Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lighting quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Time-sequence Spectroscopy of Epsilon CrA: The 518 nm Mg i Triplet Region Analyzed with Broadening Functions

High-resolution spectroscopic observations of the W UMa-type binary ϵ CrA obtained as a time-monitoring sequence on four full and four partial nights within two weeks have been used to derive orbital elements of the system and discuss the validity of the Lucy model for description of the radial-velocity data. The observations had more extensive temporal coverage and better quality than similar time-sequence observations of the contact binary AW UMa. The two binaries share several physical properties and show very similar deviations from the Lucy model: the primary component is a rapidly rotating star almost unaffected by the presence of the secondary component, while the latter is embedded in a complex gas flow and appears to have its own rotation-velocity field, in contradiction to the model. The spectroscopic mass ratio is found to be larger than the one derived from the light-curve analysis, as in many other W UMa-type binaries, but the discrepancy for ϵ CrA is relatively minor, much smaller than for AW UMa. The presence of the complex velocity flows contradicting the assumption of solid-body rotation suggests a necessity of modification to the Lucy model, possibly along the lines outlined by Stȩpień in his concept of energy transfer between the binary components.

79 ASTRONOMY AND ASTROPHYSICS↗

An Experimental Study of Characteristic Combustion-Driven Flow for CFD Validation

A series of uni-element rocket injector studies were completed to provide benchmark quality data needed to validate computational fluid dynamic models. A shear coaxial injector geometry was selected as the primary injector for study using gaseous hydrogen/oxygen and gaseous hydrogen/liquid oxygen propellants. Emphasis was placed on the use of non-intrusive diagnostic techniques to characterize the flowfields inside an optically-accessible rocket chamber. Measurements of the velocity and species fields were obtained using laser velocimetry and Raman spectroscopy, respectively Qualitative flame shape information was also obtained using laser-induced fluorescence excited from OH radicals and laser light scattering studies of aluminum oxide particle seeded combusting flows. The gaseous hydrogen/liquid oxygen propellant studies for the shear coaxial injector focused on breakup mechanisms associated with the liquid oxygen jet under sub-critical pressure conditions. Laser sheet illumination techniques were used to visualize the core region of the jet and a Phase Doppler Particle Analyzer was utilized for drop velocity, size and size distribution characterization. The results of these studies indicated that the shear coaxial geometry configuration was a relatively poor injector in terms of mixing. The oxygen core was observed to extend well downstream of the injector and a significant fraction of the mixing occurred in the near nozzle region where measurements were not possible to obtain Detailed velocity and species measurements were obtained to allow CFD model validation and this set of benchmark data represents the most comprehensive data set available to date As an extension of the investigation, a series of gas/gas injector studies were conducted in support of the X-33 Reusable Launch Vehicle program. A Gas/Gas Injector Technology team was formed consisting of the Marshall Space Flight Center, the NASA Lewis Research Center, Rocketdyne and Penn State. Injector geometries studied under this task included shear and swirl coaxial configurations as well as an impinging jet injector.

Santoro, Robert J.↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Overview of collaborative research between UNICAMP in Brazil and Fermilab in cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N$_2$) absorption of LAr scintillation light, known as quenching, necessitates N$_2$ contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N$_2$, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N$_2$ contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared Optical Anisotropy in Quasi‐1D Hexagonal Chalcogenide BaTiSe 3

Polarimetric infrared (IR) detection bolsters IR thermography by leveraging the polarization of light. Optical anisotropy, i.e., birefringence and dichroism, can be leveraged to achieve polarimetric detection. Recently, giant optical anisotropy is discovered in quasi-1D narrow-bandgap hexagonal perovskite sulfides, A 1+x TiS 3 , specifically BaTiS 3 and Sr 9/8 TiS 3 . In these materials, the critical role of atomic-scale structure modulations in the unconventional electrical, optical, and thermal properties raises the broader question of the nature of other materials that belong to this family. To address this issue, for the first time, high-quality single crystals of a largely unexplored member of the A 1+x TiX 3 (X = S, Se) family, BaTiSe 3 are synthesized. Single-crystal X-ray diffraction determined the room-temperature structure with the P31c space group, which is a superstructure of the earlier reported P6 3 /mmc structure. The crystal structure of BaTiSe 3 features antiparallel c-axis displacements similar to but of lower symmetry than BaTiS 3 , verified by the polarization dependent Raman spectroscopy. Fourier transform infrared (FTIR) spectroscopy is used to characterize the optical anisotropy of BaTiSe 3 , whose refractive index along the ordinary (E ⊥ c) and extraordinary (E ‖ c) optical axes is quantitatively determined by combining ellipsometry studies with FTIR. With a giant birefringence Δn ∼ 0.9, BaTiSe 3 emerges as a new candidate for miniaturized birefringent optics for mid-wave infrared to long-wave infrared imaging.

