Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “schools”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Pursuing sources of heterogeneity in modeling clustered population

Abstract Researchers often have to deal with heterogeneous population with mixed regression relationships, increasingly so in the era of data explosion. In such problems, when there are many candidate predictors, it is not only of interest to identify the predictors that are associated with the outcome, but also to distinguish the true sources of heterogeneity , that is, to identify the predictors that have different effects among the clusters and thus are the true contributors to the formation of the clusters. We clarify the concepts of the source of heterogeneity that account for potential scale differences of the clusters and propose a regularized finite mixture effects regression to achieve heterogeneity pursuit and feature selection simultaneously. We develop an efficient algorithm and show that our approach can achieve both estimation and selection consistency. Simulation studies further demonstrate the effectiveness of our method under various practical scenarios. Three applications are presented, namely, an imaging genetics study for linking genetic factors and brain neuroimaging traits in Alzheimer's disease, a public health study for exploring the association between suicide risk among adolescents and their school district characteristics, and a sport analytics study for understanding how the salary levels of baseball players are associated with their performance and contractual status.

Li, Yan↗

Colleen M. Iversen

Colleen Iversen is an ecosystem ecologist who utilizes a variety of field and laboratory techniques to understand and predict how ecosystems are shaped by environmental change. Her research takes her from upland forests to flooded peatlands to thawing Arctic tundra, chasing a better understanding of the secret lives of roots hidden beneath the soil surface. She works at the millimetre scale to answer a global question: how will ecosystems respond to the climate of the future? Colleen completed her Masters in Wetland Ecology at the University of Notre Dame (IN, USA) in 2004, and her PhD in Ecology and Evolutionary Biology at the University of Tennessee (Knoxville, TN, USA) in 2008. She is now a Senior Staff Scientist in the Environmental Sciences Division at Oak Ridge National Laboratory (TN, USA) and serves as a Theme Lead in the Climate Change Science Institute. Colleen is an elected Early Career Fellow of the Ecological Society of America, and a member of the inaugural cohort of ‘New Voices’ at the National Academies of Science, Engineering, and Medicine. She views science communication as the foundation for a shared understanding of society's future, and she has shared her scientific vision on Public Radio International's ‘Science Friday’, and in the Alda School's ‘Flame Challenge’, as well as in organized symposia, sessions, and workshops.

60 APPLIED LIFE SCIENCES↗

Neighborhood sociome factors and pediatric asthma exacerbations: Protective role of tree crown density and importance of pharmacy access in Chicago's south side

Abstract Background Pediatric asthma exacerbations remain a critical public health concern, particularly in historically underserved urban settings. Objective This study investigates sociome factors—the social context of disease—associated with asthma exacerbations among children living in Chicago's South Side, leveraging clinical and publicly available generalizable census tract‐level datasets from agencies including ChiVes, the City of Chicago Data Portal, EPA, Census Bureau, HUD, NOAA, and more. The aim is to uncover novel hypotheses for potential new interventions. Methods A generalized linear model assessed associations with the outcome of asthma exacerbations while accounting for clustering at the patient level. Predictors included all variables from the Sociome Data Commons, including social, environmental, behavioral, economic, housing, and school variables. Results Predictors of decreased risk included patient age (+4.8 years, −22%), tree crown density (+6% coverage, −17%), parks per acre (+0.41, −8%), and labor market engagement (+0.8 points, −9%). Conversely, predictors of increased risk included increased distance to the nearest pharmacy (+0.28 miles, +12%), limited English skills (+2.3%, +10%), higher inequality (+0.08 points, +8%), and visits in the Spring (+11%) and Fall (+20%). Conclusion The results suggest that tree crown density, a novel finding in the context of asthma exacerbations, may play a protective role. Limited access to health care facilities such as pharmacies continues to complicate care. Clinical Implications These findings provide hypotheses for future interventions for long‐standing asthma disparities.

