Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microgravity data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

A comparison of low-gravity measurements on-board Columbia during STS-40

The first NASA Spacelab Life Sciences mission (SLS-1) flew 5 June to 14 June 1991 on the orbiter Columbia (STS-40). The purpose of the mission was to investigate the human body's adaptation to the low-gravity conditions of space flight and the body's readjustment after the mission to the 1g environment of earth. In addition to the life sciences experiments manifested for the Spacelab module, a variety of experiments in other scientific disciplines flew in the Spacelab and in Get Away Special (GAS) Canisters on the GAS Bridge Assembly. Several principal investigators designed and flew specialized accelerometer systems to better assess the results of their experiments by means of a low-gravity environment characterization. This was also the first flight of the NASA Microgravity Science and Applications Division (MSAD) sponsored Space Acceleration Measurement System (SAMS) and the first flight of the NASA Orbiter Experiments Office (OEX) sponsored Orbital Acceleration Research Experiment accelerometer (OARE). We present a brief introduction to seven STS-40 accelerometer systems and discuss and compare the resulting data. During crew sleep periods, acceleration magnitudes in the 10(exp -6) to 10(exp -5)g range were recorded in the Spacelab module and on the GAS Bridge Assembly. Magnitudes increased to the 10(exp -4) level during periods of nominal crew activity. Vernier thruster firings caused acceleration shifts on the order of 10(exp -4)g and primary thruster firings caused accelerations as great as 10(exp -2) g. Frequency domain analysis revealed typical excitation of Orbiter and Spacelab structural modes at 3.5, 4.7, 5.2, 6.2, 7, and 17 Hz.

Rogers, M. J. B.↗

Life Science Research in Outer Space: New Platform Technologies for Low-Cost, Autonomous Small Satellite Missions

We develop integrated instruments and platforms suitable for economical, frequent space access for autonomous life science experiments and processes in outer space. The technologies represented by three of our recent free-flyer small-satellite missions are the basis of a rapidly growing toolbox of miniaturized biologically/biochemically-oriented instrumentation now enabling a new generation of in-situ space experiments. Autonomous small satellites (~ 1 50 kg) are less expensive to develop and build than fullsize spacecraft and not subject to the comparatively high costs and scheduling challenges of human-tended experimentation on the International Space Station, Space Shuttle, and comparable platforms. A growing number of commercial, government, military, and civilian space launches now carry small secondary science payloads at far lower cost than dedicated missions; the number of opportunities is particularly large for so-called cube-sat and multicube satellites in the 1 10 kg range. The recent explosion in nano-, micro-, and miniature technologies, spanning fields from telecommunications to materials to bio/chemical analysis, enables development of remarkably capable autonomous miniaturized instruments to accomplish remote biological experimentation. High-throughput drug discovery, point-of-care medical diagnostics, and genetic analysis are applications driving rapid progress in autonomous bioanalytical technology. Three of our recent missions exemplify the development of miniaturized analytical payload instrumentation: GeneSat-1 (launched: December 2006), PharmaSat (launched: May 2009), and O/OREOS (organism/organics exposure to orbital stresses; scheduled launch: May 2010). We will highlight the overall architecture and integration of fluidic, optical, sensor, thermal, and electronic technologies and subsystems to support and monitor the growth of microorganisms in culture in these small autonomous space satellites, including real-time tracking of their culture density, gene expression, and metabolic activity while in the space environment. Flight data and results will be presented from GeneSat-1, which tracked gene expression levels of GFP-labeled E. coli and from PharmaSat, which monitored the dose dependency of an antifungal agent against S. cerevisiae. The O/OREOS SESLO instrument, which will study the effects of radiation and microgravity upon the viability and growth characteristics of B. subtilis and the halophile Halorubrum chaoviatoris for periods of 0 - 6 months in space, will be described as well. The ongoing expansion of the small satellite toolbox of biological technologies will be summarized.

