUMENTATION↗

A technique for interpretation of multispectral remote sensor data

The author has identified the following significant results. The U.S. Army Engineer Waterways Experiment Station is engaged in a study to detect from ERTS-1 satellite data alterations to the absorption and scattering properties caused by movement of suspended particles and solutes in selected areas of the Chesapeake Bay and to correlate the data to determine the feasibility of delineating flow patterns, flushing action of the estuary, and sediment and pollutant dispersion. As a part of this study, ADP techniques have been developed that permit automatic interpretation of data from any multispectral remote sensor with computer systems which have limited memory capacity and computing speed. The multispectral remote sensor is considered as a reflectance spectrophotometer. The data which define the spectral reflectance characteristics of a scene are scanned pixel by pixel. Each pixel whose spectral reflectance matches a reference spectrum is identified, and the results are shown in a map that identifies the locations where spectrum matches were detected and spectrum that was matched. The interpretation technique is described and an example of interpreted data from ERTS-1 is presented.

Williamson, A. N.↗

Miniaturized fiber-optic Michelson-type interferometric sensors

A novel, miniaturized Michelson-type fiber-optic interferometric sensor that is relatively insensitive to temperature drifts is presented. A fused-biconical tapered coupler is cleaved immediately after the coupled length and polished down to the region of the fused cladding, but short of the interaction region. The end of one core is selectively coated with a reflective surface and is used as the reference arm; the other core serves as the sensing arm. The detection of surface acoustic waves, microdisplacements, and magnetic fields is reported. The sensor is shown to be highly stable in comparison to a classic homodyne, uncompensated Michelson interferometer, and signal-to-noise ratios of 65 dB have been obtained.

Murphy, Kent A.↗

Advanced Control Architecture and Sensor Information Development for Process Automation, Optimization, and Imaging of Chemical Looping Systems

The Syngas Chemical Looping (SCL) process developed at The Ohio State University (OSU) uses an iron-based oxygen carrier to convert syngas into high-purity hydrogen while simultaneously capturing carbon dioxide that is readily sequestrable. A 25 kWth sub-pilot unit was successfully demonstrated multiple times on the OSU Clean Coal Research Facility, and a 250 kWth – 3 MWth pilot demonstration unit has been designed and constructed at the National Carbon Capture Center (NCCC) in Wilsonville, Alabama. The focus of this project is to develop multiple technologies to automate the startup and shutdown of chemical looping system. Success of this project will propel the advanced carbon capture method toward commercialization, hence be disruptive to the fossil fuel and power industries. Advanced process automation control architecture and imaging and optimization sensor software were developed for OSU chemical looping process. A high-level controller (HLC) consisting of decision-making and controller-selection logic integrated with sliding mode controllers (SMCs) were developed to perform chemical looping process startup and shutdown. Babcock & Wilcox Power Generation Group’s FocalPoint Optimization System was implemented to optimize the process operating conditions. The process automation controller and optimization information were realized and tested on OSU’s existing sub-pilot chemical looping test unit under atmospheric condition. The implemented control architecture was able to perform the complete process procedure from startup, steady-state reaction operation to shutdown with minimal operator intervention. The controller was also implemented on the pressurized syngas chemical looping (SCL) pilot test unit constructed at the National Carbon Capture Center (NCCC), demonstrating its pressure control capability with a designed transient state trajectory. An electrical capacitance volume tomography (ECVT) sensor device and its software were developed to image the packed moving bed and slugging fluidized bed of oxygen carriers in chemical looping systems at elevated temperatures. The ECVT device constructed was capable of tracking the subtle voidage variance along the moving bed axis as a feature for directly measuring the oxygen carrier particles’ linear velocity. Also, the high temperature ECVT device was used to study the fluidization characteristics of Geldart Group D particles.

08 HYDROGEN↗

Impact of Thematic Mapper Sensor Characteristics on Classification Accuracy

A three factor (spectral, spatial, and radiometric resolution), two level (TM and MSS) analysis of variance (ANOVA) approach allowed evaluation of the effects of each factor individually and in all possible combinations. Digital classification accuracy was used as the figure of merit. Nine study sites in Washington, D.C. each of approximately 256 x 256 TM pixels, were randomly selected from the full scene for analysis. These results strongly suggest that the quantization level improvements and the addition of new spectral bands in the visible and middle IR regions (both afforded by the TM sensor design) can result in improved capabilities to accurately delineate land cover categories using a per point Gaussian maximum likelihood classifier. On the other hand, results indicate that the increase in spatial resolution to 30m does not significantly enhance classification accuracy. The spatial result points to an inherent limitation of a per point classifier and to the need to improve data analysis techniques to handle high spatial resolution data.

Williams, D. L.↗

Impact of thematic mapper sensor characteristics on classification accuracy

A three factor (spectral, spatial, and radiometric resolution), two level (TM and MSS) analysis of variance (ANOVA) approach allowed evaluation of the effects of each factor individually and in all possible combinations. Digital classification accuracy was used as the figure of merit. Nine study sites in Washington, DC, each of approximately 256 x 256 TM pixels, were randomly selected from the full scene for analysis. These results strongly suggest that the quantization level improvements and the addition of new spectral bands in the visible and middle IR regions (both afforded by the TM sensor design) can result in improved capabilities to accurately delineate land cover categories using a per point Gaussian maximum likelihood classifier. On the other hand, results indicate that the increase in spatial resolution to 30 m does not significantly enhance classification accuracy. The spatial result points to an inherent limitation of a per point classifier and to the need to improve data analysis techniques to handle high spatial resolution data.