Allergy↗

Two-Fluid and Discrete Element Modeling of a Parallel Plate Fluidized Bed Heat Exchanger for Concentrating Solar Power

A novel high-temperature particle solar receiver is developed using a light trapping planar cavity configuration. As particles fall through the cavity, the concentrated solar radiation warms the boundaries of the receiver and in turn heats the particles. Particles flow through the system, forming a fluidized bed at the lower section, leaving the system from the bottom at a constant flowrate. Air is introduced to the system as the fluidizing medium to improve particle heat transfer and mixing. A laboratory scale cavity receiver is built by collaborators at the Colorado School of Mines and their data are used for model validation. In this experimental setup, near IR quartz lamp is used to provide flux to the vertical wall of the heat exchanger. The system is modeled using the discrete element method and a continuum two-fluid method. The computational model matches the experimental system size and the particle size distribution is assumed monodisperse. A new continuum conduction model that accounts for the effects of solid concentration is implemented, and the heat flux boundary condition matches the experimental setup. Radiative heat transfer is estimated using a widely used correlation during the post-processing step to determine an overall heat transfer coefficient. The model is validated against testing data and achieves less than 30% discrepancy and a heat transfer coefficient greater than 1000 W/m2 K.

concentrating solar power↗

Jose Cabrera dismantling and decommissioning project

The Jose Cabrera Nuclear Power Plant (NPP) was the first commercial power reactor (Westinghouse 1 loop PWR 510 MWth, 160 MWe) commissioned in Spain and provided the base for future development and training. The reactor construction started in 1963 and it was officially on-line by 1969. The NPP operated from 1969 until 2006 when it became the first reactor to be shut down after completing its operational period. The containment is reinforced concrete with a stainless steel head. In 2010 responsibility for D and D was transferred to Enresa to achieve IAEA level 3 (a green field site available for unrestricted re-uses) by 2017. Of the total of more than 104,000 tons of materials that will be generated during dismantling, it is estimated that only ∼4,000 tons will be radioactive waste, some of which, 40 t are considered as intermediate level long-lived wastes and the rest (3,960 t) will be categorized as VLLW and ILLW. The Project is divided into five phases: Phase 0 - Removal of fuel and preliminary work.. Phase 1 - Preparatory Activities for D and D. complete. Phase 2 - Dismantling of Major Components. Phase 3 - Removal of Auxiliary Installations, Decontamination and Demolition. Phase 4 - Environmental Restoration. Phase 2, is currently ongoing (50% completed). To manage the diverse aspects of decommissioning operations, Enresa uses an internally developed computerized project management tool. The tool, based on knowledge gathered from other Enresa projects, can process operations management, maintenance operations, materials, waste, storage areas, procedures, work permits, operator dose management and records. Enresa considers that communication is important for both internal and external stakeholder relations and can be used to inform, to neutralize negative opinions and attitudes, to remove false expectations and for training. Enresa has created a new multi-purpose area (exhibition/visitor centre) and encourages visits from the public, local schools, local and national politicians and technical groups. Greenfield is the final end state objective. The total cost of this project, including a 20% contingency as estimated in 2003 is 135 Meuros. This figure does not include the management of the plant spent fuel, which has constituted an independent project that has been completed in 2009 (35 Meuros). Enresa, with 15 staff on site are managing a team of ∼250 workers, 40 of whom belong to the previous operator. The spent fuel is On-Site prior to the final destination in the future Spain Centralized Spent Fuel Installation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microscopy with ultraviolet surface excitation (MUSE) enables translation of optical biopsy principles to enhance life science education

The translation of microscopy with ultraviolet surface excitation (MUSE) into a high school science classroom is investigated with the goal of providing a suitable new modality to enhance life science education. A key part of this effort is the development of laboratory exercises that can integrate the advanced capabilities of MUSE into a classroom setting. MUSE utilizes the unique property of ultraviolet light at wavelengths between 250 and 285 nm to propagate about 10 um into tissues, thus illuminating only the top cell layer. Furthermore this illumination is provided by a low-power UV LED source, which enables one to cost-efficiently implement this method into the educational environment. MUSE in education can eliminate the need for premade microscope slides and provide a far more engaging and rewarding experience for students.