Ricco, Antonio J.↗

Evaluation of the Accuracy of Astroskin as a Behavioral Health Self-Monitoring System for Spaceflight

In space, there is a need to monitor astronauts' vital signs and assess their readiness to perform specific tasks during a mission. Currently, NASA does not have the capability to noninvasively monitor crew for extended periods of time. The Canadian Space Agency is working with the Psychophysiology Lab at NASA ARC to determine if the Astroskin could be used as a solution to this problem. Astroskin, a commercially available garment with built-in biosensors, can be comfortably worn under clothing or a spacesuit and relay information to the crewman's own mobile device. Data can also be sent wirelessly to the on-board Exploration Medical System. To determine if Astroskin meets requirements for health monitoring, it must first be validated in spaceflight analog environments. In the current study Astroskin data will be compared to traditional biomedical instrument measures of electrocardiography (ECG), respiration rate, and systolic blood pressure. The data will be recorded during Autogenic Feedback Training Exercise (AFTE), which is a type of physiological self-regulation training designed for astronauts. The data will also be recorded during simulations of the Orion spacecraft re-entry. The results to date suggest that Astroskin is a suitable ambulatory monitoring system that allows astronauts to self-diagnose and self-regulate adverse autonomic nervous system responses to sustained exposure to microgravity of spaceflight.

biomedical↗

Spacecraft Fire Safety Research at NASA Glenn Research Center

Appropriate design of fire detection systems requires knowledge of both the expected fire signature and the background aerosol levels. Terrestrial fire detection systems have been developed based on extensive study of terrestrial fires. Unfortunately there is no corresponding data set for spacecraft fires and consequently the fire detectors in current spacecraft were developed based upon terrestrial designs. In low gravity, buoyant flow is negligible which causes particles to concentrate at the smoke source, increasing their residence time, and increasing the transport time to smoke detectors. Microgravity fires have significantly different structure than those in 1-g which can change the formation history of the smoke particles. Finally the materials used in spacecraft are different from typical terrestrial environments where smoke properties have been evaluated. It is critically important to detect a fire in its early phase before a flame is established, given the fixed volume of air on any spacecraft. Consequently, the primary target for spacecraft fire detection is pyrolysis products rather than soot. Experimental investigations have been performed at three different NASA facilities which characterize smoke aerosols from overheating common spacecraft materials. The earliest effort consists of aerosol measurements in low gravity, called the Smoke Aerosol Measurement Experiment (SAME), and subsequent ground-based testing of SAME smoke in 55-gallon drums with an aerosol reference instrument. Another set of experiments were performed at NASAs Johnson Space Center White Sands Test Facility (WSTF), with additional fuels and an alternate smoke production method. Measurements of these smoke products include mass and number concentration, and a thermal precipitator was designed for this investigation to capture particles for microscopic analysis. The final experiments presented are from NASAs Gases and Aerosols from Smoldering Polymers (GASP) Laboratory, with selected results focusing on realistic fuel preparations and heating profiles with regards to early detection of smoke. SAFFIRE is the upcoming large-scale fire experiment which will be executed in a Cygnus vehicle after it undocks from the ISS.

Aerosol↗

Development of Gravity Sensitive Plant Cells (Ceratodon) in Microgravity

Protonemata of the moss Ceratodon are tip-growing cells that grow up in the dark. This cell type is unique compared to cells in almost any other organism, since the growth of the plant cell itself is completely oriented by gravity. Thus, both the processes of gravity sensing and the gravity response occur in the same cell. Gravity sensing appears to rely upon amyloplasts (starch-filled plastids) that sediment. This sedimentation occurs in specific zones and plastid zonation is complex with respect to plastid morphology, distribution, and gravity. Microtubules restrict the extent of plastid sedimentation (i.e., they are load-bearing). Light also is important since apical cells have a phytochrome-based positive phototropism, light quality influences plastid zonation and sedimentation (photomorphogenesis), and red light suppresses gravitropism at higher but not lower light intensities. Many of these processes were examined in a 16 day spaceflight experiment, "SPM-A" space moss" or "SPAM)) on STS-87 that landed in December, 1997. The work described here involves the definition of a second flight experiment that builds upon the data and questions arising from STS-87. Effort was directed towards further definition of an experiment for the Shuttle (dubbed "SOS" for "Son of SPAM"). Our current target is STS 107 that is scheduled to fly in January 2001. This definition addressed two goals of the STS107 experiment. The goals of the current experiment were to determine whether the cytoskeleton plays a role in maintaining and generating an apical (non-random) plastid distribution in microgravity and to determine the development and extent of clockwise spiral tip-growth in microgravity.