optical anisotropy↗

Fractography of composite delamination

Studies were made of the fractography of mode 2 delamination and the impact damage of carbon fiber reinforced polymer composites. Laminates fractured under mode 2 loading were potted in a clear epoxy polymer, sectioned and polished and examined using transmission and reflection light microscopy. There were only occasional fibers bridging the mode 2 cracks. These cracks were not always visible probably because the crack opening displacement was too small as to be resolved using light microscopy. A study was made of the effect of repetitive impacts on laminates of AS4/3501-6 and IM6/3501-6. Plots of cumulative impact energy vs cumulative absorbed energy exhibited a sharp change in slope which corresponded to the damage area reaching the edges of the specimen. The initial slope was highly reproducible for both composite materials. On the other hand, the intersection point between the two slopes, where the damage area reaches the specimen edges, was highly variable between specimens. This variability is tentatively ascribed to differences in laminate quality.

Source record↗

COR1 Engineering Test Unit Measurements at the Mauna Loa Solar Observatory, September 2003

The COR1 Engineering Test Unit (ETU), which had been previously tested at the NCAR/HAO and NRL test facilities, was modified into an instrument capable of observing the Sun. It was then taken to the Mauna Loa Solar Observatory to observe the corona. The changes made to observe the Sun were as follows: 1. The plate scale was changed to accommodate the smaller Apogee camera. This change had already been made for the NRL tests. 2. The previous Oriel polarizer was replaced with a commercial Polarcor polarizer from Newport to be more flight-like. However, because of cost and availability considerations, this polarizer was smaller than those which will be used for flight. 3. A structure was placed around the back section of the instrument, to protect it from stray light. 4. A pointing spar borrowed from HAO was used to track the Sun. A few days into the test, it became evident that some artifacts were appearing in the data, and these artifacts were changing as the polarizer was rotated. It was decided to test two other polarizers, the Oriel polarizer which had been used in the previous tests at HAO and NRL, and a Nikon polarizer which was borrowed from a camera belonging to one of the observatory staff members. These three polarizers had much different qualities are shown.

Thompson, William↗

Halophytes, Algae, and Bacteria Food and Fuel Feedstocks

The constant, increasing demand for energy, freshwater, and food stresses our ability to meet these demands within reasonable cost and impact on climate while sustaining quality of life. This environmental Triangle of Conflicts between energy, food, and water--while provoked by anthropogenic monetary and power struggles--can be resolved through an anthropogenic paradigm shift in how we produce and use energy, water, and food. With world population (6.6 billion) projected to increase 40 percent in 40 to 60 yr, proper development of saline agriculture and aquaculture is required, as 43 percent of the Earth's landmass is arid or semi-arid and 97 percent of the Earth's water is seawater. In light of this, we seek fuel alternatives in plants that thrive in brackish and saltwater with the ability to survive in arid lands. The development and application of these plants (halophytes) become the primary focus. Herein we introduce some not-so-familiar halophytes and present a few of their benefits, cite a few research projects (including some on the alternatives algae and bacteria), and then set theoretical limits on biomass production followed by projections in terms of world energy demands. Based on diverse arid lands with a total size equivalent to the Sahara Desert (8.6(exp 8) ha, or 2.1(exp 9) acres), these projections show that halophyte agriculture and algae systems can provide for the projected world energy demand.