47 OTHER INSTRUMENTATION↗

Monte Carlo calculations and experimental measurements of dosimetric parameters of the IRA-{sup 103}Pd brachytherapy source

This article presents a brachytherapy source having {sup 103}Pd adsorbed onto a cylindrical silver rod that has been developed by the Agricultural, Medical, and Industrial Research School for permanent implant applications. Dosimetric characteristics (radial dose function, anisotropy function, and anisotropy factor) of this source were experimentally and theoretically determined in terms of the updated AAPM Task group 43 (TG-43U1) recommendations. Monte Carlo simulations were used to calculate the dose rate constant. Measurements were performed using TLD-GR200A circular chip dosimeters using standard methods employing thermoluminescent dosimeters in a Perspex phantom. Precision machined bores in the phantom located the dosimeters and the source in a reproducible fixed geometry, providing for transverse-axis and angular dose profiles over a range of distances from 0.5 to 5 cm. The Monte Carlo N-particle (MCNP) code, version 4C simulation techniques have been used to evaluate the dose-rate distributions around this model {sup 103}Pd source in water and Perspex phantoms. The Monte Carlo calculated dose rate constant of the IRA-{sup 103}Pd source in water was found to be 0.678 cGy h{sup -1} U{sup -1} with an approximate uncertainty of {+-}0.1%. The anisotropy function, F(r,{theta}), and the radial dose function, g(r), of the IRA-{sup 103}Pd source were also measured in a Perspex phantom and calculated in both Perspex and liquid water phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric comparison of four new design {sup 103}Pd brachytherapy sources: Optimal design using silver and copper rod cores

Four new brachytherapy sources, IRA1-{sup 103}Pd, IRA2-{sup 103}Pd, IRA3-{sup 103}Pd, and IRA4-{sup 103}Pd, have been developed at Agricultural, Medical, and Industrial Research School and are designed for permanent implant application. With the goal of determining an optimal design for a {sup 103}Pd source, this article compares the dosimetric properties of these sources with reference to the authors' earlier IRA-{sup 103}Pd source. The four new sources differ in end cap configuration and thickness and in the core material, silver or copper, that carries the adsorbed {sup 103}Pd. Dosimetric data derived from the authors' Monte Carlo simulation results are reported in accordance with the updated AAPM Task Group No. 43 report (TG-43U1). For each source, the authors obtained detailed results for the dose rate constant {Lambda}, the radial dose function g(r), the anisotropy function F(r,{theta}), and the anisotropy factor {phi}{sub an}(r). In this study, the optimal source IRA3-{sup 103}Pd provides the most isotropic dose distribution in water with the dose rate constant of 0.678({+-}0.1%) cGy h{sup -1} U{sup -1}. The IRA3-{sup 103}Pd design has a silver rod core combined with thin-wall, concave end caps. Finally, the authors compared the results for their optimal source with published results for those of other source manufacturers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-206: A Comparison of Different Hardware Design Approaches for Feature-Supported Optical Head-Tracking with Respect to Angular Dependencies

Purpose: Recent research has shown that optical features significantly improve marker-less optical head-tracking for cranial radiotherapy. Simulations, however, showed that these optical features, which are used to derive tissue thickness, depend on the incident angle of the IR scanning laser beam and the perspective of the camera analyzing the reflective patterns. We present an experimental analysis determining which is the most robust optical setup concerning angular influences. Methods: In three consecutive experiments, the incident angle of the laser (1), the perspective of the camera (2) or both simultaneously (3, ‘inBeam’-perspective) were changed with respect to the target. We analyzed how this affects feature intensity. These intensities were determined from seven concentric regions of interest (ROIs) around the laser spot. Two targets were used: a tissue-like silicone phantom and a human's forehead. Results: For each experiment, the feature intensity generally decreases with increasing angle. We found that the optical properties of the silicone phantom do not fit the properties of human skin. Furthermore, the angular influence of the laser on the features is significantly higher than the perspective of the camera. With the ‘inBeam’- perspective, the smoothest decays of feature intensity were found. We suppose that this is because of a fixed relationship between both devices. This smoothness, suggesting a predictable functional relationship, may simplify angle compensation for machine learning algorithms. This is particularly prominent for the medial ROIs. The inner ROIs highly depend on the angle and power of the laser. The outer ROIs show less angular dependency but the signal strength is critically low and prone to artifacts. Therefore and because of the smooth decays, medial ROIs are a suitable tradeoff between susceptibility, signal-noise-ratio and distance to the center of the laser spot. Conclusion: For tissue thickness correlated feature acquisition, the medial ROIs with the ‘inBeam’-setup provide most valuable features This work was supported by Varian Medical Systems Inc. (Palo Alto, CA, USA). In addition, this work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-QI-11: Measurement of Renal Pyruvate-To-Lactate Exchange with Hyperpolarized 13C MRI