Sack, Fred D.↗

Sixteen-Day Bedrest Significantly Increases Plasma Colloid Osmotic Pressure

Upon exposure to microgravity, astronauts lose up to 10% of their total plasma volume, which may contribute to orthostatic intolerance after space flight. Because plasma colloid osmotic pressure (COP) is a primary factor maintaining plasma volume, our objective was to measure time course changes in COP during microgravity simulated by 6 deg. head-down tilt (HDT). Seven healthy male subjects (30-55 years of age) were placed in HDT for 16 days. For the purpose of another study, three of the seven subjects were chosen to exercise on a cycle ergometer on day 16. Blood samples were drawn immediately before bedrest on day 14 of bedrest, 18-24 hours following exercise while all subjects were still in HDT and 1 hour following bedrest termination. Plasma COP was measured in all 20 microliter EDTA-treated samples using an osmometer fitted with a PM 30 membrane. Data were analyzed with paired and unpaired t-tests. Plasma COP on day 14 of bedrest (29.9 +/- 0.69 mmHg) was significantly higher (p less than 0.005) than the control, pre-bedrest value (23.1 +/- 0.76 mmHg). At one hour of upright recovery after HDT, plasma COP remained significantly elevated (exercise: 26.9 +/- 0.87 mmHg; no exercise: 26.3 +/- 0.85 mmHg). Additionally, exercise had no significant effect on plasma COP 18-24 hours following exercise (exercise: 27.8 +/- 1.09 mmHg; no exercise: 27.1 +/- 0.78 mmHg). Our results demonstrate that plasma COP increases significantly with microgravity simulated by HDT. However, preliminary results indicate exercise during HDT does not significantly affect plasma COP.

Hargens, Alan R.↗

A preliminary analysis of the USML-1 drop dynamics experimental results

This is a quick-look report of the results of the drop dynamics experiments that were conducted in the Drop Physics Module aboard the United States Microgravity Laboratory (USML-1) Space Shuttle mission (STS 50) from June 25 to July 9, 1992. Two types of drop dynamics experiments namely: rotations of spherical drops and oscillations of simple and compound drops were studied. Preliminary results indicate that for the rotating liquid drop experiments, the experimental data agrees well with the theoretical (numerical) predictions in the axisymmetric and the two-lobed regions. The dynamics of the bifurcation point was studied, and it was found that the shift in the bifurcation point, due to drop deformation and due to spin-up and spin-down, coroborates the previous experimental data.

Wang, T. G.↗

A Microbial Analysis of Space-Grown Produce

Before space crops become a permanent staple of the astronaut diet, we must first understand how plants and pathogenic microbes interact in microgravity. Crops such as red romaine lettuce and Chinese cabbage were grown on the International Space Station and sent back to Kennedy Space Center for microbial analysis. Aerobic plate counts and metagenomic sequencing were used to characterize bacterial and fungal communities for plants and their respective ''pillows''. These data will be used to create new guidelines for the microbial safety of space-grown produce, and will help us better protect astronauts from food-borne pathogens like E.coli, Staphylococcus, and Salmonella.

