Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Probing the pH Effect on Boehmite Particles in Water Using Vacuum Ultraviolet Single-Photon Ionization Mass Spectrometry

Boehmite has been widely used in theoretical research and industry, especially for hazardous material processing. For the liquid-phase treating process, the interfacial properties of boehmite are believed to be affected by pH conditions, which change its physicochemical behavior. However, molecular-level detection on cluster ions is challenging when using bulk approaches. Herein we employ in situ vacuum ultraviolet single-photon ionization mass spectrometry (VUV SPI-MS) coupled with a vacuum-compatible microreactor system for analysis at the liquid–vacuum interface (SALVI) to investigate the solute molecular composition of boehmite under different pH conditions for the first time. The mass spectral results show that more complex clustering of solute molecules exists at the solid–liquid (s–l) interface than conventionally perceived in a “simple” aqueous solution. Besides solute ions, such as boehmite molecules and fragments, the composition and appearance energies of these newly discovered solvated cluster ions are determined by VUV SPI-MS in different pH solutions. We offer new results for the pH-dependent effect of boehmite and provide insights into a more detailed solvation mechanism at the s–l interface. By comparing the key products under different pH conditions, fundamental understanding of boehmite dissolution is revealed to assist the engineering design of waste processing and storage solutions.

SALVI↗

Resolving Salt-Induced Agglomeration of Laponite Suspensions Using X-ray Photon Correlation Spectroscopy and Molecular Dynamics Simulations

Linking the physics of the relaxation behavior of viscoelastic fluids as they form arrested gel states to the underlying chemical changes is essential for developing predictive controls on the properties of the suspensions. In this study, 3 wt.% laponite suspensions are studied as model systems to probe the influence of salt-induced relaxation behavior arising from the assembly of laponite nanodisks. X-ray Photon Correlation Spectroscopy (XPCS) measurements show that laponite suspensions prepared in the presence of 5 mM concentrations of CaCl2, MgCl2 and CsCl salts accelerate the formation of arrested gel states, with CaCl2 having a significant impact followed by CsCl and MgCl2 salts. The competing effects of ion size and charge on relaxation behavior are noted. For example, the relaxation times of laponite suspensions in the presence of Mg2+ ions are slower compared to Cs+ ions despite the higher charge, suggesting that cation size dominates in this scenario. The faster relaxation behavior of laponite suspensions in the presence of Ca2+ ions compared to Cs+ ions shows that a higher charge dominates the size of the ion. The trends in relaxation behavior are consistent with the cluster formation behavior of laponite suspensions and the electrostatic interactions predicted from MD simulations. Charge balance is achieved by the intercalation of the cations at the negatively charged surfaces of laponite suspensions. These studies show that the arrested gel state of laponite suspensions is accelerated in the presence of salts, with ion sizes and charges having a competing effect on relaxation behavior.

36 MATERIALS SCIENCE↗

Symmetry Breaking in the Lowest-Lying Excited-State of CCl4: Valence Shell Spectroscopy in the 5.0–10.8 eV Photon Energy Range

We report absolute high-resolution vacuum ultraviolet (VUV) photoabsorption cross-sections of carbon tetrachloride (CCl4) in the photon energy range 5.0–10.8 eV (248–115 nm). The molecular spectrum and electronic structure have been comprehensively investigated together with quantum chemical calculations, providing geometries, bond lengths, vertical excitation energies and oscillator strengths. The major electronic excitations have been assigned to valence and Rydberg transitions which are also accompanied by vibrational excitation assigned to degenerate stretching, v3′t2 and degenerate deformation v4′t2 modes. The rather complex nuclear dynamics along the degenerate deformation mode, v4′t2, have been thoroughly investigated by Time-Dependent Density Functional Theory (TD-DFT) method. The relevant Jahn–Teller distortion operative within the lowest-lying electronic excited-state is shown here for the first time in order to yield a weak absorption feature at 6.156 eV. Further calculations on the potential energy curves for the singlet excited-states along the C–Cl stretching coordinate show the relevance of efficient C–Cl bond excision.