Purpose: Previous work [1] modeling the metabolic flux between hyperpolarized [1-13C]pyruvate and [1-13C]lactate in magnetic resonance spectroscopic imaging (MRSI) experiments failed to account for vascular signal artifacts. Here, we investigate a method to minimize the vascular signal and its impact on the fidelity of metabolic modeling. Methods: MRSI was simulated for renal metabolism in MATLAB both with and without bipolar gradients. The resulting data were fit to a two-site exchange model [1], and the effects of vascular partial volume artifacts on kinetic modeling were assessed. Bipolar gradients were then incorporated into a gradient echo sequence to validate the simulations experimentally. The degree of diffusion weighting (b = 32 s/mm{sup 2}) was determined empirically from 1H imaging of murine renal vascular signal. The method was then tested in vivo using MRSI with bipolar gradients following injection of hyperpolarized [1-{sup 13}C]pyruvate (∼80 mM at 20% polarization). Results: In simulations, vascular signal contaminated the renal metabolic signal at resolutions as high as 2 × 2 mm{sup 2} due to partial volume effects. The apparent exchange rate from pyruvate to lactate (k{sub p}) was underestimated in the presence of these artifacts due to contaminating pyruvate signal. Incorporation of bipolar gradients suppressed vascular signal and improved the accuracy of kp estimation. Experimentally, the in vivo results supported the ability of bipolar gradients to suppress vascular signal. The in vivo exchange rate increased, as predicted in simulations, from k{sub p} = 0.012 s-{sup 1} to k{sub p} = 0.020-{sup 1} after vascular signal suppression. Conclusion: We have demonstrated the limited accuracy of the two-site exchange model in the presence of vascular partial volume artifacts. The addition of bipolar gradients suppressed vascular signal and improved model accuracy in simulations. Bipolar gradients largely affected kp estimation in vivo. Currently, slow-flowing spins in small vessels and capillaries are only partially suppressed, so further improvement is possible. Funding support: Seed Grant from the Radiological Society of North America, GE Healthcare, University of Wisconsin Graduate School.

60 APPLIED LIFE SCIENCES↗

MO-C-17A-04: Forecasting Longitudinal Changes in Oropharyngeal Tumor Morphology Throughout the Course of Head and Neck Radiation Therapy

Purpose: To generate, evaluate, and compare models that predict longitudinal changes in tumor morphology throughout the course of radiation therapy. Methods: Two morphology feature vectors were used to describe the size, shape, and position of 35 oropharyngeal GTVs at each treatment fraction during intensity-modulated radiation therapy. The feature vectors comprised the coordinates of the GTV centroids and one of two shape descriptors. One shape descriptor was based on radial distances between the GTV centroid and 614 GTV surface landmarks. The other was based on a spherical harmonic decomposition of these distances. Feature vectors over the course of therapy were described using static, linear, and mean models. The error of these models in forecasting GTV morphology was evaluated with leave-one-out cross-validation, and their accuracy was compared using Wilcoxon signed-rank tests. The effect of adjusting model parameters at 1, 2, 3, or 5 time points (adjustment points) was also evaluated. Results: The addition of a single adjustment point to the static model decreased the median error in forecasting the position of GTV surface landmarks by 1.2 mm (p<0.001). Additional adjustment points further decreased forecast error by about 0.4 mm each. The linear model decreased forecast error compared to the static model for feature vectors based on both shape descriptors (0.2 mm), while the mean model did so only for those based on the inter-landmark distances (0.2 mm). The decrease in forecast error due to adding adjustment points was greater than that due to model selection. Both effects diminished with subsequent adjustment points. Conclusion: Models of tumor morphology that include information from prior patients and/or prior treatment fractions are able to predict the tumor surface at each treatment fraction during radiation therapy. The predicted tumor morphology can be compared with patient anatomy or dose distributions, opening the possibility of anticipatory re-planning. American Legion Auxiliary Fellowship; The University of Texas Graduate School of Biomedical Sciences at Houston.