Barash, Eric L.↗

Validation of A Sensorimotor Disorientation Ground Analog

INTRODUCTION Simulating the sensorimotor disorientation effects of gravity transitions after prolonged stays in microgravity is exceedingly challenging on Earth. In a previous study [1], a Sensorimotor Disorientation Analog (SDA) was developed based on subjective feedback from previously flown astronauts. The purpose of this study was to validate this SDA by comparing performance in movement tasks that have a wealth of spaceflight data against task performance while using the SDA. METHODS Thirty healthy non-astronaut subjects (17 males, 13 females; Mean ± SD, Age: 33.5 ± 7.2 years, Height: 68.0 ± 3.4 in, Weight: 164 ± 26 lbs.) volunteered to participate in this study. Subjects performed three movement tasks: computerized dynamic posturography (CDP), obstacle walk, and tandem walk. For CDP, subjects maintained an upright stance for 20s with eyes closed on an unstable pitch sway-referenced platform with head erect (sensory organization test (SOT)-5) and with head pitch ±20° to an auditory cue(SOT-5M). The obstacle walk involved a sit-to-stand with 10s of quiet stance followed by walking to and around a cone placed 4m away while navigating a 30cm obstacle to the cone and back. The tandem walk involved walking heel-to-toe for approximately 10-12 steps with eyes open and eyes closed. Subjects performed the three movement tasks under three levels of the SDA replicating different time points of recovery: none (preflight), low (Return (R)+24- 48hours), and high (R+0- 24hours). The SDA included galvanic vestibular stimulation (GVS) to disorient the vestibular system and a weighted suit (trunk, wrists, and ankles) to alter proprioceptive feedback and replicate subjective heaviness. RESULTS As the SDA magnitude increased, overall performance outcomes decreased. However, the ability of the SDA to replicate the range of astronaut postflight performance was task dependent. CDP SOT-5 performance across SDA levels closely replicated astronaut performance at all time points. SOT-5M, however, had minimal performance changes across SDA levels and was unable to replicate astronaut performance. The obstacle walk showed performance changes across SDA levels and matched astronaut performance preflight and at R+24-48hrs (low). Obstacle walk performance at the high SDA level was reduced in comparison to the low level; however, it was not replicative of astronaut performance immediately after landing. Last, tandem walk had distinct groupings of performance across SDA levels and was able to elicit a high level of disorientation consistent with R+0-24 hours (high) postflight performance for eyes open and eyes closed. The low SDA level for both eyes open and eyes closed was more disruptive than previous crewmember performance at the R+24-48 hours timepoint. CONCLUSION The SDA was developed to replicate postflight sensorimotor disruptions. However, it is well-known that immediately post-landing, astronauts can experience motion sickness, dehydration, fatigue, orthostatic intolerance, illusory sensations, lumbar pain, etc. This multi-system response to return to 1G varies widely across astronauts and, as such, it was not unexpected that the extreme ends of responses in the R+0-24hrs time period were the most difficult to replicate. These results suggest that the SDA levels are able to elicit distinct performance groupings and, although not able to perfectly replicate R+0-24hrs, the SDA did replicate a large range of performance after return to Earth.

S C Moudy↗

Microgravity Research on the NASA Lewis Learjet Test Facility

Results from preliminary performance tests conducted in an aircraft low-G testbed for nonfree-floating experimental packages have identified several operational variables that directly influence the duration and quality of each trajectory. Flight test measurements were made to identify and quantify the presence of higher-frequency airborne and structureborne noise that may affect the correlation of research data with acceleration levels recorded on trajectory traces.