Biochemistry & Molecular Biology↗

Simulating 50 keV X-ray Photon Detection in Silicon with a Down-Conversion Layer

Simulation results are presented that explore an innovative, new design for X-ray detection in the 20–50 keV range that is an alternative to traditional direct and indirect detection methods. Typical indirect detection using a scintillator must trade-off between absorption efficiency and spatial resolution. With a high-Z layer that down-converts incident photons on top of a silicon detector, this design has increased absorption efficiency without sacrificing spatial resolution. Simulation results elucidate the relationship between the thickness of each layer and the number of photoelectrons generated. Further, the physics behind the production of electron-hole pairs in the silicon layer is studied via a second model to shed more light on the detector’s functionality. Together, the two models provide a greater understanding of this detector and reveal the potential of this novel form of X-ray detection.

47 OTHER INSTRUMENTATION↗

Measuring the Mean Free Path of H i Ionizing Photons at 3.2 ≤ z ≤ 4.6 with DESI Y1 Quasars

The mean free path of ionizing photons in the intergalactic medium (IGM; λ $^{912}_{mpf}$ ) is a crucial quantity in modeling the ionization state of the IGM and the extragalactic ultraviolet background, and it is widely used in hydrodynamical simulations of galaxies and reionization. We construct the largest quasar spectrum data set to date—12,595 signal-to-noise ratio > 3 spectra—using the Y1 observations of the Dark Energy Spectroscopic Instrument, to make the most precise model-independent measurement of the mean free path at 3.2 ≤ z ≤ 4.6. By stacking the spectra in 17 redshift bins and modeling the Lyman-continuum profile, we get a redshift evolution λ $^{912}_{mpf}$ ∝ ( 1 + z ) − 4.27 at 2 ≤ z ≤ 5, which is much shallower than the previous estimate, λ $^{912}_{mpf}$ ∝ ( 1 + z ) − 5.4 . We then explore the sources of systematic bias, including the choice of the intrinsic quasar continuum, the consideration of Lyman-series opacity and Lyman-limit opacity evolution, and the definition of λ $^{912}_{mpf}$ . Combining our results with estimates of λ $^{912}_{mpf}$ at higher redshifts, we conclude at high confidence that the evolution in λ $^{912}_{mpf}$ steepens at z ≈ 5. We interpret this inflection as the transition from the end of H i reionization to a fully ionized plasma that characterizes the IGM of the past ∼10 billion yr.

79 ASTRONOMY AND ASTROPHYSICS↗

Extending water vapor measurement capability of photon-limited differential absorption lidars through simultaneous denoising and inversion

Abstract. The micropulse differential absorption lidar (MPD) was developed at Montana State University (MSU) and the National Center for Atmospheric Research (NCAR) to perform range-resolved water vapor (WV) measurements using low-power lasers and photon-counting detectors. The MPD has proven to produce accurate WV measurements up to 6 km altitude. However, the MPD's ability to produce accurate higher-altitude WV measurements is impeded by the current standard differential absorption lidar (DIAL) retrieval methods. These methods are built upon a fundamental methodology that algebraically solves for the WV using the MPD forward models and noisy observations, which exacerbates any random noise in the lidar observations. The work in this paper introduces the adapted Poisson total variation (PTV) specifically for the MPD instrument. PTV was originally developed for a ground-based high spectral resolution lidar, and this paper reports on the adaptations that were required in order to apply PTV on MPD WV observations. The adapted PTV method, coined PTV-MPD, extends the maximum altitude of the MPD from 6 to 8 km and substantially increases the accuracy of the WV retrievals starting above 2 km. PTV-MPD achieves the improvement by simultaneously denoising the MPD noisy observations and inferring the WV by separating the random noise from the non-random WV. An analysis with 130 radiosonde (RS) comparisons shows that the relative root-mean-square difference (RRMSE) of WV measurements between RS and PTV-MPD exceeds 100 % between 6 and 8 km, whereas the RRMSE between RS and the standard method exceeds 100 % near 3 km. In addition, we show that by employing PTV-MPD, the MPD is able to extend its useful range of WV estimates beyond that of the ARM Southern Great Plains Raman lidar (RRMSE exceeding 100 % between 3 and 4 km); the Raman lidar has a power-aperture product 500 times greater than that of the MPD.