60 APPLIED LIFE SCIENCES↗

MO-D-BRD-01: Memorial to Bengt Bjarngard - Memorial Lecture

We lost a legendary medical physicist, Dr. Bengt Erik Bjarngard, to angiosarcoma an aggressive type of cancer. He devoted his life to providing improved methods of radiation treatment for this devastating disease over the last 36 years. Bengt was born in a rural village of Bjarnum in southern Sweden, located near forest and is known for its furniture making. He migrated to USA at the age of 35 and was recruited by Dr. Samuel Hellman to lead a group of physicists that became the “mecca of medical physics” known as the Joint Center of Radiation Therapy (JCRT) at Harvard Medical School in Boston. Bengt mentored some of the best physicists in the country, and many of our modern treatments go back to the early days of research at the JCRT. These accomplishments, dating from 1969–1989, include: dose optimization using computer control; soft wedges; stereotactic radiosurgery (SRS); total-body irradiation (TBI); CT-planning; and radiation dosimetry. Bengt worked at Brown University in Rhode Island and at the University of Pennsylvania in Philadelphia, where he provided major contributions in radiation dosimetry, specifically with the head scatter model. He advocated superior calculation algorithm through the Helax treatment planning system that was on par from most commercial systems. Bengt served as AAPM president in 1979 and was a recipient of the Coolidge Award in 1998. He had a lifelong love of nature, retiring in 2000 from the University of Pennsylvania to take care of his 200 acres of homestead forest in Maine. His legacy continues through his contributions to radiation dosimetry. This session, on small field dosimetry, is a small tribute to his memory. Further details can be found in his obituary in Med Phy, 41(4), 040801, 2014.

60 APPLIED LIFE SCIENCES↗

MO-E-BRE-01: Determination, Minimization and Communication of Uncertainties in Radiation Therapy

Medical Physicists have a general understanding of uncertainties in the radiation treatment process, both with respect to dosimetry and geometry. However, there is a desire to be more quantitative about uncertainty estimation. A recent International Atomic Energy Agency (IAEA) report (about to be published) recommends that we should be as “accurate as reasonably achievable, technical and biological factors being taken into account”. Thus, a single recommendation as a goal for accuracy in radiation therapy is an oversimplification. That report also suggests that individual clinics should determine their own level of uncertainties for their specific treatment protocols. The question is “how do we implement this in clinical practice”? AAPM Monograph 35 (2011 AAPM Summer School) addressed many specific aspects of uncertainties in each of the steps of a course of radiation treatment. The intent of this symposium is: (1) to review uncertainty considerations in the entire radiation treatment process including uncertainty determination for each step and uncertainty propagation for the total process, (2) to consider aspects of robust optimization which optimizes treatment plans while protecting them against uncertainties, and (3) to describe various methods of displaying uncertainties and communicating uncertainties to the relevant professionals. While the theoretical and research aspects will also be described, the emphasis will be on the practical considerations for the medical physicist in clinical practice. Learning Objectives: To review uncertainty determination in the overall radiation treatment process. To consider uncertainty modeling and uncertainty propagation. To highlight the basic ideas and clinical potential of robust optimization procedures to generate optimal treatment plans that are not severely affected by uncertainties. To describe methods of uncertainty communication and display.

60 APPLIED LIFE SCIENCES↗

WE-E-19A-01: Globalization of Medical Physics

Following successful 2012–2013 International Professional Symposiums as a part of Annual AAPM meetings, representatives of AAPM and International Organization of Medical Physics (IOMP) suggested to make this tradiational Symposium a permanent part of Annual AAPM meetings in future. Following the tradition, this session includes presentations of representatives of AAPM, IOMP, European Federation of Medical Physics (EFOMP), International Atomic Energy Agency (IAEA) and International Center for Theoretical Physics (ICTP). The speakers will cover various aspects of International collaboration such as educational, professional, and scientific issues, as well as help to developing countries. With further developments of medicine and technology and increased communication with our colleagues overseas, Medical Physics becomes more and more global profession. Use of the same technology, significant progress in medical physics research and developing practical regulations worldwide makes it increasingly useful to organize global collaboration of medical physicists. Several international organizations are tasked to promote such collaboration and provide help to developing countries. Not all AAPM members are fully aware of these international efforts. It is very useful for medical physicists to know about success of our profession in other countries. Different schools present different approaches to the same problem, which allows to find the best solution. By communicating with colleagues overseas, one can learn more than from just reading scientific publications. At this session the attendees will receive a glimpse of International Medical Physics activities. Learning Objectives: Understand the globalization of Medical Physics profession and advantages of collaboration with foreign colleagues. See what role AAPM is playing in establishing contacts with colleagues overseas. Understand the role of IOMP and main directions of its activity. Learn about IAEA and how it helps developing countries. Learn about activity of EFOMP and how can help the global development of Medical Physics. Find out about ICTP and its educational programs.