Boyer, E. O.↗

Evaluation of CO2, N2 and He as Fire Suppression Agents in Microgravity

The U.S. modules of the International Space Station use gaseous CO2 as the fire extinguishing agent. This was selected as a result of extensive experience with CO2 as a fire suppressant in terrestrial applications, trade studies on various suppressants, and experiments. The selection of fire suppressants and suppression strategies for NASA s Lunar and Martian exploration missions will be based on the same studies and normal-gravity data unless reduced gravity fire suppression data is obtained. In this study, the suppressant agent concentrations required to extinguish a flame in low velocity convective flows within the 20-sec of low gravity on the KC-135 aircraft were investigated. Suppressant gas mixtures of CO2, N2, and He with the balance being oxygen/nitrogen mixtures with either 21% or 25% O2 were used to suppress flames on a 19-mm diameter PMMA cylinder in reduced gravity. For each of the suppressant mixtures, limiting concentrations were established that would extinguish the flame at any velocity. Similarly, concentrations were established that would not extinguish the flame. The limiting concentrations were generally consistent with previous studies but did suggest that geometry had an effect on the limiting conditions. Between the extinction and non-extinction limits, the suppression characteristics depended on the extinguishing agent, flow velocity, and O2 concentration. The limiting velocity data from the CO2, He, and N2 suppressants were well correlated using an effective mixture enthalpy per mole of O2, indicating that all act via O2 displacement and cooling mechanisms. In reduced gravity, the agent concentration required to suppress the flames increased as the velocity increased, up to approximately 10 cm/s (the maximum velocity evaluated in this experiment). The effective enthalpy required to extinguish flames at velocities of 10 cm/s is approximately the same as the concentrations in normal gravity. A computational study is underway to further evaluate these findings.

Ruff, Gary A.↗

Effect of Strict Head Down Tilt Bedrest on Pituitary Gland Height

BACKGROUND Pituitary gland deformity and loss of pituitary height have been identified in astronauts postflight, hypothesized to be related to increased intracranial pressure or intracranial pressure pulsatility exposure from prolonged weightlessness. Microgravity-induced chronic headward fluid shift has been suggested as a root cause of intracranial compliance changes leading to altered intracranial pressure dynamics. Elevated intracranial pressure or pressure pulsatility is theorized to promote the development of an arachnoid diverticulum, which herniates into the pituitary fossa via a defect in the diaphragma sellae compressing the pituitary gland. We aimed to determine if chronic headward fluid induced by strict head-down tilt bed rest (HDTBR) can cause similar quantitative changes in pituitary gland height. METHODS Control group data from two 6-degree HDTBR studies were analyzed (SANS CM and AGBRESA). The AGBRESA study collected MRI data at Baseline, 14 days into HDTBR (HDTBR-14), 52 days into HDTBR (HDTBR-52), and three days into Recovery (R+ 3) and included eight healthy adults (2 women), age = 33 ± 8 years. The SANS CM collected MRI data at Baseline, 15 days into HDTBR (HDTBR-15), 29 days into HDTBR (HDTBR-29), and 12 days into Recovery (R+12) and included twelve healthy adults (4 women), age = 34 ± 9 years. Pituitary gland height was evaluated using a sagittal, 3D T1-MPRAGE sequence obtained on a dedicated 3T Siemens Biograph MRI scanner using a 32-channel head coil. Following the reconstruction of a true orthogonal sagittal plane of the pituitary gland using a 3D multiplanar reconstruction tool (Horosproject.org), the anterior pituitary mid-gland height at the pituitary stalk level was quantified according to the methodology described by Kramer et al. . A paired t-test was used to evaluate changes from the baseline measurements. FINDINGS The mean height of the pituitary gland at baseline was 6.5 ± 1.7 mm (AGBRESA) and 5.7 ± 1.6 mm (SANS CM). From baseline measurements, the SANS CM STUDY data showed a decrease in mean pituitary height of 0.3 mm (p=.011) at HDTBR-15, 0.5 mm at HDTBR-29 (p<.001) and 0.2 mm at R+12 (p=.02). From baseline measurements, the AGBRESA data showed a decrease in mean pituitary height of 0.3 mm (p=.06) at HDTBR-14, 0.6 mm at HDTBR-52 (p<.002) and 0.2 mm at R+3 (p=.13). CONCLUSION HDTBR results in progressive loss of pituitary height, which is most severe with the longest HDTBR exposure. Early pituitary height loss was the same at HDTBR-14 (AGBRESA) and HDTBR-15 (SANS CM). Residual pituitary height loss was the same at R+12 and R+3 but only significant in the latter (SANS CM). The degree of pituitary height loss at HDTBR-52 replicates the 0.6 mm height loss found in long-duration astronauts after approximately six months of microgravity exposure (p<.01, preflight mean height=5.9 mm). The hormonal effects of pituitary height loss are unknown in astronauts and HDTBR subjects and should be investigated in future studies. Future work will examine the individual variability in the loss of pituitary gland height and whether those changes are associated with other SANS findings, such as optic disc edema.