54 ENVIRONMENTAL SCIENCES↗

RTN-056: Study of the Photon Transfer Curve in the CCD detectors of the Vera C. Rubin Observatory

The RECA internship program provides Colombian students with an opportunity to enhance their research skills in Astronomy, Astrophysics, and Cosmology. During this three-month program, our main objective was to study the Photon Transfer Curves (PTC) of the Vera C. Rubin Observatory, specifically the gain, and to compare it with the gain obtained through pairs of flats. Overall, the study of PTCs is crucial in understanding the performance of detectors and instruments used in Astronomy. The Vera C. Rubin Observatory is an important facility that will enable researchers to carry out a wide range of studies in this field, making it essential to investigate its gain performance. We used run 13144 to construct the PTCs and 13186 to analyze the crosstalk. We employed the LSST Science Pipelines (also known as the DM stack), a software under development for this observatory, which performs all the necessary reductions for the construction of the PTCs. We also used simulations to replicate the observed effects. Initially, we found a 5% difference between the gain calculated by PTC and pairs of flats for a flow range between 5000 and 10000 ADU. Simulations showed that this difference was due to the handling of statistics and the assumption that the distribution following the Lupton equation is Gaussian. We found an error interval for this flow region based on the vendor, with (1.8 ± 0.7, 4.1 ± 0.9) % for E2V and (0.85 ± 0.7, 2.2 ± 0.9) % for ITL. From the PTC, we also obtained the average Full Well Capacity of LSSTCam as 130000 ± 10000$ electrons. We identified a list of segments where we found differences with the results obtained by SLAC National Acceleration Laboratory in PTC parameters, low saturation level, or other defects. We detected and corrected the effect of statistics in the gain calculation using pairs of flats and proposed a code change, which was implemented in the pipeline software. We do not recommend correcting for crosstalk as it does not significantly affect the parameters and does not change the shape of the PTC. However, the opposite is true for the nonlinearity correction.

79 ASTRONOMY AND ASTROPHYSICS↗

Retinal microvascular and neuronal pathologies probed in vivo by adaptive optical two-photon fluorescence microscopy

The retina, behind the transparent optics of the eye, is the only neural tissue whose physiology and pathology can be non-invasively probed by optical microscopy. The aberrations intrinsic to the mouse eye, however, prevent high-resolution investigation of retinal structure and function in vivo. Optimizing the design of a two-photon fluorescence microscope (2PFM) and sample preparation procedure, we found that adaptive optics (AO), by measuring and correcting ocular aberrations, is essential for resolving putative synaptic structures and achieving three-dimensional cellular resolution in the mouse retina in vivo. Applying AO-2PFM to longitudinal retinal imaging in transgenic models of retinal pathology, we characterized microvascular lesions with sub-capillary details in a proliferative vascular retinopathy model, and found Lidocaine to effectively suppress retinal ganglion cell hyperactivity in a retinal degeneration model. Tracking structural and functional changes at high-resolution longitudinally, AO-2PFM enables microscopic investigations of retinal pathology and pharmacology for disease diagnosis and treatment in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

Photonic-crystal-fiber-delivered laser-triggered high-voltage gas switch

A photonic-crystal-fiber-delivered laser-triggered high-voltage gas switch can deliver a peak irradiance of greater than 5.1×1011 W/cm2 to the AK gap for a laser having a wavelength of 1064 nm. The switch is capable of operating at pressures up to 2200 psi; voltages across the gap of greater than 200 kV; operation at less than 70% self-break voltage; shot-to-shot jitter of less than 3 ns; AK gap distances of 3 mm or smaller; and triggering via a fiber-delivered laser pulse energy of as low as 500 μJ.

42 ENGINEERING↗

Photonic near infrared heater

A multilayer photonic stack comprising a lower plurality of alternating layers comprising at least A and B and an upper plurality of alternating layers comprising at least C and D, layer A comprises at least one of Al, Au, W, Ag, Ni, Ti, Pt, and Cr, layer B comprises at least one of Al2O3, AlN, MgO, SiO2, TiO2, Si3N4, MgF2, Ta2O5, SiC, Si, Ge, and Indium Tin Oxide (ITO), and layers C and D comprise at least one of Al2O3, AlN, MgO, SiO2, TiO2, Si3N4, MgF2, Ta2O5, SiC, Si, Ge, and Indium Tin Oxide (ITO).