07 ISOTOPE AND RADIATION SOURCES↗

WE-E-BRE-09: Investigation of the Association Between Radiation-Induced Pain and Radiation Dose in Head and Neck Cancer Patients

Purpose: Patients with head and neck cancer who undergo radiotherapy often experience several undesirable side-effects, including xerostomia, trismus, and pain in the head and neck area, but little is know about the dose-volume predictors of such pain. We investigated the association between radiation dose and both throat and esophagus pain during radiotherapy. Methods: We analyzed 124 head and neck patients who received radiotherapy at the Washington University School of Medicine in Saint Louis. For these patients, weekly PROs were recorded, including 16 pain and anatomical location questions. In addition, 17 observational symptoms were recorded. Patients were asked to describe their pain at each site according to a four-level scale: none (0), mild (1), moderate (2), and severe (3). We explored the association between throat pain and the mean dose received in oral cavity and between esophageal pain and the mean dose received in the esophagus. The severity of pain was determined by the difference between the baseline (week 1) pain score and the maximum pain score during treatment. The baseline pain score was defined as the first available pain score before receiving 10 Gy because radiotherapy pain originates later during treatment. Dose-volume metrics were extracted from treatment plans using CERR. To evaluate the correlation between pain and radiation dose, Spearman's correlation coefficient (Rs) was used. Results: The associations between throat pain and the mean dose to the oral cavity, and between esophagus pain and the mean dose to the esophagus, were both statistically significant, with Rs=0.320 (p=0.003) and Rs=0.424 (p<0.0001), respectively. Mean dose, for each structure, was a better predictor of pain than total integral dose. Conclusion: We demonstrated that pain during radiotherapy in head and neck patients highly correlates with the dose delivered. We will further investigate the association between other pain locations and relevant normal tissue dose characteristics.

60 APPLIED LIFE SCIENCES↗

WE-G-BRF-09: Force- and Image-Adaptive Strategies for Robotised Placement of 4D Ultrasound Probes

Purpose: To allow continuous acquisition of high quality 4D ultrasound images for non-invasive live tracking of tumours for IGRT, image- and force-adaptive strategies for robotised placement of 4D ultrasound probes are developed and evaluated. Methods: The developed robotised ultrasound system is based on a 6-axes industrial robot (adept Viper s850) carrying a 4D ultrasound transducer with a mounted force-torque sensor. The force-adaptive placement strategies include probe position control using artificial potential fields and contact pressure regulation by a PD controller strategy. The basis for live target tracking is a continuous minimum contact pressure to ensure good image quality and high patient comfort. This contact pressure can be significantly disturbed by respiratory movements and has to be compensated. All measurements were performed on human subjects under realistic conditions. When performing cardiac ultrasound, rib- and lung shadows are a common source of interference and can disrupt the tracking. To ensure continuous tracking, these artefacts had to be detected to automatically realign the probe. The detection is realised by multiple algorithms based on entropy calculations as well as a determination of the image quality. Results: Through active contact pressure regulation it was possible to reduce the variance of the contact pressure by 89.79% despite respiratory motion of the chest. The results regarding the image processing clearly demonstrate the feasibility to detect image artefacts like rib shadows in real-time. Conclusion: In all cases, it was possible to stabilise the image quality by active contact pressure control and automatically detected image artefacts. This fact enables the possibility to compensate for such interferences by realigning the probe and thus continuously optimising the ultrasound images. This is a huge step towards fully automated transducer positioning and opens the possibility for stable target tracking in ultrasoundguided radiation therapy requiring contact pressure of 5–10 N. This work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-05: Non-Invasive in Vivo Biodosimetry in Radiotherapy Patients Using Electron Paramagnetic Resonance (EPR) Spectroscopy