Williams, D. L.↗

Using information Theory in Optimal Test Point Selection for Health Management in NASA's Exploration Vehicles

In this paper, we will present a new methodology that measures the "worth" of deploying an additional testing instrument (sensor) in terms of the amount of information that can be retrieved from such measurement. This quantity is obtained using a probabilistic model of RLV's that has been partially developed in the NASA Ames Research Center. A number of correlated attributes are identified and used to obtain the worth of deploying a sensor in a given test point from an information-theoretic viewpoint. Once the information-theoretic worth of sensors is formulated and incorporated into our general model for IHM performance, the problem can be formulated as a constrained optimization problem where reliability and operational safety of the system as a whole is considered. Although this research is conducted specifically for RLV's, the proposed methodology in its generic form can be easily extended to other domains of systems health monitoring.

Mehr, Ali Farhang↗

Optimal Tuner Selection for Kalman-Filter-Based Aircraft Engine Performance Estimation

An emerging approach in the field of aircraft engine controls and system health management is the inclusion of real-time, onboard models for the inflight estimation of engine performance variations. This technology, typically based on Kalman-filter concepts, enables the estimation of unmeasured engine performance parameters that can be directly utilized by controls, prognostics, and health-management applications. A challenge that complicates this practice is the fact that an aircraft engine s performance is affected by its level of degradation, generally described in terms of unmeasurable health parameters such as efficiencies and flow capacities related to each major engine module. Through Kalman-filter-based estimation techniques, the level of engine performance degradation can be estimated, given that there are at least as many sensors as health parameters to be estimated. However, in an aircraft engine, the number of sensors available is typically less than the number of health parameters, presenting an under-determined estimation problem. A common approach to address this shortcoming is to estimate a subset of the health parameters, referred to as model tuning parameters. The problem/objective is to optimally select the model tuning parameters to minimize Kalman-filterbased estimation error. A tuner selection technique has been developed that specifically addresses the under-determined estimation problem, where there are more unknown parameters than available sensor measurements. A systematic approach is applied to produce a model tuning parameter vector of appropriate dimension to enable estimation by a Kalman filter, while minimizing the estimation error in the parameters of interest. Tuning parameter selection is performed using a multi-variable iterative search routine that seeks to minimize the theoretical mean-squared estimation error of the Kalman filter. This approach can significantly reduce the error in onboard aircraft engine parameter estimation applications such as model-based diagnostic, controls, and life usage calculations. The advantage of the innovation is the significant reduction in estimation errors that it can provide relative to the conventional approach of selecting a subset of health parameters to serve as the model tuning parameter vector. Because this technique needs only to be performed during the system design process, it places no additional computation burden on the onboard Kalman filter implementation. The technique has been developed for aircraft engine onboard estimation applications, as this application typically presents an under-determined estimation problem. However, this generic technique could be applied to other industries using gas turbine engine technology.

Simon, Donald L.↗

Navigation Sensor Technology Assessment Capability for Data-Driven Systems Analysis

The capability to assess the mission performance of novel navigation technologies from a systems-level approach and to provide quantitative results is crucial. With growing interest and innovations from NASA’s commercial partners, data-driven results that quantify the technological impact will guide research developments and facilitate stakeholder decision-making while requiring less time and resources. This paper presents a method to evaluate various sensor combinations and their impact on the overall system performance using an existing six degrees-of-freedom, physics-based engineering simulation for a government reference lunar lander as a testbed. Selected navigation technologies over various technology readiness levels, including Inertial Measurement Units, Navigation Doppler Lidar, and radar altimeter-radar velocimeter, were studied in this paper. Results using this testbed to perform sensitivity studies and to provide quantitative assessments are reported. One key finding is that there are diminishing returns for reducing sensor errors. The most influential sensor parameter to landing success are vehicle configuration and mission dependent. Results from this method could be used by stakeholders to make data-driven systems-based decisions and by technology developers as guidance for the specific parameter improvements that will have the most significant impact on mission success. This capability could be further used to assess alternative scenarios should one type of technology become unavailable or to re-assess initial assumptions and identify appropriate requirements from a system perspective.

Esther Lee↗

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Voltammetry measurements in lithium chloride-lithium oxide (LiCl–Li 2 O) salt: An evaluation of working electrode materials

Instrumentation to provide process monitoring (PM) and safeguards for the oxide reduction (OR) step in the electrochemical processing of used oxide nuclear fuel is necessary to ensure equipment is operated as declared. Cyclic voltammetry (CV) has been proposed for real-time monitoring of the operation of an OR process for safeguards purposes. In this study, different materials including 316 stainless steel (SS), tantalum (Ta), molybdenum (Mo), tungsten (W), platinum (Pt), and iridium (Ir) were evaluated as potential working electrode (WE) materials based on their chemical inertness, corrosion resistance, and sensitivity in detecting Li 2 O and other chloride salts in the OR electrolyte. Of the electrodes evaluated, 316 SS, Ir, and Pt all performed reasonably well in the LiCl-Li 2 O electrolyte. Here, stainless steel was operated in the cathodic potential and had reasonable corrosion resistance and is relatively inexpensive. Iridium could be operated in both the cathodic and anodic potentials and was the most corrosion resistant of those evaluated. Platinum is limited to the anodic potential range, had reasonable corrosion resistance, and was the most sensitive to Li 2 O concentrations in the salt. In the development of a stand-alone safeguards instrumentation, our recommendation is a CV sensor fitted with both Ir and Pt WEs. The results in this study may also be helpful for anode material selection in other electrometallurgy industries, such as molten salt electrolysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