Prasher, Ravi Shankar↗

The DUNE Vertical Drift Photon Detection System

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino experiment designed to mainly investigate oscillation parameters, supernova physics and proton decay. Its far detector will be composed of four liquid argon time projection chamber (LArTPC) underground modules, in South Dakota-USA, which will detect a neutrino beam produced at Fermilab, 1300 km away, where a near detector will be in place. The second DUNE far detector module, Vertical Drift, will be a single phase LArTPC with electron drift along the vertical axis with two volumes of 13.5 m x 6.5 m x 60 m dimensions separated by a cathode plane. The charge collection will be performed by two anode planes placed at the top and bottom of the module, each composed by stacked layers of a perforated PCB technology with electrode strips. The photon detection system (PDS) will make use of large size X-Arapuca tiles distributed over three detection planes. One plane will consist of a horizontal arrangement of double sided tiles installed on the high voltage cathode plane and two vertical planes, each placed on the longest cryostat membrane walls. A light active coverage of 14.8% over the cathode and 7.4% over the laterals should allow improvements in the low energy physics range that can be probed in DUNE, especially regarding supernova neutrinos (~10 MeV). We present the initial characterization of the Vertical Drift PDS using a Monte Carlo simulation and preliminary studies on its reconstruction capabilities at the MeV scale. The information obtained with the PDS alone should allow determination of a neutrino interaction region with a precision of at least 65 cm for events with deposited energy above 5 MeV and the deposited energy can be reconstructed with precision better than 10%, both at the center of the volume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulating long-range coherence of atoms and photons in quantum computers

Lasers and Bose-Einstein condensates (BECs) exhibit macroscopic quantum coherence in seemingly unrelated ways. Lasers possess a well-defined global phase and are characterized by large fluctuations in the number of photons. In BECs of atoms, instead, the number of particles is conserved and the global phase is undefined. Here, we present a unified framework to simulate lasers and BECs states in gate-based quantum computers, by mapping bosonic particles to qubit excitations. Our approach relies on a scalable circuit that measures the total number of particles without destroying long-range coherence. We introduce complementary probes to measure the global and relative phase coherence of a quantum state, and demonstrate their functionality on a Rigetti quantum computer. Our work shows that particle-number conservation enhances long-range phase coherence, highlighting a mechanism used by superfluids and superconductors to gain phase stiffness.

Torre, Emanuele Dalla↗

Monolithic integrated quantum dot photonic integrated circuits

A photonic integrated circuit (PIC) includes a semiconductor substrate, one or more passive components, and one or more active components. The one or more passive components are fabricated on the semiconductor substrate, wherein the passive components are fabricated in a III-V type semiconductor layer. The one or more active components are fabricated on top of the one or more passive components, wherein optical signals are communicated between the one or more active components via the one or more passive components.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

PI Loop Resonance Control for Dark Photon Experiment at 2 K Using a 2.6 GHz SRF Cavity

Two 2.6 GHz SRF cavities are being used for a dark photon search at the vertical test stand (VTS) in FNAL, for the second phase of the Dark SRF experiment. During testing at 2 K the cavities experience frequency detuning caused by microphonics and slow frequency drifts. The experiment requires that the two cavities have the same frequency within the cavity's bandwidth. These two cavities are equipped with frequency tuners consisting of three piezo actuators. The piezo actuators are used for fine-fast frequency tuning. A proportional-integral (PI) loop utilizing the three piezos on the emitter was used to stabilize the cavity frequency and match the receiver cavity frequency. The results from this implementation will be discussed. The integration time was also calculated via simulation.

43 PARTICLE ACCELERATORS↗

Testing of the 2.6 GHz SRF Cavity Tuner for the Dark Photon Experiment at 2 K

At FNAL two single cell 2.6 GHz SRF cavities are being used to search for dark photons, the experiment can be conducted at 2 K or in a dilution refrigerator. Precise frequency tuning is required for these two cavities so they can be matched in frequency. A cooling capacity constraint on the dilution refrigerator only allows piezo actuators to be part of the design of the 2.6 GHz cavity tuner. The tuner is equipped with three encapsulated piezos that deliver long and short-range frequency tuning. Modifications were implemented on the first tuner design due to the low forces on the piezos caused by the cavity. Three brass rods with Belleville washers were added to the design to increase the overall force on the piezos. The testing results at 2 K are presented with the original design tuner and with the modification.

43 PARTICLE ACCELERATORS↗

Monolithic integrated quantum dot photonic integrated circuits

A photonic integrated circuit (PIC) includes a semiconductor substrate, one or more passive components, and one or more active components. The one or more passive components are fabricated on the semiconductor substrate, wherein the passive components are fabricated in a III-V type semiconductor layer. The one or more active components are fabricated on top of the one or more passive components, wherein optical signals are communicated between the one or more active components via the one or more passive components.

Bowers, John E.↗