Purpose: Medical intervention following a major, unplanned radiation event can elevate the human whole body exposure LD50 from 3 to 7 Gy. On a large scale, intervention cannot be achieved effectively without accurate and efficient triage. Current methods of retrospective biodosimetry are restricted in capability and applicability; published human data is limited. We aim to further develop, validate, and optimize an automated field-deployable in vivo electron paramagnetic resonance (EPR) instrument that can fill this need. Methods: Ionizing radiation creates highly-stable, carbonate-based free radicals within tooth enamel. Using a process similar to nuclear magnetic resonance, EPR directly measures the presence of radiation-induced free radicals. We performed baseline EPR measurements on one of the upper central incisors of total body irradiation (TBI) and head and neck (H&N) radiotherapy patients before their first treatment. Additional measurements were performed between subsequent fractions to examine the EPR response with increasing radiation dose. Independent dosimetry measurements were performed with optically-stimulated luminescent dosimeters (OSLDs) and diodes to more accurately establish the relationship between EPR signal and delivered radiation dose. Results: 36 EPR measurements were performed over the course of four months on two TBI and four H & N radiotherapy patients. We observe a linear increase in EPR signal with increasing dose across the entirety of the tested range. A linear least squares-weighted fit of delivered dose versus measured signal amplitude yields an adjusted R-square of 0.966. The standard error of inverse prediction (SEIP) is 1.77 Gy. For doses up to 7 Gy, the range most relevant to triage, we calculate an SEIP of 1.29 Gy. Conclusion: EPR spectroscopy provides a promising method of retrospective, non-invasive, in vivo biodosimetry. Our preliminary data show an excellent correlation between predicted signal amplitude and delivered dose. With further development, a robust means of predicting delivered radiation dose from EPR measurements is expected. This project was funded by the Biomedical Advanced Research and Development Authority (BARDA) within the U.S. Department of Health and Human Services subcontracted through the Geisel School of Medicine at Dartmouth and by the Dartmouth Physically-Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR) Pilot Program.

60 APPLIED LIFE SCIENCES↗

SU-E-P-19: A National Collaborative Academic Medical Physics Network: Structure, Activity and Outcomes

Purpose: A national Australian inter-university medical physics (MP) group was formed in 2011/12, supported by Department of Health Better Access to Radiation Oncology BARO) seed funding. Core membership includes the six universities providing postgraduate MP courses. Objectives include increasing capacity, development and efficiency of national academic MP structures/systems and hence supporting education, clinical training and research, for the MP workforce support. Although the BARO scheme focuses on Radiation Oncology, the group has wider MP interests. Methods: Two further BARO seed grants were achieved: 1) for networked academic activities, including shared-resource teaching, eg using virtual reality systems; MP outreach to schools and undergraduates; developing web-based student and registrar education/resources, etc.; and 2) for conjoint ‘translational research’ posts between universities and partner hospitals, to clinically progress advanced RT technologies and to support students and registrars. Each university received 0.5 FTE post from each grant over 2 years (total: $1.75M) and leveraged local additional partner funds. Results: Total funding: $4–5M. Overall there have been 35 (mainly overseas) postholders bringing specific expertise, beginning in early 2013. Periods in Australia have been from 0.25–2 years (median=1). As well as the education activities, research projects include lung/spine SBRT, 4D RT, FFF beams, technology assessment, complex treatment planning, imaging for radiation oncology, DIR, adaptive breast, datamining, radiomics,etc. Observed positive impacts include: increased interest in MP courses, training support, translational research infrastructure and/or clinical practice in the hospitals involved, plus increased collaboration and effectiveness between the universities. Posts are continuing beyond grant end using leveraged funds, providing the basis for sustainability of some posts. Conclusion: The BARO-funded projects have cost-effectively produced a range of positive impacts on training, research and practice in hospitals and between universities. The evaluation of the specific post roles and activities, and their outcomes, has produced focused recommendations on continuation and sustainability. Funding was from the Australian federal Department of Health; leveraged funding was from partner universities and hospitals.

60 APPLIED LIFE SCIENCES↗