L A Kramer↗

Cal Poly Space Project G-279

The Cal Poly Space Project is an effort on the part of several highly motivated students to deploy a space canister which will examine the effects of microgravity on electroplating and immiscible metals. The experiments will be controlled and monitored by a specialized triple redundancy system developed to defer the possible electronic errors due to uncontrollable factors such as photons from the Sun. With the finalization of the payload design and the near completion of the data control system, the integration phase of the project is anticipated to be completed and the project ready for launching by early 1987. It is hoped that the experiments will lead to new insights in space research and also prove profitable to industry.

Farley, David R.↗

Flame Characterization Using a Tunable Solid-State Laser with Direct UV Pumping

Tunable solid-state lasers with direct UV pumping, based on d-f transitions of rare earth ions incorporated in wide band-gap dielectric crystals, are reliable sources of laser radiation that are suitable for excitation of combustion-related free radicals. We have employed such a laser for analytical flame characterization utilizing Laser-Induced Fluorescence (LIF) techniques. LIF spectra of alkane-air flames (used for studying combustion processes under normal and microgravity conditions) excited in the region of the A-X (0,0) OH-absorption band have been recorded and found to be both temperature-sensitive and positionally-sensitive. In addition, also clearly noticeable was the sensitivity of the spectra to the specific wavelength used for data registration. The LiCAF:Ce laser shows good prospects for being able to cover the spectral region between 280 and 340 nm and therefore be used excitation of combustion-intermediates such as the hydroxyl OH, methoxy CH30 and methylthio CH3S radicals.

Kamal, Mohammed M.↗

An EXPRESS Rack Overview and Support for Microgravity Research on the International Space Station (ISS)

The EXpedite the PRocessing of Experiments to Space Station or EXPRESS Rack System has provided accommodations and facilitated operations for microgravity-based research payloads for over 6 years on the International Space Station (ISS). The EXPRESS Rack accepts Space Shuttle middeck type lockers and International Subrack Interface Standard (ISIS) drawers, providing a modular-type interface on the ISS. The EXPRESS Rack provides 28Vdc power, Ethernet and RS-422 data interfaces, thermal conditioning, vacuum exhaust, and Nitrogen supply for payload use. The EXPRESS Rack system also includes payload checkout capability with a flight rack or flight rack emulator prior to launch, providing a high degree of confidence in successful operations once an-orbit. In addition, EXPRESS trainer racks are provided to support crew training of both rack systems and subrack operations. Standard hardware and software interfaces provided by the EXPRESS Rack simplify the integration processes for ISS payload development. The EXPRESS Rack is designed to accommodate multidiscipline research, allowing for the independent operation of each subrack payload within a single rack. On-orbit operations began for the EXPRESS Rack Project on April 24, 2001, with one rack operating continuously to support high-priority payloads. The other on-orbit EXPRESS Racks operate based on payload need and resource availability. Over 50 multi-discipline payloads have now been supported on-orbit by the EXPRESS Rack Program. Sustaining engineering, logistics, and maintenance functions are in place to maintain hardware, operations and provide software upgrades. Additional EXPRESS Racks are planned for launch prior to ISS completion in support of long-term operations and the planned transition of the U.S. Segment to a National Laboratory.