Hendricks, R. C.↗

Constraining Global Coronal Models with Multiple Independent Observables

Global coronal models seek to produce an accurate physical representation of the Sun's atmosphere that can be used, for example, to drive space-weather models. Assessing their accuracy is a complex task, and there are multiple observational pathways to provide constraints and tune model parameters. Here, we combine several such independent constraints, defining a model-agnostic framework for standardized comparison. We require models to predict the distribution of coronal holes at the photosphere, and neutral line topology at the model's outer boundary. We compare these predictions to extreme-ultraviolet (EUV) observations of coronal hole locations, white-light Carrington maps of the streamer belt, and the magnetic sector structure measured in situ by Parker Solar Probe and 1 au spacecraft. We study these metrics for potential field source surface (PFSS) models as a function of source surface height and magnetogram choice, as well as comparing to the more physical Wang–Sheeley–Arge (WSA) and the Magnetohydrodynamic Algorithm outside a Sphere (MAS) models. We find that simultaneous optimization of PFSS models to all three metrics is not currently possible, implying a trade-off between the quality of representation of coronal holes and streamer belt topology. WSA and MAS results show the additional physics that they include address this by flattening the streamer belt while maintaining coronal hole sizes, with MAS also improving coronal hole representation relative to WSA. We conclude that this framework is highly useful for inter- and intra-model comparisons. Integral to the framework is the standardization of observables required of each model, evaluating different model aspects.

S. T. Badman↗

Axenisation of oleaginous microalgal cultures via anoxic photosensitisation

Growing interest in sustainable food and biofuel research has necessitated high quality axenic oleaginous microalgal strains. Unfortunately, most strains available in culture banks contain commensal microbes such as bacteria and the default decontamination method involves antibiotic treatment which has begun to exacerbate the emergence of antibiotic resistance. To overcome this problem, anoxic photosensitisation was investigated as an alternate approach. Four oleaginous microalgal species (Tetradesmus obliquus, Desmodesmus armatus, Chlorella vulgaris and Nannochloropsis limnetica) were incubated in varying concentrations of Rose Bengal (0 μM, 1 μM, 3 μM or 9 μM) either in normal (oxic) or anoxic conditions, for 72 h under light (8.85 ± 0.4 W/m 2 ) in a specially designed heterotrophic growth complex (HGC) medium, followed by 72 h in standard Bold's Basal Medium (BBM). Commonly used antibiotics-based protocol was used as the control method. Post treatment, cell numbers and percentage populations were counted with Flow Cytometry, and viability was tested using standard plating methods using BBM and LB. Additionally, the contaminating microbes in the cultures were profiled using 16Ss rRNA sequencing. Anoxic conditions were able to significantly decrease bacterial content, albeit with an equally detrimental effect on the microalgal population. Although the responses differed between the microalgae, anoxic incubation along with Rose Bengal at 3 μM was able to completely decontaminate N. limnetica and C. vulgaris, while D. armatus and T. obliquus could be decontaminated with an additional streak-plating step. None of the cultures could be decontaminated using antibiotics treatment. These results suggest that axenisation of microalgal cultures was largely due to anoxy, that was synergistically enhanced by Rose Bengal at a concentration of ≥3 μM.

59 BASIC BIOLOGICAL SCIENCES↗

Challenges in Demonstrating Safety Criteria Satisfaction for External Events under a Risk-Informed Performance-Based Framework

The NRC is currently developing 10 CFR Part 53 that would establish a technology-inclusive regulatory framework for use by applicants for new commercial advanced nuclear reactors. The new draft rule language brings new explicit regulatory requirements of the quantitative health objectives (QHOs) as a constraint on plant risk and safety criteria for the plant design, including external hazards. Historically, light water reactors (LWRs) have demonstrated satisfaction of the QHOs through the use of surrogates in the form of CDF/LERF. However, these risk surrogates are not broadly applicable for all advanced reactor types, and for advanced reactors where external events are likely to be the dominant contributor to plant risk, a direct calculation of the QHOs in terms of offsite consequence is likely necessary. While the detailed analysis of low frequency events provides insights that can help justify alternative treatments to past conservatisms, the findings are dependent on the quality and confidence associated with the analyses. The assessment of external hazards presents a unique challenge, as their potential frequency of occurrence, especially of largemagnitude events, is inherently uncertain given the long return periods in question. This paper evaluates the QHOs and their potential role as safety criteria in evaluating external event risk as it applies to advanced reactors to aid in the development of consistent and appropriate analysis methodologies.

Chen, Ben↗

A simulation evaluation of a four-engine jet transport using engine thrust modulation for flightpath control

The use of throttle control laws to provide adequate flying qualities for flight path control in the event of a total loss of conventional flight control surface use was evaluated. The results are based on a simulation evaluation by transport research pilots of a B-720 transport with visual display. Throttle augmentation control laws can provide flight path control capable of landing a transport-type aircraft with up to moderate levels of turbulence. The throttle augmentation mode dramatically improves the pilots' ability to control flight path for the approach and landing flight condition using only throttle modulation. For light turbulence, the average Cooper-Harper pilot rating improved from unacceptable to acceptable (a pilot rating improvement of 4.5) in going from manual to augmented control. The low frequency response characteristics of the engines require a considerably different piloting technique. The various techniques used by the pilot resulted in considerable scatter in data. Many pilots readily adapted to a good piloting technique while some had difficulty. A new viable approach is shown to provide independent means of redundancy of transport aircraft flight path control.

Gilyard, Glenn B.↗

The Ground State Electronic Energy of Benzene

We report here on the findings of a blind challenge devoted to determining the frozen-core, full configuration interaction (FCI) ground-state energy of the benzene molecule in a standard correlation-consistent basis set of double-ζ quality. As a broad international endeavor, our suite of wave function-based correlation methods collectively represents a diverse view of the high-accuracy repertoire offered by modern electronic structure theory. In our assessment, the evaluated high-level methods are all found to qualitatively agree on a final correlation energy, with most methods yielding an estimate of the FCI value around -863 mE H . However, we find the root-mean-square deviation of the energies from the studied methods to be considerable (1.3 mE H ), which in light of the acclaimed performance of each of the methods for smaller molecular systems clearly displays the challenges faced in extending reliable, near-exact correlation methods to larger systems. While the discrepancies exposed by our study thus emphasize the fact that the current state-of-the-art approaches leave room for improvement, we still expect the present assessment to provide a valuable community resource for benchmark and calibration purposes going forward.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solid-phase hetero epitaxial growth of α-phase formamidinium perovskite

Conventional epitaxy of semiconductor films requires a compatible single crystalline substrate and precisely controlled growth conditions, which limit the price competitiveness and versatility of the process. We demonstrate substrate-tolerant nano-heteroepitaxy (NHE) of high-quality formamidinium-lead-tri-iodide (FAPbI 3 ) perovskite films. The layered perovskite templates the solid-state phase conversion of FAPbI 3 from its hexagonal non-perovskite phase to the cubic perovskite polymorph, where the growth kinetics are controlled by a synergistic effect between strain and entropy. The slow heteroepitaxial crystal growth enlarged the perovskite crystals by 10-fold with a reduced defect density and strong preferred orientation. This NHE is readily applicable to various substrates used for devices. The proof-of-concept solar cell and light-emitting diode devices based on the NHE-FAPbI 3 showed efficiencies and stabilities superior to those of devices fabricated without NHE.

36 MATERIALS SCIENCE↗

Room-temperature valley-selective emission in Si-MoSe 2 heterostructures enabled by high-quality-factor chiroptical cavities

Transition metal dichalcogenides possess valley pseudospin, enabling coupling between photon spin and electron spin for classical and quantum information processing. However, rapid valley-dephasing processes have impeded the development of scalable, high-performance valleytronic devices operating at room temperature. Here we demonstrate that a chiral resonant metasurface can enable room-temperature valley-selective emission in MoSe 2 monolayers independent of excitation polarization. This platform provides circular eigen-polarization states with a high quality factor (Q-factor) and strong chiral near-field enhancement. The fabricated Si chiral metasurfaces exhibit chiroptical resonances with Q-factors up to 450 at visible wavelengths. We reveal degrees of circular polarization (DOP) reaching a record high of 0.5 at room temperature. Our measurements show that the high DOP can be attributed to the significantly increased chiroptical local density of states, which enhances valley-specific radiative transition rates by a factor of ~13. Our work could facilitate the development of ultracompact chiral classical and quantum light sources.

42 ENGINEERING↗

Two-dimensional talc as a natural abundant ultra-broadband hyperbolic material

Here, we demonstrate that two-dimensional talc, a naturally abundant phyllosilicate mineral, supports hyperbolic phonon-polaritons (HPhPs) across the mid- and far-infrared wavelengths. Using scattering scanning near-field optical microscopy (s-SNOM) and synchrotron infrared nano-spectroscopy (SINS), we reveal tunable HPhP modes in talc flakes with long lifetimes, high confinement, and quality factors of up to 5. We further observe Fabry–Pérot cavity modes in tapered flakes, confirmed by simulations and analytical modeling. Compared to synthetic crystals, talc offers an ultra-broadband, low-cost, and sustainable platform for infrared nanophotonics and optoelectronics.

36 MATERIALS SCIENCE↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically cannot reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of a macromolecules purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals will show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "bits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Minamitani, Elizabeth Forsythe↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically can not reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "hits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Pusey, Marc L.↗