Pelfrey, Joseph J.↗

Ambulation During Periods of Supersaturation Increase Decompression Stress in Spacewalk Simulations

Musculoskeletal activity accelerates inert gas elimination during oxygen breathing prior to decompression (prebreathe), but may also promote bubble formation (nucleation) and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of musculoskeletal activity and the level of tissue supersaturation are likely critical to the net effect. Understanding the relationships is important to evaluate exercise prebreathe protocols and quantify decompression risk in gravity and microgravity environments. The NASA Prebreathe Reduction Program (PRP) combined oxygen prebreathe and exercise preceding a low pressure (4.3 psia; altitude equivalent of 30,300 ft [9,235 m]) simulation exposure of non-ambulatory subjects (a microgravity analog) to produce two protocols now used by astronauts preparing for extravehicular activity. One protocol included both upright cycling and non-cycling exercise (CEVIS: 'cycle ergometer vibration isolation system') and one protocol relied on non-cycling exercise only (ISLE: 'in-suit light exercise'). CEVIS trial data serve as control data for the current study to investigate the influence of ambulation exercise in 1G environments on bubble formation and the subsequent risk of DCS.

Pollock, N. W.↗

Computed Tomography Support for Microgravity Materials Science Experiments

The accurate measurement of density in both liquid and solid samples is of considerable interest to Principal Investigators with materials science experiments slated for the ISS. The work to be described is an innovative application of a conventional industrial nondestructive evaluation instrument. Traditional applications of industrial computed tomography (CT) rely on reconstructing cross sections of large structures to provide two-dimensional planar views which can identify defects such as porosity, or other material anomalies. This has been done on microgravity materials science experiments to check the integrity of ampoule-cartridge assemblies for safety purposes. With a substantially monoenergetic flux, as can be obtained with a radioactive cobalt source, there will be a direct correlation between absorption and density. Under such conditions it then becomes possible to make accurate measurements of density throughout a sample, and even when the sample itself is enclosed within a furnace and a safety required cartridge. Such a system has been installed at Kennedy Space Center (KSC) and is available to PIs to examine samples before and after flight. The CT system is being used to provide density information for two purposes. Firstly, the determination of density changes from liquid to solid is vital information to the PI for purposes of modeling the solidification behavior of his sample, and to engineers who have to design containment ampoules and must allow for shrinkage and other volume changes that may occur during processing. While such information can be obtained by pycnometric measurements, the possibility of using a furnace installed on the CT system enables one to examine potentially dangerous materials having high vapor pressures, while not needing visible access to the material. In addition, uniform temperature can readily be obtained, and the system can be controlled to ramp up, hold, and ramp down while collecting data over a wide range of parameters automatically. Results of initial tests on low melting point elements such as gallium, indium and tin will be presented, and the intent is to proceed to compounds such as InSb, HgCdTe and CdTe. Alloys such as Pb-Sb (PI - Poirier, U AZ) and Cu-Al (PI - Trivedi, Ames Lab.), which are the subjects of flight experiments, will also be examined. The second application is the conversion of measured density values directly to composition. This was successfully done with the mercury cadmium telluride alloys grown on the second and fourth United States Microgravity Payload (USMP-2 and USMP-4) missions by Lehoczky. CdTe values along the length of the boules were obtained at KSC prior to cutting the sample, and could have been obtained prior to its removal from the cartridge and ampoule. Examples of the data obtained will be shown. It is anticipated that several of the materials science PIs will avail themselves of the technique described, initially for determining densities prior to flight, and then to acquire early quantitative data on the compositional variation within their samples.

Gillies, Donald C.↗

Effects of microgravity on renal stone risk assessment

Physiologic changes induced during human exposure to the microgravity environment of space may contribute to an increased potential for renal stone formation. Renal stone risk factors obtained 10 days before flight and immediately after return to earth indicated that calcium oxalate and uric acid stone-forming potential was increased after space flights of 4-10 days. These data describe the need for examining renal stone risk during in-flight phases of space missions. Because of limited availability of space and refrigerated storage on spacecraft, effective methods must be developed for collecting urine samples in-flight and for preserving (or storing) them at temperatures and under conditions commensurate with mission constraints.

Pietrzyk, R. A.↗